INSTALL (2) ELECTRICAL VEHICLE CHARGING STATIONS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />1. A NATIONALLY RECOGNIZED TESTING LABORATORY SHALL <br />LIST ALL EQUIPMENT IN COMPLIANCE WITH ART110.3 <br />2. ALL EXTERIOR EQUIPMENT SHALL BE RAIN TIGHT AND <br />APPROVED FOR USE IN WET CONDITIONS <br />3, ALL CONDUCTORS SHALL BE <br />PROVIDED WITH STRAIN RELIEF UPON ENTRY INTO ENCLOSURES. <br />4. EACH UNGROUNDED CONDUCTOR SHALL BE IDENTIFIED BY <br />PHASE AND SYSTEM PER ART 210.5 <br />5, ALL METALLIC COMPONENTS <br />SHALL BE GROUNDED VIA ELECTRIC GROUNDING CONDUCTORS <br />6. CHARGING UNITS ARE EQUIPPED WITH AN INTEGRATED <br />CONTACTOR TO PREVENT BACK FEEDING OF POWER TO THE <br />SOURCE <br />7. CONTRACTOR TO FIELD VERIFY MAIN FEED BREAKER <br />SUPPORTING DISTRIBUTION PANEL IS APPROPRIATELY SIZED TO <br />SUPPORT THE LOAD, CONTRACTOR SHALL CONTRACT THE <br />ENGINEERING TEAM IMMEDIATELY IF BREAKER IS FOUND TO BE <br />INSUFFICIENT <br />ABBREVIATIONS <br />A <br />AMPERE <br />AC <br />ALTERNATING CURRENT <br />AL <br />ALUMINUM <br />ART <br />ARTICLE <br />AUX <br />AUXILIARY <br />BLDG <br />BUILDING STRUCTURE <br />CONC <br />CONCRETE <br />CU <br />COPPER <br />DC <br />DIRECT CURRENT <br />EGO <br />EQUIPMENT GROUNDING <br />CONDUCTOR <br />(E) <br />EXISTING <br />EMT <br />ELECTRIC METALLIC TUBING <br />EV <br />ELECTRIC VEHICLE <br />EVSE <br />ELECTRIC VEHICLE SUPPLY EQUIPMENT <br />GALV <br />GALVANIZED <br />GND <br />GROUND <br />HDG <br />HOT DIPPED GALVANIZED <br />I <br />CURRENT <br />KVA <br />KILOVOLT AMPERE <br />KW <br />KILOWATT <br />M <br />METER <br />MAX <br />MAXIMUM <br />MIN <br />MINIMUM <br />N <br />NEUTRAL <br />NEC <br />NATIONAL ELECTRIC CODE_ <br />NTS <br />NOT TO SCALE <br />(N) <br />NEW <br />OC <br />ON CENTER <br />PL <br />PROPERTY LINE <br />PVC <br />POLYVINYL CHLORIDE <br />RMC <br />RIGID METALLIC CONDUIT <br />SCH <br />SCHEDULE <br />SS <br />STAINLESS STEEL <br />TYP <br />TYPICAL <br />V <br />VOLT <br />W <br />WATT <br />XFMR <br />TRANSFORMER <br />ELECTRICAL NOTES: <br />1. ALL ELECTRICAL WORK AND RELATED ACTIVITIES PERFORMED ON —SITE <br />SHALL BE DONE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (NEC) <br />STANDARDS BEING ENFORCED BY ALL APPLICABLE JURISDICTIONAL <br />REQUIREMENTS AT THE TIME OF CONSTRUCTION. <br />2. UTILITY EQUIPMENT INSTALLATIONS AND PREP WORK SHALL BE <br />COORDINATED WITH THE APPROPRIATE UTILITY ENGINEER AT TIME OF <br />PRECONSTRUCTION MEETING TO ENSURE ACCURACY OF INSTALLATIONS. <br />3. CONDUIT PATHS ARE REPRESENTATIVE ONLY. EXACT CONDUIT PLACEMENT <br />TO BE DETERMINED ON SITE BASED ON FIELD CONDITIONS. <br />48" REMOVAL <br />(12" ON EACH SIDE OF TRENCH) <br />GENERAL CONTRACTORS TO <br />REPLACE ASPHALT SURFACING <br />TO MATCH EXISTING <br />CAUTIONARY TAPE <br />COMPACTED BACKFILL WITH <br />SATISFACTORY NATIVE OR <br />IMPORTED SOIL TO 95% <br />PROCTOR <br />UNDISTURBED SOIL <br />COMPACTED SAND BED <br />(SEE NOTE 1) <br />COMMUNICATIONS CONDUIT <br />POWER CONDUIT —I <br />12" MIN. <br />NOTES: <br />(TYP.) <br />1. <br />LEAN CONCRETE RED <br />—COLORED TOP, <br />MAY BE USED IN PLACE OF COMPACTED <br />SAND. <br />2. <br />BURY CONDUITS 36" <br />MINIMUM BELOW <br />FINISHED GRADE, <br />ALL PVC SWEEPS TO <br />BE A MINIMUM <br />36" SWEEPS. <br />4, <br />CONDUIT SIZES PER <br />CONDUIT SCHEDULE <br />i Tr.) <br />NOTES: <br />1. EXACT CONDUIT DIAMETERS MAY VARY UPON INSTALLATION. REFERENCE CONDUIT <br />SIZE PER THE CONDUIT SCHEDULE <br />Mf— Ml And nnn Ifli IIT <br />ALANT <br />�W BAND <br />�G ROOF FINISH <br />RETE DECK <br />--- FIRESTOPPING <br />SEALANT (Ul. 1479) <br />POWER TRENCH SCALE 1 BORE SECTION DETAIL SCALE 2 CORE DETAIL SCALE <br />N.T.S. N.T.S. N.T.S. <br />z <br />"A" = DIA. OF CROWN CROWN DIAMETER TO BE EXPOSED CONDUIT AT GRADE TO STUB UP <br />THE DIAMETER OF THE WALL OPENING PLUS 1" - <br />3'-0" <br />FIRE —RATED GYPBD/STUD WALL ASSEMBLY EXISTING SURFACE <br />3" MAX. DIA, MTL. PIPE. PROVIDE NOM. ATTACH CONDUIT TO CONDUIT • <br />1" ANNULAR SPACE AROUND PIPE SUPPORT BLOCK WITH GALVANIZED `' = ° °a e <br />CONDUIT STRAPS <br />OPTIONAL FORMING MATERIAL — RECESSED \ \ \ \ \ <br />`< 1/2" FROM THE SURFACE FOR FS900 <br />MATERIAL (MINERAL WOOL, <br />POLYSTYRENE, .ETC.) <br />— TREMCO THROUGH —PENETRATION FIRE —STOP <br />SYSTEMS, ICBO #3198 <br />K•� Ki.• 5. wee mow`'• .w4+•,9 <br />- ®-•';<'n `i `'.iq'r ;" ;a`•-'`.Y„e 'r' • is:::+;n.r: `t',,�ifiP <br />ADD. MATERIAL ADDED TO FORM 5/8" CROWN �`'':;__':'�y'"snkS4z{" <br />..� <br />AROUND CONDUIT AND LAPPING I" BEYOND =Q'�4 <br />OPENING <br />:+ � <br />FRAMED WALL PENETRATION T� �rr `� <br />aYs� s"�y,Y'.� :;�; may,«,:: ai N��.';` 7•'�. <br />3 1 /4" MIN. CONC. WALL OR CMU. OPENING <br />TO PROVIDE 3/4" MAX. ANNULAR SPACE <br />a • ° . 4 AROUND PIPIE <br />4" MAX. DIAM <br />�I METAL PIPE <br />TREMCO THROUGH —PENETRATION <br />FIRE —STOP SYSTEMS, ICBO #3198 <br />4° a <br />4 <br />MINERAL WOOL (4 PCF) PACKED INTO ANNULAR <br />SPACE AND RECESSED 1 /2" FROM WALL SURFACES <br />CONCRETE WALL PENETRATION <br />CONDUIT FLOOR CLAMP, TYP. <br />TREMCO THROUGH —PENETRATION <br />FIRE —STOP SYSTEMS, ICBO #3198 <br />ONDUIT PER PLAN <br />MAX.) <br />CRETE FLOOR <br />CONCRETE FLOOR PENETRATION <br />NOTES: <br />1. <br />CONTRACTOR <br />TO X-RAY PRIOR <br />TO DRILLING OR CORING TO LOCATE <br />(E) RE —BAR. <br />DO NOT CUT RE —BAR. <br />2. <br />PENETRATIONS <br />THRU WALLS SHALL <br />COMPLY WITH T24, CBC SECTION <br />709.6, <br />2.1. <br />F RATING <br />— PENETRATIONS <br />4" — OR LESS <br />2.2. <br />T RATING <br />— PENETRATIONS <br />LARGER THAN 4" —, PENETRATIONS <br />@ <br />CORRIDOR <br />CLGS. WHICH ARE NOT RATED, BELOW <br />3. <br />PENETRATIONS <br />THRU FLOORS/ <br />CEILINGS SHALL COMPLY WITH T24, CBC <br />SECTION <br />710.3, <br />3.1. <br />F RATING <br />— PENETRATIONS <br />4" — OR LESS <br />3.2. <br />T RATING <br />— PENETRATIONS <br />LARGER THAN 4" —, PENETRATIONS <br />NOT <br />CONTAINED <br />WITHIN A WALL. <br />SUPPORT BLOCK (COOPER B—LINE <br />DURA—BLOCK DB20 OR APPROVED <br />EQUIVALENT) <br />/ r/ N I Fl l I T T C` T M A P <br />CONDUIT SIZE PER PLANS <br />APPROPRIATE <br />BOLTS FOR THE EXTERIOR WALL TYPE <br />UNDISTURBED <br />UIT <br />1. EXACT CONDUIT DIAMETERS MAY VARY UPON INSTALLATION, REFERENCE CONDUIT <br />SIZE PER THE CONDUIT SCHEDULE <br />JUNCTION BOX SHALL BE POLYMER <br />CONCRETE CONSTRUCTION <br />CONCRETE <br />COLLAR <br />CLASS A3 <br />LID SHALL BE <br />TIER 15 RATED <br />NON —TRAFFIC RATED JUNCTION BOX <br />TOP VIEW <br />8 <br />GROUNDING <br />ELECTRODE <br />OPEN BOTTOM <br />�o oa�a ' EE 00� I 12>, <br />o0 00-K0 <br />•88, -78, -8 AGGR. <br />PLACED UNDER ENTIRE BOTTOM OF BOX <br />SECTION VIEW <br />COVER DETAIL <br />NON—SKIDI SURFACE <br />I <br />Ems-------- - ELEC <br />A <br />LIFT RING OR SLOT <br />D LINE <br />COMPACTED SOIL <br />AROUND SIDES OF BOX <br />♦'wl : , • , [oil] • <br />B <br />VOLTAI <br />155 DE HARD STREET <br />SAN FRANCISCO, CA 94103 <br />Kimic^lLyjr*Horn <br />4637 CHABOT DRIVE SUITE 300 <br />PLEASANTON, CA 94588 <br />Main: 925-398-4840' www.kimley-horn.com <br />© 2020 Kimley-Horn and Associates, Inc. <br />4 <br />05/20/2020 <br />CD100s-CITY COMMENTS <br />SAL <br />3 <br />02/06/2020 <br />CD100s <br />GCC <br />2 <br />10/10/2019 <br />CD100s <br />GCC <br />1 <br />08/19/2019 <br />CD90s <br />SDD <br />REV <br />DATE <br />DESCRIPTION <br />BY <br />ISSUE DATE <br />05/21/2020 <br />ISSUED FOR <br />REVIEW <br />' CO <br />�� ®F SPA <br />&0 1= m <br />ttGIST06�'C�s <br />��S�IONAL 'eta <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE DIRECTION <br />OF A LICENSED PROFESSIONAL <br />ENGINEER, TO ALTER THIS DOCUMENT. <br />SAFEW" STORE <br />#503 <br />11031 19TH AVE SE <br />EVERETT, WA 98208 <br />SHEET TITLE <br />SHEET NUMBER <br />