MATERIALS (ASTM) C635 AND ASTM C636 (REFERENCED IN IBC 808). AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) 7-10 <br />SECTION 13.5.6 (REFERENCED IN IBC 1613.1). <br />GENERAL RECOMMENDATIONS <br />A. REFERENCED SOURCES PER HIERARCHY: 2015 INTERNATIONAL BUILDING CODE (IBC), AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-10), AMERICAN <br />SOCIETY OF TESTING MATERIALS (ASTM C 635, ASTM C 636, ASTM E 580/E 580% AND CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION <br />ASSOCIATION (CISCA). <br />B. PARTITIONS THAT ARE TIED TO THE CEILING AND ALL PARTITIONS GREATER THAN 6 FEET IN HEIGHT SHALL BE LATERALLY BRACED TO THE <br />STRUCTURE. BRACING SHALL BE INDEPENDENT OF THE CEILING SPLAY BRACING SYSTEM. SOURCE: ASCE 7-10 SECTION 13.5.8.1 <br />C. ALL MAIN BEAMS ARE TO BE HEAVY DUTY (HD). SOURCE: ASTI E580 SECTION 5.1.1 <br />D. CEILINGS LESS THAN OR EQUAL TO 144 1 AND SURROUNDED BY WALLS CONNECTED TO .THE STRUCTURE ABOVE ARE EXEMPT FROM THE SEISMIC <br />DESIGN REQUIREMENTS. SOURCE ASTM E580 SECTION 1.4 <br />E. THESE RECOMMENDATIONS ARE INTENDED FOR SUSPENDED CEILINGS AND RELATED COMPONENTS IN AREAS THAT REQUIRE RESISTANCE TO THE <br />EFFECTS OF EARTHQUAKE MOTIONS. SOURCE: ASTM E580 SECTION 3.2 <br />F. ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN THREE INCHES. TWELVE GAGE HANGER WIRE SPACED 4 FOOT ON CENTER. <br />SOURCE: ASTM C636 SECTION 2.3.4 <br />G. CHANGES IN CEILING PLANES WILL REQUIRE POSITIVE BRACING. SOURCE: ASTM E580 SECTION 5.2.8.6 <br />LATERAL FORCE BRACING <br />H. CEILINGS CONSTRUCTED OF SCREW -OR -NAIL -ATTACHED GYPSUM BOARD ON ONE LEVEL THAT ARE SURROUNDED BY AND CONNECTED TO WALLS OR <br />SOFFITS THAT ARE LATERALLY BRACED TO THE S T RUCTURE ABOVE ARE EXEMPT FROM SEISMIC DESIGN REQUIREMENTS. SOURCE: ASCE 7-10 SECTION <br />13.5.6.2.2 EXCEPTION 2, ASTM E580 SECTION 1.7 <br />I. CEILING AREAS OF 1000 1 OR LESS SHALL BE EXEMPT FROM LATER FORCE BRACING REQUIREMENTS. SOURCE: ASTM E580 SECTION 1.6 <br />1. LATERAL FORCE BRACING SHALL BE 12 FEET ON CENTER (MAXIMUM) AND BEGIN NO FARTHER THAN 6 FEET FROM WALLS. SOURCE: ASTM E580 SECTION <br />5.2.8,2 <br />K. SEISMIC SPLAY WIRES ARE TO BE FOUR 12 GAGE WIRES ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 900 FROM EACH OTHER AND AT AN <br />ANGLE NOT EXCEEDING 450 FROM THE PLANE OF THE CEILING. SOURCE: ASTM E580 SECTION 5.2.8.2 <br />L. SEISMIC SPLAY WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF <br />NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WITH A SAFETY FACTOR OF 2, WHICHEVER IS GREATER. SOURCE: CISCA ZONES 3-4 <br />M. SPLAY WIRES ARE TO BE WITHIN 2 INCHES OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. SOURCE: ASTM E580 SECTION <br />5.2.8.2 <br />N. RIGID BRACING MAY BE USED IN LIEU OF SPLAY WIRES. SOURCE: ASTM E580 SECTION 528.4 <br />O. VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. SOURCE: ASTM E580 SECTION 5.2.8.2 <br />P. THE VERTICAL STRUT MAY BE EMT CONDUIT, METAL STUDS OR A PROPRIETARY COMPRESSION POST, <br />WALL MOLDINGS <br />Q. WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2 INCHES WIDE. ONE END OF THE CEILING GRID <br />SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A % INCH CLEARANCE FROM THE WALL AND FREE TO SLIDE. SOURCE: ASTM <br />E580 SECTION 5.2.2, SECTION 5.2.3 <br />SPREADER BARS <br />R. TERMINAL ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER OR HAVE SOME OTHER APPROVED MEANS TO PREVENT THEIR <br />SPREADING. STABILIZER BARS, CROSS TEES OR OTHER MEANS TO PREVENT SPREADING SHALL OCCUR WITHIN 8 IN. OF EACH WALL. SOURCE: ASTM <br />E580 SECTION 5.2.4 <br />S. SPREADER BARS ARE NOT REQUIRED AT PERIMETERS WHERE RUNNERS ARE ATTACHED DIRECTLY TO CLOSURE ANGLES. SPREADER BARS ARE NOT <br />REQUIRED IF A 90 DEGREE INTERSECTING CROSS OR MAIN IS WITHIN 8 INCHES OF THE PERIMETER WALL. <br />HANGER (SUSPENSION) WIRES <br />T. HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS (FIGURE 5A) COUNTER SLOPING WIRES ARE PROVIDED. SOURCE: ASTM C636 <br />SECTION 2.1.4 <br />U. HANGER WIRES SHALL BE 12 GAGE AND SPACED 4 FEET ON CENTER OR 10 GAGE SPACED 5 FEET ON CENTER. SOURCE: ASTM C636 SECTION 2.1 <br />V. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS, SOURCE: CISCA ZONES <br />3-4 <br />W. TERMINAL ENDS OF EACH MAIN BEAM AND CROSS TEE MUST BE SUPPORTED WITHIN 8 INCHES OF EACH WALL WITH A PERIMETER WIRE. SOURCE: <br />ASTM E580 SECTION 5.2.6 <br />X, WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE <br />OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE SIZED TO RESIST THE DEAD LOAD AND LATERAL FORCES <br />APPROPRIATE FOR THE SEISMIC CATEGORY. SOURCE: ASTM E580 SECTION 5.2.7.4 <br />ELECTRICAL FIXTURES <br />Y. LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GAGE HANGER WIRE CONNECTED FROM THE FIXTURE TO THE STRUCTURE <br />ABOVE. THIS WIRE MAY BE SLACK. SOURCE: ASTM E580 SECTION 5.3.4 <br />Z. LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 LBS SHALL HAVE TWO 12 GAGE WIRES ATTACHED AT OPPOSING CORNERS OF <br />THE LIGHT FIXTURE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SOURCE: ASTM E580 SECTION 5.3.5 <br />AA. LIGHT FIXTURES WEIGHING MORE THAN 56 LBS. SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. SOURCE: <br />ASTM E580 SECTION 5.3.6 <br />AB. PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE STRUCTURE ABOVE USING A 9 GAGE WIRE OR AN APPROVED ALTERNATE <br />SUPPORT WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. SOURCE: ASTM E580 SECTION 5.3.7 <br />AC. TANDEM FIXTURES MAY UTILIZE COMMON WIRES, <br />MECHANICAL SERVICES <br />AD. TERMINALS OR SERVICES WEIGHING LESS THAN 20 LBS. SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS <br />RUNNERS THAT HAVE THE SAME CARRYING CAPACITY AS THE MAIN RUNNERS, SOURCE: ASTM E580 SECTION 5.4.1 <br />AE. TERMINALS OR SERVICES WEIGHING 20 LBS. BUT NOT MORE THAN 56 LBS. SHALL HAVE, IN ADDITION TO 5.4.1, TWO 12 GAGE WIRES CONNECTING <br />THEM TO THE CEILING SYSTEM HANGERS OR THE STRUCTURE ABOVE, THESE WIRES MAY BE SLACK, SOURCE: ASTM E580 SECTION 5.4.2 <br />Al TERMINALS OR SERVICES WEIGHING MORE THAN 56 LBS. SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS, <br />SOURCE: ASTM E580 SECTION 5.4.3 <br />SEISMIC SEPARATION JOINTS <br />AG. FOR CEILING AREAS EXCEEDING 2,500 SQUARE FEET, A SEISMIC SEPARATION JOINT OR FULL HEIGHT WALL PARTITION THAT BREAKS THE CEILING <br />SHALL BE PROVIDED UNLESS ANALYSES ARE PERFORMED OF THE CEILINGS BRACING SYSTEM, CLOSURE ANGLES AND PENETRATIONS TO PROVIDE <br />SUFFICIENT CLEARANCE. SOURCE: ASCE 7-10 SECTION 13.5.6.2.2 B <br />SPRINKLERS <br />AH, FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE <br />CEILING TILE TO ALLOW FREE MOVEMENT OF AT LEAST 1 INCH IN ALL HORIZONTAL DIRECTIONS. FLEXIBLE HEAD DESIGN THAT CAN ACCOMMODATE 1 <br />INCH FREE MOVEMENT SHALL BE PERMITTED AS AN ALTERNATE. SOURCE: ASTM E580 SECTION 5.2.8.5 <br />1/2" S- <br />(4) EXI <br />PER M <br />CONCI <br />611 <br />C ° OR PER MFG. <br />a ° _ 1 <br />BOLT-DOWNLBOLLARD <br />3„ = 1„-0„ <br />8 #12 GA VERTICAL WIRE 8� <br />MAX. MAX. \ <br />HORIZONTAL STRUT <br />TYPICAL <br />(:ON-rINUOUS�. <br />!'i�IIIIIiII Jlllllllilllillll! IIIIIII IIIIIILIiII IIIIIIIIIiIIIIIIII I;IIIWillIII <br />/I ATTACHMENT PE CLEANROOM ACP PROVIDE 3/4 SPACE <br />� MOPPOSING WALL <br />MANUFACTURER'S \ <br />INSTALLATION FAIN RUNNER OR CROSS TEE <br />INSTRUCTIONS PARTITION AS SCHEDULED <br />III, -- GASKETED <br />WALL ANGLE MTL STUD COMPRESSION <br />STRUT FOR SIZE & NO SEE <br />SCHED BELOW. ATTACH @ <br />PURLIN ABOVE W/ 2#8 SHT <br />4 - #12 GA SEISMIC MTL SCREWS, DO NOT <br />SPLAY BRACE WIRES ATTACH TO STIFFENERS. <br />2 - #12 14 GA SCREWS @ <br />STUDS TO T-BAR <br />45 <br />MAIN RUNNER <br />45 °rYPICAL <br />SCHEDULE <br />MAX. HT OF COMPRESSION STRUT <br />STUD SIZE & GA <br />SINGLE STUD <br />DOUBLE STUD <br />1-5/8" x 20 GA SS <br />7'-8" <br />11'-8" <br />2-1/2" x 20 GA SS <br />T-7" <br />16-6" <br />3-1/2" x 20 GA SS <br />7'-4" <br />22'-9" <br />80OS200-54 <br />29'-0" <br />1-5/8" x 20 GA WC <br />10'-0" <br />11'-6" <br />NOTE: ATTACH DOUBLE STUD WEB TO FLANGE W/ #6 SCREW @ 18" OC <br />DETAILSUSPENDED ACT <br />3„ = 1„-0„ <br />SEE 8/A8.1 FOR SEALING <br />� SECTION THROUGH LIGHTING FIXTURE______ <br />1 1/2" = 1"-0„ <br />� i <br />�i�� ll I I <br />II ! II I+� I II <br />6 STO SOUND BATTS PINNED TO <br />UNDERSIDE OF DECK, TYP. <br />12" COLD FORMED STEEL <br />-- FRAMING, SEE STRUCTURAL <br />5/8" GWB LIGNING AT UNDERSIDE <br />OF LID METAL FRAMING, TYP, <br />EXTEND GWB WALL TO UNDERSIDE <br />OF GYP LID AND SEAL, PROVIDE <br />ill 3-5/8" MTL STUD DEFLECTION HEAD, TYP. <br />BRACED SOFFIT <br />FROM ROOF <br />STRUCTURE <br />h <br />5/8" GWB <br />PER PLP:i <br />CORNER BEADS, TYP <br />SUSPENDED CLEANROOM ACOUSTICAL <br />CEILING AS SCHEDULED <br />BULKHEAD <br />1 1/2" = 1"-0" <br />0 <br />rN <br />2"0 TUBULAR / <br />GRAB RAILS <br />PIPE AND <br />i CHAINLINK <br />— RAILING AT <br />PERIMETER; SEE <br />PLAN FOR <br />REMOVABLE <br />SECTION <br />LOCATIONS <br />STEEL FLAT <br />(- BAR SIDE <br />RAILS <br />3/4" @ STL <br />RUNGS THRU <br />SIDE RAILS <br />° ( PROVIDE 6X6 Ill <br />I W/A23 TOP AND <br />BTM FOR LADDER <br />ATTACHMENT 4' O.C. <br />r - MAX <br />- HINGED, LOCKABLE <br />METAL SECURITY <br />COVER - <br />-- -� PL 1/2X4X4 W/ <br />1/2"0 I <br />EXPANSION <br />BOLT W/ 2-1/2 <br />EMBED I <br />i J 3„ = 1„-0„ <br />MASTIC SEAL, BOTH SIDES, TYP. <br />RETAINER <br />00 <br />FASTENERS PER MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS <br />METAL STUDS C <br />5/8" GWB, SEE STRUCTURAL FOP, OSB <br />SHEAR WALL LOCATIONS <br />3" = 1„-0" <br />CHAIN OR BARRIER <br />ACROSS <br />M <br />(T/O TAT LID <br />22,00') <br />T/O R&D LID ' <br />T-- 13' -3/4" - <br />8"MIN,x3"x1/4"X3" PL <br />BRACKETS @ TOP AND <br />BOTTOM @ 4'-0" OC MAX <br />W/ 1"0 X4" LAG BOLT TO <br />BLOCKING IN WALL <br />NOTE: SIM. ACCESS <br />LADDER TO LEAD FROM <br />@a T/O 'R&D SPACE TO TAT <br />cn LID; SEE PLAN FOR <br />Z, LOCATIONS <br />LU <br />>i <br />U <br />ZD <br />L <br />cn <br />� I <br />3/4" PLYWOOD TECH. <br />DECK PER STRUCT <br />6" THERMAFIBER SAFB <br />SOUND BATTS PINNED <br />TO UNDERSIDE OF <br />DECK, TYP, <br />BASIS OF DESIGN: LATERAL LOAD = 5 1 DEFECTION LIMIT = L/240 WITH <br />GWB FINISH BOTH SIDES OF WALL OR 1 1/2" X 20 GA STRAP BRACING @ <br />48" OC WITH 2 #10 SCREWS EACH STUD ON ONE SIDE OF WALL <br />HEIGHT OF WALL STUD SIZE & GAUGE SPACING <br />UP TO 15' HIGH 3-5/8"x1 5/8",18 GA SS 24" OC MAX <br />15'-0" to 24"-9" 6" x 1 5/8", 18 GA SS 24" OC MAX <br />24'-9" to 32"-0" 6" x 2", 16 GA SS 16" OC MAX <br />32'-0" to 42"-0" 8" x 2", 14 GA SS 16" OC MAX <br />JOISTCEILING SPAN TABLE <br />JOIST TYPE <br />MAX. SPAN <br />JOIST SPACING <br />600S162-54 <br />18'-0" <br />24" O.C. <br />800S162-54 <br />25'-0" <br />24" O.C.- <br />1200S162-54 <br />33' 0" <br />- <br />24" O.C. <br />SPAN TABLE AND SPACING PROVIDED BY DCI STRUCTURAL ENGINEERS, <br />DIRECTION OF CEILING JOIST FRAMING AND JOIST TYPE PER <br />CEILING JOIST SPAN TABLE <br />INTERIOR PARTITION <br />GALV. STEEL POSTS 4'4' OC. <br />707T -I <br />BATTS6" STO SOUND <br />TO UNDERSIDE OF DECK <br />T/O OF TECH DECK <br />IT-0 3/4" 4 <br />SEE STRUCTURAL FOR T/O WALL <br />CONSTRUCTION <br />EXTEND WALL GWB TO UNDERSIDE <br />OF LID PLYWOOD AND SEAL, TYP. <br />12" COLD FORMED STEEL <br />FRAMING, SEE STRUCTURAL <br />5/8" GWB LIGNING AT UNDERSIDE <br />OF LID METAL FRAMING, TYP. <br />1/2 OSB SHEAR WALL OVER 6" <br />METAL STUDS @ 16" O.C, - SEE <br />STRUCT. <br />tawolt ICI , <br />5/8" TYPE 'X' GWB OVER <br />PLYWOOD SHEATHING <br />SUSPENDED CLEANROOM <br />ACOUSTICAL CEILING, HUNG <br />FROM JOISTS - NOT DESIGNED <br />FOR ANY LIVE LOADING <br />INTEGRAL EGRAL COVE BASE <br />BASE TO MATCH TYP, ON WAREHOUSE <br />SIDE, SEE FINISH SCHEDULE <br />METAL STUD RUNNER SAME GAUGE AS <br />PARTITION W/ MINIMUM 1" LONG <br />FLANGES ATTACHED TO EXISTING CONC <br />SLAB WITH POWER -DRIVEN FASTENERS <br />AT 24" OC - HILTI "X-DNI" PINS, 1" <br />PENETRATION MINIMUM WITH 7/8" 1 <br />WASHERS. <br />ICC-ES REPORT NO ESR-1663 <br />1200 Fifth Ave. <br />Mite 100 <br />Seattle, VVA 93101 <br />Phone: (206) 408-8500 <br />WWW.NELSONWORLDWIDE.COM <br />Owner/Client Representative, <br />Firm Name: TERRAPOWER <br />Attn: IAN VAN HOUTEN <br />360.739.2364 <br />E-mail: IVANHOUTEN@TERRAPOWER.com <br />Structural Engineer - <br />Firm Name: SHUTLER CONSULTING ENGINEERS <br />Attn: JOHN HEADLAND <br />425.450.4075 <br />JOHNH@SHUTLER.com <br />General Contractor. <br />Firm Name: PATTISON GENERAL CONTRACTOR <br />Attn: ANDY FORTINO <br />T: 206.571.3478 <br />E-mail:ANDYF@PAITISONGC.com <br />CLIENT: <br />Te-,m% <br />rya � we <br />3315 SEAWAY q�gBLVD. <br />EVERE , QUA 98203 <br />Description: No: Date: <br />PERMIT SET 05/26/2021 <br />3/4" PLYWOOD TECH, <br />DECK PER STRUCT <br />5/$„ GWB LIGNING SEAL: <br />AT UNDERSIDE OF <br />LID METAL T� _ <br />FRAMING, TYP. F/r#�IPH E I A <br />EXTEND WALL GWB TO UNDERSIDE I <br />-- 6" THERMAFIBER SAFB <br />C_— OF LID PLYWOOD AND SEAL, SOUND BATTS PINNED <br />TO UNDERSIDE OF <br />PROVIDE DEFLECTION HEAD, TYP. <br />DECK $ %f 06-G[A�sLff4jT <br />_7— 1/2 OSB SHEAR WALL; SEE STERUCT. <br />FOR DETALS AND LOCATIONS <br />SUSPENDED CLEANROOM ACOUSTICAL � �5/8`B LIGNING AT UNDERSIDE <br />I _ CEILING, HUNG FROM LID FRAMING; SEE <br />--� FOR DETAILS A8.1 8 OF LID METAL FRAMING' TYP. <br />� / , TYP. CITY STAMP: <br />SUSPENDED CLEANROOM ACOUSTICAL <br />CEILING, HUNG FROM LID FRAMING; SEE <br />�I 5/8 TYPE X GWB OVER 6 METAL 5/8 GWB OVER 3-5/8 x �� 8/A8.1 FOR DETAILS, TYP, <br />STUDS @ 16" O,C. W/ 6" STO SOUND 1-5/8", 25 GA MTL STUD j <br />- STO SOUND BAiT INSULATION IN <br />BATTS, SEE STRUCT, FOR DETAILS AND FRAMING @ 24" OC <br />WALL <br />R&D LAB ( �- ,I R&D LAB SHEAR WALL LOCATIONS R&D LAB HOT CELL TECH AREA <br />�I <br />METAL STUD RUNNER SAME GAUGE AS <br />_METAL STUD RUNNER SAME GAUGE AS ( -� <br />PARTITION W/ MINIMUM L" LONG <br />PARTITION W/ MINIMUM 1 LONG INTEGRAL COVE BASE FLANGES ATTACHED TO EXISTING CONC <br />INTEGRAL COVE BASE---�� FLANGES ATTACHED TO EXISTING CONC a �! POWER -DRIVEN FASTENERS <br />_ SLAB WITH POWER -DRIVEN FASTENERS, SLAB WITH PO„ HILT! „ S„ WALL <br />TYPES AND <br />PENETRATIONMINIMUDMIWITH7/8" DIA <br />� AT 24 OC - HILTI XC DNI PINS, 1 <br />PENETRATION MINIMUM WITH 7/8 1 CEILING DETAILS <br />WASHERS, WASHERS. <br />ICC-ES REPORT NO ESR-1663 ICC-ES REPORT NO ESR-1663 <br />-INTERIORINTERIOR PARTITION Proj. # 20.0001110.001 Reviewed By: PA/PM <br />