Laserfiche WebLink
NORMAL POWER <br />SOURCE <br />NEC 700 <br />SOURCE <br />DETAIL - EMERGENCY LIGHTING TRANSFER DEVICE <br />NONE <br />....._..... <br />coNT <br />M <br />ti <br />Cv <br />CV <br />O <br />N <br />rn <br />N <br />L <br />1_ _4_.._............................) <br />LIGHTING FLOOR <br />1/8" = 1'-0" <br />CONTROL <br />DEVICES FOR <br />LIGHTING WITHIN <br />THE ZONE/SPACE <br />0-10V CONTROLLED <br />DIMMING WHERE <br />REQUIRED <br />NORMAL SENSING <br />CIRCUIT <br />REFER TO <br />MANUFACTURER'S <br />WIRING DIAGRAM <br />FOR SPECIFICS <br />DEDICATED <br />RACEWAY SYSTEM <br />SHEET NOTES <br />1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT <br />LOCATIONS OF LIGHT FIXTURES AND CEILING -MOUNTED DEVICES. <br />2. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET E0.03 FOR <br />ADDITIONAL INFORMATION. <br />3. LOCATE CONCEALED LIGHTING CONTROL COMPONENTS IN NEAREST <br />ACCESSIBLE CEILING SPACE. PROVIDE RED -LINE COMPONENT <br />LOCATION ON RECORD DRAWINGS. <br />4. PROVIDE J-HOOKS ABOVE ACCESSIBLE CEILINGS FOR SUPPORT OF <br />LOW VOLTAGE LIGHTING CONTROLS CABLING. <br />5. PROVIDE UNSWITCHED HOT FROM CIRCUIT FEEDING LIGHTING IN <br />RESPECTIVE ROOM TO EXIT AND EMERGENCY LIGHTING FIXTURES <br />SHOWN. <br />6. NEW LIGHTING SHOWN AT EXISTING SPACES IS A LOAD REDUCTION <br />FROM EXISTING FIXTURES AND CONDITIONS. <br />7. SEE ED2.01 FOR ADDITIONAL INFORMATION REGARDING EXISTING <br />ROUGH -IN AND CIRCUITING. PROVIDE RACEWAY AND WIRING TO <br />EXTEND FROM EXISTING ROUGH -IN LOCATIONS AS INDICATED. <br />PROVIDE RACEWAY, WIRING, AND DEVICES AS SHOWN FOR DEVICES <br />ON NEW CIRCUITS SHOWN. <br />8. REFER TO E2.01A FOR ADDITIONAL LIGHTING CONTROLS ZONE <br />INFORMATION. <br />9. SEAL BUILDING PENETRATIONS WITH APPROVED WATER PROOFING <br />AND FIRE PROOFING MATERIALS. <br />10. ROUTE NEW RACEWAYS ABOVE ACCESSIBLE CEILING TO THE <br />EXTENT POSSIBLE. WHERE EXPOSED WITHIN INTERIOR SPACE, <br />PROVIDE V-700 BY WIREMOLD (OR APPROVED EQUAL) SURFACE <br />METAL RACEWAY, INCLUDING ALL FITTINGS AND OFFSETS TO <br />INSTALL DEVICES AT LOCATIONS SHOWN. PROVIDE SHOP DRAWING <br />SUBMITTAL INDICATING ALL NEW RACEWAYS FROM SOURCE PANELS <br />TO END OF LINE DEVICES. <br />11. CONNECT NEW LIGHT FIXTURES TO EXISTING CIRCUITS LION. <br />12. ALL INTERIOR LIGHTING IS CIRCUITED TO CIRCUIT 1 HN-1 UNLESS <br />OTHERWISE NOTED. PROVIDE NEW RACEWAY AND WIRING IN AREAS <br />OF RENOVATION UNLESS OTHERWISE NOTED. <br />13. CIRCUIT EBHN-7 IS A NET LOAD REDUCTION. PROVIDE RACEWAY <br />AND WIRING FOR EMERGENCY LIGHTING SEPARATE FROM NORMAL <br />LIGHTING. <br />FLAG NOTES <br />PROVIDE DIGITAL LIGHTING ROOM CONTROLLER(S) REQUIRED. <br />LOCATE ABOVE NEAREST ACCESSIBLE CEILING. SEE E2.01A FOR <br />ADDITIONAL INFORMATION. <br />2� PROVIDE CONDUIT AND CONDUCTORS AND CONNECT <br />UNSWITCHED HOT CONDUCTOR FROM NEAREST LUMINAIRE TO <br />EXIT SIGN INDICATED. <br />3� PROVIDE 20A EMERGENCY TRANSFER DEVICE AND LOCATE <br />ABOVE ACCESSIBLE CEILING. SEE DETAIL 2 ON THIS SHEET FOR <br />ADDITIONAL INFORMATION. <br />a, PROVIDE DIGITAL MANUAL DIMMING TYPE LIGHT SWITCH FOR <br />SPACE INDICATED. <br />PROVIDE EXTERIOR RATED SURFACE -MOUNTED PHOTOCELL. <br />PROVIDE CONDUIT AND WIRE TO CONNECT PHOTOCELL TO <br />ROOM CONTROLLER LOCATED IN ADJACENT CEILING SPACE. <br />PROGRAM CONTROLS TO TURN OFF EXTERIOR LIGHT FIXTURE <br />WHEN DAYLIGHT IS PRESENT. <br />INTERCEPT EXISTING UNSWITCHED EMERGENCY CIRCUIT AND <br />PROVIDE NEW RACEWAY AND CONDUCTORS TO SERVE <br />EMERGENCY LIGHT FIXTURES INDICATED ON THIS SHEET. <br />INSTALL LIGHT SWITCH(ES) AT EXISTING ROUGH -IN LOCATION <br />INDICATED. INTERCEPT EXISTING SWITCH LEG CONDUCTORS <br />AND PROVIDE CONDUIT AND CONDUCTORS FROM SWITCH TO <br />ROOM CONTROLLER(S) TO MAINTAIN EXISTING LIGHTING <br />CONTROLS WITHIN SPACE. <br />w <br />U) <br />00 <br />Uj <br />0— <br />h8ssetti <br />aidil[ects <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.bassettiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE <br />FULL SIZE <br />ZL REVISIONS DATE <br />BEZOS ACADEMY <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: <br />ISSUE DATE: <br />Jurisdiction Stamp Area <br />2018 <br />5/12/2022 <br />LIGHTING FLOOR <br />PLAN <br />E2.01 <br />coNT <br />M <br />ti <br />Cv <br />CV <br />O <br />N <br />rn <br />N <br />L <br />1_ _4_.._............................) <br />LIGHTING FLOOR <br />1/8" = 1'-0" <br />CONTROL <br />DEVICES FOR <br />LIGHTING WITHIN <br />THE ZONE/SPACE <br />0-10V CONTROLLED <br />DIMMING WHERE <br />REQUIRED <br />NORMAL SENSING <br />CIRCUIT <br />REFER TO <br />MANUFACTURER'S <br />WIRING DIAGRAM <br />FOR SPECIFICS <br />DEDICATED <br />RACEWAY SYSTEM <br />SHEET NOTES <br />1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT <br />LOCATIONS OF LIGHT FIXTURES AND CEILING -MOUNTED DEVICES. <br />2. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET E0.03 FOR <br />ADDITIONAL INFORMATION. <br />3. LOCATE CONCEALED LIGHTING CONTROL COMPONENTS IN NEAREST <br />ACCESSIBLE CEILING SPACE. PROVIDE RED -LINE COMPONENT <br />LOCATION ON RECORD DRAWINGS. <br />4. PROVIDE J-HOOKS ABOVE ACCESSIBLE CEILINGS FOR SUPPORT OF <br />LOW VOLTAGE LIGHTING CONTROLS CABLING. <br />5. PROVIDE UNSWITCHED HOT FROM CIRCUIT FEEDING LIGHTING IN <br />RESPECTIVE ROOM TO EXIT AND EMERGENCY LIGHTING FIXTURES <br />SHOWN. <br />6. NEW LIGHTING SHOWN AT EXISTING SPACES IS A LOAD REDUCTION <br />FROM EXISTING FIXTURES AND CONDITIONS. <br />7. SEE ED2.01 FOR ADDITIONAL INFORMATION REGARDING EXISTING <br />ROUGH -IN AND CIRCUITING. PROVIDE RACEWAY AND WIRING TO <br />EXTEND FROM EXISTING ROUGH -IN LOCATIONS AS INDICATED. <br />PROVIDE RACEWAY, WIRING, AND DEVICES AS SHOWN FOR DEVICES <br />ON NEW CIRCUITS SHOWN. <br />8. REFER TO E2.01A FOR ADDITIONAL LIGHTING CONTROLS ZONE <br />INFORMATION. <br />9. SEAL BUILDING PENETRATIONS WITH APPROVED WATER PROOFING <br />AND FIRE PROOFING MATERIALS. <br />10. ROUTE NEW RACEWAYS ABOVE ACCESSIBLE CEILING TO THE <br />EXTENT POSSIBLE. WHERE EXPOSED WITHIN INTERIOR SPACE, <br />PROVIDE V-700 BY WIREMOLD (OR APPROVED EQUAL) SURFACE <br />METAL RACEWAY, INCLUDING ALL FITTINGS AND OFFSETS TO <br />INSTALL DEVICES AT LOCATIONS SHOWN. PROVIDE SHOP DRAWING <br />SUBMITTAL INDICATING ALL NEW RACEWAYS FROM SOURCE PANELS <br />TO END OF LINE DEVICES. <br />11. CONNECT NEW LIGHT FIXTURES TO EXISTING CIRCUITS LION. <br />12. ALL INTERIOR LIGHTING IS CIRCUITED TO CIRCUIT 1 HN-1 UNLESS <br />OTHERWISE NOTED. PROVIDE NEW RACEWAY AND WIRING IN AREAS <br />OF RENOVATION UNLESS OTHERWISE NOTED. <br />13. CIRCUIT EBHN-7 IS A NET LOAD REDUCTION. PROVIDE RACEWAY <br />AND WIRING FOR EMERGENCY LIGHTING SEPARATE FROM NORMAL <br />LIGHTING. <br />FLAG NOTES <br />PROVIDE DIGITAL LIGHTING ROOM CONTROLLER(S) REQUIRED. <br />LOCATE ABOVE NEAREST ACCESSIBLE CEILING. SEE E2.01A FOR <br />ADDITIONAL INFORMATION. <br />2� PROVIDE CONDUIT AND CONDUCTORS AND CONNECT <br />UNSWITCHED HOT CONDUCTOR FROM NEAREST LUMINAIRE TO <br />EXIT SIGN INDICATED. <br />3� PROVIDE 20A EMERGENCY TRANSFER DEVICE AND LOCATE <br />ABOVE ACCESSIBLE CEILING. SEE DETAIL 2 ON THIS SHEET FOR <br />ADDITIONAL INFORMATION. <br />a, PROVIDE DIGITAL MANUAL DIMMING TYPE LIGHT SWITCH FOR <br />SPACE INDICATED. <br />PROVIDE EXTERIOR RATED SURFACE -MOUNTED PHOTOCELL. <br />PROVIDE CONDUIT AND WIRE TO CONNECT PHOTOCELL TO <br />ROOM CONTROLLER LOCATED IN ADJACENT CEILING SPACE. <br />PROGRAM CONTROLS TO TURN OFF EXTERIOR LIGHT FIXTURE <br />WHEN DAYLIGHT IS PRESENT. <br />INTERCEPT EXISTING UNSWITCHED EMERGENCY CIRCUIT AND <br />PROVIDE NEW RACEWAY AND CONDUCTORS TO SERVE <br />EMERGENCY LIGHT FIXTURES INDICATED ON THIS SHEET. <br />INSTALL LIGHT SWITCH(ES) AT EXISTING ROUGH -IN LOCATION <br />INDICATED. INTERCEPT EXISTING SWITCH LEG CONDUCTORS <br />AND PROVIDE CONDUIT AND CONDUCTORS FROM SWITCH TO <br />ROOM CONTROLLER(S) TO MAINTAIN EXISTING LIGHTING <br />CONTROLS WITHIN SPACE. <br />w <br />U) <br />00 <br />Uj <br />0— <br />h8ssetti <br />aidil[ects <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.bassettiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE <br />FULL SIZE <br />ZL REVISIONS DATE <br />BEZOS ACADEMY <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: <br />ISSUE DATE: <br />Jurisdiction Stamp Area <br />2018 <br />5/12/2022 <br />LIGHTING FLOOR <br />PLAN <br />E2.01 <br />