My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-32 Plans 2023-01-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-32
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-32 Plans 2023-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 3:49:26 PM
Creation date
1/25/2023 11:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-32
Permit
B1909-030
Year To
2019
Notes
STRUCTURAL SUPPORT OF CORROSION INHIBITOR COMPOUND EXHAUST
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REV I REVISI❑N DESCRIPTI❑N <br />0 1 RRO — 767 RATE INCREASE AFT SI — IFC <br />AUTH❑RIZATI❑NS <br />-d <br />w <br />w <br />T <br />N <br />�r <br />IN <br />FLOOR LEVEL FIRE PROTECTION PLAN <br />SCALE: 1:50 <br />NEW SHEET <br />LEGEND <br />GENERAL NOTES <br />DESIGNER: DCS <br />CHECKER; DCS <br />APPROVAL! KMB <br />1. THIS DRAWING IS SERVED BY RISER SV32-13 LOCATED NEAR COL. E-16.5. <br />2. THE BOEING EVERETT FIRE INSPECTION DEPARTMENT (206-655-8800) SHALL BE NOTIFIED 24 <br />HOURS IN ADVANCE OF ALL VALVE CLOSURES, FLUSHING, AND HYDROSTATIC TESTS ON THE <br />FIRE PROTECTION SYSTEM. THE MAXIMUM DURATION OF A SYSTEM CLOSURE IS 8 HOURS <br />UNLESS PERMISSION IS GRANTED BY THE FIRE CHIEF, <br />3, PROVIDE A MATERIAL AND TEST CERTIFICATE UPON COMPLETION OF THE TESTING. THE <br />CERTIFICATE SHALL BE SIGNED OFF BY THE BOEING EVERETT FIRE INSPECTOR DEPARTMENT <br />PRIOR TO COMMENCING ADDITIONAL WORK ON THE FIRE PROTECTION SYSTEM. <br />4. PIPE HANGERS SPACING SHALL BE PER NFPA 13. <br />5. ALL SPRINKLER PIPING 3" AND SMALLER SHALL BE SCHEDULE 40 ASTM A-53 GRADE B <br />BLACK STEEL. ALL PIPING 4" AND LARGER SHALL BE ASTM A-53 SCHEDULE 40 FOR <br />VERTICAL RISERS AND SCHEDULE 10 FOR HORIZONTAL. MAINS AND CROSS MAINS. <br />6. SPRINKLER SYSTEM PIPE FITTINGS SHALL BE 150 LB. THREADED MALLEABLE IRON FOR <br />1-1/2" AND SMALLER, AND VICTAULIC GROOVED FITTINGS FOR 2-1/2" AND LARGER. PIPE <br />FITTINGS FOR 2" MAY BE EITHER 150 LB. THREADED MALLEABLE IRON OR VICTAULIC <br />GROOVED. <br />7. COUPLINGS FOR GROOVED PIPE AND FITTINGS SHALL BE VICTAULIC STYLE 07 ZERO —FLEX <br />UNLESS OTHERWISE NOTED. <br />8. HYDROSTATIC TEST: PRESSURE — 225 PSIG, DURATION — 2 HOURS. <br />9. SEISMIC BRACING SHALL BE INSTALLED IN ACCORDANCE WITH FM STANDARDS. SEE FM DATA <br />SHEETS 2-8, "EARTHQUAKE PROTECTION FOR WATER —BASED FIRE PROTECTION SYSTEMS" FOR <br />SPECIFIC DETAILS. SPRINKLER DESIGN SHALL BE IN ACCORDANCE WITH THE LATEST VERSIONS <br />OF NFPA 13 AND FM GLOBAL DATA SHEET 2-0. <br />10. AUTOMATIC SPRINKLER HEADS SHALL BE 155 — 165 DEGREE F. TEMPERATURE RATED. <br />11. ALL EQUIPMENT SHALL BE UL LISTED AND FM APPROVED FOR FIRE SERVICE. <br />REFERENCE DRAWINGS <br />CONSTRUCTION NOTES <br />1. CONTRACTOR SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, <br />AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS TO AVOID CONFLICTS <br />PRIOR TO BEGINNING THE WORK. <br />2. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS SHALL <br />BE CALLED TO THE ATTENTION OF BRPH. <br />3, CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN <br />ACCORDANCE WITH ALL OSHA AND BOEING STANDARDS. <br />4, ROUTE FIRE PROTECTION PIPE ALONG TOOL STEEL. <br />5, COORDINATE SPRINKLER HEAD PLACEMENT AND PIPE ROUTING WITH ALL DISCIPLINES, <br />INCLUDING NW AND EXISTING MECHANICAL AND ELECTRICAL DISCIPLINES. <br />© PROVIDE PERMANENT SPRINKLER PIPING, MOUNTED ON TOOL. THE SPRINKLER HEADS <br />MUST PROVIDE COVERAGE FOR THE ENTIRE SURFACE OF THE AFT SI FUSELAGE SECTION, <br />INCLUDING AT OPEN ENDS AND ALONG FULL LENGTH. <br />7. DEFER FIRE PROTECTION PIPE SIZING AND ARRANGEMENT TO LICENSED FIRE PROTECTION <br />CONTRACTOR. <br />8. PROVIDE WET PIPE FIRE SPRINKLER PROTECTION THROUGHOUT THE TOOL SHOWN ON <br />THIS DRAWING IN ACCORDANCE WITH NFPA-13 AND BOEING FIRE DEPARTMENT <br />REQUIREMENTS. PROVIDE FIRE SPRINKLERS UNDER ALL GRATED AREAS AND UNDER ALL <br />PLATFORMS. LOCATE SPRINKLER PIPING IN A NEAT MANNER AND TO PROVIDE ADEQUATE <br />CLEARANCE FOR PERSONNEL AND EQUIPMENT. COORDINATE PIPE ROUTING WITH ALL <br />DISCIPLINES AND PROVIDE ADDITIONAL OFFSETS AND SPRINKLERS AS REQUIRED. PROVIDE <br />AUXILIARY DRAINS PER NFPA-13. <br />9. PROVIDE FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH BOEING FIRE PROTECTION <br />ENGINEERING STANDARD 038108—F, NFPA-13, FM 2-8 AND FM 2-8N, APPLICABLE <br />CODES AND BOEING FIRE DEPARTMENT REQUIREMENTS, THE FIRE SPRINKLER <br />CONTRACTOR SHALL PREPARE FIRE SPRINKLER SHOP DRAWINGS AND HYDRAULIC <br />CALCULATIONS IN ACCORDANCE WITH THESE STANDARDS AND SUBMIT TO BOEING FIRE <br />PROTECTION ENGINEERING FOR APPROVAL AND PERMIT. <br />10. FIRE SPRINKLER SHOP DRAWINGS SHALL INCLUDE THE SPRINKLER CONTROL VALVE TAG <br />AND LOCATION FOR THE CONTROL VALVE THAT SERVES THE AREA. <br />FLOOR LEVEL FIRE PROTECTION PLAN <br />767 RATE INCREASE - AFT SI <br />40-32 BUILDING, COL E16-17 <br />,U <br />cr-:, <br />SD <br />PH <br />www.brph.com Copyright © 2019 <br />Architects Engineers, Inca <br />19020 33rd Ave W, Suite 530 Stale of Washington <br />Lynnwood, Washington, 98036 Certificate e No. 60ri23551 <br />425-921-3500 Architecture No.313235512 <br />Enaineerina No. 3137 <br />PRODUCT <br />TYPE1 <br />DISCIPLINE; MECHANICAL <br />DATE <br />08 16 2019 <br />PLO TTED; // <br />STATUS: IFC <br />STATUS <br />08 16 2019 <br />DATE: // <br />DESI GN <br />OPTION ID; <br />REVISIONS <br />SCALE <br />1 .50 <br />ALL DIMENSIONS IN INCHES <br />❑RG, NO, <br />CONCURRENCE <br />DATE <br />FINISH <br />COLOR OR PROTECTIVE <br />SECTION <br />13 <br />SHT SIZE <br />0 <br />REV <br />REV <br />DATE <br />MODEL <br />0 <br />08/16/19 <br />EXCEPT AS NOTED <br />TOLERANCES MACHINE <br />DECIMAL FINISH <br />X =± <br />XX =± <br />ANGULAR V <br />ANGULAR =± SEE TDM <br />r--J <br />BCAG EVERETT DIVISI❑N <br />NAME <br />DATE <br />DESIGNED <br />D. SMITH <br />08/16/19 <br />FIRE PROTECTION rl <br />SYSTEM <br />BODY SECTIONS 46/48 <br />DETAILED <br />D. SMITH <br />08/16/19 <br />FLOOR AREA <br />-- <br />APPROX WT <br />CHECKED <br />D. SMITH <br />08/16/19 <br />SEE SHT 1 <br />SEE SHT 1 <br />APPROVED <br />K. BENHAM <br />08/16/19 <br />PROD <br />CHG NO <br />USED ON <br />RK <br />ORDER ORDE BA# EVE-18-30055-601 <br />it <br />APPRovED <br />FME1 40T0000-8000 <br />DWO NO, SHT NO, M 0 70F <br />DRAWING N❑ <br />SHEET <br />REv <br />_ <br />NOR <br />NAME <br />I EVERETT FACILITIES SERVER <br />LAST PROD DRAWING CHANGE <br />NO <br />NAME <br />I FME140T0000-8000_MO7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.