Me _ ► <br />PROJECT NAME: <br />BEZOS ACADEMY EVERETT TRANSIT STATION <br />PROPOSED WORK: <br />RENOVATION OF EVERETT TRANSIT STATION GROUND FLOOR TO ACCOMMODATE 3 CLASSROOM <br />PRESCHOOL FACILITY <br />APPLICABLE CODES: <br />CITY OF EVERETT MUNICIPAL CODE, 2021 EDITION. <br />INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, WASHINGTON STATE AMENDMENTS, WAG 51-52 <br />INTERNATIONAL EXISTING BUILDING CODE (IEBC), 2018 EDITION <br />INTERNATIONAL MECHANICAL CODE (IMC), 2018 EDITION, WASHINGTON STATE AMENDMENTS, WAC 51-52- <br />INTERNATIONAL FIRE CODE (IFC), 2018 EDITION, WASHINGTON STATE AMENDMENTS, WAC 51-54* <br />UNIFORM PLUMBING CODE (UPC) AND STANDARDS, 2018 EDITION, WAC 51-56 AND 51-57* <br />NATIONAL ELECTRIC CODE (NEC), 2018 EDITION,WASHINGTON STATE AMENDMENTS <br />WASHINGTON STATE ENERGY CODE (INTERNATIONAL ENERGY CONSERVATION CODE, 2018 EDITION, WAC <br />51-11) <br />2009 ICC/ANSI A117.1 <br />EXISTING BUILDING INFORMATION <br />YEAR BUILT: <br />2001 <br />TOTAL BUILDING AREA: <br />64,166 SF <br />STORIES: <br />4 STORIES ABOVE GRADE, 1 BELOW <br />BUILDING CODE: <br />UBC 1997 <br />EXISTING BUILDING OCCUPANCY: OFFICE - B (PRIMARY) <br />ASSEMBLY - A3 (MINOR) <br />CONSTRUCTION TYPE: <br />TYPE II FR, SPRINKLERED (UBC 1997) <br />OCCUPANCY SEPARATION: <br />NO REQUIREMENT PER UBC TABLE 3-13 <br />NO HAZARDOUS MATERIALS PER UBC TABLES 3-D OR 3-E <br />INTERNATIONAL EXISTING BUILDING CODE IEBC 2018 <br />CHAPTER 3: COMPLIANCE METHODS <br />SECTION 301.3.2 - WORK AREA COMPLIANCE METHOD; COMPLIANCE WITH THE APPLICABLE REQUIREMENTS OF CHAPTERS 6 <br />THROUGH 12. <br />CHAPTER 6: CLASSIFICATION OF WORK <br />601.2 WORK AREA <br />THE WORK AREA, AS DEFINED IN CHAPTER 2, SHALL BE IDENTIFIED ON THE CONSTRUCTION DOCUMENTS. REFER TO CODE <br />ANALYSIS PLANS. <br />603.1 LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR <br />WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. <br />603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH CHAPTER 7 AND 8 OF THE IEBC. <br />EXISTING GROUND LEVEL BUILDING AREA: 14,780SF <br />WORK AREA OF RECONFIGURED SPACE: 3,688.5 SF <br />WORK AREA IS 30% OF TOTAL BUILDING AREA <br />CHAPTER 8: ALTERATIONS LEVEL 2 <br />801.3 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS OF <br />THE IBC. <br />803.2.2 IN BUILDINGS WITH OCCUPANCY IN GROUP E WORK AREAS THAT HAVE EXITS OR CORRIDORS SERVING AN OCCUPANT <br />LOAD GREATER THAN 30 SHALL BE PROVIDED WITH AUTOMATIC SPRINKLER PROTECTION WHERE BOTH OF THE FOLLOWING <br />CONDITIONS OCCUR: <br />1. WORK AREA IS REQUIRED TO BE PROVIDED WITH AUTOMATIC SPRINKLER PROTECTION IN ACCORDANCE WITH THE IBC. <br />2. THE WORK AREA EXCEEDS 50 PERCENT OF THE FLOOR AREA. <br />THE WORK AREA DOES NOT EXCEED 50% OF THE FLOOR AREA. THE EXISTING BUILDING IS EQUIPPED WITH AUTOMATIC <br />SPRINKLER PROTECTION. <br />807.1 NEWLY INSTALLED ELECTRICAL REQUIREMENT AND WIRING RELATING WORK DONE IN ANY WORK AREA SHALL COMPLY <br />WITH ALL APPLICABLE REQUIREMENTS OF NFPA 70 EXCEPT AS PROVIDED FOR IN SECTION 807.3. <br />807.3.2 KITCHEN AREA SHALL HAVE NOT FEWER THAN TWO DUPLEX RECEPTACLE OUTLETS. <br />807.3.3 LAUNDRY AREAS SHALL HAVE NOT FEWER THAN ONE DUPLEX RECEPTACLE OUTLET LOCATED NEAR THE LAUNDRY <br />EQUIPMENT AND INSTALL ON AND INDEPENDENT CIRCUIT. <br />808.1 RECONFIGURED SPACES IN ANY WORK AREA SHALL BE PROVIDED WITH NATURAL OR MECHANICAL VENTILATION IN <br />ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE. <br />810.1 LEVEL 2 ALTERATION TO EXISTING BUILDINGS AREA PERMITTED WITHOUT REQUIRING THE ENTIRE BUILDING TO COMPLY <br />WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE. THE ALTERATIONS SHALL <br />CONFORM TO THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE AS THEY RELATE TO NEW <br />CONSTRUCTION ONLY. <br />CHAPTER 10: CHANGE OF OCCUPANCY <br />1001.2.2.1 PARTIAL CHANGE OF OCCUPANCY <br />WHERE THE OCCUPANCY CLASSIFICATION OR GROUP OF A PORTION OF AN EXISTING BUILDING IS CHANGED, SECTION 1011 <br />SHALL APPLY. <br />1005.1 MEANS OF EGRESS IN PORTIONS OF BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL <br />COMPLY WITH SECTION 1011. <br />1011.1.1 CHANGE OF OCCUPANCY WITHOUT SEPARATION. BUILDING WILL CONTINUE TO MEET REQUIREMENTS OF GROUP A <br />OCCUPANCY AS PREVIOUSLY PERMITTED. <br />1011.2.2 FIRE ALARM AND DETECTION SYSTEM TO BE PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE OF THE IBC <br />THROUGHOUT THE AREA WHERE THE CHANGE OF OCCUPANCY OCCURS. <br />1011.3 INTERIOR FINISH. IN AREAS OF THE BUILDING UNDERGOING THE CHANGE OF OCCUPANCY CLASSIFICATION. THE <br />INTERIOR FINISH OF WALLS AND CEILING SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE <br />FOR THE NEW OCCUPANCY CLASSIFICATION. <br />1011.4 OCCUPANCY A AND E ARE IN THE SAME HAZARD CATEGORIES IN REGARD TO LIFE SAFETY AND MEANS OF EGRESS. <br />1011.5 OCCUPANCY E IS IN A LOWER HAZARD CATEGORY THAN OCCUPANCY A IN REGARD TO HEIGHT AND AREA. <br />INTERNATIONAL BUILDING CODE 2018 <br />CHAPTER 3: USE AND OCCUPANCY CLASSIFICATIONS <br />CHANGE OF USE PROPOSED: <br />CHANGE OF USE FROM CAREER CENTER TO PRESCHOOL (GROUP E). <br />EXISTING: CAREER DEVELOPMENT CENTER A3 <br />PROPOSED: EDUCATIONAL, PRESCHOOL FACILITY E (3 TO 5 YEAR OLDS) <br />305.2 MORE THAN 5 CHILDREN OLDER THAN 2 1/2 YEARS OF AGE WHO RECEIVE EDUCATIONAL, SUPERVISION <br />OR PERSONAL CARE SERVICES FOR FEWER THAN 24 HRS./DAY.) <br />CHAPTER 5: ALLOWABLE HEIGHT AND BUILDING AREA <br />NO CHANGE TO HEIGHT, STORIES, OR BUILDING AREA <br />HEIGHT: 65' PER EVERETT LAND USE CODE FOR OCCUPIED SPACE. NO CHANGE PROPOSED. <br />70' PER EVERETT LAND USE CODE FOR MECH. SCREEN. NO CHANGE PROPOSED. <br />STORIES: 4. NO CHANGE PROPOSED. <br />BUILDING AREA: 64,166SF. NO CHANGE PROPOSED. <br />508.2.3 - NO SEPARATION IS REQUIRED BETWEEN ACCESSORY AND THE MAIN OCCUPANCY. <br />CHAPTER 6: TYPE OF CONSTRUCTION <br />EXISTING CONSTRUCTION: <br />iPloya7I=1« <br />TYPES OF CONSTRUCTION <br />FIRE RESISTIVE REQUIREMENTS (TABLE 6-A) <br />1. BEARING WALL - EXTERIOR <br />N/A <br />2. BEARING WALL - INTERIOR <br />N/A <br />3. NON -BEARING WALL - EXTERIOR <br />N/C <br />4. STRUCTURAL FRAME <br />2 <br />5. PARTITION - PERMANENT <br />1 <br />6. PARTITION - TENANT IMPROVEMENT <br />0 <br />7. SHAFT ENCLOSURE <br />2 <br />8. FLOORS & FLOOR - CEILING <br />2 <br />9. FLOORS & ROOF - CEILING <br />1 <br />10. EXTERIOR DOORS & WINDOWS <br />NIA <br />11. STAIRWAY CONSTRUCTION <br />REINFORCED CONCRETE IRON. OR STEEL PER 663.4 <br />NEW CONSTRUCTION <br />TABLE 601 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) <br />ELEMENT: <br />TYPE I-B RATING (MOST CLOSE TO EXISTING) <br />PRIMARY STRUCTURAL FRAME <br />2 <br />BEARING WALLS, EXTERIOR <br />2 <br />BEARING WALLS, INTERIOR <br />2 <br />NON -BEARING WALLS AND PARTITIONS, EXTERIOR <br />AS REQ'D BY TABLE 602 <br />NON -BEARING WALLS AND PARTITIONS, INTERIOR <br />0, OR AS REQ'D BY OTHER SECTIONS <br />FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS <br />2 <br />ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS <br />1 <br />TABLE 602 FIRE -RESISTANCE RATING - EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (HOURS) <br />OCCUPANCY E TYPE I-B <br />DISTANCE TO INTERIOR PROPERTY LINE: RATING <br />LESS THAN 30 FEET 1 <br />30 FEET OR GREATER 0 <br />CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES <br />NO FIRE BARRIER OR PARTITION IN THIS PROPOSED RENOVATION WORK. <br />CHAPTER 8: INTERIOR FINISHES <br />TABLE 803.13 INTERIOR FINISH REQUIREMENTS SPRINKLERED <br />INTERIOR EXIT STAIRWAYS AND EXIT PASSAGEWAYS: CLASS B <br />CORRIDORS: CLASS C <br />ROOMS: CLASS C <br />CHAPTER 9: FIRE PROTECTION SYSTEMS <br />906.2 PORTABLE FIRE EXTINGUISHERS: <br />TABLE 906.3: INSTALL PER NFPA 10, TYPE 2-A, 75 FEET MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER <br />907.2.3 GROUP E <br />A MANUAL FIRE ALARM SYSTEM THAT INITIATES THE OCCUPANT NOTIFICATION SIGNAL UTILIZING AN <br />EMERGENCE VOICE/ALARM COMMUNICATION SYSTEM MEETING THE REQUIREMENTS OF SECTIONS 907.5.2.2 <br />AND INSTALLED IN ACCORDANCE WITH SECTION 907.6 SHALL BE INSTALLED IN GROUP E OCCUPANCIES. <br />907.5.2.2 EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS REQUIRED BY THIS CODE SHALL BE <br />DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 72. <br />907.6 A FIRE ALARM SYSTEM SHALL BE INSTALLED AND MONITORED IN ACCORDANCE WITH NFPA 72. <br />CHAPTER 10: MEANS OF EGRESS <br />1004 TOTAL OCCUPANT LOAD <br />EXISTING: <br />CAREER CENTER 147 <br />(CLASSROOM, FACTOR 20, AS LAST PERMITTED PER UBC 10-A) <br />WORKSHOP <br />38 (ASSEMBLY, FACTOR 15, AS LAST PERMITTED PER UBC 10-A) <br />STORAGE 1 <br />(STORAGE, FACTOR 300, AS LAST PERMITTED PER UBC 10-A) <br />EXISTING TOTAL OCCUPANT LOAD 186 <br />PROPOSED: <br />PRESCHOOL CLASSROOMS 114 <br />HOS/ STAFF LOUNGE 3 <br />KITCHEN 1 <br />STORAGE, JANITOR'S 2 <br />PROPOSED TOTAL OCCUPANT LOAD 120 <br />NEW CONFIGURATION AND OCCUPANCY REDUCES LOAD <br />TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT <br />EDUCATIONAL CLASSROOM <br />20 NET <br />BUSINESS - OFFICES <br />150 GROSS <br />KITCHENS <br />200 GROSS <br />ACCESSORY STORAGE, MECHANICAL EQUIPMENT <br />300 GROSS <br />TABLE 1005.3.2 EGRESS WIDTH PER OCCUPANT SERVED <br />OTHER EGRESS COMPONENTS: <br />0.15" PER OCCUPANT (SPRINKLERED) <br />TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY <br />E OCCUPANCY WITH SPRINKLERS <br />75 FEET <br />TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE <br />E OCCUPANCY WITH SPRINKLERS <br />250 FEET <br />TABLE 1020.1 CORRIDOR FIRE RESISTANCE RATING OCCUPANT LOAD >30 <br />E OCCUPANCY WITH SPRINKLERS <br />0 HOUR <br />TABLE 1020.4 DEAD END CORRIDORS <br />E OCCUPANCY WITH SPRINKLERS <br />50 FEET MAX. <br />CHAPTER 29: PLUMBING SYSTEMS <br />TABLE 2902.1 <br />FOR GROUP E OCCUPANCIES: THE NUMBER OF OCCUPANTS SHALL BE DETERMINED BY USING A CALCULATION OF <br />100 SF GROSS BUILDING AREA PER STUDENT FOR THE MINIMUM OF PLUMBING FIXTURES. <br />PROJECT GROSS AREA 3,688 SF/100 = 37 <br />Plumbing Code Calculations <br />Refer to IBC 2018 Chapter 29 and Table 2902.1- "Minimum Number of Required Plumbing Fixtures" for specifics, exceptions, and footnotes. <br />OCCUPANCY: Education - E <br />OCCUPANTS: 37 <br />(19 MALE 19 FEMALE) <br />Educational facilities <br />WATER CLOSET <br />LAVATORIES <br />BATHTUBS OR <br />SHOWERS <br />DRINKING <br />FOUNTAINS <br />OTHER <br />MALE <br />FEMALE <br />MALE <br />FEMALE <br />REQUIRED: <br />1 <br />1 <br />1 <br />1 <br />- <br />1 <br />1 Service Sink <br />PROVIDED: <br />2 <br />1 3 <br />1 3 <br />2 <br />- <br />0 <br />1 1 <br />WASHINGTON STATE ENERGY CODE SEC 2018 <br />SECTION C503: ALTERATIONS <br />C503.1 GENERAL ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE <br />CODE FOR NEW CONSTRUCTION. ALTERATIONS TO AN EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF <br />SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS THEY RELATE TO NEW CONSTRUCTION WITHOUT REQUIRING <br />THE UNALTERED PORTIONS OF THE EXISTING BUILDING OR BUILDING SYSTEM TO COMPLY WITH THIS CODE. <br />ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS CONFORMING TO THE <br />PROVISIONS OF THIS CODE THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATIONS. <br />NO WORK TO EXISTING BUILDING ENVELOPE, REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR MECHANICAL <br />AND LIGHTING COMPLIANCE INFORMATION. <br />CODE PLAN LEGEND <br />3/32" = V-0" <br />NOTE: REFER TO WALL ASSEMBLY SCHEDULE SHEET FOR GENERAL <br />PARTITION CONSTRUCTION DETAILS. <br />DRAWING SYMBOL TYPE OF SEPARATION <br />- - - - _ MAXIMUM TRAVEL DISTANCE (MTD) <br />COMMON PATH <br />® 2 HR SEPARATION <br />......... 1 HR SEPARATION <br />EXTENT NOT IN SCOPE <br />r - - - - i <br />L - - - - J <br />EXTENT OF SCOPE OF WORK <br />9 � ci <br />F_ - -, 32" / 44" <br />711t <br />A- . <br />SE <br />1 SII <br />�iL..._ �_�. _ . C <br />CLASSROOM 3 <br />Occ Class: E��� O� <br />Area/occ: _20 _ _ 32" f 3211Ai <br />Area: 750 SF 1 AI <br />{ Occ Load: 38 v 0 <br />...� <br />L - - - - - - - - 4p>-♦3 '132" <br />32" A FE <br />�. <br />i <br />WARMING KITC <br />a <br />Occ Class: E r '= <br />Area/Occ: 200 <br />C � <br />Area: 178 SF E, H <br />Occ Load: 1 <br />32" / 32 <br />. = CORRIDOR <br />VESTIBULE ril 52 w; <br />�6V - J <br />,- <br />32" 3-71.. <br />F <br />BIOS - <br />Occ Class: B <br />Area/Occ: 150 <br />Area: 99 SF <br />Occ Load: 1 3: <br />STO. <br />Occ Class: E <br />Area/Occ: 300 <br />Area: 4� `! <br />Occ Load: 1, <br />50> OCCUPANT LOAD + EGRESS DIRECTION <br />DOOR WIDTH REQUIRED / DOOR WIDTH <br />32" / 72" PROVIDED <br />® EXIT SIGNAGE <br />FEC p FIRE EXTINGUISHER CABINET <br />FE FIRE EXTINGUISHER (WALL BRACKET) <br />RVICE <br />Occ Class: B <br />i TOTAL LOAD FOR <br />Area/Occ: '150GROUND <br />FLOOR NOT <br />Area: 203 SF ;I <br />INCLUDING T.I. <br />Occ oad: 2 <br />i OCCUPANT LOAD: <br />" / 32' <br />• 210 AS PREVIOUSLY <br />PERMITTED. ATRIUM <br />2 <br />LOBBY EXITS <br />b <br />38 <br />ENOUGH TO <br />I ACCOMODATE <br />�a <br />. <br />i <br />FEC BOTTLE 3�1a ,,........ <br />FILLER <br />3211 3 <br />i CLASSROOM 2 <br />CLASSROOM 1 <br />" / 32' <br />'i�CHILDREN TLT <br />Occ Class: E <br />Occ Class: E _ <br />Area/Occ: 20 <br />1S <br />_ _ .off <br />�r <br />� � <br />Area/Occ: 20 _ <br />� � Area: 749 SF <br />:I <br />Area: 747 SF <br />Occ Load: 38 <br />I <br />I Occ Load: 38 <br />- - - - - <br />- - <br />6 <br />LL-M_TD-115�------ <br />G <br />® w <br />b8i <br />settihitects <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.bassettiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE INCH <br />AT FULL SIZE <br />This document has been digitally signed <br />5428 <br />FARCHITECT <br />DANIEL MILES <br />STATE 4F WASHING <br />05/12/2022 3:04:30 <br />PM <br />REVISIONS DATE <br />Owner <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2018 <br />ISSUE DATE: 05/12/22 <br />Jurisdiction Stamp Area <br />CODE AND <br />AREA ANALYSIS <br />ODE <br />3/32" = 1 "4' <br />ANALYSIS PLAN <br />