Laserfiche WebLink
FLASHING <br />SOLDERED <br />VERT <br />HORIZ <br />VERT <br />SIDE OR <br />MOCKUP <br />TYPE <br />DESCRIPTION <br />DETAIL REFERENCES <br />ONE-PIECE <br />FINISH <br />FLANGE <br />FLANGE <br />DRIP <br />RETURN <br />REQUIREMENTS <br />COMMENTS <br />FLANGE <br />FLANGES <br />1 <br />HEAD FLASHING @ MISC PENETRATIONS <br />16A/A5.2; 6D/A5.5 <br />NO <br />MTL-1 <br />4" <br />VIF <br />3/4f1 <br />REQ'D <br />W/ HEMMED DRIP EDGE & 1/2" END DAMS, SET IN SLNT-2 <br />HEAD <br />OR <br />FLASHINGS <br />MTL-3 <br />2 <br />I4L'1 BASE METAL FLASHING @ <br />9A,12/A5,1; 17/A5,2; <br />NO <br />MTL 4 <br />611 <br />1 1/2" / <br />REQ'D <br />W/ HEMMED EDGE; PROVIDE SADDLES #6, 7, 8, 9, 10, 11 & 121 SET IN <br />HARDSCAPE & BRICK <br />6B/A5.3 <br />OR <br />VIF <br />SLNT-3 <br />MTL-5 <br />3 <br />STRAIGHT BASE METAL FLASHING <br />9B/A5.1 <br />NO <br />MTL-4 <br />511 <br />a <br />a <br />W/ STRAIGHT HEM; SET IN SLNT-3 <br />4 <br />"' " BASE METAL FLASHING @ GRADE <br />9C/A5.1 <br />NO <br />MTL-4 <br />4" <br />VIF / <br />e <br />e <br />a <br />W/O HEMMED EDGE; PROVIDE IN CONJUNCTION W/ MTL WHERE <br />VARIES <br />GRADE IS MORE THAN 6" FROM BASE OF SIDING; SHAPE PER DETAIL <br />TO ACCOM MTL #5 <br />5 <br />7' BASE METAL FLASHING @ GRADE <br />9D/A5.1 <br />NO <br />MTL-4 <br />4" <br />VIF <br />1" <br />_ <br />SHAPE PER DETAIL; W/ HEMMED EDGE; SET IN SLNT-3 <br />6 <br />#2 INT CORNER SADDLE <br />8A,17/A5.2 <br />YES <br />MTL-2 <br />611 <br />1 1/2" / <br />m <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED <br />VIF <br />EDGES <br />7 <br />#2 EXT CORNER SADDLE <br />8B,17/A5.2 <br />YES <br />MTL-2 <br />6" <br />1 1/2" / <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL TO ACCOM MTL # 2 <br />SIDING, <br />VIF <br />BASE <br />8 <br />2 SADDLE @ HARDSCAPE TRANSITIONS <br />8C/A5.2 <br />YES <br />MTL-2 <br />6" <br />VIF / <br />e <br />411 <br />e <br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED <br />TRANSITION <br />VARIES <br />EDGES <br />FLASHINGS <br />9 <br />#2 SADDLE @ GRADE TO HARDSCAPE <br />8D/A5.2 <br />YES <br />MTL-2 <br />611 <br />VIF / <br />VIF <br />41' <br />e <br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED <br />TRANSITION <br />VARIES <br />EDGES <br />10 <br />BRICK CAP SADDLE <br />8E,10/A5.2 <br />YES <br />MTL-2 <br />611 <br />VIF <br />211 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL TO ACCOM (E) BRICK & METAL; W/ 1/2" END DAM <br />HEMMED EXPOSED EDGES <br />11 <br />NOT USED <br />_ <br />- <br />m <br />a <br />12 <br />NOT USE® <br />- <br />_ <br />o <br />= <br />13 <br />"J" METAL @ SID-1 TO CONC <br />6A/A5.1 <br />NO <br />MTL-4 <br />611 <br />- <br />- <br />SHAPE PER DETAIL W/ HEMMED EDGE <br />14 <br />SID-1 THROUGH WALL FLASHING <br />13A,17A,B,C,D/A5.1 <br />NO <br />MTL-1 <br />611 <br />VIF <br />211 <br />- <br />REQ'D <br />SHAPE PER DETAIL W/ HEMMED DRIP EDGE <br />15 <br />#14 EXT CORNER SADDLE <br />13B,17A,C/A5.1 <br />YES <br />MTL-2 <br />611 <br />VIF <br />211 <br />REQ'D <br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT <br />16 <br />#14 END CAP SADDLE <br />13C,17B/A5.1 <br />YES <br />MTL-2 <br />6" <br />VIF <br />211 <br />REQ'D <br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT <br />17 <br />NOT USE® <br />= <br />m <br />a <br />- <br />- <br />- <br />m <br />= <br />18 <br />WALKWAY& LANDING DRIP EDGE <br />8A, D, 1 7G/A5.31 <br />NO <br />MTL-1 <br />411 <br />211 <br />o <br />RECOMMENDED <br />WI HEMMED DRIP EDGE, PROVIDE SADDLES @ CORNERS, <br />FLASHING <br />1A,1 B,16A,B,C,D,E/A5.4 <br />TRANSITIONS & TERMINATIONS <br />19 <br />HEMMED EDGE FLASHING @ STAIR <br />_ <br />RECOMMENDED <br />W/ STRAIGHT HEM; PROVIDE SADDLES @ CORNERS, TRANSITIONS <br />17H/A5.3; <br />NO <br />MTL-1 <br />- <br />411 <br />211 <br />TREADS <br />1 C,16,19B,C/A5.4 <br />TERMINATIONS <br />20 <br />#14 TO #18 SADDLE @ WALL <br />16,17A/A5.3 <br />YES <br />MTL-2 <br />611 <br />411 <br />211 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL, W/ DRIP EDGE CLEAT <br />21 <br />#18 OR #19 SADDLE @ BEAM TO WALL <br />17B/A5.3; 16G/A5.4 <br />YES <br />MTL-2 <br />611 <br />4" / VIF <br />211 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL, W/ DRIP EDGE CLEAT @ MTL #18 OR STRAIGHT <br />EDGE CLEAT @ MTL #19)- SIZE HORN FLANGE TO EXTEND BELOW & <br />4" FAST STRINGER (WHERE OCCURS) TO LAP W/ADJ EDGE <br />WALKWAY& <br />FLASHING <br />LANDING <br />22 <br />#18 & #19 SADDLE @ TOP OF STRINGER <br />17C/A5.3; 16A/A5.4; <br />YES <br />MTL-2 <br />- <br />4" / VIF <br />211 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL; PROVIDE END DAM; W/ DRIP EDGE CLEAT <br />FLASHINGS <br />19A/A5.5 <br />STRAIGHTEDGE CLEAT, HEMMED EXPOSED EDGES <br />23 <br />#18 SADDLE @ BEAM TO PLANARWALL <br />11,17D/A5.3 <br />YES <br />MTL-2 <br />611 <br />411 <br />2" <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL, W/ DRIP EDGE CLEAT <br />24 <br />#18 & #19 SADDLE @ TOP OF STRINGER <br />17E/A5.3; 16B/A5.4 <br />YES <br />MTL-2 <br />4" / VIF <br />211 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT; <br />HEMMED EXPOSED EDGES <br />25 <br />#18 & #19 SADDLE @ TOP OF STRINGER <br />17F/A5.3; 16E/A5.4; <br />YES <br />MTL-2 <br />- <br />4" / VIF <br />2 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT; <br />19B/A5.5 <br />HEMMED EXPOSED EDGES <br />26 <br />#18 INT CORNER SADDLE <br />171/A5.3 <br />YES <br />MTL-2 <br />411 <br />211 <br />411 <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEATS <br />27 <br />#18 & #19 INT CORNER SADDLE <br />17J/A5.3; <br />YES <br />MTL-2 <br />- <br />411 <br />211 <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT; <br />16C,D,19A/A5.4 <br />SIZE HORIZ FLANGE TO EXTEND BELOW & 4" PAST STRINGER <br />(WHERE OCCURS) TO LAP W/ADJ EDGE FLASHING <br />28 <br />STRINGER CAP FLASHING <br />4/A5.4;19B/A5.5 <br />NO <br />MTL--1 <br />611 <br />VIF <br />VIF <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ HEMMED EDGE & END DAM @ BOTTOM OF <br />MISC <br />STRINGER; PROPERLY LAP W/ MTL #25 @ TOP OF STRINGER; <br />FLASHINGS <br />PROVIDE BLOCKING @ HANDRAIL ATTACHMENT LOCATIONS <br />1METAL SCHEDULE <br />A0.1 <br />METAL NOTES; <br />METAL FLASHING SCHEDULE NOTES; <br />1. <br />REFER TO METAL FLASHING SCHEDULE ON 1/A0.1 &MIETAL FLASHING <br />1. <br />REFER TO DETAILS & SECTION 07 60 00 - FLASHING & SHEET METAL <br />SCHEDULE NOTES ON 3/A0.1. <br />FOR ADDITIONAL NOTES & DESCRIPTIONS OF FLASHINGS & METAL. <br />CONTRACTOR SHALL THOROUGHLY REVIEW DRAWINGS <br />2. <br />INSTALL METAL FLASHINGS IN ACCORDANCE V\// SMACNA <br />SPECIFICATIONS FOR ADDITIONAL METAL FLASHING INFORMATION <br />RECOMMENDATIONS. <br />NOT CONTAINED IN THE METAL FLASHING SCHEDULE. <br />3. <br />INSTALL METAL FLASHINGS IN SEQUENCE DENOTED ON DRAWINGS. <br />2. <br />DESCRIPTIONS OR TITLES OF METAL FLASHING IN SCHEDULE MAY NOT <br />EXACTLY MATCH FLASHING DESCRIPTION IN DETAILS. METAL <br />4. <br />USE FULL LENGTHS OR LONGEST PIECES OF METAL POSSIBLE. <br />FLASHING NUMBER IS INDICATOR OF SCHEDULED FLASHING @ EACH <br />LOCATION. <br />5. <br />METAL FLASHING FINISHES ARE AS NOTED ON METAL SCHEDULE. <br />3. <br />DETAIL REFERENCE COLUMN IN SCHEDULE IS FOR REFERENCE ONLY <br />6. <br />FIELD VERIFY ALL FLASHING SIZES & DIMENSIONS; ALL FLASHINGS SHALL <br />& IS NOT A COMPLETE LIST OF ALL ASSOCIATED WATERPROOFING <br />FIT TIGHT & TRUE TO SUBSTRATE, UNO. <br />DETAILS. <br />7. <br />ALL METAL FLASHING IS TO HAVE MINIMUM 4" FLAT SEAM OVERLAPS, UNO. <br />4. <br />FLASHING DIMENSIONS ARE AS NOTED ON SCHEDULE, UNO IN <br />FULLY SEAL PER SPECIFICATIONS. PROVIDE 4" FLAT SEAM OVERLAPS @ <br />DETAILS. IF DISCREPANCIES ARISE, CONTACT ARCH FOR DIRECTION <br />BACKER PLATES @ ALL LOCATIONS. <br />CLARIFICATION. <br />8. <br />SET ALL METAL IN SEALANT WHERE TYPICAL & NECESSARY IN ORDER TO <br />5. <br />IF METAL FLASHINGS REQUIRE END DAMS, END CAPS & SOLDERED <br />CREATE WATERTIGHT ASSEMBLIES. SET FLASHINGS IN SEALANT WHERE <br />FLASHINGS, EXPOSED FLASHINGS MUST BE FINISHED TO MATCH <br />SHOWN ON DETAILS. <br />ADJACENT METAL FLASHINGS, OR AS OTHERWISE DIRECTED BY ARCH. <br />9. <br />SLOPE HORIZONTAL FLANGES AS REQUIRED TO SHED WATER PER DETAILS. <br />6. <br />SOLDER METAL FLASHING CORNERS & JOINTS AS NOTED IN DETAILS <br />SPECIFICATIONS. INSTALL FULLY SOLDERED ONE-PIECE INTERIOR <br />10. <br />ISOLATE ALL METAL FLASHINGS FROM EXTERIOR SHEATHING W/ MINIMUM <br />EXTERIOR CORNERS @ ALL FLASHING TRANSITIONS, LINO. <br />ONE LAYER OF TARGET WB. WRB SHALL NOT RESIDE MORE THAN 4" <br />ABOVE METAL FLASHINGS. <br />7. <br />ALL METAL FLASHING IS 24 GAUGE, UNO. <br />11. <br />FILL OR GRIND CONCRETE @ METAL FLASHINGS SET IN SEALANT @ <br />8. <br />ALL VERTICAL DRIP FLANGES ARE TO BE HEMMED, LINO IN THE <br />CONCRETE, AS NEEDED TO CREATE COMPLETE SEAL @ INTERFACE. <br />COMMENTS SECTION OF THE SCHEDULE. <br />12. <br />FINISHED METAL FLASHINGS SHALL BE AESTHETICALLY PLEASING, ALIGN, <br />9. <br />PROVIDE A DRIP EDGE CLEAT @ ALL SADDLES AS NOTED IN THE <br />FORM TIGHT SEAMS & MEET REQUIREMENTS IN SECTION 07 60 00 - <br />COMMENTS SECTION OF THE SCHEDULE. A DRIP EDGE CLEAT IS A <br />FLASHING & SHEET METAL. <br />DRIP EDGE W/O A HEM. <br />r2_-� <br />A0.1 <br />t' 1 j Afgm 3 4 - <br />9016 REGISTERED <br />ARCHITECT <br />1 <br />LISA CLARK MOE <br />STATE OF WASHINGTON <br />Architect and its Consultants <br />for this project are instruments <br />commonof the Architect's service. The <br />Architect retains all <br />law, statutory and other <br />reserved rights, including he <br />documentscopyright. The Architect's <br />writtenby anyone on any other <br />project, except with the <br />: <br />rifffillm- <br />REVISIONS: <br />10=16=2020 PERMIT SET <br />BLDG DEPT: <br />DATE: <br />SHEET TITLE: <br />BUILDING TYPE: <br />