My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 SMITH AVE 2022 BEZOS ACADEMY Plans 2023-01-09
>
Address Records
>
SMITH AVE
>
3201
>
BEZOS ACADEMY
>
Plans
>
3201 SMITH AVE 2022 BEZOS ACADEMY Plans 2023-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 8:19:40 AM
Creation date
12/15/2022 2:55:50 PM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
3201
Tenant Name
BEZOS ACADEMY
Permit
B2205-053
PW2205-024
Year
2022
Notes
TI: (3) CLASSROOM PRESCHOOL ON 1ST FLOOR OF TRANSIT BLDG ; SITE WORK FOR BEZOS ACADEMY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NORMAL POWER <br />SOURCE <br />NEC 700 <br />SOURCE <br />VESTIBULE <br />C <br />M <br />ti <br />N <br />N <br />O <br />N <br />M <br />04 <br />1/8" = 1'-0" <br />0-10V CONTROLLED <br />DIMMING WHERE <br />REQUIRED <br />NORMAL SENSING <br />CIRCUIT <br />DEDICATED <br />RACEWAY SYSTEM <br />SF LOUNGE <br />LIGHTING CONTROL <br />SYSTEM TYPE WITHIN SPACE <br />X <br />ZONE # WITHIN SPACE CONTROL FUNCTION <br />P' ,, , RE PAff <br />i i <br />SYSTEM TYPE: <br />A = ANALOG STAND ALONE DEVICES <br />B = DIGITAL STAND ALONE DEVICES <br />CONTROL FUNCTIONS: <br />1 = ON/OFF <br />2 = ON/OFF/DIMMING <br />ZONE # WITHIN SPACE: <br />X = MATCH EXISTING ZONE(S) <br />GENERAL NOTE: <br />PROVIDE ANALOG CONTROLS WITH QUANTITY OF <br />CONTROL ZONE(S) MATCHING EXISTING LIGHTING <br />CONTROLS UNLESS OTHERWISE NOTED. <br />SPACE: <br />ALL FIXTURES IN A SPACE SHALL FUNCTION <br />TOGETHER VIA AUTOMATIC AND MANUAL CONTROL <br />INDICATED BELOW. <br />10 FC <br />LIGHT LEVEL SET POINT. FOOT CANDLE LEVELS <br />ARE AVERAGES FOR THE SPACE IDENTIFIED. <br />LIGHT LEVEL SEPARATION WITHIN THE SPACE <br />AUTOMATIC LIGHTING CONTROL ZONES <br />x/_X " <br />EXISTING ZONE - NIC <br />• EXISTING LIGHTING AND/OR CONTROLS TO REMAIN. SEE <br />L <br />SHEET ED2.01 AND SHEET E2.01 FOR ADDITIONAL <br />INFORMATION. <br />L L L— L I <br />'AUTOMATIC ON' OCCUPANCY SENSOR ZONE <br />LLLLI <br />L_ L L L_ I <br />LIGHT FIXTURES IN ROOM CONTROLLED VIA'AUTOMATIC <br />L— L_ L— L_ I <br />ON' /'AUTOMATIC OFF' OCCUPANCY SENSOR(S). <br />WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY <br />CODE: <br />• WHERE ADJACENT TO VERTICAL OR HORIZONTAL <br />FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING <br />OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND <br />TO THE QUANTITY OF INCOMING DAYLIGHT. <br />DAYLIGHTING ZONE 1 (PRIMARY) <br />W <br />A. DAYLIGHT CONTROL TYPE = OPEN/CLOSED LOOP <br />DAYLIGHTING ZONE 2 (SECONDARY) <br />S1 A. DAYLIGHT CONTROL TYPE = OPEN/CLOSED LOOP <br />r-r� <br />'VACANCY SENSOR ZONE <br />LIGHT FIXTURES ENABLED/DISABLED VIA WANUAL ON' / <br />'AUTOMATIC OFF' VACANCY SENSOR(S) AND SWITCH. <br />WHERE AUTOMATIC DAYLIGHT HARVESTING IS REQUIRED BY <br />CODE: <br />• WHERE ADJACENT TO VERTICAL OR HORIZONTAL <br />FENESTRATION, LIGHT FIXTURES WILL HAVE DAYLIGHTING <br />OVERRIDE CONTROLS THAT AUTOMATICALLY RESPOND <br />TO THE QUANTITY OF INCOMING DAYLIGHT. <br />+ + DAYLIGHTING ZONE 1 (PRIMARY) <br />_ + j�1 + A. DAYLIGHT CONTROL TYPE = OPEN/CLOSED LOOP <br />+ + <br />+ + DAYLIGHTING ZONE 2 (SECONDARY) <br />S1 A. DAYLIGHT CONTROL TYPE = OPEN/CLOSED LOOP <br />LINE VOLTAGE CONTROL <br />• WHERE ELECTRICAL, MECHANICAL, AND/OR TELECOM <br />EQUIPMENT IS LOCATED WITHIN ROOM, PROVIDE WANUAL <br />ON' /'MANUAL OFF' LINE VOLTAGE CONTROL. <br />T . • - • - @ :44 J� I =1 L1 k 0 <br />r---ti <br />i <br />ADDITIONAL MANUAL CONTROL <br />• DASHED OUTLINE REPRESENTS ADDITIONAL MANUAL <br />CONTROL ZONES WITHIN A SPACE. LIGHTING FIXTURES <br />WITHIN THE DASHED AREA SHALL BE MANUALLY <br />CONTROLLED TOGETHER. <br />• NOTE: IF A DASHED OUTLINE IS NOT INDICATED THEN ALL <br />LIGHTS WITHIN THE SPACE SHALL BE MANUALLY <br />CONTROLLED TOGETHER. <br />1 ,, <br />w <br />W <br />0— <br />b8ssetti <br />49rcilit, gets / <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.basseftiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE INCH <br />AT FULL SIZE <br />ZL REVISIONS DATE <br />BEZOS ACADEMY <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2018 <br />ISSUE DATE: 5/12/2022 <br />Jurisdiction Stamp Area <br />LIGHTING <br />CONTROL ZONE <br />FLOOR PLAN <br />E2.01A <br />