Laserfiche WebLink
) <br />/ 1 i , i , <br />4P, 200A, 600V r � . J <br />l <br />RECEPT. INTERLOCKING <br />TO 767 <br />PLUG AND SWITCH ! ! 46 SEC <br />4V51-4VD2.5/3abc !' I <br />PLATFORM <br />i <br />4V51-4VD2.5/5abc CORD REEL � <br />4V51-4VD2.5 8abc SF-36B ;!;F` JI'T„N'"`"`Ol EE <br />/ MATCHi LINE FOR CONTINUATION SEE SDI �9 1 E1 1 = r _ a <br />i 3 4H I , I, <br />m r <br />-----------0AITO x Sx <br />40 <br />F 3� � <br />---rLp <br />! li I - I � r; 1 °r' I I I I i� �-✓ ,t, i I r I � I I __ �� I _ I I. , <br />i SF 6A _ r. <br />d �. i XP �LTS <br />® <br />3abc ! 13 4 P I I <br />I I <br />I SF-32 I II TYP <br />400A --- e-' ! -' I <br />SHUNT -TRIP ! I EXP ! ( 20MP <br />5abc EX SUB <br />#2®1/A5 ! 3 3/4"C-6#1i2, 8#14, #12 GND 6OAi 1" RGS <br />-=-EXP <br />8abc j- r _ rNa ! 3#8, 4#14, #12 GND <br />X .c-n r; r i <br />6abc ;si N Lc)Y4 I ! N - - I <br />! II I ----- I � � ��� �; � I j I � �� �}�}� I I i r <br />I N i c � i <br />1" RGS, 6#10, ( SF-19B <br />0 <br />8#14, #12 GND <br />! S -2Q 1 /2 HP 30Ai ! <br />1 SFT-25 EXP EXP, SF-1A <br />--- _- <br />1,E1 16 E547 15 <br />XP <br />1 <br />!;-.d.�, $ f_«' -�' I ,"'i Yy ?- d�kr l 1 H L 1-..�� -I 6 A . I M <br />n y�,� ... ,dr. --- <br />- - --------- -- - -- _ _ _.. - ff---- --- - - - --- - - --- --- -- .sL. t_ CV-[^. -•' i i I' N r r., I E P# as <br />1-1 /4 RGS, 12# 12, � .,� -T- <br />16 14 12 GND (I _ - - OA --- ! 3/4" RGS <br /># # 6#12, 8#114, #12 GN6 <br />ON GANTRYI <br />SF ;37P 3/4 #12 4#14 #1 2 G,ND i ! <br />>, 3/4" RGS <br />1 RGS, 3#8, I F__� - i SF- 37 3/4 RGS ! <br />4#14, #10 GND j ' 1 I �; I 1 21HP ! 'I 3#8, 4#1 , #12 GND ! 3#10, 4#14, #1ND <br />f / <br />! XP EXP I XURI X x X, <br />_ -- <br />Ili i l i ,_rll JOA <br />! <br />l I t i <br />i <br />UP TO MEZZ CORD REEL ,, <br />FAN CONTROLLER I� �� <br />- I - � - UP TO ELECTRICAL � �� -- I � ll� <br />MEZZ UP TO i <br />I II I i <br />i I I <br />: <br />.I <br />LZANIN _-ME: <br />� <br />_ <br />---� --I i � '- -- -- I -- - - - -- ------------ -� --- -- - <br />-r 30 - TO MEZZ UP TO ELEC. 10-- MCC-6 f B1,B2 VIA VFDSY`. ! I -- - - - --- -- - --- UP TO ELECTRICAL MEZZ- <br />F C NT 0 LE 1-1 /2 !C, (2)#8 VFD' CABLES, <br />100A 100A 1 $ 4#14 i j ! MCC-5/C5 VIA VFD 8 <br />: I <br />! HA (TYP) EXP EXP <br />1 C, 3#6 4#14 #6G <br />9 <br />t > �'.' ' £ $ F2e, I I i � � � � i a 3 � 5 ��� <br />_��$: �� 116=..�3,�, !EXP E1' B 100A 100A �3,'�� .x_, <br />7 1 EXP EXPI MCC-5/C4 VIA VFD 7' I <br />(Ii �� ! ,- 11/2"C3#6; 4#14 <br />g 3V51-3VD2-D/12,14 - , , #6G! <br />P-9 P-10 ` j j ! �3/4"C, �#10, #10G 11 <br />MCC-5 C5 ® MCC'-5 C6 i ( ! „ <br />t ;I / / ; HA ! ! 3/4 C, 3#6, #8G TYPE XHHW ! 11 <br />I! 30HP 30HP; <br />I <br />r " I I � I , <br />I I <br />SEAS ! - ---- �� P7j P-6 5 <br />I l <br />------ -- ------ -- -- I _ --- - -- _ - - - ---- - -- -- -- - --- 25H P -- -I 25 H P'- ---- <br />6a be - YJ --- ----- - --- ----- - -- ---- --- ---- - - - --- -- ---- - - - -- -- - -- -- - -- -- --- <br />-----D.E, RIGID 3#1 UP T <br />T - -- <br />1 4V 14VD2.5/6abc <br />i <br />45 KVA <br />i <br />------Lj <br />- <br />�, <br />Ld <br />- ' <br />� <br />-- <br />I I I - <br />U 3V51-4VD2-D/6 be If <br />99 �i III I ( I 9 9 <br />IS3V51 -3vC2/#7 g 11 I' 3V5 1 <br />O# O 2 , 3V51-3VD2-D 12abc ri 1i2 r 1 GRS, 6 1 1I,OG �� ;! i 3/4 C, 3#i <br />Ii ! 9 <br />® 1 E116LE6d7-7-! f I /h3/4 C, 3# 10, # 10iG L l <br />i <br />TANK HEATER C ; I' y ', 'i I 0 !! <br />'®A ! -- <br />PIW®EMCS INT. PNL!CONTACTOR c 12ab -- - - <br />! I <br />, <br />-- - -- <br />�\ h <br />------- I- - " <br />! 3 4C, 4 #14, #14G <br />I I <br />HT1 r <br />4I1 <br />II I� <br />rr 1 r\ <br />lli <br />co <br />EV 1495-1 <br />' 10,000 GAL, WASTE TANK <br />FIRST FLOOR PLAN <br />N <br />-21 SCALE: 1 /S"® 1 y -®®" <br />CL <br />J <br />1-1 <br />SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br />- AS -BUILT 964058--02 CANADA 7-7-96 E 5000 WW TANK REPLACEMENT AS -BUILT 12014767 RT 3/2/12 <br />K PIW UPGRADES ADDENDUM A DCN-01 20808468 CASNE EEK 04.30.21 F HEX CROME REDUCTION 102506-00 CASNE 12.07.11 <br />0 <br />G 40-51 APRON 400A SHUNT TRIP 11060028 AKC TT/WRL 5/10/12 <br />C 5000 WW TANK REPLACEMENT - FOR BID ONLY 12014767 RT NJK/BAO 8/26/11 H GENERATOR SYSTEMS-GENSET#3 RECORD 11649786 SAZAN/PT 10.14.14 <br />D EDC STALL CAPACITY 40-51 APRON 10607711 AKC TT/FB 1/31/12 J PIW UPGRADES - ADDENDUM A 20808468 CASNE EEK 01.25.21 <br />vp I <br />- TO 767 <br />41 /43 <br />FANS <br />I <br />F i <br />i <br />i <br />®3/4"C-3#1 <br />li <br />,! 41#14, #10' <br />GND <br />II <br />� I,0,r <br />N <br />3/4" <br />RGS, <br />3#8, 4# 14, <br />#12 <br />GND <br />SF�33 <br />3/4" <br />RGS, <br />3# 10, 4# 14, <br />I <br />I <br />#12 <br />GND <br />!I <br />7.5HP <br />r <br />:rt <br />! <br />130A <br />EXP <br />! 3/4" <br />RGS, <br />3#8, <br />4# 14, <br />! ! <br />#12 <br />GND <br />L d <br />i I <br />j <br />! 3 I u F, <br />I <br />I <br />- - U P TO ELECTR <br />MEZZ <br />I <br />D <br />LEGEND, <br />SEE SHEET EQa FOR GENERAL LEGEND. <br />gg S <br />GENERAL NOTES: <br />1, ELEVATION 37'-0" AND ABOVE IS RATED AS <br />NON -HAZARDOUS UNLESS NOTED OTHERWISE. <br />2. CONDUIT: <br />ABOVE 37'-0" IS 1 /2" EMT UNLESS NOTED <br />OTHERWISE. <br />BELOW 37'-0" IS 1 /2" GRS UNLESS NOTED <br />OTHERWISE. <br />3. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, <br />INSULATION TYPE THHN/THWN, UNLESS NOTED <br />OTHERWISE. <br />4. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS <br />WHICH DO NOT HAVE APPROPRIATELY COLORED <br />INSULATION WITH COLOR TAPE WHEREVER <br />CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED <br />GROUND CONDUCTORS USING COLORED TAPE. COLOR <br />CODE AS FOLLOWS: <br />208Y/120V 480Y 277V <br />I . <br />AO (LEFT BUS IN PNL) BLACK BROWN <br />BO (CENTER BUS IN PNL) RED ORANGE <br />CO (RIGHT BUS IN PNL) BLUE YELLOW <br />NEUTRAL WHITE GRAY <br />EQUIPMENT GROUND GREEN GREEN <br />ISOLATED GROUND GRN/YEL* GRN/YEL* <br />*GREEN WITH YELLOW TRACER <br />EL> WASTEWATER PUMP - RELIANCE #NP1426XP. 25 <br />HP, 30 48OV, 28.5A, <br />CONSTRUCTION NOTES: <br />PROVIDE AND INSTAL <br />'�� r <br />i <br />i ,. l , <br />1 EXPLOSION PROOF 1OOA <br />L X <br />NON --FUSED DISCONNECT SWITCHES WITH "EARLY <br />BREAK" AUXILIARY CONTACTS. MIN 75 DEGREE <br />LUGS. MOUNT HANDLE AT 48"-56" AFF. <br />2 PROVIDE EXPLOSION PROOF 2-POSITION <br />"HAND -AUTO" SWITCH. SPRING RETURN TO AUTO. <br />CONNECT WITH 3/4"C TO DISCONNECT. <br />3 PROVIDE AND INSTALL CONDUIT AND WIRE TO <br />PUMP MOTORS. UTILIZE 1" EXPLOSION PROOF <br />FLEX CONDUIT FOR MOTOR TERMINATION. <br />4 <br />V INSTALL NEMA 4X COMBINATION PROVIDE AND N NS , <br />HEAT CONTACTOR WITH INTEGRAL DISCONNECT. <br />INCLUDE AUX SWITCH CONTACT, 30A CONTACTOR <br />WITH AUX CONTACTS, SEE DETAIL FOR ADDITIONAL <br />REQUIREMENTS. <br />5 PROVIDE AND INSTALL OUTDOOR RATED AMBIENT <br />AIR TSTAT. CONNECT TO HEATER CONTACTOR <br />ENCLOSURE WITH 3/4"C & 2#12 + GRND WIRE. <br />6 PROVIDE AND INSTALL 3/4" CONDUIT AND WIRE <br />FROM DISCONNECT TO TANK HEATER. ROUTE <br />UNDERGROUND TO PREVENT TRIP HAZARD. <br />UTILIZE LIQUID TIGHT FLEX FOR FINAL CONNECTION <br />TO HEATER. <br />PR <br />OVIDE AND INSTALL �- <br />PUMP P-10 HOMERUN <br />7 <br />CONDUIT AND WIRE TO AREA NEAR EXISTING <br />PUMPS P7 & P8. INTERCEPT AND CONNECT NEW <br />CONDUIT TO EXISTING SPARE RISER CONDUIT TO <br />THE 3RD LEVEL MEZZANINE AND ROUTE TO VFD, <br />8 PROVIDE AND INSTALL PUMP P-9 HOMERUN <br />CONDUIT AND WIRE TO AREA NEAR EXISTING <br />PUMPS P7 & P8. INSTALL NEW 1" RISER <br />CONDUIT UP TO 3RD FLOOR AND ROUTE TO VFD. <br />9 PROVIDE AND INSTALL HEATER HOMERUN CONDUIT <br />AND WIRE TO AREA NEAR EXISTING PUMPS P7 & <br />P8. INTERCEPT AND CONNECT NEW CONDUIT TO <br />EXISTING SPARE 3/4" RISER CONDUIT TO THE 3RD <br />LEVEL MEZZANINE, THEN ROUTE TO PANELBOARD. <br />Engineering <br />FIRST FLOOR <br />3545 F"ACTORIA BOULEVARD SE., SUITE 200 <br />BELLEVUE, WA 98006 <br />c_- <br />BUILDING 40 - 51 <br />(425) 522-1000 WWW.CASNE. COM JOB NO. 191- 089 <br />� <br />ACCEPTABILITY <br />DRAwN <br />L. BARTON <br />DATE SUBTITLE <br />7-7--96 <br />T / T� <br />CURRENT REVISION <br />208084 68 <br />SYMBOL <br />I� <br />i\ <br />DATE <br />04.30.21 <br />®A�t�&� <br />THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />CHECKED <br />A. COWARD <br />7-7-96 <br />SHEET <br />APPROVED 8Y <br />DEPT. <br />DATE <br />ENGINEER <br />TITLE PIW UPGRADES - ADDENDUM A <br />1E116 <br />`w <br />CHECKED <br />c <br />35276 <br />BUILDING <br />051 <br />JOB NO. <br />COMP NO. <br />APPROVED <br />j� <br />IST <br />®�� <br />APPROVED <br />ELECTRICAL MASTER COL. BK-D/1-3 EVERETT, <br />WA ®w� N® 40-051-1 E116 <br />