FLASHING
<br />SOLDERED
<br />VERT
<br />HORN
<br />VPRT
<br />SIDE OR
<br />MOCKUP
<br />TYPE
<br />a
<br />DESCRIPTION
<br />DETAIL REFERENCES
<br />ONE-PIECE
<br />FINISH
<br />FLANGE
<br />FLANGE
<br />DRIP
<br />RETURN
<br />REQUIREMENTS
<br />COMMENTS
<br />FLANGE
<br />FLANGES
<br />1
<br />HEAD FLASHING @ MISC PENETRATIONS
<br />16A/A5.2; 6D/A5.5
<br />NO
<br />MTL-1
<br />4"
<br />VIF
<br />3/4"
<br />-
<br />REO'D
<br />W1 HEMMED DRIP EDGE & 1/2" END DAMS, SET IN SLNT-2
<br />HEAD
<br />OR
<br />FLASHINGS
<br />MTL-3
<br />2
<br />"L" BASE METAL FLASHING @
<br />9A,12/A5.1; 17/A5.2;
<br />NO
<br />MTL-4
<br />6"
<br />1 1/2" 1
<br />-
<br />REO'D
<br />W/ HEMMED EDGE; PROVIDE SADDLES #6, 7, 8, 9, 10 11 & 12; SET IN
<br />HARDSCAPE & BRICK
<br />6B/A5.3
<br />OR
<br />VIF
<br />SLNT-3
<br />MTL-5
<br />3
<br />STRAIGHT BASE METAL FLASHING
<br />9B/A5.1
<br />NO
<br />MTL-4
<br />5"
<br />-
<br />-
<br />-
<br />W/ STRAIGHT HEM; SET IN SLNT-3
<br />4
<br />"L" BASE METAL FLASHING @ GRADE
<br />9C/A5.1
<br />NO
<br />MTL-4
<br />4"
<br />VIF /
<br />_
<br />-
<br />-
<br />11V/O HEMMED EDGE; PROVIDE IN CONJUNCTION W/ MTL WHERE
<br />VARIES
<br />GRADE IS MORE THAN 6" FROM BASE OF SIDING; SHAPE PER DETAIL
<br />TO ACCOM MTL #5
<br />5
<br />"Z BASE METAL FLASHING @ GRADE
<br />D/A5.1
<br />NO
<br />MTL-4
<br />4"
<br />VIF
<br />1"
<br />-
<br />-
<br />SHAPE PER DETAIL, W/ HEMMED EDGE, SET IN SLNT-3
<br />6
<br />#2 INT CORNER SADDLE
<br />8A,17/A5.2
<br />YES
<br />MTL-2
<br />6"
<br />1 1/2" /
<br />0
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED
<br />VIF
<br />EDGES
<br />7
<br />#2 EXT CORNER SADDLE
<br />8B,17/A5.2
<br />YES
<br />MTL-2
<br />6"
<br />1 1/2" /
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL TO ACCOM MTL 2
<br />SIDING,
<br />VIF
<br />BASE &
<br />8
<br />#2 SADDLE @ HARDSCAPE TRANSITIONS
<br />8C/A5.2
<br />YES
<br />MTL-2
<br />6"
<br />VIF /
<br />_
<br />4"
<br />-
<br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED
<br />TRANSITION
<br />VARIES
<br />EDGES
<br />FLASHINGS
<br />9
<br />#2 SADDLE @ GRADE TO HARDSCAPE
<br />8D/A5.2
<br />YES
<br />MTL-2
<br />6"
<br />VIF /
<br />VIF
<br />4"
<br />-
<br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED
<br />TRANSITION
<br />VARIES
<br />EDGES
<br />10
<br />BRICK CAP SADDLE
<br />8E,10/A5.2
<br />YES
<br />MTL-2
<br />6"
<br />VIF
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL TO ACCOM (E) BRICK & FETAL; W/ 1/2" END DAM
<br />& HEMMED EXPOSED EDGES
<br />11
<br />NOT USED
<br />_
<br />-
<br />_
<br />-
<br />-
<br />-
<br />-
<br />-
<br />12
<br />RIOT USED
<br />-
<br />-
<br />-
<br />_
<br />-
<br />13
<br />"J" METAL @ SID-1 TO CONC
<br />6A/A5.1
<br />NO
<br />MTL-4
<br />-
<br />6"
<br />-
<br />-
<br />-
<br />SHAPE PER DETAIL W/ HEMMED EDGE
<br />14
<br />SID-1 THROUGH WALL FLASHING
<br />13A,17A,B,C,D/A5.1
<br />NO
<br />MTL-1
<br />6"
<br />VIF
<br />2"
<br />-
<br />REO'D
<br />SHAPE PER DETAIL W/ HEMMED DRIP EDGE
<br />15
<br />#14 EXT CORNER SADDLE
<br />13B,17A,C/A5.1
<br />YES
<br />MTL-2
<br />6"
<br />VIF
<br />2"
<br />-
<br />REO'D
<br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT
<br />16
<br />#14 END CAP SADDLE
<br />13C,17B/A5.1
<br />YES
<br />MTL-2
<br />6"
<br />VIF
<br />2"
<br />-
<br />REO'D
<br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT
<br />17
<br />NOT USED
<br />-
<br />-
<br />-
<br />-
<br />-
<br />-
<br />-
<br />-
<br />18
<br />WALKWAY& LANDING DRIP EDGE
<br />8A,D,17G1A5.3-,
<br />NO
<br />MTL -1
<br />-
<br />4"
<br />2"
<br />-
<br />RECOMMENDED
<br />W/ HEMMED DRIP EDGE; PROVIDE SADDLES @ CORNERS,
<br />FLASHING
<br />1A,1 B,16A,B,C,D,E/A5.4
<br />TRANSITIONS & TERMINATIONS
<br />19
<br />HEMMED EDGE FLASHING @ STAIR
<br />-
<br />RECOMMENDED
<br />W/ STRAIGHT HEM; PROVIDE SADDLES @ CORNERS, TRANSITIONS &
<br />17H/A5.3;
<br />NO
<br />MTL-1
<br />-
<br />4"
<br />2"
<br />TREADS
<br />1C,16,19B,C/A5.4
<br />TERMINATIONS
<br />20
<br />#14 TO #18 SADDLE @ WALL
<br />16,17A/A5.3
<br />YES
<br />MTL-2
<br />6"
<br />4"
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT
<br />21
<br />#18 OR #19 SADDLE @ BEAM TO WALL
<br />17B/A5.3; 16G1A5.4
<br />YES
<br />MTL-2
<br />6"
<br />4" / VIF
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT @ MTL #18 OR STRAIGHT
<br />EDGE CLEAT @ MTL #191 SIZE HORN FLANGE TO EXTEND BELOW &
<br />4" PAST STRINGER (WHERE OCCURS) TO LAP W/ADJ EDGE
<br />WALKWAY &
<br />FLASHING
<br />LANDING
<br />22
<br />#18 & #19 SADDLE @ TOP OF STRINGER
<br />17C/A5.3; 16A/A5.4;
<br />YES
<br />MTL-2
<br />-
<br />4" / VIE
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; PROVIDE END DAM; W/ DRIP EDGE CLEAT &
<br />FLASHINGS
<br />19A/A5.5
<br />STRAIGHTEDGE CLEAT; HEMMED EXPOSED EDGES
<br />23
<br />#18 SADDLE @ BEAM TO PLANAR WALL
<br />11,17D/A5.3
<br />YES
<br />MTL-2
<br />6"
<br />4"
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W1 DRIP EDGE CLEAT
<br />24
<br />#18 & #19 SADDLE @ TOP OF STRINGER
<br />17E/A5.3; 16B/A5.4
<br />YES
<br />MTL-2
<br />-
<br />4" / VIF
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT;
<br />HEMMED EXPOSED EDGES
<br />25
<br />#18 & #19 SADDLE @ TOP OF STRINGER
<br />17F/A5.3; 16E/A5.4;
<br />YES
<br />MTL-2
<br />-
<br />4" / VIF
<br />2
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT;
<br />19B/A5.5
<br />HEMMED EXPOSED EDGES
<br />26
<br />#18 INT CORNER SADDLE
<br />17VA5.3
<br />YES
<br />MTL-2
<br />-
<br />4"
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEATS
<br />27
<br />#18 & #19 INT CORNER SADDLE
<br />17J/A5.3;
<br />YES
<br />MTL-2
<br />-
<br />4"
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT;
<br />16C,D,19A/A5.4
<br />SI7E HORIZ FLANGE TO EXTEND BELOW & 4" PAST STRINGER
<br />(WHERE OCCURS) TO LAP W/ADJ EDGE FLASHING
<br />-
<br />28
<br />STRINGER CAP FLASHING
<br />4/A5.4;19B/A5.5
<br />NO
<br />MTL-1
<br />6"
<br />VIF
<br />VIF
<br />-
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ HEMMED EDGE & END DAM @ BOTTOM OF
<br />MISC
<br />STRINGER; PROPERLY LAP W/ MTL #25 @ TOP OF STRINGER;
<br />FLASHINGS
<br />PROVIDE BLOCKING @ HANDRAIL ATTACHMENT LOCATIONS
<br />1METAL SCHEDULE_
<br />A0,1
<br />1. REFERTO METAL._ A0.1 &METAL FLASHING
<br />SCHEDULE NOTES ON i
<br />2. INSTALL METAL FLASHINGS IN ACCORDANCE W/ SMACNJ
<br />FLASHING6. FIELD VERIFY ALL SIZES DIMENSIONS; ALL FLASHINGS SHALL
<br />TIGHTFIT & TRUE
<br />7. ALL METAL FLASHING IS TO HAVE MINIMUM 4" FLAT SEAM OVERLAPS, UNO.
<br />FULLY SEAL PER - - SEAM OVERLAPS
<br />BACKER PLATES @ ALL LOCATIONS.
<br />8. SET ALL METAL IN SEALANT WHERE TYPICAL & NECESSARY
<br />CREATE RASSEMBLIES.:. FLASHINGS SEALANT
<br />SHOWN ':
<br />2. DESCRIPTIONS OR TITLES OF METAL FLASHINGA . !
<br />EXACTLY MATCHADESCRIPTION
<br />FLASHING>t€ R IS INDICATOR OF SCHEDULED FLASHING @ EACH
<br />DETAIL3. REFERENCE
<br />R, - FORREFERENCE
<br />COMPLETE ASSOCIATED WATERPROOFING
<br />DETAILS.
<br />FLASHING4. DIMENSIONS ARE AS NOTEDSCHEDULE, LINO IN
<br />CLARIFICATION.DETAILS. IF DISCREPANCIES ARISE, CONTACT ARCH FOR DIRECTION &
<br />- --J0,_ -
<br />9. SLOPE HORIZONTAL FLANGES AS REQUIRED TO SHED WATER PER DETAILS. 6. SOLDER METAL FLASHING CORNERS & JOINTS AS NOTED IN DETAILS &
<br />SPECIFICATIONS. INSTALL FULLY SOLDERED ONE-PIECE INTERIOR &
<br />10. ISOLATE ALL METAL FLASHINGS FROM EXTERIOR SHEATHING W1 MINIMUM EXTERIOR CORNERS @ ALL FLASHING TRANSITIONS, UNO.
<br />ONE LAYER OF TARGET WRB. WRB SHALLNOT
<br />RESIDE R
<br />ABOVE METAL FLASHINGS. 7. ALL METAL FLASHING IS 24 GAUGE, UNO.
<br />12. FINISHED METAL FLASHINGS SHB AESTHETICALLYPLEASING, ALIGN,
<br />FLASHINGFORM TIGHT SEAMS & MEET REQUIREMENTS IN SECTION 07 60 00 -
<br />�"2� METAL NOTES
<br />AOa �
<br />8. ALL VERTICAL DRIP FLANGES ARE TO BE HEMMED, UNO IN THE
<br />COMMENTS SECTION
<br />I SCHEDULE.
<br />PROVIDE9. A DRIP _SADDLES NOTED IN THE
<br />COMMENTS SECTION OF THE SCHEDULE. A DRIP EDGE CLEAT IS A
<br />DRIP _W/O AHEM.
<br />110. ALL
<br />HEMMED RimEDGES SHALLBECLOSED!AROUND
<br />VERTICAL11. FLANGE DIMENSIONS NOTED ON SCHEDULE
<br />FLANGEVERTICAL RI OR - DFLANGE;
<br />DRIP OR R ADDITION
<br />DIMENSION.
<br />9 ! ' X
<br />13. REF 12/A5.1 FOR STRAIGHTJ4 . LAP JOINT W1 BACKER PLATE
<br />EXPANSION ! .METAL."_ CONCEPT
<br />ALL OTHER METAL FLAT SEAM i. JOINTS. PROVIDE BACKER PLATE
<br />@ ALL STRAIGHT SEAM LAP JOINTS @ ALL METAL.
<br />PROVIDE
<br />14. CLEATS SHALL BE 24 GAUGE.
<br />ALONG
<br />MOCK-UPS15. MOCK-UPS: PROVIDE MOCK-UPS AS REQUIRED BY SCHEDULE. SOME
<br />BE PROVIDED @ THE CONTRACTOR'SDISCRETION. FLASHINGS SHALL
<br />BE REVIEWED
<br />r_ E T FOR DESIGN INTENT &
<br />! I kh !
<br />INTERFACES, TRANSITIONS OR LOCATIONS,
<br />CONTRACTOR CAN ELECT TO COMBINE (SOLDER) METAL FLASHINGS
<br />TO BEONE-PIECE IN LIEU
<br />OF MULTIPLE PIECE FLASHINGS. A
<br />FLASHING IS SHOWN AS ONE-PIECE & THE CONTRACTOR PREFERS TO
<br />MAKE THE FLASHINGMULTIPLE PIECES,!e 1: ARCH.
<br />�9016 REGISTERED
<br />AP.CHITECT
<br />LISA CLARK MOE
<br />STATE OF WASHINGTON
<br />The documents created by the
<br />Architect and its Consultants
<br />for this project are instruments
<br />of the Architect's service. The
<br />Architect retains all common
<br />law, statutory and other
<br />reserved rights, including the
<br />copyright. The Architect's
<br />documents shall not be used
<br />by anyone on any ether
<br />project, except with the
<br />Architect's written permission.
<br />DRAWN BY:
<br />HLS
<br />7 9
<br />CHECKED BY:
<br />REVISIONS:
<br />10- 16-2020 PERMIT SET
<br />BLDG DEPT:
<br />DATE:
<br />10-16-2020
<br />SHEET TITLE:
<br />BUILDING -1 PE:
<br />a
<br />
|