Laserfiche WebLink
FLOOR OR GROUND SURFACES (ICC/ANSI SEC. 3 03)a <br />GENERAL: FLOOR OR GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. CHANGES IN LEVEL OF 1/4 INCH HIGH <br />MAX. SHALL BE PERMITTED TO BE VERTICAL. CHANGES IN LEVEL BETWEEN 1/4 INCH HIGH MIN. AND 1-1/2 INCH HIGH MAX. SHALL <br />BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE RAMPED AND SHALL <br />COMPLY WITH ICC/ANSI SECTION 405 OR 406. <br />WHEELCHAIR TURNING SPACE AND CLEAR SPACE (ICC /ANSI SEC. 3PAA 30, <br />CLEAR FLOOR OR GROUND SURFACE: FLOOR OR GROUND SURFACES OF A WHEELCHAIR TURNING SPACE SHALL HAVE A SLOPE NOT <br />STEEPER THAN 1:48. THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES MIN. BY 48 INCHES MIN. AND SHALL BE <br />POSITIONED FOR EITHER, FORWARD OR PARALLEL APPROACH TO AN ELEMENT. ONE FULL, UNOBSTRUCTED SIDE OF THE CLEAR FLOOR <br />OR GROUND SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER CLEAR FLOOR OR GROUND SPACE. <br />CIRCULAR SPACE: THE WHEELCHAIR TURNING SPACE SHALL BE NOT LESS THAN 60 INCHES DIAMETER MIN. WHEELCHAIR TURNING <br />SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES. <br />T-SHAPED SPACE: THE WHEELCHAIR TURNING SPACE MAY BE A T-SHAPED SPACE WITHIN A 60 INCH MIN. SQUARE WITH ARMS AND <br />BASE 36 INCHES WIDE MIN. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES MIN. IN EACH DIRECTION AND THE <br />BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MIN. T--SHAPED WHEELCHAIR TURNING SPACES SHALL BE PERMITTED TO <br />INCLUDE KNEE AND TOE CLEARANCES ONLY AT THE END OF EITHER THE BASE OR ONE ARM <br />DOORS: UNLESS OTHERWISE SPECIFIED, DOORS SHALL BE PERMITTED TO SWING INTO WHEELCHAIR TURNING SPACE. <br />ALCOVE CLEAR FLOOR SPACE: FORWARD APPROACH - THE WIDTH OF AN ALCOVE SHALL BE 36 INCHES MIN. WHERE THE DEPTH <br />EXCEEDS 24 INCHES. PARALLEL APPROACH - THE WIDTH OF AN ALCOVE SHALL BE 60 INCHES MIN. WHERE THE DEPTH EXCEEDS 15 <br />INCHES, <br />KNEE AND TOE CLEARANCE (]CC/ANSI SECS <br />TOE CLEARANCE: SPACE UNDER AN ELEMENT BETWEEN THE FLOOR OR GROUND AND 9 INCHES ABOVE THE FLOOR OR GROUND <br />SHALL BE TOE CLEARANCE. MAX. DEPTH IS PERMITTED TO EXTEND 25 INCHES MAX. UNDER AN ELEMENT AND 17 INCHES MIN. <br />BENEATH THE ELEMENT, TOE CLEARANCE SHALL BE 30 INCHES WIDE MIN. <br />R UNDER AN ELEMENT BETWEEN 9 INCHES AND 27 INCHES ABOVE THE FLOOR OR GROUND SHALL BE KNEE <br />KNEE CLEARANCE: SPACE D <br />CLEARANCE. KNEE CLEARANCE SHALL BE PERMITTED 10 EXTEND 25 INCHES MAX. UNDER AN ELEMENT AT 9 INCHES ABOVE THE <br />FLOOR OR GROUND. WHERE KNEE CLEARANCE IS REQUIRED BENEATH AN ELEMENT AS PART OF A CLEAR FLOOR OR GROUND SPACE, <br />THE KNEE CLEARANCE SHALL BE 11 INCHES DEEP MIN. AT 9 INCHES ABOVE THE FLOOR OR GROUND, AND 8 INCHES DEEP MIN. AT <br />27 INCHES ABOVE THE FLOOR OR GROUND. KNEE CLEARANCE SHALL BE 30 INCHES WIDE MIN. <br />i t , ■ti r i j It I I i i r r r i� rj ■ <br />REACH RANGES ICC/A SI SEC. �a8�: <br />UNOBSTRUCTED REACH: WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE <br />SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES MAX. AND THE LOW SIDE REACH SHALL BE 15 INCHES <br />MIN. ABOVE THE` FLOOR OR GROUND, EXISTING ELEMENTS SHALL BE PERMITTED AT 54 INCHES MAX. ABOVE THE FLOOR OR GROUND. <br />OBSTRUCTED HIGH FORWARD REACH: WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR OR GROUND <br />SPACE SHALL EXTEND BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER THE <br />OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 48 INCHES MAX. WHERE THE REACH DEPTH IS 20 INCHES MAX. WHERE THE <br />REACH DEPTH EXCEEDS 20 INCHES, THE HIGH FORWARD REACH SHALL BE 44INCHES MAX. AND THE REACH DEPTH SHALL BE 25 <br />INCHES MAX. <br />OBSTRUCTED HIGH SIDE REACH: WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN OBJECT AND <br />THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES MAX., AND THE DEPTH OF <br />THE OBSTRUCTION SHALL BE 24 INCHES MAX. THE HIGH SIDE REACH SHALL BE 48 INCHES MAX. FOR A REACH DEPTH OF 10 INCHES <br />MAX. WHERE THE REACH DEPTH EXCEEDS 10 INCHES, THE HIGH SIDE PEACH SHALL BE 46 INCHES MAX. FOR A REACH DEPTH OF 24 <br />INCHES MAX. <br />OPERABLE PARTS (IC%/ NSI SEC. a ): <br />HEIGHT: OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES. EXCEPT WHERE THE USE OF SPECIAL <br />EQUIPMENT DICTATES OTHERWISE, OR WHERE ELECTRICAL AND COMMUNICATIONS SYSTEMS RECEPTACLES ARE NOT NORMALLY <br />INTENDED FOR USE BY BUILDING OCCUPANTS. <br />OPERATION: OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR <br />TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAX. <br />ACCESSIBLE ROUTE (i�_C//NI SI SEC. ja is <br />ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: WALKING SURFACES WITH A SLOPE NOT <br />STEEPER THAN 1:20, DOORS AND DOORWAYS, RAMPS, CURB RAMPS, ELEVATORS, AND WHEELCHAIR (PLATFORM) LIFTS. ALL <br />COMPONENTS OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE APPLICABLE PORTIONS OF THIS STANDARD. <br />WALKING SURFACES (ICC/ANSI SEC. �2 : <br />SLOPE: TH RUNNING SLOPE OF WALKING SURFACES SHALL NOT B STEEPER THAN 1:20. THE CROSS SLOPE OF A WALKING <br />E L E L E L EE L E L <br />SURFACE SHALL NOT BE STEEPER THAN 1:48. <br />CLEAR WIDTH: CLEAR WIDTH OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH ICC/ANSI 403,5 CLEAR WIDTH AT TURN: WHERE AN <br />ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN OBJECT WHICH IS LESS THAN 48 INCHES WIDE, CLEAR WIDTHS SHALL <br />BE 42 INCHES MIN, APPROACHING THE TURN, 48 INCHES MIN. DURING THE TURN, AND 42 INCHES MIN. LEAVING THE TURN. <br />PASSING SPACE: AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES SHALL PROVIDE PASSING SPACES AT <br />INTERVALS OF 200 FEET MAX. THESE PASSING SPACES SHALL BE EITHER A 60 INCH BY 60 INCH MIN. SPACE, OR AN INTERSECTION <br />OF TWO WALKING SURFACES WHICH PROVIDE A T-SHAPED TURNING SPACE COMPLYING WITH ICC/ANSI SECTION 304. <br />MANUAL DOORS AND { _ <br />DOORWAYS ICC//�I _ t SEC. 44 <br />CLEAR WIDTH: DOORWAYS SHALL HAVE A CLEAR OPENING OF 32 INCHES MIN. CLEAR OPENING OF DOORWAYS WITH SWINGING DOORS <br />MEASURED B T TH FAC OF DOOR AND STOP WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 <br />SHALL BEBETWEEN E E E <br />INCHES DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES MIN. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING <br />WIDTH LOWER THAN 34 INCHES ABOVE THE FLOOR OR GROUND. PROJECTIONS INTO THE MIN. CLEAR OPENING WIDTH MORE THAN 34 <br />INCHES AND UP TO 80 INCHES ABOVE THE FLOOR OR GROUND ARE PERMITTED BUT SHALL NOT EXCEED 4 INCHES. <br />MANEUVERING CLEARANCES: REQUIRED DOOR MANEUVERING CLEARANCES SHALL NOT INCLUDE KNEE AND TOE CLEARANCE. <br />RECESSED DOORS: WHERE THE PLANE OF THE DOORWAY IS RECESSED MORE THAN 8 INCHES FROM THE PLANE OF THE WALL. <br />CLEARANCES FOR FRONT APPROACH SHALL BE PROVIDED. <br />TWO DOORS IN SERIES: DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES SHALL BE 48 INCHES MIN. PLUS THE WIDTH <br />OF ANY DOOR SWINGING INTO THE SPACE. THE SPACE BETWEEN THE DOORS SHALL PROVIDE A TURNING SPACE COMPLYING WITH <br />SECTION 304. <br />DOOR HARDWARE: HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE <br />THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO <br />OPERATE. SUCH HARDWARE SHALL BE 34 INCHES MIN. AND 48 INCHES MAX. ABOVE THE FLOOR OR GROUND. WHERE SLIDING DOORS <br />ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. <br />DOOR CLOSERS: DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO <br />MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MIN. <br />SPRING HINGES: DOOR SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR SHALL <br />MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MIN., <br />DOOR -OPENING FORCE: FIRE DOORS SHALL HAVE THE MIN. OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE <br />AUTHORITY. THE MAX. FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: <br />ri' r1 � i ■i r <br />rMai i r <br />THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE <br />DOOR IN A CLOSED POSITION. <br />DOOR SURFACE: DOOR SURFACES WITHIN 10 INCHES OF THE FLOOR OR GROUND MEASURED VERTICALLY SHALL BE A SMOOTH <br />SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN SUCH <br />SURFACE SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE <br />CAPPED. EXCEPT FOR SLIDING DOORS, TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE <br />TOP LEADING EDGE TAPERED AT NO LESS THAN 60 DEGREES FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 <br />INCH BOTTOM RAIL HEIGHT REQUIREMENT, AND DOORS WHICH DO NOT EXTEND TO WITHIN 10 INCHES OF THE FLOOR OR GROUND. <br />VISION LITES: DOORS AND SIDELITES ADJACENT TO DOORS CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING <br />THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE PANEL 43 INCHES MAX. ABOVE HE FLOOR OR GROUND. <br />RAMPS (ICC IANSI SEC. 405): <br />WALKING SURFACES ON ACCESSIBLE ROUTES WITH A RUNNING SLOPE STEEPER THAN 1:20 ARE RAMPS. <br />SLOPE: RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. CROSS SLOPE OF RAMP RUNS SHALL NOT BE <br />STEEPER THAN 1:48. <br />CLEAR WIDTH: THE CLEAR WIDTH OF A RAMP RUN SHALL BE 36 INCHES MIN_ HANDRAILS AND HANDRAIL SUPPORTS THAT ARE <br />PROVIDED ON THE RAMP RUN SHALL NOT PROJECT INTO THE REQUIRED CLEAR WIDTH OF THE RAMP RUN. THE RISE FOR ANY RAMP <br />RUN SHALL BE 30 INCHES MAX. OUTDOOR RAMPS AND APPROACHES TO RAMPS SHALL BE DESIGNED SO THAT WATER WILL NOT <br />ACCUMULATE ON WITHIN THE ROOM. WALKING SURFACES. <br />LANDINGS: RAMPS SHALL HAVE LANDINGS AT BOTTOM AND TOP OF EACH RUN. LANDINGS SHALL HAVE A SLOPE NOT STEEPER <br />THAN 1: 48 AND THE CLEAR WIDTH OF LANDINGS SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. <br />LANDING LENGTH SHALL BE 60 INCHES MIN. CLEAR. RAMPS THAT CHANGE DIRECTION AT LANDINGS SHALL HAVE A 60 INCH MIN, BY <br />60 INCH MIN. LANDING. <br />DOORWAYS: WHERE DOORWAYS ARE ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY ICC/ANSI SECTIONS <br />404.2.3 AND 404.3.2 SHALL BE PERMITTED TO OVERLAP THE LANDING AREA. WHERE A DOOR THAT IS SUBJECT TO LOCKING IS <br />LOCATED ADJACENT TO A RAMP LANDING, THE LANDING SHALL BE SIZED TO PROVIDE A TURNING SPACE COMPLYING WITH SECTION <br />304.3. <br />HANDRAILS: RAMPS WITH A RISE GREATER THAN 6 INCHES SHALL HAVE HANDRAILS COMPLYING WITH ICC/ANSI SECTION 505. <br />HANDRAILS SHALL NOT REDUCE THE REQUIRED CLEARANCES OF A RAMP RUN OR LANDING. EDGE PROTECTION SHALL BE PROVIDED <br />ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. THE FLOOR OR GROUND SURFACE OF THE RAMP RUN OR <br />LANDING SHALL EXTEND 12 INCHES MIN, BEYOND THE INSIDE FACE OF A RAILING COMPLYING WITH ICC/ANSI SECTION 505. <br />CURB OR BARRIER: A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4-INCH DIAMETER SPHERE <br />BELOW A HEIGHT OF 4 INCHES, <br />PROTRUDE INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR INTO PARKING SPACE ACCESS AISLES. THEY SHALL BE LOCATED <br />OR PROIECIED TO PREVENT THEIR OBSTRUCTION BY PARKED VEHICLES. HANDRAILS ARE NOT REQUIRED. <br />SIDES OF CURB RAMPS: WHERE PEDESTRIANS MUST WALK ACROSS A CURB RAMP, THE RAMP SHALL HAVE FLARED SIDES. SLOPE <br />OF FLARES SHALL NOT BE STEEPER THAN 1:10. WHERE THE WIDTH OF THE WALKING SURFACE AT THE TOP OF THE RAMP AND <br />PARALLEL TO THE RUN OF THE RAMP IS LESS THAN 48 INCHES WIDE, THE FLARED SIDES SHALL HAVE A SLOPE NOT STEEPER THAN <br />1:12. CURB RAMPS WITH RETURNED CURBS SHALL BE PERMITTED WHERE PEDESTRIANS WOULD NOT NORMALLY WALK ACROSS THE <br />RAMP. <br />COUNTER SLOPE: COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP OR <br />ACCESSIBLE ROUTE SHALL NOT BE STEEPER THAN 1:20. TRANSITIONS FROM RAMPS TO WALKS, GUTTERS OR STREETS SHALL BE AT <br />THE SAME LEVEL. <br />LOCATION AT MARKED CROSSINGS: CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, <br />EXCLUDING ANY FLARED SIDES. <br />LANDINGS: THE CLEAR LENGTH OF THE LANDING SHALL BE 36 INCHES MIN., WITH A CLEAR WIDTH AT LEAST AS WIDE AS THE CURB <br />RAMP, EXCLUDING FLARED SIDES LEADING TO THE LANDING. <br />DIAGONAL CURB RAMPS: DIAGONAL OR CORNER TYPE CURB RAMPS WITH RETURNED CURBS OR OTHER WELL-DEFINED EDGES SHALL <br />HAVE THE EDGES PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW. BOTTOMS OF DIAGONAL CURB RAMPS SHALL HAVE 48 INCHES <br />MIN. CLEAR SPACE, MEASURED PARALLEL TO THE RUNNING SLOPE. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS SHALL <br />PROVIDE THE 48 INCHES MIN. CLEAR SPACE WITHIN THE MARKINGS. DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A <br />SEGMENT OF STRAIGHT CURB 24 INCHES LONG MIN. ON EACH SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING. <br />ISLANDS: RAISED ISLANDS IN CROSSINGS SHALL BE A CUT -THROUGH LEVEL WITH THE STREET OR HAVE CURB RAMPS AT BOTH <br />SIDES, AND A LEVEL AREA 48 INCHES LONG MIN. BY 36 INCHES WIDE MIN., IN THE PART OF THE ISLAND INTERSECTED BY THE <br />CROSSING. <br />RING SPAC ES (ICC/ N I SEC. 5� <br />H H VEHICLE SPACE SIZE: ACCESSIBLE GAR AND VAN PARKING SPACES SHALL AVE AN ADJACENT ACCESS AISLE. CAR AND VAN <br />PARKING SPACES SHALL BE 96 INCHES MIN. WIDTH. <br />ACCESS AISLE: TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON ACCESS AISLE. PARKED VEHICLE OVERHANGS <br />SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE. ACCESS AISLES SERVING CAR PARKING SPACES SHALL BE 60 <br />INCHES WIDE MIN. ACCESS AISLES SERVING VAN PARKING SPACES SHALL BE 96 INCHES WIDE MIN, ACCESS AISLES SHALL EXTEND <br />THE FULL LENGTH OF THE PARKING SPACES THEY SERVE AND THEY SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. <br />FLOOR OR GROUND SURFACES: PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPES NOT STEEPER THAN 1:48. <br />ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE <br />VERTICAL CLEARANCE: PARKING SPACES FOR VANS SHALL HAVE A VERTICAL CLEARANCE OF 98 INCHES MIN. AT THE SPACE AND <br />ALONG THE VEHICULAR ROUTE THERETO. <br />IDENTIFICATION: WHERE ACCESSIBLE PARKING SPACES ARE REQUIRED TO BE IDENTIFIED BY SIGNS, THE SIGNS SHALL INCLUDE THE <br />A N 7 . SUCH SIGNS <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH ICC/ NSI SECTIO 03.6 SHALL BE 60 INCHES MIN. ABOVE C <br />THE FLOOR OR GROUND SURFACE OF THE PARKING SPACE, MEASURED TO THE BOTTOM OF THE SIGN. <br />PASSENGER LOADING ZONES (ICC/ANSI SEC. 5a }e <br />VEHICLE PULL-UP SPACE: PASSENGER LOADING ZONES SHALL PROVIDE AN ACCESS AISLE ADJACENT AND PARALLEL TO A VEHICLE <br />PULL-UP SPACE 96 INCHES MIN. WIDTH AND 20 FEET MIN. LENGTH. <br />ACCESS AISLES; ACCESS AISLES SHALL BE PART OF THE ACCESSIBLE ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS <br />AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE 60 INCHES WIDE MIN. AND 20 FEET LONG MIN. ACCESS AISLES <br />S SHALL BE <br />MARKED SO AS TO DISCOURAGE PARKING IN THEM. <br />FLOOR OR GROUND SURFACES: VEHICLE PULL-UP SPACES IN PASSENGER LOADING ZONES AND ACCESS AISLES SHALL HAVE <br />SURFACE SLOPES NOT STEEPER THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY <br />SERVE. <br />VERTICAL CLEARANCE: VERTICAL CLEARANCE OF 114 INCHES MIN. SHALL BE PROVIDED AT PASSENGER LOADING ZONES AND ALONG <br />VEHICLE ACCESS ROUTES TO SUCH AREAS FROM SITE ENTRANCES. <br />STAIRWAYS (ICC/ I§BSI C 91 . <br />TREADS AND RISERS: ALL STEPS ON A FUGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTH. <br />RISERS SHALL BE 4 INCHES HIGH MIN. AND 7 INCHES MAX. TREADS SHALL BE 11 INCHES DEEP MIN., MEASURED FROM RISER TO <br />RISER. OPEN RISERS SHALL NOT BE PERMITTED. STAIR TREAD SURFACE SHALL COMPLY WITH ICC/ANSI SECTION 302. <br />NOSINGS: THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1 /2 INCH MAX. NOSINGS THAT PROJECT <br />BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE <br />UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAX. FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL BE <br />1-1/2 INCHES MAX. BEYOND THE TREAD BELOW. <br />OUTDOOR CONDITIONS: OUTDOOR STAIRS AND OUTDOOR APPROACHES TO STAIRS SHALL BE DESIGNED SO THAT WATER WILL NOT <br />ACCUMULATE ON WALKING SURFACES. <br />HANDRAILS (IC C/ NSI SEC. 505): <br />LOCATION: HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. IN ASSEMBLY SEATING AREAS, HANDRAILS <br />SHALL NOT BE REQUIRED ON BOTH SIDES ALONG AISLE STAIRS, PROVIDED WITH A HANDRAIL EITHER AT THE SIDE OR WITHIN THE <br />AISLE. HANDRAILS SHALL NOT BE REQUIRED ON THE SIDES OF RAMPED AISLES SERVING SEATS. <br />CONTINUITY: HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS <br />ON SWITCHBACK OR DOGLEG STAIRS OR RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. <br />HEIGHT: TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MIN, AND 38 INCHES MAX. VERTICALLY ABOVE STAIR <br />NOSINGS, RAMP SURFACES, AND WALKING SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE STAIR NOSINGS AND <br />RAMP SURFACES. <br />CLEARANCE: CLEAR SPACE BETWEEN HANDRAIL AND WALL SHALL BE 1-1/2 INCHES MIN. <br />GRIPPING SURFACE: GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWEL POSTS, OTHER CONSTRUCTION <br />ELEMENTS, OR OBSTRUCTIONS. HANDRAIL BRACKETS OR BALUSTERS ATTACHED TO THE BOTTOM SURFACE OF THE HANDRAIL ARE <br />ALLOWED IF NOT MORE THAN 20 PERCENT OF THE HANDRAIL LENGTH IS OBSTRUCTED. SEE SECTION 505.6 FOR ADDITIONAL <br />HORIZONTAL PROJECTION EXCEPTIONS, HANDRAILS, AND ANY WALL OR OTHER SURFACES ADJACENT TO THEM, SHALL BE FREE OF <br />ANY SHARP OR ABRASIVE ELEMENTS. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS AND THEY SHALL HAVE A CIRCULAR <br />CROSS SECTION WITH AN OUTSIDE DIAMETER OF 1-1/4 INCH MIN. AND 2 INCHES MAX. <br />NON -CIRCULAR CROSS SECTIONS: HANDRAILS WITH OTHER SHAPES SHALL BE PERMITTED PROVIDED THEY HAVE A PERIMETER <br />DIMENSION OF 4 INCHES MIN. AND 6-1/4 INCHES MAX. AND PROVIDED THEIR LARGEST CROSS-SECTION DIMENSION IS 2--1/4 INCHES <br />MAX. <br />TOP EXTENSION AT STAIRS: AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR <br />12 INCHES MIN. BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. SUCH EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE <br />WALKING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. <br />BOTTOM EXTENSION AT STAIRS: AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR <br />FLIGHT FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. IF PROVIDED AT THE BOTTOM <br />OF A STAIR FLIGHT, A HORIZONTAL EXTENSION OF A HANDRAIL SHALL BE 12 INCHES LONG MIN. AND A HEIGHT EQUAL TO THAT OF <br />THE SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. SUCH EXTENSION SHALL RETURN TO A WALL, <br />GUARD, OR THE WALKING SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. <br />DRINKING FOUNTAINS (ICC/ANSI SEC. 602 <br />CLEAR FLOOR OR GROUND SPACE: A 30" X 48" CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED. WHERE A FORWARD <br />APPROACH IS PROVIDED, THE CLEAR FLOOR OR GROUND SPACE SHALL BE CENTERED ON THE UNIT AND SHALL INCLUDE KNEE AND <br />TOE CLEARANCE. WHERE A PARALLEL APPROACH IS PROVIDED, THE CLEAR FLOOR OR GROUND SPACE SHALL BE CENTERED ON THE <br />UNIT. <br />SPOUT HEIGHT AND LOCATION: SPOUT OUTLETS FOR WHEELCHAIR ACCESSIBILITY SHALL BE 36 INCHES MAX. ABOVE THE FLOOR OR <br />GROUND. SPOUT OUTLETS FOR STANDING PERSONS SHALL BE 38 INCHES MIN. AND 43 INCHES MAX. ABOVE FLOOR OR GROUND. <br />UNITS WITH A PARALLEL APPROACH SHALL HAVE THE SPOUT 3-1/2 INCHES MAX. FROM THE FRONT EDGE OF THE UNIT, INCLUDING <br />BUMPERS. UNITS WITH A FORWARD APPROACH SHALL HAVE THE SPOUT 15 INCHES MIN. FROM THE VERTICAL SUPPORT AND 5 <br />INCHES MAX. FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. OPERABLE PARTS SHALL COMPLY WITH ICC/ANSI SECTION <br />309 AND PROTRUDING UNITS SHALL COMPLY WITH ICC/ANSI SECTION 307. <br />TOILET AND BATHING DOOMS (ICC/ [BSI SEC. 603 AN �4�: <br />WHEELCHAIR TURNING SPACE: A CIRCULAR 60" DIAMETER WHEELCHAIR TURNING SPACE OR A "T" SHAPED TURNING SPACE <br />COMPLYING WITH ICC/ANSI SECTION 304 SHALL BE PROVIDED. <br />DOORS: DOORS SHALL NOT SWING INTO THE CLEAR FLOOR OR GROUND SPACE OR CLEARANCE FOR ANY FIXTURE EXCEPT WHERE THE <br />ROOM IS FOR INDIVIDUAL USE AND A 30" X 48" CLEAR FLOOR OR GROUND SPACE IS PROVIDED WITHIN THE ROOM BEYOND THE ARC <br />OF THE DOOR SWING. <br />LOCATION: THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE <br />OF THE WATER CLOSET SHALL BE 16 INCHES MIN. TO 18 INCHES MAX. FROM THE SIDE WALL OR PARTT110N. <br />WATER CLOSET CLEAR SPACE: CLEARANCE AROUND THE WATER CLOSET SHALL BE 60 INCHES MIN. MEASURED PERPENDICULAR <br />FROM THE SIDE WALL, AND 56 INCHES MIN. MEASURED PERPENDICULAR FROM THE REAR WALL. NO OTHER FIXTURES OR <br />OBSTRUCTIONS SHALL BE WITHIN THE WATER CLOSET CLEARANCE. <br />OVERLAP: THE CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB <br />BARS, TISSUE DISPENSERS, ACCESSIBLE ROUTES AND CLEAR FLOOR OR GROUND SPACE OR CLEARANCES AT OTHER FIXTURES AND <br />THE WHEELCHAIR TURNING SPACE, <br />WATER CLOSET HEIGHT AND CONTROLS: THE TOP OF WATER CLOSET SEATS SHALL BE 17 INCHES MIN. AND 19 INCHES MAX. ABOVE <br />THE FLOOR OR GROUND. SEATS SHALL NOT RETURN AUTOMATICALLY TO A LIFTED POSITION. FLUSH CONTROLS SHALL BE HAND <br />OPERATED OR AUTOMATIC. HAND -OPERATED FLUSH CONTROLS SHALL COMPLY WITH ICC/ANSI SECTION 309. <br />GRAB BARS: GRAB BARS SHALL BE PROVIDED ON THE REAP, WALL AND ON THE SIDE WALL CLOSEST TO THE WATER CLOSET. SIDE <br />WALL GRAB BAR SHALL BE 42 INCHES LONG MIN., 12 INCHES MAX. FROM THE REAR WALL AND EXTENDING 54 INCHES MIN, FROM <br />THE REAR WALL. IN ADDITION, A VERTICAL GRAB BAR 18 INCHES MIN. IN LENGTH SHALL BE MOUNTED WITH THE BOTTOM OF THE <br />BAR LOCATED BETWEEN 39 INCHES AND 41 INCHES ABOVE THE FLOOR WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39 <br />INCHES AND 41 INCHES FROM THE REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG MIN. AND EXTEND FROM THE <br />CENTER LINE OF THE WATER CLOSET A MIN, OF 12 INCHES ON THE SIDE CLOSEST TO THE WALL AND 24 INCHES MIN. ON THE <br />TRANSFER SIDE. <br />DISPENSERS: DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND 609.3. WHERE THE DISPENSER IS LOCATED ABOVE THE GRAB <br />BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 INCHES MIN. AND 36 INCHES MAX. FROM THE REAR <br />WALL. WHERE A, DISPENSER IS LOCATED BELOW THE GRAB BAR, THE OUTLET OF A DISPENSER SHALL BE LOCATED WITHIN AN AREA <br />24 INCHES MIN. AND 42 INCHES MAX. FROM THE REAR WALL. THE OUTLET OF THE DISPENSER SHALL BE LOCATED 18 INCHES MIN. <br />AND 48 INCHES MAX. ABOVE THE FLOOR. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR THAT DO NOT ALLOW <br />CONTINUOUS PAPER FLOW, <br />MIRRORS: MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAX. ABOVE THE FLOOR <br />OR GROUND. <br />COAT HOOKS AND SHELVES: COAT HOOKS PROVIDED WITHIN TOILET ROOMS SHALL ACCOMMODATE A FORWARD REACH OR SIDE REACH <br />COMPLYING WITH ICC/ANSI SECTION 308. WHERE PROVIDED, A FOLD -DOWN SHELF SHALL BE 40 INCHES MIN. AND 48 INCHES MAX. <br />ABOVE THE FLOOR OR GROUND. <br />60ER CLOSETS AND TOILET <br />COMPARTMENTS L CHILDREN'S S USE: <br />GENERAL: ACCESSIBLE WATER CLOSETS AND TOILET COMPARTMENTS PRIMARILY FOR CHILDREN'S USE SHALL COMPLY WITH SECTION <br />604.11 . <br />LOCATION: THE WATER CLOSET PRIMARILY FOR CHILDREN'S USE SHALL BE LOCATED WITH A WALL OR PARTITION TO THE REAR AND <br />TO ONE SIDE. THE CENTERLINE OF THE WATER CLOSET SHALL BE 12 INCHES (305 MM) MINIMUM AND 18 INCHES (455 MM) MAXIMUM <br />CC <br />i <br />_ i r <br />ri' <br />tr r <br />f <br />fir 1 1# r 1 i <br />f i ,�.r r rf.. i i r• i =� I �� i i <br />• �' 1 t i' i� i a r <br />ii r i rr i� i i •,"' <br />1- 1. r fill ,. 11 -9 111 Ill <br /># <br />WIN f 1 <br />r` <br />r r . , 21 <br />. , , r ■ r r. ■ . , f , r i r i <br />MINIMUM • r I •r , , . „ i Arr i• ,r , , I r , Ir <br />r <br />GRAB BADS (ICC/ANSI SEC. M9_ <br />r r■ r s - r ■ <br />; t c <br />1 rill <br />r t <br />1 <br />r i r <br />r r <br />x , e ; t �r <br />i rye r,■ r .► 2 � i � .i i �, i ,'i <br />t. � _-y. i"r f,r : it A. ,� y 1 it i r r.-. r i t.� ■a" i � �,... i.: .*r. I. <br />+ 1 4� tr f y I t Sri r t r rt t x i t i <br />f t # r 1 r r 1• ,� r f� r t i i i <br />_ry. r r r r •► r r r <br />1 t i i r i t # ,rr , • r <br />r i g •i 1 1 i,i r r, r;r. <br />i r 1 � i i t N r • r <br />tt, 'i 1 �`+r " � i • is i i : i ` rt , <br />il" '# r rt ,y ,■ i it 1 ri_ _i : tti r r li• • <br />■i r i 1 � ` r : :i i • i� r t' ■ t. •, y■rriy rrL r r <br />■ i:� ■f 't rk.r yr ■:i i ■ r..y ri., t- :r i'.. <br />__• 1 r Ir f rr1 r r - y 11 r <br />r , r i r r y r i:r • <br />i ri t .i r � I i ■1 s i" tr r _ � I "i <br />, i t r i r, i t�■ , rf r r t i <br />-� •- fir.. , r 1 � <br />r <br />r r r r i i <br />4" MAX. <br />t SEtc NO � I"— <br />*11 <br />(,I R WIDTH ANY nISTAVF <br />0 <br />W <br />m <br />a <br />i <br />ADA COMPLIANT UNISEX PESTROOM SIGNAGE <br />OR ADA GENDER -NEUTRAL RESTROOM <br />SIGNAGE <br />NOTE: <br />1 <br />T BACKGROUND, ALONG <br />PROVIDE SIGNS WITH RAISED AND BRAILLE CHARACTER SIG <br />NAGE WITH A HIGH CONTRAS TO THE B C L <br />R01 G t <br />WITH A WHITE INTERNATIONAL SYMBOL OF ACCESSIBILITY I.S.A. ON A BLUE BACKGROUND, MOUNT ON THE TOILET ROOM <br />ENTRANCE DOOR WALL ON THE LATCH SIDE OF THE DOOR. IF ADEQUATE ROOM IS NOT PROVIDED ON THE LATCH SIDE OF <br />THE DOOR, THE SIGNAGE IS REQUIRED TO BE PROVIDED ON THE NEAREST ADJACENT WALL. SIGNAGE IS ALLOWED ON THE <br />DOOR ONLY IF THE DOOR OPENS IN AWAY ON THE PUSH SIDE OF DOOR. <br />I.S.A. SIGNAGE SHALL BE MOUNTED AT 48"-60" AFF TO THE BRAILLE LETTERING ON THE SIGN. <br />IM <br />11 '1111111 51 aw, I <br />w <br />�M <br />SCALE: 1 /2 " 1'— J <br />REACH RANGES <br />SCALE- 3/8" 18=049 <br />2'-0" MAX. DEPTH <br />FOR MIN. CLEARANCE <br />2'-8" MIN. <br />3'-0" MIN. <br />x <br />I.B.C. SECTION 1013 REQUIRES THAT EXIT AND EXIT ACCESS <br />DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN <br />READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. <br />THE EXIT SIGNAGE IS REQUIRED TO HAVE A HIGH CONTRAST <br />WITH THE BACKGROUND WITH RAISED AND BRAILLE <br />CHARACTERS, A WHITE I.S.A. ON A BLUE BACKGROUND <br />SHALL BE INCLUDED FOR ACCESSIBLE DOORS. <br />EXIT SIGNAGE SHALL BE MOUNTED ON THE WALL ON THE <br />LATCH SIDE OF THE DOOR WITH 18" X 18" GROUND <br />CLEARANCE O.C. IF ADEQUATE ROOM IS NOT PROVIDED ON <br />THE LATCH SIDE OF THE DOOR, THE SIGNAGE IS REQUIRED <br />TO BE PROVIDED ON THE NEAREST ADJACENT WALL. <br />EXIT DOOR SIGNAGE SHALL BE MOUNTED BETWEEN 48" AND <br />60" A.F.F. MAX. TO THE BOTTOM OF BRAILLE CHARACTERS. <br />THE I.S.A. SIGNAGE SHALL BE MOUNTED IMMEDIATELY ABOVE <br />THE EXIT SIGN. AT NON -ACCESSIBLE ENTRANCES, DO NOT <br />INCLUDE THE INTERNATIONAL SIGN OF ACCESSIBILITY. <br />IT IS RECOMMENDED THAT THE CENTER OF THE SIGN BE SET <br />NO CLOSER THAN 9" FROM THE FRAME OF A DOOR SO A <br />VISUALLY IMPAIRED USER WOULD BE OUTSIDE OF THE DOOR <br />SWING WHILE STANDING IN FRONT OF THE SIGN. <br />- <br />REGISTERED <br />ARCHITECT <br />'AMIE TRE[V®A <br />S7ATE OF WASHINGTON <br />1 o rn"�C C <br />J -C �''-' O C C� 6 0��.�-+ 0+�+ <br />�° <br />-00 �E� a <br />a In a�� <br />� � rn N QUO 4J +, Cl qua <br />ate` oj-_0 o'Ev'Q_ <br />- 0) <br />Co <br />C•-c� o� n ya �a,o <br />O LI O O U C (-j U` O- <br />U U E > O O OfA U Q <br />, c <br />L U C U <br />F-- ��*- a p t• � z o a o � <br />a-ems^ay sU C in <br />N F. ;u� 'E ,� U U U <br />0 2'o -w-'o0 oCN� <br />�1)0E �yCI�E <br />c yam' ° v� <br />U O C C _ <br />v �-C .6C Ly" OS <br />d �"" O U o i <br />U �� L� <br />C�> z oa �t<0 E o.QU Cc � o a <br />�e <br />a <br />v <br />c �¢ <br />L^ <br />ICI <br />I <br />>_ <br />z <br />> <br />w <br />0 <br />z <br />Lu <br />w <br />--- <br />z <br />u) L11 <br />w <br />• r' <br />1 i <br />f <br />ICC Al 17.1-2009 GENERAL <br />CODE NOTES & DETAILS <br />CURB RAMPS (IMANSI SEC,a j(J <br />CURB RAMPS SHALL BE 36 INCHES WIDE MIN., EXCLUSIVE OF FLARED SIDES. CURB RAMPS AND THEIR SIDE FLARES SHALL NOT <br />SCALE: NTT <br />