Laserfiche WebLink
(3) <br />(1) 1 /2" QD <br />1 "A DN THROU( <br />(3) 1 /4" <br />(1) 1 /4" DRY AIR <br />(1) 1 /2" QD W/ S <br />1"A DN THROUG <br />NEW SHEET <br />A -DECK PARTIAL PLUMBING PLAN <br />SCALE: 1:50 <br />WoF ti As <br />Kenne h� <br />21897 <br />4 3 � �GISTs <br />�S71pAAL I <br />REV REVISION DESCRIPTION <br />0 RRO — 767 RATE INCREASE AFT SI — IFC <br />1 RR1 — 767 RATE INCREASE AFT SI — IFP <br />i <br />F_ <br />LEGEND <br />SCV SAFETY CHECK VALVE <br />QD QUICK DISCONNECT <br />GENERAL MOTES <br />CONSTRUCTION NOTES <br />1/ MOUNT QD'S ON UNISTRUT SUPPORTS <br />APPROXIMATELY 3'-0" ABOVE DECK. <br />UNDER TAIL ACCESS HATCH ALONG TOOL STEEL. <br />CONTRACTOR SHALL FIELD VERIFY LOCATION <br />WITHIN HATCH TO AVOID CONFLICTS. <br />PROVIDE CLASS 1, DIVISION 1 RATED SOLENOID <br />VALVE UP STREAM FROM THE QDs FOR <br />CONTROL OF SPRAYED COATING APPLICATION <br />SEQUENCE. <br />A -DECK PARTIAL PLUMBING PLAN <br />767 RATE INCREASE - AFT SI <br />40-32 BUILDING, COL E16-17 <br />AUTHORIZATIONS <br />DESIGNER, DCS <br />CHECKER: DCS <br />APPROVAL! KMB <br />BRPH <br />www.brph.com Copyright © 2019 <br />Architects Engineers, Inc. <br />19020 33 d Ave W; Suite 530 State of Washington <br />Lynnwood, Washington, 98036 Ce Architecture <br />of Authorization <br />425-921-3500 Architecture No.313235512 <br />Engineennp No.3137 <br />IDM <br />PRODUCT <br />TYPE. <br />TDISCIPLINEi MECHANICAL <br />DATE <br />PLL7TTED+ 08/27/2019 <br />STATUS; IFP <br />STATUS / / <br />08 27/ 2019 <br />DATE; <br />TDESIGN <br />PTIDN ID+ <br />REVISIONS <br />SCALE 1 , 50 <br />ALL DIMENSIONS IN INCHES <br />ORG. NO. <br />CONCURRENCE <br />DATE <br />FINISH <br />COLOR OR PROTECTIVE <br />SECTION <br />13 <br />SHT SIZE <br />REV <br />REV <br />DATE <br />MODEL <br />0 <br />08/16/19 <br />EXCEPT AS NOTED <br />TOLERANCES MACHINE <br />DECIMA+ FINISH <br />X <br />XX =± 7 <br />,xxx=+ ���%%%% <br />ANGULAR =t SEE TDM <br />1 <br />08/27/19 <br />-- 0 C� L— T-7 F` W = f--J C= <br />BCAG EVERETT DIVISI❑N <br />NAME <br />DATE <br />DESIGNED <br />D. SMITH <br />08/27/19 <br />PARTIAL PLUMBING PLAN <br />BODY SECTIONS 46/48 <br />DETAILED <br />D. SMITH <br />08/27/19 <br />FLOOR AREA <br />APPROX WT <br />CHECKED <br />D. SMITH <br />08/27/19 <br />SEE SHT 1 <br />SEE SHT 1 <br />APPROVED <br />K. BENHAM <br />O8/27/19 <br />CHO NO <br />USED ON <br />WORK ORDER EVE-18-30055-601 <br />APPROVED <br />FME1 40T0000-8000 <br />DWG NO. SHT NO. M 0 3OF <br />DRAWING NO <br />SHEET <br />REV <br />NOR <br />FILE <br />NAME; <br />EVERETT FACILITIES SERVER <br />LAST PROD DRAWING CHANGE <br />NO <br />MODEL <br />NAME <br />FME140T0000-8000_M03 <br />EI <br />