CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS 4 <br />CONDITIONS PRIOR TO CONSTRUCTION, <br />ALL BEAMS 4 HEADERS TO BE 4x10 DF2, UN.O. <br />PROVIDE SOLID BLOCKINGo OVER SUPPORTS. <br />PROVIDE FIRE BLOCKING -a ALL PLUMBING PENETRATIONS. <br />WINDOW 8 DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. <br />WINDOW HEADERS a 6'-10" ABOVE 5U5-FLOOR, U.N.O. <br />(2), (N) OR 61"f. INDICATES NUMBER OF 2x STUDS OR POST <br />REQUIRED a POINT LOAD <br />ALL WOOD IN CONTACT WITH GONG. TO BE PRESSURE TREATED. <br />EXTERIOR WALLS TO BE 2x6 STUDS 6 16" O.C. w/ R-21 INSULATION, U.N.O. <br />INSTALL SII`1P5ON CONC. TO WOOD HOLDOWN5 1 1/2" FROM CORNERS <br />8 WINDOW ROUGH OPENINGS, ALSO SEE MANUFACTURER'S SPECS. <br />SMOKE DETECTORS: * SHALL BE 110 V INTERCONNECTED W/ BATTERY <br />BACKUP * SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS <br />AND SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING <br />CHANGE GREATER THAN 24" <br />TUBUS & SHOWERS: <br />FIREBLOCKING IN ACCORDANCE W/ <br />SECTION R602.8, IRC. <br />LIMIT SHOWER FLOW TO 2. 5 G.P.M. <br />WALLS SHALL BE WATERPROOF TO A <br />MIN. 70" ABOVE DRAIN INLET. <br />ALL GLAZING INCLUDING WINDOWS WITHIN <br />60" OF STANDING/WALKING; SURFACE <br />SHALL BE SAFETY GLASS. <br />AFIRE" BLOCKING & DRAFT STOPPLING <br />FIRE BLOCKING; PER IBC SEC. -11_1.2.1,-111.2.i,1406.2.4. <br />DRAFT STOPPING PER IBC 111.4 8 717.3 <br />fer <br />LIMITS OF'-22"�LG 1IGHT <br />ATTI <br />-4 _ I - T 111- <br />Eie I I --_1 REMOVE FLL SIZE <br />R �_/ 0 ;r SINK AND REPLACE <br />LIT - WITH STD AR SI K <br />r\ -- <br />\ <br />te \ - REM VE EX STING ANGE/ VEN <br />AND ABANDON DEDICATED 220V 0J <br />CIRCUIT PER INSPECTOR'S <br />RECOMMENDATION <br />MICROWAVE ABOVE TO REMAIN <br />VENT MICROWAVE 0/5 THRU ROOF <br />BUILT IN 5T <br />L -- — <br />Syr <br />ATTIC FLOOIR PLAN <br />SCALE = 1/4"= 1'-0" 019 S.F. TOTAL PERIMETER <br />548 S.F. W/ CLG'S ia 6'-10" MIN. <br />© Copyright 2021 <br />DEFINITIVE DESIGN GROUP <br />TH ESE DRAWINGS ARE COPYRIGHTED MATERIAL <br />AND MAY NOT RE COPIED OR REDRAWN WITHOUT <br />THE EXPRESSED WRITTEN CONSENT OF DEFINITIVE <br />DESIGN GROUP. THESE DRAWINGS ARE LIMITED TO <br />A SPECIFIC PROJECT FOR PERSONS NAMED HEREIN <br />AND FOR THE CONSTRUCTION OF ONE BUILDING. <br />ANY OTHER USE OR REUSE IS STRICTLY <br />PROHISITED WITHOUT WRITTEN CONSENT FROM <br />DEFINITIVE DESIGN GROUP. <br />---------- EXPOSE ELECTRICAL WIRING; <br />FOR INSPECTION <br />— - — - — - — ELECTRICAL INSPECTION AGGESS <br />LOCATED ATTIC SPACE OF UPPER FLR <br />�7>esign Gry up_ <br />�hh,�r�,cr'L�y� rhhSortin�I�w��rcent <br />22922 /4th P/ace CUest <br />BothSll, aU96hington 98.C2I <br />206 355 6/40 Jmp.ddcsggmai/.com <br />OTOF FLOOR BATHROOM AND KITCHEN REMODEL <br />-DATE OF CONSTRUCTION UNKNOWN <br />-PERMIT UNKNOWN <br />-NO ROUCxN-IN PLUMBING OR ELECRfC,4L DONE <br />-ALL FIXTURES AND/OR ELECTRICAL TRIM IHAS <br />BEEN REPLACED IN -KIND <br />THE 220v CIRCUIT FOR THE RANGE/OVEN ON THE <br />UPPER FLOOR SHALL BE ABANDONED AND <br />TERMINATED AT WALL OUTLET AND SERVICE PANEL <br />LOCATED IN BASEMENT <br />Bruce and Kathi <br />Habenicht <br />2/625 42nd Drive NE <br />Arlington, UTA 98223 <br />425 238 9847 <br />CITY OF EVERETT <br />Case # CE20-0376 <br />Project Address <br />31018th Street <br />Everett WA 98201 <br />Note: <br />All non -permitted electrical work done to <br />date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies, or must be removed, <br />in its entirety. <br />All non -permitted mechanical work done <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permitted approval by any & all <br />governing agencies. See drawings for <br />specific items to be inspected and <br />permitted. <br />All non -permitted plumbing work done <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies. <br />Any subsequent work required, with all <br />disciplines shown above, shall be <br />completed by a licensed contractor in <br />that specific discipline. <br />Date A rIl 5th, 2=1 <br />Drawn JMP <br />�1,eSt <br />A2.3-1 <br />Parc,el No. 00612300000300 <br />