Laserfiche WebLink
B <br />AD2.01 2 �� <br />w <br />0 <br />0 <br />T <br />O <br />O <br />0 <br />0 <br />r <br />I <br />DEMO KEYNOTES <br />aSAWCUT TRENCH IN SLAB, COORDINATE EXTENTS WITH <br />MECHANICAL DRAWINGS AND EXISTING SERVICES. <br />REMOVE DOOR AND FRAME <br />aPLUMBING PENETRATIONS TO BASEMENT LEVEL. COORDINATE <br />SIZING AND LOCATION WITH MECHANICAL DRAWINGS. <br />REMOVE ALL FLOORING AND BASE IN ROOM. <br />❑5 DEMO CASEWORK <br />❑6 REMOVE METAL PANEL ABOVE DOOR. PATCH & REPAIR TO <br />MATCH EXISTING PLASTER. SEE ELEVATION 9D/A6.01 <br />PARTIAL WALL DEMOLITION TO MODIFY PLUMBING, REFER TO <br />PLUMBING <br />REMOVE (E) DOOR, FRAME TO REMAIN. <br />❑9 (E) TERRAZZO FLOOR & WALL BASE TO REMAIN <br />MUMMMAMEXISTING TO REMAIN <br />DEMO EXISTING EQUIPMENT OR FIXTURE <br />— — — — DEMO EXISTING WALL <br />SLABS <br />� zSAW CUT TENCH C ORDINATE WITHIN <br />MECHANICAL <br />F -1 EXTENT NOT IN SCOPE OF INTERIOR <br />L - —1 RENOVATION. <br />DEMO PARTIAL ELEVATION - NORTH <br />1 /8" = 1'-011 <br />_ Level � <br />14'-0" V <br />OUND FLOOR /1 <br />0" <br />1. DRAWINGS ARE DIAGRAMMATIC IN NATURE. INFORMATION IS <br />PROVIDED TO DESCRIBE GENERAL LOCATIONS, ASPECTS AND AREA OF <br />EXISTING BUILDING ELEMENTS. EXISTING CONDITIONS, DIMENSIONS, <br />MATERIAL AND QUANTITIES MUST BE VERIFIED BY THE CONTRACTOR. <br />2. DIMENSIONS HAVE BEEN TAKEN FROM THE ORIGINAL CONSTRUCTION <br />DRAWINGS, ARCHITECT HAS NOT PERFORMED ACCURACY CHECK NOR <br />VERIFIED RELIABILITY OF THE INFORMATION CONTAINED THEREIN. <br />DELIVERY OF DRAWINGS IS NOT A SUBSTITUTE FOR CONTRACTORS <br />DUTY TO INVESTIGATE AND ASCERTAIN EXISTING CONDITIONS. <br />3. IN AREA TO BE DEMOLISHED, REMOVE EXISTING CONSTRUCTION IN ITS <br />ENTIRETY FROM FLOOR TO UNDERSIDE OF STRUCTURE UNLESS <br />NOTED OTHERWISE. <br />4. COORDINATE WITH MECHANICAL, ELECTRICAL, AND OTHER TRADE FOR <br />SIZE AND LOCATION OF ALL OPENINGS REQUIRED. <br />5. PATCH AND REPAIR ALL PENETRATIONS MADE DURING CONSTRUCTION <br />TO REINSTALL ANY RATED WALLS AND RATED SHEATHING AT ROOFING <br />TO EXTENT OF CURRENT CONDITIONS. <br />6. EXISTING MECHANICAL SYSTEM TO BE MODIFIED AS REQUIRED, <br />COORDINATE EXTENT OF DEMO WITH MECHANICAL DOCUMENTS. <br />7. REFER TO SPEC SECTION 024119 FOR ADDITIONAL DEMOLITION <br />REQUIREMENTS. <br />n.: 6 <br />24'4' 5'-6" 20'-0" 11'-6" 18'-6" 10'-0" <br />0' 2' 4' 8' <br />s <br />bassetti <br />architects <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.basseftiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE INCH <br />AT FULL SIZE <br />This document has been digitally signed <br />1428F— <br />EGIST,,p,1D�5 TECT' <br />DANIEL MILES <br />S'TA E QF WASHINGTON <br />05/12/2022 3:04:30 <br />PM <br />AREVISIONS DATE <br />Owner <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2018 <br />ISSUE DATE: 05/12/22 <br />Jurisdiction Stamp Area <br />DEMO FIRST <br />FLOOR PLAN <br />