CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS 8 <br />CONDITIONS PRIOR TO CONSTRUCTION. <br />ALL BEAMS 8 HEADERS TO BE 4x10 DF2, UN.O: <br />PROVIDE SOLID BLOCKING OVER SUPPORTS. <br />PROVIDE FIRE BLOCKING a ALL PLUMBING PENETRATIONS. <br />WINDOW 8 DOORS ARE SHOWN B NOTED AS NOMINAL SIZES. <br />WINDOW HEADERS a �o'-10" ABOVE SUB -FLOOR, U.N.O. <br />(®), (K) OR SIM. INDICATES NUMBER OF 2x STUDS OR POST <br />REQUIRED a POINT LOAD <br />ALL WOOD IN CONTACT WITH GONG. TO BE PRESSURE TREATED. <br />EXTERIOR WALLS TO BE 2x6 STUDS a 16" O.G. w/ R-21 INSULATION, U.N.O <br />INSTALL SIMPSON CONC. TO WOOD HOLDOWNS 1 1/2" FROM CORNERS ATTIC <br />((� 1C1f ®®)f� 1f� 1f J� <br />4 WINDOW ROUGH OPENINGS, ALSO SEE MANUFACTURER'S SPECS. A JL IC JL L J/N JC JL A <br />SMOKE DETECTORS: * SHALL BE 110 V INTERCONNECTED W/ BATTERY SGALE = 1/4 I'-0" ale S.F. TOTAL PERIMETER <br />BACKUP * SHALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS 548 S.F. W/ CLG'S e r '-10" MIN <br />AND SHALL BE INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING <br />CHANGE GREATER THAN 24" <br />TUBS & SHOWE'11Z.Sa <br />FIREBLOCKING IN ACCORDANCE W/ <br />SECTION R602.a, IRC. <br />LIMIT SHOWER FLOW TO 2. 5 G.P.M <br />WALLS SHALL BE WATERPROOF TO A <br />MIN. 10" ABOVE DRAIN INLET. <br />ALL GLAZING INCLUDING WINDOWS WITHIN <br />60' OF STANDING/WALKING SURFACE <br />SHALL BE 5AFE7`r' GLASS. <br />l�l\C� Il�l'�.�\Il <br />FIRE BLOCKING PER 1BC SEC_ -111.2.1,111.21,1406.2.4. <br />DRAFT 5TOPPING PER IBC 111.4 6 117.3 <br />© COP09M2021 <br />DEFINITIVE DESIGN GROUP <br />THESE DRAWINGS ARE COPYRIGHTED MATERIAL <br />AND MAY NOT BE COPIED OR REDRAWN WITHOUT <br />THE EXPRESSED WRITTEN CONSENT OF DEFINITIVE <br />DESIGN GROUP. THESE DRAWINGS ARE LIMITED TO <br />ASPECIFIC PROJECT FOR PERSONS NAMED HEREIN <br />AND FOR THE CONSTRUCTION OF ONE BUILDING, <br />ANY OTHER USE OR REUSE 15 STRICTLY <br />PROHIBITED WITHOUT WRITTEN CONSENT FROM <br />DEFINITIVE DESIGN GROUP, <br />— — — — — — — — — — EXPOSE ELECTRICAL WIRING <br />FOR INSPECTION <br />— - — - — - — ELECTRICAL INSPECTION ACCESS <br />LOCATED ATTIC SPACE OF UPPER FLR <br />I L�'esign Gr1c� up <br />f-nhanced,Zye�ftyle-Mh SdG�_M4,%%tivieyrt <br />22922 /4th Place Ulest <br />BOthe// 6Ua6hingtOn 9,60V <br />206 355 6/40 imp_ddcsggmailcom <br />OTOP FLOOR BATHROOM AND KITCHEN REMODEL <br />-DATE OF CONSTRUCTION UNKNOWN <br />-PERMIT UNKNOWN <br />-NO ROUGH -IN PLUMBING OR ELECRIGAL DONE <br />-ALL FIXTURES AND/OR ELECTRICAL TRIM HAS <br />BEEN REPLACED IN -KIND <br />THE 220V CIRCUIT FOR THE RANGE/OVEN ON THE <br />UPPER FLOOR SHALL BE ABANDONED AND <br />TERMINATED AT WALL OUTLET AND SERVICE PANEL <br />LOCATED IN BASEMENT <br />Bruce and Kathi <br />Habenicht <br />2/625 42ncY DriIre NE <br />,Arlington, U.IA 98223 <br />425 238 9847 <br />CITY OF EVERETT <br />Case # CE20-0376 <br />Project Address <br />31018th Street <br />Everett WA 98201 <br />Note: <br />All non -permitted electrical work done to <br />date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies, or must be removed, <br />in its entirety. <br />All non -permitted mechanical work done <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permitted approval by any & all <br />governing agencies. See drawings for <br />specific items to be inspected and <br />permitted. <br />All non -permitted plumbing work done <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies. <br />Any subsequent work required, with all <br />disciplines shown above, shall be <br />completed by a licensed contractor in <br />that specific discipline. <br />Date April 5th, 2021 <br />Drawn Ev JMP <br />S1Teet <br />A2.3 <br />/I. OT,0 fI R <br />