Laserfiche WebLink
REV REVISI❑N DESCRIPTI❑N <br />0 RRO — 767 Rate Increase AFT SI — IFC (EVE-18-30055-601) <br />1 RRO — 767 Rate Increase AFT SI - Issue For Permit (EVE-18-30055-601) <br />LIGHT FIXTURE SCHEDULE <br />TYPE <br />1 DESCRIPTION <br />MOUNTING <br />FIXTURE <br />VOLTAGE <br />LAMPS <br />BALLAST <br />1 MANUFACTURERS CATALOG <br />SERIES NUMBER <br />REMARKS <br />SYMBOL <br />TYPE <br />QTY. <br />E <br />VAPOR—TITE 48" FLUORESCENT LUMINAIRE WITH LED <br />LAMP RETROFIT KIT <br />BY OTHERS <br />120V I <br />1 <br />14W LED <br />2 <br />LAMP WITH INTEGRATED <br />LED DRIVER <br />METALUX <br />#VT2-232DR-12OV—GL <br />MOUNT ON STRUT BELOW DEC <br />64 <br />E2 <br />FLOORESCENT 48" VAPOR —TIGHT LUMINAIRE, NO <br />BALLAST, WITH LED LAMP RETROFIT KIT <br />SURFACE <br />120V <br />14W LED <br />2 <br />LAMP WITH INTEGRATED <br />LED DRIVER <br />LIGHTS N PLASTICS SENTRY SERIES <br />VT4S-232 PRE —WIRED, WITH <br />TOMBSTONES. NO BALLAST. NO LAMPS. <br />HIGH IMPACT ACRYLIC <br />LENS <br />24 <br />. , ..x..,.....a.r... <br />_ ....,.x,.°... w,.z,.s.z,�...__�. _�=M..�z,�.��__a��� ���,, <br />i <br />I <br />I <br />1 <br />11 <br />1Ic" <br />11c <br />r 11c <br />, 9b <br />{: <br />b <br />9b <br />9b <br />R6 <br />1fi <br />R6 <br />R6 <br />■:I R5 <br />R5 <br />iR5 <br />R5 <br />, <br />' <br />1R6 <br />II <br />1 Ic <br />R6 <br />f 11c <br />R6 <br />W(TYP) 11c W(TYP) <br />R6 <br />r <br />I I ' 9b <br />R5 <br />9b <br />R5 <br />9b <br />R5.=_= <br />�(TYP) <br />9b �(TYP)' <br />R5 <br />------ <br />! <br />yy _ <br />I <br />— <br />E2 <br />I <br />1` <br />2 <br />64 <br />E2 <br />24 <br />I <br />(TYP) is (TYP) <br />i' I , <br />(TYP) <br />(TYP) >, r <br />."T W i LL, I <br />11c II 11c I 11c 11c �It,9bb b 9b <br />R6 I, R6 ii R6 _ ;; R5 5 <br />F5 R5 <br />- — -- <br />` <br />t• 11 <br />Mw iiiiimiiiiii r i• '. **mm iiiiim t•r m, iiiiiiiiimiiii t• fit• (• II I <br />Ij ,i I I <br />40.E r.o%, I"=.i.ir_NNOW, <br />If <br />I r I I � <br />1R8 1R8 1R8 15b �.1,.-13a 130 13a 13a <br />R8R7 R7 R7 <br />- -- <br />'I t; _:- _ _ �. -__ - - <br />, <br />I <br />( I <br />( <br />° <br />I <br />I <br />.� ?- <br />I � I✓' !I � 3 ���, h! \� !� :�'� ,I I 1; _ l —� � I I i it I I I <br />C G. C 'L' C C C_µ_C_ � C <br />I <br />„ ?I � li i - -__ `__---___I— ��. � IL.�1__— _.. _�_ _ ,; ._ <br />�' 1/2 C, 6#14�— <br />,, 100 ® 100 3/4"C, 8#12 & 1#12 GNDj -- TO LIGHTING CONTROL PANEL -- <br />E1 E902-2 45kVA TO 2V32-1BE16-3/9b,11c�13a,15b LCP-2V32-1-2 (' <br />2V32-1BE16-3 4V32-1BE16-3 VIA LCP-2V32-1BE16-2 PANEL <br />LIGHTING CONTROL PANEL (LIGHTING PANEL) CONTROLLED BY SWITCH "PSW1" <br />LCP-2V32-1BE16-2 2V32-1BE16-4 <br />(POWER PANEL) <br />i <br />i <br />BACK TO BRANCH <br />CIRCUIT WIRING <br />DETAIL <br />NOTES: <br />JHNFEMALE <br />1 <br />REMOVE FIXTURE BALLAST IF PRESENT AND WIRE INCOMING BRANCH CIRCUIT <br />FIXTURE DISCONNECT <br />HOT AND NEUTRAL DIRECTLY TO FIXTURE DISCONNECT. MALE SIDE (ORANGE <br />(IDEAL P/N POWERPLUG 102) <br />I <br />END) OF DISCONNECT SHALL BE ON THE INCOMING BRANCH CIRCUIT AND <br />ON THE FIXTURE WIRING (NO SUBSTITUTIONS.) <br />PROVIDE IN —LINE FUSE HOLDER WITH FUSE AND WIRE AS SHOWN TO <br />3 = FIXTURE <br />GROUND <br />DISCONNECT AND TOMBSTONE WIRING. <br />2A IN LINE FUSE AND HOLDER (BUSSMAN <br />a POINT <br />3 <br />WIRE NEUTRAL TOMBSTONE TO FIXTURE DISCONNECT. <br />P/N GMF-2 AND HLR) <br />I <br />WIRE GROUND TO FIXTURE GROUND SCREW/POINT. <br />INSTALL LED TUBES IN TOMBSTONES (NO SUBSTITUTIONS.) ORIENT TUBES SO <br />1<11 <br />HOT END OF TUBE IS INSERTED IN THE HOT TOMBSTONE AND NEUTRAL IN <br />THE NEUTRAL TOMBSTONE. (QTY. 2 PER FIXTURE) <br />LED T8 TUBES (SYLVANIA P/N <br />TOMBSTONES <br />LED 14T8/L48/FG/841/BF)� <br />TOMBSTONE <br />LIGHT FIXTURE <br />© <br />INSTALL FACTORY SUPPLIED LABEL ON THE EXTERIOR FACE OF THE LIGHT <br />BOUNDARY <br />FIXTURE NEAR THE HOT END TOMBSTONE. LABEL MUST BE VISIBLE WITHOUT <br />{ N <br />N <br />__j <br />REMOVAL OF TUBES OR FIXTURE PARTS. <br />LIGHTING <br />LED TUBE INSTALLATION <br />SCALE: NTS <br />_ <br />46 48 SECTION S & I FACTORY FLOOR PLAN nN <br />L <br />SCALE: 1:50 <br />�F WASgINc"tf�, <br />4 3 - ��. ���t��s <br />ArSIONAL <br />LEGEND <br />m <br />JUNCTION BOX, FIELD SIZED OR AS NOTED <br />0 <br />SPECIAL PANEL AS NOTED <br />® <br />PANELBOARD, 480V, 30, 3W, PANELBOARD <br />p <br />PANELBOARD, 480Y/277V, 30, 4W, PANELBOARD <br />m <br />TRANSFORMER, SIZE AND TYPE AS NOTED <br />$LV <br />LOW —VOLTAGE LIGHT SWITCH <br />Dj <br />FUSED DISCONNECT <br />C— <br />D <br />LIGHTING CIRCUIT REGION <br />GENERAL NOTES <br />1. FOR FIXTURE TYPES SEE DRAWING 40-031—EOb. <br />2. 1ST DECK IS ZONE 1. 2ND DECK IS ZONE 2. <br />3. ALL CONDUCTORS, JUNCTION BOXES AND OUTLET BOXES SHALL BE <br />CROUSE—HINDS CAST METAL BOXES. <br />4. UNLESS OTHERWISE NOTED ALL WIRING SHALL BE 1/2"C, 2#12 & 1#12 <br />GND. <br />5. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE <br />THHN/THWN, UNLESS OTHERWISE NOTED. <br />6. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE <br />APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER <br />CONDUCTORS ARE ACCESSIBLE" IDENTIFY INSULATED GROUND <br />CONDUCTORS PER NEC 250-57 EXCEPTION <br />b E CEP ON 1 b OR c USING TAPE). <br />COLOR CODE AS FOLLOWS: <br />120 208V 277 480V <br />"A" 0 (LEFT BUS IN PANEL) BLACK BROWN <br />"B" 0 (CENTER BUS IN PANEL) RED ORANGE <br />"C" 0 (RIGHT BUS IN PANEL) BLUE YELLOW <br />NEUTRAL WHITE GREY <br />EQUIPMENT GROUND GREEN GREEN <br />ISOLATED GROUNDYELLOW GRN/YEL* GRN/YEL* <br />*GREEN WITH YELLOW TRACER <br />7. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH <br />CIRCUIT IDENTIFICATION. <br />8. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. <br />9. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. <br />REFERENCE DRAWINGS <br />FLUURESCENT 48" VAPOR —TIGHT LUMINAIRE, NO <br />BALLAST, WITH LED LAMP RETROFIT KIT <br />LIGHTS N PLASTICS SENTRY SERIES <br />#VI4S PRE —WIRED, WITH <br />TOMBSTONES, NO BALLAST <br />CONSTRUCTION NOTES <br />1 __— PROVIDE LIGHTS N PLASTICS SENTRY SERIES #VT4S <br />PRE —WIRED WITH TOMBSTONES, AND NO BALLAST. REPLACE <br />EXISTING LUMINAIRES THAT ARE BROKEN AT LOCATIONS <br />SHOWN. SEE DETAIL 1 THIS SHEET. <br />2 EXISTING GE TLC LEVEL 3 LIGHTING CONTROL PANEL. SEE <br />DRAWING 40-032—E902-2 FOR WIRING DETAIL. <br />3 EXISTING LOW —VOLTAGE LIGHT SWITCHES. <br />USE EXISTING BRANCH CIRCUIT. <br />EXISTING 2—LAMP VAPOR—TITE 48" FLUORESCENT METALUX <br />#VT2-232DR-120V—GL. RETROFIT WITH LED LAMPS, SEE <br />1 DETAIL 1 THIS SHEET. <br />LIGHTING SYSTEM <br />46/48 SECTIONS & I FACTORY FLOOR PLAN <br />BUILDING 40-32, COL E16-17 <br />AUTH❑RIZATI❑NS <br />DESIGNERI VTB <br />CHECKER: SMS <br />APPROVAL: SMS <br />k . <br />r <br />mB'KPH <br />www.brph.com Copyright@ 2019 <br />Architects Engineers, Inc. <br />19020 33rd Ave W, Suite 530 State of Washington <br />Lynnwood, Washington, 98036 Cerfificate of Authorization <br />425-921-3500 Architecture No. 603235512 <br />Engineering No. 3137 <br />IDM <br />PRODUCT <br />TYPE: <br />DISCIPLINE, <br />DATE <br />PLOTTED <br />STATUS; <br />STATUS <br />DATE: <br />DESIGN <br />OPTION ID1 <br />REVISIONS <br />SCALE T <br />ALL DIMENSIONS IN INCHES <br />ORG, NO, <br />CONCURRENCE <br />DATE <br />FINISH <br />COLOR OR PROTECTIVE <br />SECTION <br />13 <br />SHT SIZE <br />1 <br />REV <br />REV <br />DATE <br />MODEL <br />G <br />D8/16/19 <br />1 <br />08/27/19 <br />EXCEPT AS NOTED <br />TOLERANCES MACHINE <br />DECIMAL FINISH <br />A =± 7 <br />xxx=± �VV/ <br />ANGULAR =t SEE TDM <br />T C=1 1 _ LD Fz <br />t <br />BCAG EVERETT DIVISI❑N <br />NAME <br />DATE <br />DESIGNED <br />V-B <br />08/27/19 <br />FLOOR MOUNTED EQUIPMENT <br />BODY SECTIONS 46 f 48 <br />DETAILED <br />SMS <br />08/27/19 <br />FLOOR AREA <br />APPROX WT <br />CHECKED <br />SMS <br />08/27/19 <br />SEE SHT 1 <br />=SEEHT 1 <br />APPROVED <br />PROD <br />CHG NO <br />USED ON <br />WORK ORDER EVE-18-30055-601 <br />APPROVED <br />FME140T0000-8000 <br />DWG NO: SHT NO. E01 OF <br />DRAWING No <br />SHEET <br />REV <br />NO <br />FILE <br />NAME, <br />EVERETT FACILITIES SERVER <br />LAST PROD DRAWING CHANGE <br />NOR <br />NAME <br />fine 140t0000-8000 e01 <br />O <br />