Laserfiche WebLink
I(E) SIDING; RE/RE <br />TO ACCOM WORK <br />(E) PLY, TYP <br />I <br />(E) GYP, TYP <br />(E) WRB; <br />2 LAYERS OF WRB; ' FOLD BACK <br />PROPERLY LAP W/ ( TO ACCOM <br />(E) WRB & FF-1 II I WORK; <br />PROPERLY <br />FF-1; INSTALL II LAP W/ FF-1 <br />INTO RO & M I N <br />9" ONTO GYP I " <br />FACES @INT &cD <br />EXT OF DOOR SHIM AS <br />1 <br />REQ D <br />BR &SLNT-1, TYP <br />DOOR-1 OR PLY-1 <br />(E) DOOR TO <br />BE RE/RE TAPERED <br />SLEEPERS <br />A HEAD B SILL @ CONC <br />(E) WRB, FOLD BACK SHIM AS REQ'D <br />TO ACCOM WORK <br />- - DOOR-1 OR <br />- - - - (E) DOOR TO <br />to BE RE/RE <br />1 <br />I FF-1; INSTALL <br />INTO RO & MIN <br />9" ONTO GYP <br />FACE @ INT & <br />I EXT OF DOOR <br />BR & SLNT-1 @ <br />(E) SIDING RE/RE JAMBS, TYP <br />TO ACCOM WORK 2 LAYERS OF WRB; SET IN <br />CONT BEAD OF SLNT-5 @ <br />JAMB DOOR FRAME <br />C - <br />6 DOOR DETAILS - SECTIONS <br />3" = 1'-011 <br />NOTES <br />MEM-1 W/ INTEGRAL FF-5 DOOR-1 OR (E) DOOR TO NOTE: REF 8D/A5.3 FOR <br />& FF-6, SET IN SLNT-4 BE RE/RE WALKWAY FASCIA. <br />2 W/O HEMMED EDGE 0/ BOTTOM RAIL <br />MEM-1 @ BASE OF <br />WALL, BELOW ALUM MEM-1 W/ <br />- - - THRESHOLD @ DOOR INTEGRAL FF-6 O/ - <br />- - - ONLY & UNDER ALUM v <br />ALUM THRESHOLD, SET O/ SHIM, SET IN <br />CONT GASKET STRIPS, <br />SLNT-4 <br />INSTALL FILLET SLNT-4 @ <br />MEM-1, (E) CONC & JAMBS; <br />I I <br />DO NOT FASTEN <br />THRESHOLD THROUGH PLY-1 O/ TAPERED <br />MEM-1 SLEEPERS; ROUTE <br />EDGE TO ACCOM <br />CONT EPDM ISOLATION MTL #18 <br />STRIP @ CONC, TYP <br />S.S. COUNTERSUNK <br />BR & <br />FASTENERS, PROVIDE TOP MOUNTED GUARDRAIL @WALKWAY <br />SLNT-4 GASKETS BELOW ALUM, TYP A <br />(E) CONC WALKWAY GYPA OR (E) <br />ASSEMBLY TO <br />-TOP MOUNTED <br />GUARDRAIL POST W/ <br />BASE PLATE & ALUM <br />SHIM; REF 4-6/S2.0 FOR <br />STRUCT <br />-CONT SLNT-4 CANT FULL <br />PERIMETER OF ALUM SHIM, TYP <br />SET IN SLNT-4; <br />REF 17/A5.3 FOR <br />SADDLES & <br />TRANSITIONS <br />(E) OR (N) FRAMING; ADD <br />BLOCKING PER STRUCT <br />WHERE REQ'D <br />(E) SIDING O/ 2 <br />LAYERS OF WRB <br />0/ GYPA <br />GYP I SID-1 O/ 3/8" PLY <br />REMAIN INSTALLED FURRING <br />PLY-2 OR (E) <br />NOTE: SIDING NOT PLY , CONT INSECT SCREEN @ <br />SHOWN FOR CLARITY. BASE OF 3/8" PLY FURRING <br />2 LAYERS OF <br />WRB <br />1. ALL (E) ELEVATED LANDING DOORS & FRAMES TO BE RE/RE <br />TO ACCOM WORK. ONE DOOR @ BLDG 5 SHALL BE RE/REP, <br />REF 1 B/A3.2 & ARCH FOR ADD'L INFO. <br />2. REF SHEETS A3.1 & A3.2 FOR TYP DOOR LOCATIONS. <br />3. DOORS & FRAMES @ GROUND FLOOR TO REMAIN <br />INSTALLED. <br />4. ALL DOORS @ MEM-1 SHALL RECEIVE (N) ALUM THESHOLDS; <br />REF 6B/A5.3. <br />NOTE: SADDLE MAY <br />l _ ! 4 SAM-1 @ VARY; COORD W/ ARCH <br />2 LAYERS OF WRB; O/ CORNERS; <br />MTL #23; PROPERLY I LEAVE PAPER <br />LAP O/ MEM-1 I NOTE: REF 16/A5.3 FC <br />I BACKING IN INSTALLATION. <br />REF 17D/A5.3 3 I I PLACE WHEN <br />FOR AXON I INSTALLED O/ <br />MEM-1 <br />PLY-1' <br />O/ NOTE: <br />TAPERED MEM-1, <br />SLEEPERS SIDING & <br />MTL #18 NOT <br />SHOWN FOR <br />I <br />4" 4" <br />�, <br />CLARITY. SADDLE @ PLANARLJ UN 1 IF <br />CLEAT <br />CL/VC <br />(E) OR (N) EXTERIOR CORNER <br />0 CLEAT <br />WD BEAM j A <br />1 2 LAYERS NOTE: REF 16B/A5.4 <br />OF WRB W/ <br />�.� FOR INSTALLATION. <br />SAM-1 @ <br />WALKWAY <br />CORNERS V/F <br />T P-% A � /1 � T � i1 A 1 �� ire � . w • � • w -1- <br />NO SCALE <br />MEM_MTL_WW AX 001 <br />03 2 LAYERS OF WRB; O/ <br />4 SAM-1 @ <br />_ <br />CORNERS; <br />MTL #20; PROPERLY <br />I <br />LEAVE PAPER <br />LAP O/ MEM-1 ' <br />BACKING IN <br />REF 17A/A5.3 0 I <br />I <br />PLACE WHEN <br />FOR AXON I I <br />INSTALLED O/ <br />MEM-1 <br />PLY-1 <br />O/ <br />0 <br />TAPERED <br />NOTE: <br />SLEEPERS <br />' <br />MEM-1, <br />SIDING & <br />�I <br />MTLS #14 & <br />#18 NOT <br />(E) OR (N) <br />SHOWN FOR <br />WD BEAM <br />I <br />CLARITY. <br />i <br />1 2 LAYERS <br />i <br />OF WRB W/ <br />SAM-1 @ <br />WALKWAY <br />CORNERS <br />16 TRANSITION @ <br />SID-1 - AXON <br />NO SCALE <br />04 <br />V/F <br />CONT DRIP HEMMED <br />EDGE CLEAT EDGES, TYP <br />SADDLE @ TOP OF 4 <br />E STRINGER @ WALKWAY <br />NOTE: REF 1 C/A5.4 <br />FOR SECTION. <br />a <br />CD <br />MEM-1; W/ INTEGRAL <br />FF-5, SET IN SLNT-4 <br />t-PLY-1 O/ TAPERED <br />SLEEPERS <br />SLOPE <br />(E) OR (N) FRAMING W/ <br />BLOCKING AS L-BLOCK AS (N) TAPERED 2X <br />REQ'D TO INSTALL REQ'D SLEEPERS RIPPED TO <br />MEM-1 SLOPE AS REQ'D <br />MEM-1 @SID-1 NOTE: REF 8C & <br />D/A5.3 FOR SOFFIT. <br />TYPICAL LANDINGS <br />& ELEVATED WALKWAYS - SECTIONS <br />3" = 1'-011 <br />SID FCP XXX SE 003 <br />NOTE: REF SHEETS <br />A3.1, A3.2 & 16G/A5.4 <br />FOR TYP INSTALLATION. <br />6" <br />4 ' 'I VlFj4„ <br />4" <br />211 <br />DRIP OR STRAIGHT EDGE <br />CLEAT UNDER STRINGER <br />SADDLE @ <br />B BEAM TO WALL TRANSITION <br />NOTE: REF <br />16E/A5.4 FOR TYP <br />HEMMED INSTALLATION. <br />EDGES, TYP <br />411p 4" TYP <br />211 <br />VIF <br />STRAIGHT , <br />4" <br />EDGE CLEAT <br />STRAIGHT 4" VIF 41. <br />EDGE CLEAT <br />TOP OF STRINGER @WALL <br />F <br />`-HEMMED <br />STRAIGHT <br />STRAIGHT EDGE EDGE <br />FLASHING @STAIRS 19 <br />H <br />WALKWAY & LANDING <br />FLASHING COMPONENTS - AXONS <br />MEM_MTL_WW_AX_001 I �A5.31 NO SCALE MEM_MTL_SD_AX_001 <br />NOTE: REF 16C & D/A5.4 FOR <br />SIM INSTALLATION, <br />4" <br />TyP <br />2" TYP <br />,CONT DRIP <br />INTERIOR CORNER 6 EDGE CLEAT <br />a <br />I <br />II <br />II <br />= <br />I� <br />L_ <br />PLY-2 OR (E) PLY <br />GYP-1 OR (E) GYP <br />2 LAYERS OF WRB; LAP <br />W/ (E) WRB <br />(E) SID TO BE RE/RE AS <br />REQ'D TO ACCOM MEM-1 <br />INSTALL OR STRUCT, TYP <br />BLOCKING AS REQ'D <br />TO INSTALL MEM-1 <br />;E� <br />EINTEGRAL FF-5, <br />NT-4 <br />TAPERED SLEEPERS <br />NOTE: REF 6A/A5.2 <br />FOR SID-1 TO <br />SOFFIT <br />TRANSITIONS. <br />()OR (N) FRAMING W/ <br />(N) TAPERED 2X <br />SLEEPERS RIPPED TO <br />SLOPE AS REQ'D <br />BLKG AS REQ'D <br />o r- i vi <br />GYP-1; <br />Pll <br />C WALKWAY @ WALL <br />1/2" END DAM <br />VENT-1; LOCATE V-0" <br />FROM FRONT & BACK <br />EDGES; PROVIDE <br />BLKG AS REQ'D TO <br />SUPPORT SOFFIT <br />NOTE: REF 16A/A5.4 <br />FOR INSTALLATION. <br />CLEAT EDGES, TYP EDGE CLEAT <br />SADDLE @ TOP OF <br />STRINGER @WALKWAY <br />C <br />DRIP EDGE <br />CLEAT <br />NOTE: REF 1A & B/A5.4 <br />FOR SECTION. <br />4" F <br />HEMMED <br />DRIP EDGE <br />DRIP EDGE FLASHING 18 <br />G <br />NOTE: REF 16C & D/A5.4 <br />FOR INSTALLATION. <br />4ff <br />TP <br />2" TYP <br />STRAIGHT <br />EDGE CLEAT 41, <br />INTERIOR <br />CORNER @ STAIRS <br />DRIP EDGE <br />CLEAT <br />NOTES: <br />1. REF SECTION 01 10 00 - DESCRIPTION OF THE WORK & SHEET <br />A0.3 FOR FRAMING REPLACEMENT INFO & LOCATIONS. <br />2. REFER TO SHEETS A3.3 & A3.4 FOR ENLARGED ELEVS OF <br />GUARDRAILS @ WALKWAYS & LANDINGS. <br />3. REFER TO SHEETS A5.3 & A5.4 FOR METAL FLASHING <br />COMPONENTS. <br />4. GUARDRAILS VARY; REFER TO SHEETS A3.1 & A3.2 FOR <br />ENLARGED STAIR PLANS. <br />5. REFER TO SHEETS S1.0 & S2.0 FOR STRUCT REQUIREMENTS <br />@ GUARDRAILS. <br />6. REF 16/A5.4 FOR MEM-1 TRANSITIONS & TERMINATIONS @ <br />STAIR STRINGERS. <br />7. ROUT SHEATHING EDGE TO ACCOM MTLS #18, #19 & <br />ASSOCIATED SADDLES. <br />8. INSTALL LIGHT-1 @ ALL (E) SOFFIT LIGHT LOCATIONS, <br />INCLUDING TOP FLOOR W/ (E) SOFFITS TO REMAIN INSTALLED. <br />MEM-1 W/ INTEGRAL 18 SET IN SLNT-4; <br />FF-6, SET IN SLNT4 REF 17/A5.3 FOR <br />----- -'N SADDLES & <br />- - - - - TRANSITIONS <br />�a <br />5.4 <br />OPP <br />PLY-1 0/ TAPERED <br />SLEEPERS; ROUTE <br />EDGE TO ACCOM _ - - - L (E) SIDING O/ 2 <br />MTL #18 - LAYERS OF WRB <br />O/ GYPA <br />(E) OR (N) <br />WALKWAY I <br />FRAMING ( BOTTO_M OF WALKWAY <br />FASCIA TO BE LEVEL <br />SPA O/ GYP-1; <br />PNT-6 TRIM-3 W/ FILLET <br />SLNT-2; PNT-6 <br />NOTE: VENT-1 NOT SHOWN, <br />COORD W/ ARCH FOR LOCATIONS. <br />NOTE: SOFFIT DETAIL SIM @ BASE OF STAIR <br />STRINGERS; REF 19B/A5.4 FOR FASCIA. <br />D TYPICAL WALKWAY/LANDING INTERIOR EDGE <br />4" 411 NOTE: REF <br />11 /A5.3 FOR <br />INSTALLATION. <br />1/2" END DAM <br />SADDLE @ <br />WALKWAY BEAM TO (E) SIDING <br />AMENTOGROUP <br />710 2nd Avenue, Suite 400 <br />Seattle, WA 98104 <br />amentogroup.com <br />9016 REGISTERED <br />' \ ARCHITECT <br />& <br />LISA CLARK MOE <br />STATE OF WASHINGTON <br />The documents created by the <br />Architect and its Consultants <br />for this project are instruments <br />of the Architect's service. The <br />Architect retains all common <br />law, statutory and other <br />reserved rights, including the <br />copyright. The Architect's <br />documents shall not be used <br />by anyone on any other <br />project, except with the <br />Architect's written permission. <br />GREENS OF <br />MERRILL CREEK <br />APARTMENTS <br />D <br />1707 MERRILL CREEK PKWY <br />EVERETT, WA 98203 <br />STAIR <br />REMEDIATION <br />SCOPE OF <br />REPAIR <br />WATERPROOFING & <br />FLASHING DETAILS <br />PERMIT SET <br />PROJECT #: <br />070042 <br />DRAWN BY: <br />AJL, DGS, HLS <br />CHECKED BY: <br />MFV, MNM <br />REVISIONS: <br />10-16-2020 PERMIT SET <br />NOTES: <br />1. REFER TO SHEETS A3.1 & A3.2 FOR ENLARGED <br />WALKWAY/LANDING PLANS. <br />2. REF METAL SCHEDULE ON SHEET A0.1 FOR DIMENSIONS & <br />ADD'L FLASHING PARAMETERS. <br />3. PREP DRIP EDGES TO RECEIVE ADJ MTL FLASHING @ FLAT <br />DATE: <br />LAPPED SEAMS, WHERE THEY OCCUR; REF 12/A5.1. 10-16-2020 <br />4. USE DRIP EDGE CLEATS TO SECURE ADJ MTL FLASHINGS. SHEET TITLE: <br />5. REF 16/A5.4 FOR ASSEMBLY CONDITIONS @ ELEVATED TYP ELEVATED <br />WALKWAY/LANDING EDGES. WALKWAY/ <br />6. INSTALL FLASHINGS IN SEQUENCE NOTED ON ASSEMBLY LANDING DETAILS <br />DETAILS. <br />7. SET ALL SADDLES & FLASHINGS IN SLNT-4 & SEAL MTL LAPPED BUILDING TYPE: <br />SEAMS @ MEM-1 W/ SLNT-4. <br />SHEET M <br />8. FORM MTL FLASHINGS TIGHT TO STRINGERS & SUBSTRATES, <br />TYP. <br />A503 <br />9. HEM ALL EDGES WHERE EXPOSED. <br />N/A <br />