My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-32 Plans 2023-01-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-32
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-32 Plans 2023-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 3:49:26 PM
Creation date
1/25/2023 11:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-32
Permit
B1909-030
Year To
2019
Notes
STRUCTURAL SUPPORT OF CORROSION INHIBITOR COMPOUND EXHAUST
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
w <br />In <br />—i <br />w <br />w <br />N <br />BAL DE K CIC VENTILATION PLAN N <br />LEGEND <br />GENERAL NOTES <br />1. ALL ABOVE GROUND CIC EXHAUST DUCTWORK IS SPRINKLERED. SEE FIRE <br />PROTECTION DRAWINGS, PROVIDE WATER PRESSURE RELIEF DOORS AT ALL LOW <br />POINTS IN EXHAUST DUCTWORK. PROVIDE DUCT ACCESS DOORS PER <br />SPECIFICATIONS. <br />2. ALL ABOVE GROUND CIC DUCT WORK SHALL BE ROUTED MINIMUM 6" FROM <br />COMBUSTIBLE CONSTRUCTION. <br />3. CIC EXHAUST DUCTWORK SHALL BE 14 GAUGE GALVANIZED DUCTWORK, <br />PROVIDE WITH NO INTERNAL SUPPORTS, CONSTRUCT SUPPORT AND <br />CONNECTIONS PER SMACNA DUCT CONSTRUCTION STANDARDS AT -10" STATIC <br />S PRESSURE CLASS AND SEAL CLASS A. <br />5 <br />PUSH BUTTON CONTROL SWITCH, ROCKWELL AUTOMATION 800H DIE CAST <br />ALUMINUM ENCLOSURE WITH AMBER "RUN" LIGHT, "START", AND "STOP" <br />BUTTONS AND RED "FILTER FAULT" LIGHT. LABEL SIMILARLY, ONE FOR EACH <br />S OF TWO LOCATIONS. <br />6 <br />S BLUE STROBE LIGHT, SEE ELECTRICAL FOR 120V CONNECTION. <br />7 <br />AIR MONITORING CORP VOLU PROBE AIR FLOW MEASURING STATION. <br />CONSTRUCTION NOTES <br />SWITCH FURNISHED BY HONEYWELL INSTALLED BY GENERAL CONTRACTOR. CONNECT <br />TO ELECTRIC J-BOX. <br />2�INSTALL <br />BLUE STROBE LIGHT AT 84" ABOVE THE FLOOR. <br />3i <br />PROVIDE DUCT SIZED CONTROL DAMPER, CL 1A LEAKAGE, 10" W.G. RATED <br />DIFFERENTIAL PRESSURE, PARALLEL AIR -FOIL BLADES, GALVANIZED STEEL. RUSKIN <br />MODEL CD60 OR EQUAL. DAMPER OPERATOR: 2-POSITION, SPRING RETURN, 180 <br />IN -LB TORQUE, NEMA 2/IP54, BELIMO MODEL AFBUP-S, OR EQUAL. PROVIDE <br />PROTECTION FOR DAMPER OPERATOR EQUIVALENT TO NEMA12. <br />L% <br />AIR FLOW MEASURING STATION FURNISHED BY HONEYWELL, INSTALLED BY GENERAL <br />CONTRACTOR. PROVIDE MIN 5FT OF STRAIGHT DUCT LENGTH UPSTREAM OF AIR <br />FLOW MEASURING STATION. <br />TRANSITION DUCT TO MATCH FAN DISCHARGE SIZE, PROVIDE FLEXIBLE CONNECTION. <br />6. <br />SUPPORT DUCTWORK FROM TOOL DECK. <br />REFERENCE DRAWINGS <br />1. 40-032-M313 <br />2. 40-032-M314 <br />- - --- �F_ <br />NEW SHEET B-DECK CIC VENTILATION PLAN <br />767 RATE INCREASE -AFT SI <br />40-32 BUILDING, COL E16-17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.