3101 8TH ST 2020 Plans 2022-12-15
>
Address Records
>
8TH ST
>
3101
>
Plans
>
3101 8TH ST 2020 Plans 2022-12-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2022 4:30:57 PM
Creation date
12/15/2022 4:17:19 PM
Metadata
Fields
Template:
Address Document
Street Name
8TH ST
Street Number
3101
Permit
BW2007-006
Year
2020
Notes
SFR REMODEL TO REMEDIATE WORK WITHOUT PERMITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS 4 <br />CONDITIONS PRIOR TO CONSTRUCTION, <br />ALL BEAMS 4 HEADERS TO BE 4x10 DF2, UN.O. <br />PROVIDE SOLID BLOCKINGo OVER SUPPORTS. <br />PROVIDE FIRE BLOCKING -a ALL PLUMBING PENETRATIONS. <br />WINDOW 8 DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. <br />WINDOW HEADERS a 6'-10" ABOVE 5U5-FLOOR, U.N.O. <br />(2), (N) OR 61"f. INDICATES NUMBER OF 2x STUDS OR POST <br />REQUIRED a POINT LOAD <br />ALL WOOD IN CONTACT WITH GONG. TO BE PRESSURE TREATED. <br />EXTERIOR WALLS TO BE 2x6 STUDS 6 16" O.C. w/ R-21 INSULATION, U.N.O. <br />INSTALL SII`1P5ON CONC. TO WOOD HOLDOWN5 1 1/2" FROM CORNERS <br />8 WINDOW ROUGH OPENINGS, ALSO SEE MANUFACTURER'S SPECS. <br />SMOKE DETECTORS: * SHALL BE 110 V INTERCONNECTED W/ BATTERY <br />BACKUP * SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS <br />AND SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING <br />CHANGE GREATER THAN 24" <br />TUBUS & SHOWERS: <br />FIREBLOCKING IN ACCORDANCE W/ <br />SECTION R602.8, IRC. <br />LIMIT SHOWER FLOW TO 2. 5 G.P.M. <br />WALLS SHALL BE WATERPROOF TO A <br />MIN. 70" ABOVE DRAIN INLET. <br />ALL GLAZING INCLUDING WINDOWS WITHIN <br />60" OF STANDING/WALKING; SURFACE <br />SHALL BE SAFETY GLASS. <br />AFIRE" BLOCKING & DRAFT STOPPLING <br />FIRE BLOCKING; PER IBC SEC. -11_1.2.1,-111.2.i,1406.2.4. <br />DRAFT STOPPING PER IBC 111.4 8 717.3 <br />fer <br />LIMITS OF'-22"�LG 1IGHT <br />ATTI <br />-4 _ I - T 111- <br />Eie I I --_1 REMOVE FLL SIZE <br />R �_/ 0 ;r SINK AND REPLACE <br />LIT - WITH STD AR SI K <br />r\ -- <br />\ <br />te \ - REM VE EX STING ANGE/ VEN <br />AND ABANDON DEDICATED 220V 0J <br />CIRCUIT PER INSPECTOR'S <br />RECOMMENDATION <br />MICROWAVE ABOVE TO REMAIN <br />VENT MICROWAVE 0/5 THRU ROOF <br />BUILT IN 5T <br />L -- — <br />Syr <br />ATTIC FLOOIR PLAN <br />SCALE = 1/4"= 1'-0" 019 S.F. TOTAL PERIMETER <br />548 S.F. W/ CLG'S ia 6'-10" MIN. <br />© Copyright 2021 <br />DEFINITIVE DESIGN GROUP <br />TH ESE DRAWINGS ARE COPYRIGHTED MATERIAL <br />AND MAY NOT RE COPIED OR REDRAWN WITHOUT <br />THE EXPRESSED WRITTEN CONSENT OF DEFINITIVE <br />DESIGN GROUP. THESE DRAWINGS ARE LIMITED TO <br />A SPECIFIC PROJECT FOR PERSONS NAMED HEREIN <br />AND FOR THE CONSTRUCTION OF ONE BUILDING. <br />ANY OTHER USE OR REUSE IS STRICTLY <br />PROHISITED WITHOUT WRITTEN CONSENT FROM <br />DEFINITIVE DESIGN GROUP. <br />---------- EXPOSE ELECTRICAL WIRING; <br />FOR INSPECTION <br />— - — - — - — ELECTRICAL INSPECTION AGGESS <br />LOCATED ATTIC SPACE OF UPPER FLR <br />�7>esign Gry up_ <br />�hh,�r�,cr'L�y� rhhSortin�I�w��rcent <br />22922 /4th P/ace CUest <br />BothSll, aU96hington 98.C2I <br />206 355 6/40 Jmp.ddcsggmai/.com <br />OTOF FLOOR BATHROOM AND KITCHEN REMODEL <br />-DATE OF CONSTRUCTION UNKNOWN <br />-PERMIT UNKNOWN <br />-NO ROUCxN-IN PLUMBING OR ELECRfC,4L DONE <br />-ALL FIXTURES AND/OR ELECTRICAL TRIM IHAS <br />BEEN REPLACED IN -KIND <br />THE 220v CIRCUIT FOR THE RANGE/OVEN ON THE <br />UPPER FLOOR SHALL BE ABANDONED AND <br />TERMINATED AT WALL OUTLET AND SERVICE PANEL <br />LOCATED IN BASEMENT <br />Bruce and Kathi <br />Habenicht <br />2/625 42nd Drive NE <br />Arlington, UTA 98223 <br />425 238 9847 <br />CITY OF EVERETT <br />Case # CE20-0376 <br />Project Address <br />31018th Street <br />Everett WA 98201 <br />Note: <br />All non -permitted electrical work done to <br />date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies, or must be removed, <br />in its entirety. <br />All non -permitted mechanical work done <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permitted approval by any & all <br />governing agencies. See drawings for <br />specific items to be inspected and <br />permitted. <br />All non -permitted plumbing work done <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies. <br />Any subsequent work required, with all <br />disciplines shown above, shall be <br />completed by a licensed contractor in <br />that specific discipline. <br />Date A rIl 5th, 2=1 <br />Drawn JMP <br />�1,eSt <br />A2.3-1 <br />Parc,el No. 00612300000300 <br />