LC.C� 404 DOORS AND DOORWAYS: <br />404.1 GENERAL. DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 404. <br />FRONT <br />APPROACH - PUSH AND PULL SIDES <br />_ - <br />i CLEAR I <br />I APPROACH <br />404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS AND MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY <br />I FLOOR i <br />: SPACE I <br />WITH THE REQUIREMENTS OF SECTION 404.2 <br />I I <br />404.2.1 DOUBLE -LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES <br />z <br />I I <br />: <br />SHALL COMPLY WITH SECTIONS 404.2.2 AND 404.2.3 <br />I <br />' <br />404.2.2 CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 INCHES MIN. CLEAR OPENING WIDTH OF <br />ic7 <br />' <br />1 <br />DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND STOP, NTH THE DOOR <br />1'-6" I <br />OPEN 90 DEGREES, OPENINGS, BOORS AND DOORWAYS WITHOUT DOORS MORE THAN 24 INCHES IN DEPTH SHALL PROVIDE <br />A CLEAR OPENING WIDTH OF 36 INCHES MIN. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWERI <br />MIN.A <br />THAN 34 INCHES ABOVE THE FLOOR. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND SO INCHES <br />-_-_-----_ <br />ABOVE THE FLOOR SHALL NOT EXCEED 4 INCHES. <br />---- - <br />CLEAR I <br />EXCEPTIONS. <br />i FLOOR X <br />1. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MIN. ABOVE THE FLOOR. <br />; SPACE , <br />I I I <br />2. IN ALTERATIONS, A PROJECTION OF 5/8 INCH MAX. INTO THE REQUIRED CLEAR OPENING WIDTH SHALL BE <br />PERMITTED FOR THE LATCH SIDE STOP. <br />I I I <br />I I I <br />404.2.3.1 FLOOR SURFACE, FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT STEEPER <br />i APPROACH <br />I I I <br />THAN 1:48 AND SHALL COMPLY WITH SECTION 302 <br />I I I <br />404.2.4 THRESHOLDS AT DOORWAYS: IF PROVIDED. THRESHOLD AT DOORWAYS SHALL BE 1/2 INCH MAX. IN HEIGHT. <br />NOTE: <br />X = 1'-0" (MIN.) IF DOOR HAS <br />RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 302 AND 303. <br />BOTH <br />A CLOSER AND A LATCH <br />A <br />LIMANEUVERING CLEARANCES AT MANUAL SWINGING DOORS <br />LATCH APPROACH - PUSH SIDE <br />--------_----- CLEAR <br />FLOOR <br />SPACEI <br />I 1 <br />APPROACH <br />_ _ I <br />1 <br />I I <br />--------------- <br />NOTE: Y= 3'-6" MIN.; Y=4'-O" MIN. IF <br />DOOR HAS A CLOSER <br />I ----------------------CLEAR- <br />FLOOR <br />SPACES <br />I <br />C <br />I --------CLEAR <br />FLOOR <br />SPACEI <br />I ! <br />I I <br />I I <br />O <br />I <br />LATCH APPROACH - PULL SIDE <br />-------------------71CLEAR <br />FLOOR <br />SPACE <br />APPROACH <br />I <br />i <br />2'-0" <br />i <br />/ // —"---------- <br />NOTE: Y= 4'-0" MIN.; Y=4'-6" MIN. IF <br />DOOR HAS A CLOSER <br />ID <br />HINGE APPROACH - PUSH SIDE <br />®-_.------------- CLEAR <br />FLOOR <br />SPACEI <br />I I I <br />X* <br />APPROACH <br />X i 22" MIN. <br />I I i <br />NOTE: Y= 3'-6" MIN.; Y=4'-O" MIN. IF <br />DOOR HAS A CLOSER; <br />X = 12" MIN. IF BOTH CLOSER AND <br />LATCH ARE PROVIDED <br />SCALE: 3/8" 1 -0" <br />ICC/ANSI SEC, 404 <br />60" CLEAR MIN. <br />60" CLEAR MIN. <br />60" CLEAR MIN. <br />EXISTING CONCRETE FLOOR TILE <br />A FRONT APPROACH <br />LVT TO EXISTING CONCRETE <br />-----------9 <br />CLEAR I <br />FLOOR <br />SPACEI <br />APPROACH <br />INSTALL TILE PER MFR RECOMMENDATIONS <br />00 <br />I i <br />I I <br />INSTALL SCHLUTER®SCHIENE TRANSITION STRIP <br />\ <br />\ <br />I ----------- <br />BETWEEN VINYL & TILE. <br />_ <br />00 <br />32" CLR MIN <br />SIZE: DETERMINED BY TILE THICKNESS <br />i <br />\ <br />FINISH: BRUSHED NICKEL/ANODIZED ALUMINUM (VFY) <br />\ <br />Av <br />UA <br />FLOAT VINYL TO BE FLUSH <br />r <br />\\ <br />o00 <br />co <br />WITH TILE HEIGHT <br />`- - <br />POCKET SIDE APPROACH _ <br />LATCH SIDE APPROACH <br />/ <br />54" MIN <br />24" MIN <br />e--_---_-_-_ <br />-----__, <br />%r------------------ <br />CLEAR I <br />I <br />CLEAR I <br />VINYL SUBFLOOR TILE <br />z <br />I FLOOR <br />: SPACE: <br />i <br />i <br />FLOOR <br />SPACEI <br />VINYL TO TILE <br />APPROACH a <br />i i <br />z <br />_ <br />i <br />i APPROACH <br />I I <br />I I <br />I <br />I <br />I <br />I <br />DB <br />I I <br />1 I <br />i <br />I - - - - <br />/ <br />I <br />I <br />E=] <br />�=. 3 <br />32" CLR MIN <br />L 32" CLR MIN <br />INSTALL CARPET PER MFR RECOMMENDATI <br />Iq <br />INSTALL SCHLUTER@SCHIENE TRANSITION STRIP <br />BETWEEN VINYL & CARPET. <br />CLEARANCE <br />AT TWO <br />DOORS IN SERIES <br />MANEUVERING <br />CLEARANCES AT <br />SLIDING POCKET / BARN DOORS_ <br />SIZE. DETERMINED BY CARPET HEIGHT <br />- <br />FINISH: BRUSHED NICKEL/ANODIZED ALUMINUM (VFY) <br />SCALE' 3/8" = 1 -131" <br />ICC/ARM SEC. 404 <br />SCALE. 3/8" = 1'-O" <br />ICC/ANSI SEC. 404 <br />FLOAT VINYL TO BE FLUSH <br />WITH CARPET HEIGHT -----\ , <br />VINYL —' SUBFLOOR —' CARPET <br />VINYL TO CARPET <br />•.. <br />t r-r r01rIII' � <br />INSTALL SCHLUTER-SCHIENE TRANSITION STRIP <br />BETWEEN CARPET & TILE. <br />SIZE: DETERMINED BY TILE THICKNESS <br />FINISH: BRUSHED NICKEL/ANODIZED ALUMINUM (VFY) <br />CARPET SUBFLOOR -L7 <br />CARPET TO TILE <br />TILE <br />FLOORING <br />OfRY 3 <br />TRANSITIONS <br />THRESHOLD <br />FLOOR FINISH <br />D <br />2 <br />NOTE: <br />INTERIOR AND EXTERIOR THRESHOLDS SHALL BE NO HIGHER THAN 1 /2 <br />INCH ABOVE THE ADJACENT FLOOR LEVELS. EACH EXPOSED EDGE OF <br />THRESHOLDS SHALL BE BEVELED OR SLOPED AT AN ANGLE NOT TO <br />EXCEED 45 DEGREES SO THAT NO VERTICAL CHANGE OF ELEVATION <br />EXCEEDS 1 /4 INCH. <br />INSULATE HOT WATER PIPES <br />AND DRAIN TO PREVENT <br />CONTACT <br />LINE OF REQUIRED <br />CLEARANCE <br />X <br />x <c <br />z � � <br />-I <br />KNEE CLEARANCE 8" MIN. 6" MAX. TOE CLEARANCE <br />1'-5" MIN. DEPTH <br />1'-5" MIN. <br />rCLEAR-_----___-- <br />z I FLOOR <br />SPACE <br />P <br />i I <br />cv I <br />IL_--------------- <br />4'-0" MIN. i'-7" MAX. <br />LAVATORY CLEARANCES <br />1'-5" TO 1'-7" EQUIPMENT PERMITTED <br />/ IN SHADED AREA <br />KNEE CLEARANCE 8" MIN. -/ �- 6" MAX. TOE CLEARANCE <br />2'-0" MAX. <br />r. r� 1'-5" TO 1'-7" <br />CLEAR------ - - - - <br />2 ' FLOOR <br />SPACE <br />I <br />I I <br />cv I <br />IL--------------- <br />4'-0" MIN. <br />DRINKING <br />TyR-{ FOUNTAIN <br />ks>n CLEARANCES <br />U N v O Vi 6�^ C C N v v "- O <br />3 N <br />-om �Eo0a��N �� 3 <br />a o a0 ��s <br />_ <br />0'D aQ;po <br />•0. a O� r1 <br />> - i- a 0-� � <br />f C1 C GJ U C F_ C O <br />„- <br />+-p m C <br />C •- QJ O '� o- y d � U O <br />p p 0 N U 4 a O• C <br />> o o 0 m 5 <br />p <br />i-- a`*- a a t • moo %," L <br />Q' J U O Op U <br />Z p o pn o p C m O <br />E i m E U <br />0' Z9 NO i C C C Y„ B N m m C m <br />C2. � �.0 m ate. Q- O T � i C 'O L U U. <br />U ¢aR-z `oa)' 3¢ E Eau o a- <br />soy; <br />1 <br />r� <br />i <br />3pai <br />S' <br />sf <br />y �1r <br />n <br />\_1 <br />w <br />�® <br />> <br />ly <br />od <br />� <br />w� <br />L <br />0 <br />z <br />> <br />z <br />(t)w <br />-- <br />W <br />Lo <br />REVISIONS <br />NO. DATE <br />BY <br />Al <br />/2\ <br />0 <br />A <br />A <br />A <br />ISSUE <br />DATES <br />DESIGN APPROVAL: <br />PERMIT SUBMITTAL: <br />PERMIT RECEIVED: <br />BID ROCS: <br />CONSTR. ROCS: <br />24"x36" SCALE: <br />AS NO E-ED <br />PLOT DATE: <br />01-20-2022 <br />CAD FILE: <br />21-1 76 AO.x <br />JOB NUMBER: <br />21-176 <br />CHECKED: <br />DRAWN: <br />B P <br />STATUS: <br />PERMIT SET <br />IC;C Al17.1=2009 GENERAL <br />CODE DIET AILS <br />SCALD: NTS <br />ICC/ANSI SECTION 302 & 303 <br />SCALE: /8" = 1 -0" <br />ICC/ANSI SEC. 304, 305 & 306 <br />F <br />SCALE: 3/8" = V-13" ICC/ANSI SEC. 304, 305 & 306 <br />