My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2021 BLDG 40-51 Plans 2023-01-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-51
>
Plans
>
3003 W CASINO RD 2021 BLDG 40-51 Plans 2023-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 4:18:41 PM
Creation date
1/24/2023 11:06:29 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-51
Permit
B2105-016
Year
2021
Notes
UPGRADE PIW SYSTEM IN BASEMENT OF 40-51 BLDG / INSTALL NEW
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LCG,-fJD <br />SEE SHEET EOa FOR GENERAL LEGEND. <br />i <br />L <br />O <br />1 <br />O <br />0 <br />v <br />u <br />Ld <br />0 <br />0 <br />1 <br />v <br />0 <br />1 <br />0 <br />d <br />1 <br />00 <br />I <br />i <br />i <br />v <br />0 <br />V) <br />Ld <br />0 <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE SYM <br />REVISION <br />BY <br />K <br />ADD DUPLEX 10607711 <br />AKC <br />BC/FB <br />2/24/12 E <br />REARRANGE KITTING ROOM 52424300 <br />JSH <br />L <br />GENSET#3 RESUBMIT 11649786 <br />SAZAN/PT <br />JJ <br />05.07.16 F <br />REPLACE 747 PLENUM WALL 9378378 <br />RT <br />M <br />N <br />PIW UPGRADES — ADDENDUM A 20808468 <br />PIW UPGRADES ADDENDUM A — DCN-01 20808468 <br />CASNE <br />CASNE <br />EEK <br />EEK <br />01.25.21 G <br />04.30.21 H <br />STALL CAPACITY 40-51 APRON 10607711 <br />SARTORIUS SCALES INSTALLATION W452723 <br />AKC <br />6DH <br />J <br />EDC STALL CAPACITY 40-51 106077111 <br />AKC <br />®� WA <br />KEY PLAN <br />FIRST FLOOR <br />BUILDING 40-51 <br />DRAWN DATE SUBTITLE <br />ACCEPTABILITY L. BARTON 07.07.96 <br />THIS DESIGN AND/OR CHECKED <br />SPECIFICATION IS APPROVED A. COWARD 07.07,96 <br />ENGINEER TITLE <br />'PROVED DY DEPT. DATE <br />PIW UPGRADES - ADDENDUM A <br />Int" oll"i -.lilll <br />,ter <br />lm 1 <br />GENERAL MOTES <br />1. ELEVATION 37'-0" AND ABOVE IS RATED AS <br />NON -HAZARDOUS UNLESS NOTED OTHERWISE. <br />2. CONDUIT: ABOVE 37'-0" SHALL BE 1 /2" EMT UNLESS <br />NOTED OTHERWISE, BELOW 137'-0" SHALL BE 1 /2" <br />GRS UNLESS NOTED OTHERWISE. <br />3. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, <br />INSULATION TYPE TYPE THHN/THWN, UNLESS NOTED <br />OTHERWISE. <br />4. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS <br />WHICH DO NOT HAVE APPROPRIATELY COLORED <br />INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS <br />ARE ACCESSIBLE. IDENTIFY INSULATED GROUND <br />CONDUCTORS IN ACCORDANCE WITH THE LATEST NEC <br />(USING TAPE). COLOR CODE AS FOLLOWS: <br />206Y 120V <br />480Y 277V <br />AO (LEFT BUS IN PNL) <br />BLACK <br />BROWN <br />BO (CENTER BUS IN PNL) <br />RED <br />ORANGE <br />CO (RIGHT BUS IN PNL) <br />BLUE <br />YELLOW <br />NEUTRAL <br />WHITE <br />CRAY <br />EQUIPMENT GROUND <br />GREEN <br />GREEN <br />ISOLATED GROUND <br />GRN/YEL* <br />GRN/YEL* <br />*GREEN WITH YELLOW TRACER <br />REFERENCE NOTES <br />1� ADT CONDUIT TO TRAILERS —SEE DRAWING <br />40—YD—E110-52. <br />2 FLAMMABLE OR HAZARDOUS MATERIAL IN SEALED <br />CONTAINERS SHALL NOT BE PLACED WITHIN 10 <br />FEET OF EITHER RECEPTACLE. (AUTH: A.W. RICHTER <br />MEMO, dtd 09/25/98). <br />3 WEST PENN WIRE MODEL D990, #16AWG LOW CAP. <br />(1 BpF/FT) TWISTED PAIR, JACKETED CABLE (.223" OD) <br />4 <br />BELDEN <br />#3107A <br />(RS485 CABLE, (2) TWISTED SHIELDED <br />PAIRS, <br />22 AWG, <br />120 OHM IMPEDANCE (.356 OD <br />5 <br />40-51-E607-6 <br />PIW CONTROLS DETAILS <br />CONSTRUCTION NOTES <br />PROVIDE AND INSTALL PNEUPAERCATOR LEAK <br />DETECTION PANEL IN LOCATION OF OLD SOIL <br />SENTRY PANEL. SEE CONTROL DRAWINGS FOR FULL <br />REQUIREMENTS. <br />2 REUSE EXISTING CONDUIT FROM REMOVED LEAK <br />PANEL TO 120V PANELBOARD. PROVIDE AND <br />INSTALL NEW CONDUCTORS. PROVIDE 3 GROUND <br />WIRES, AS INDICATED, <br />3� NOT USED. <br />4 PROVIDE AND INSTALL PIW—EMCS INTERFACE PANEL <br />ADJACENT TO EMCS PANEL. <br />5 PROVIDE AND INSTALL HOMERUN CONDUIT AND <br />WIRE BACK TO PANELBOARD. <br />6 PROVIDE AND INSTALL A SPARE, UNDERGROUND <br />1 " CONDUIT BETWEEN WALL AND TANK. PROVIDE <br />OUTDOOR RATED JBOX ON WALL. CAP AT TANK. <br />7. PROVIDE AND INSTALL EXPLOSION PROOF CONDUIT <br />SEALS PER THE NEC, ARTICLE 500. <br />THE REQUIREMENT TO ADD AN EMCS PANEL HAS <br />BEEN REMOVED FROM THIS PROJECT. A NEW <br />EMCS PANEL WAS ADDED ON THE SOUTH WALL OF <br />THE MEZZANINE ON A PREVIOUS PROJECT, <br />cc <br />a <br />CN <br />I: <br />cc <br />r- <br />I <br />
The URL can be used to link to this page
Your browser does not support the video tag.