15 SW EVERETT MALL WAY 2022 NOVEL EYES Plans 2023-01-09
>
Address Records
>
SW EVERETT MALL WAY
>
15
>
NOVEL EYES
>
Plans
>
15 SW EVERETT MALL WAY 2022 NOVEL EYES Plans 2023-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 8:03:03 AM
Creation date
12/15/2022 3:29:36 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
15
Tenant Name
NOVEL EYES
Permit
B2203-038
Year
2022
Notes
2306 SF OFFICE REMODEL TO EYE CLINIC
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LC.C� 404 DOORS AND DOORWAYS: <br />404.1 GENERAL. DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 404. <br />FRONT <br />APPROACH - PUSH AND PULL SIDES <br />_ - <br />i CLEAR I <br />I APPROACH <br />404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS AND MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY <br />I FLOOR i <br />: SPACE I <br />WITH THE REQUIREMENTS OF SECTION 404.2 <br />I I <br />404.2.1 DOUBLE -LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES <br />z <br />I I <br />: <br />SHALL COMPLY WITH SECTIONS 404.2.2 AND 404.2.3 <br />I <br />' <br />404.2.2 CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES MIN. CLEAR OPENING WIDTH OF <br />ic7 <br />' <br />1 <br />DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND STOP, NTH THE DOOR <br />1'-6" I <br />OPEN 90 DEGREES, OPENINGS, BOORS AND DOORWAYS WITHOUT DOORS MORE THAN 24 INCHES IN DEPTH SHALL PROVIDE <br />A CLEAR OPENING WIDTH OF 36 INCHES MIN. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWERI <br />MIN.A <br />THAN 34 INCHES ABOVE THE FLOOR. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND SO INCHES <br />-_-_-----_ <br />ABOVE THE FLOOR SHALL NOT EXCEED 4 INCHES. <br />---- - <br />CLEAR I <br />EXCEPTIONS. <br />i FLOOR X <br />1. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MIN. ABOVE THE FLOOR. <br />; SPACE , <br />I I I <br />2. IN ALTERATIONS, A PROJECTION OF 5/8 INCH MAX. INTO THE REQUIRED CLEAR OPENING WIDTH SHALL BE <br />PERMITTED FOR THE LATCH SIDE STOP. <br />I I I <br />I I I <br />404.2.3.1 FLOOR SURFACE, FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT STEEPER <br />i APPROACH <br />I I I <br />THAN 1:48 AND SHALL COMPLY WITH SECTION 302 <br />I I I <br />404.2.4 THRESHOLDS AT DOORWAYS: IF PROVIDED. THRESHOLD AT DOORWAYS SHALL BE 1/2 INCH MAX. IN HEIGHT. <br />NOTE: <br />X = 1'-0" (MIN.) IF DOOR HAS <br />RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 302 AND 303. <br />BOTH <br />A CLOSER AND A LATCH <br />A <br />LIMANEUVERING CLEARANCES AT MANUAL SWINGING DOORS <br />LATCH APPROACH - PUSH SIDE <br />--------_----- CLEAR <br />FLOOR <br />SPACEI <br />I 1 <br />APPROACH <br />_ _ I <br />1 <br />I I <br />--------------- <br />NOTE: Y= 3'-6" MIN.; Y=4'-O" MIN. IF <br />DOOR HAS A CLOSER <br />I ----------------------CLEAR- <br />FLOOR <br />SPACES <br />I <br />C <br />I --------CLEAR <br />FLOOR <br />SPACEI <br />I ! <br />I I <br />I I <br />O <br />I <br />LATCH APPROACH - PULL SIDE <br />-------------------71CLEAR <br />FLOOR <br />SPACE <br />APPROACH <br />I <br />i <br />2'-0" <br />i <br />/ // —"---------- <br />NOTE: Y= 4'-0" MIN.; Y=4'-6" MIN. IF <br />DOOR HAS A CLOSER <br />ID <br />HINGE APPROACH - PUSH SIDE <br />®-_.------------- CLEAR <br />FLOOR <br />SPACEI <br />I I I <br />X* <br />APPROACH <br />X i 22" MIN. <br />I I i <br />NOTE: Y= 3'-6" MIN.; Y=4'-O" MIN. IF <br />DOOR HAS A CLOSER; <br />X = 12" MIN. IF BOTH CLOSER AND <br />LATCH ARE PROVIDED <br />SCALE: 3/8" 1 -0" <br />ICC/ANSI SEC, 404 <br />60" CLEAR MIN. <br />60" CLEAR MIN. <br />60" CLEAR MIN. <br />EXISTING CONCRETE FLOOR TILE <br />A FRONT APPROACH <br />LVT TO EXISTING CONCRETE <br />-----------9 <br />CLEAR I <br />FLOOR <br />SPACEI <br />APPROACH <br />INSTALL TILE PER MFR RECOMMENDATIONS <br />00 <br />I i <br />I I <br />INSTALL SCHLUTER®SCHIENE TRANSITION STRIP <br />\ <br />\ <br />I ----------- <br />BETWEEN VINYL & TILE. <br />_ <br />00 <br />32" CLR MIN <br />SIZE: DETERMINED BY TILE THICKNESS <br />i <br />\ <br />FINISH: BRUSHED NICKEL/ANODIZED ALUMINUM (VFY) <br />\ <br />Av <br />UA <br />FLOAT VINYL TO BE FLUSH <br />r <br />\\ <br />o00 <br />co <br />WITH TILE HEIGHT <br />`- - <br />POCKET SIDE APPROACH _ <br />LATCH SIDE APPROACH <br />/ <br />54" MIN <br />24" MIN <br />e--_---_-_-_ <br />-----__, <br />%r------------------ <br />CLEAR I <br />I <br />CLEAR I <br />VINYL SUBFLOOR TILE <br />z <br />I FLOOR <br />: SPACE: <br />i <br />i <br />FLOOR <br />SPACEI <br />VINYL TO TILE <br />APPROACH a <br />i i <br />z <br />_ <br />i <br />i APPROACH <br />I I <br />I I <br />I <br />I <br />I <br />I <br />DB <br />I I <br />1 I <br />i <br />I - - - - <br />/ <br />I <br />I <br />E=] <br />�=. 3 <br />32" CLR MIN <br />L 32" CLR MIN <br />INSTALL CARPET PER MFR RECOMMENDATI <br />Iq <br />INSTALL SCHLUTER@SCHIENE TRANSITION STRIP <br />BETWEEN VINYL & CARPET. <br />CLEARANCE <br />AT TWO <br />DOORS IN SERIES <br />MANEUVERING <br />CLEARANCES AT <br />SLIDING POCKET / BARN DOORS_ <br />SIZE. DETERMINED BY CARPET HEIGHT <br />- <br />FINISH: BRUSHED NICKEL/ANODIZED ALUMINUM (VFY) <br />SCALE' 3/8" = 1 -131" <br />ICC/ARM SEC. 404 <br />SCALE. 3/8" = 1'-O" <br />ICC/ANSI SEC. 404 <br />FLOAT VINYL TO BE FLUSH <br />WITH CARPET HEIGHT -----\ , <br />VINYL —' SUBFLOOR —' CARPET <br />VINYL TO CARPET <br />•.. <br />t r-r r01rIII' � <br />INSTALL SCHLUTER-SCHIENE TRANSITION STRIP <br />BETWEEN CARPET & TILE. <br />SIZE: DETERMINED BY TILE THICKNESS <br />FINISH: BRUSHED NICKEL/ANODIZED ALUMINUM (VFY) <br />CARPET SUBFLOOR -L7 <br />CARPET TO TILE <br />TILE <br />FLOORING <br />OfRY 3 <br />TRANSITIONS <br />THRESHOLD <br />FLOOR FINISH <br />D <br />2 <br />NOTE: <br />INTERIOR AND EXTERIOR THRESHOLDS SHALL BE NO HIGHER THAN 1 /2 <br />INCH ABOVE THE ADJACENT FLOOR LEVELS. EACH EXPOSED EDGE OF <br />THRESHOLDS SHALL BE BEVELED OR SLOPED AT AN ANGLE NOT TO <br />EXCEED 45 DEGREES SO THAT NO VERTICAL CHANGE OF ELEVATION <br />EXCEEDS 1 /4 INCH. <br />INSULATE HOT WATER PIPES <br />AND DRAIN TO PREVENT <br />CONTACT <br />LINE OF REQUIRED <br />CLEARANCE <br />X <br />x <c <br />z � � <br />-I <br />KNEE CLEARANCE 8" MIN. 6" MAX. TOE CLEARANCE <br />1'-5" MIN. DEPTH <br />1'-5" MIN. <br />rCLEAR-_----___-- <br />z I FLOOR <br />SPACE <br />P <br />i I <br />cv I <br />IL_--------------- <br />4'-0" MIN. i'-7" MAX. <br />LAVATORY CLEARANCES <br />1'-5" TO 1'-7" EQUIPMENT PERMITTED <br />/ IN SHADED AREA <br />KNEE CLEARANCE 8" MIN. -/ �- 6" MAX. TOE CLEARANCE <br />2'-0" MAX. <br />r. r� 1'-5" TO 1'-7" <br />CLEAR------ - - - - <br />2 ' FLOOR <br />SPACE <br />I <br />I I <br />cv I <br />IL--------------- <br />4'-0" MIN. <br />DRINKING <br />TyR-{ FOUNTAIN <br />ks>n CLEARANCES <br />U N v O Vi 6�^ C C N v v "- O <br />3 N <br />-om �Eo0a��N �� 3 <br />a o a0 ��s <br />_ <br />0'D aQ;po <br />•0. a O� r1 <br />> - i- a 0-� � <br />f C1 C GJ U C F_ C O <br />„- <br />+-p m C <br />C •- QJ O '� o- y d � U O <br />p p 0 N U 4 a O• C <br />> o o 0 m 5 <br />p <br />i-- a`*- a a t • moo %," L <br />Q' J U O Op U <br />Z p o pn o p C m O <br />E i m E U <br />0' Z9 NO i C C C Y„ B N m m C m <br />C2. � �.0 m ate. Q- O T � i C 'O L U U. <br />U ¢aR-z `oa)' 3¢ E Eau o a- <br />soy; <br />1 <br />r� <br />i <br />3pai <br />S' <br />sf <br />y �1r <br />n <br />\_1 <br />w <br />�® <br />> <br />ly <br />od <br />� <br />w� <br />L <br />0 <br />z <br />> <br />z <br />(t)w <br />-- <br />W <br />Lo <br />REVISIONS <br />NO. DATE <br />BY <br />Al <br />/2\ <br />0 <br />A <br />A <br />A <br />ISSUE <br />DATES <br />DESIGN APPROVAL: <br />PERMIT SUBMITTAL: <br />PERMIT RECEIVED: <br />BID ROCS: <br />CONSTR. ROCS: <br />24"x36" SCALE: <br />AS NO E-ED <br />PLOT DATE: <br />01-20-2022 <br />CAD FILE: <br />21-1 76 AO.x <br />JOB NUMBER: <br />21-176 <br />CHECKED: <br />DRAWN: <br />B P <br />STATUS: <br />PERMIT SET <br />IC;C Al17.1=2009 GENERAL <br />CODE DIET AILS <br />SCALD: NTS <br />ICC/ANSI SECTION 302 & 303 <br />SCALE: /8" = 1 -0" <br />ICC/ANSI SEC. 304, 305 & 306 <br />F <br />SCALE: 3/8" = V-13" ICC/ANSI SEC. 304, 305 & 306 <br />