Laserfiche WebLink
0 <br />S <br />E <br />16) <br />BACK TO BRANCH <br />CIRCUIT WIRING <br />FIXTURE DISCONNECT <br />(IDEAL P/N POWERPLUG 102) <br />2A IN —LINE FUSE AND HOLDER (BUSSMAN <br />P/N GMF-2 AND HLR) <br />1 H <br />TOMBSTONES LED T8 TUBES (SYLVANIA P/N TOMBSTON <br />LED 14T8/L48/FG/841/BF)� <br />1 H <br />LIGHT FIXTURE SCHEDULE <br />TYPE <br />1 DESCRIPTION <br />MOUNTING <br />FIXTURE <br />VOLTAGE <br />LAMPS <br />BALLAST <br />1 MANUFACTURERS CATALOG <br />SERIES NUMBER <br />REMARKS <br />SYMBOL <br />TYPE <br />QTY. <br />E <br />VAPOR—TITE 48" FLUORESCENT LUMINAIRE WITH LED <br />LAMP RETROFIT KIT <br />BY OTHERS <br />120V <br />14W LED <br />2 <br />LAMP WITH INTEGRATED <br />LED DRIVER <br />METALUX <br />#VT2-232DR— 1 20V—GL <br />MOUNT ON STRUT BELOW DECK <br />----- ' <br />64 <br />E1 <br />48" EXPLOSTION—PROOF LED LUMINAIRE <br />SURFACE <br />120V <br />46W LED <br />120V — 277V <br />50/6OHz <br />RIG-A—LITE #XP-50L-4-2L—U <br />FEEDS REQURE RIGID <br />CONDUIT AND SEAL —OFFS <br />EXP <br />46 <br />E2 <br />FLUURESCENT 48" VAPOR —TIGHT LUMINAIRE, NO <br />BALLAST, WITH LED LAMP RETROFIT KIT <br />SURFACE <br />120V <br />14W LED <br />2 <br />LAMP WITH INTEGRATED <br />LED DRIVER <br />LIGHTS N PLASTICS SENTRY SERIES <br />#VT4S-232 PRE —WIRED, WITH <br />TOMBSTONES. NO BALLAST. NO LAMPS. <br />HIGH IMPACT ACRYLIC <br />LENS <br />24 <br />3/4"C, 8#12 & 1#12 GND <br />TO 2V32-1BE16-3/la,3b,5c,7a <br />VIA LCP-2V32-1BE16-2 PANEL <br />CONTROLLED BY SWITCH "PSW2 & PSWY <br />�1 <br />FIXTURE <br />GROUND <br />( POINT <br />�— LIGHT FIXTURE <br />BOUNDARY <br />rJ , <br />DETAIL NOTES: <br />REMOVE FIXTURE BALLAST IF PRESENT AND WIRE INCOMING BRANCH CIRCUIT <br />HOT AND NEUTRAL DIRECTLY TO FIXTURE DISCONNECT. MALE SIDE (ORANGE <br />END) OF DISCONNECT SHALL BE ON THE INCOMING BRANCH CIRCUIT AND <br />FEMALE ON THE FIXTURE WIRING (NO SUBSTITUTIONS.) <br />PROVIDE IN —LINE FUSE HOLDER WITH FUSE AND WIRE AS SHOWN TO <br />DISCONNECT AND TOMBSTONE WIRING. <br />WIRE NEUTRAL TOMBSTONE TO FIXTURE DISCONNECT. <br />4� WIRE GROUND TO FIXTURE GROUND SCREW/POINT. <br />INSTALL LED TUBES IN TOMBSTONES (NO SUBSTITUTIONS.) ORIENT TUBES SO <br />HOT END OF TUBE IS INSERTED IN THE HOT TOMBSTONE AND NEUTRAL IN <br />THE NEUTRAL TOMBSTONE. (QTY. 2 PER FIXTURE) <br />© INSTALL FACTORY SUPPLIED LABEL ON THE EXTERIOR FACE OF THE LIGHT <br />FIXTURE NEAR THE HOT END TOMBSTONE, LABEL MUST BE VISIBLE WITHOUT <br />REMOVAL OF TUBES OR FIXTURE PARTS. <br />1/2"C, 3#14 <br />TO LIGHTING CONTROL PANEL <br />LCP-2V32-1 BET 6-2 <br />46/48 SECTION S & I B DECK PLAN <br />SCALE: 1:50 <br />LIGHTING LED TUBE INSTALLATIONARIE SC <br />SCALE: NTS swwnsq'NGr�r��� <br />�SSION <br />3 <br />17 <br />REV REVISI❑N DESCRIPTI❑N AUTH❑RIZATIONS <br />0 RRO — 767 Rate Increase AFT SI — IFC (EVE-18-30055-601) VIB <br />1 RRO — 767 Rate Increase AFT SI — Issue For Permit (EVE-18-30055-601) DESIGNER; <br />CHECKER, SMS <br />APPROVALt SMS <br />LEGEND <br />® JUNCTION BOX, FIELD SIZED OR AS NOTED <br />�] SPECIAL PANEL AS NOTED <br />® PANELBOARD, 480V, 30, 3W, PANELBOARD <br />® PANELBOARD, 480Y/277V, 30, 4W, PANELBOARD <br />IT] TRANSFORMER, SIZE AND TYPE AS NOTED <br />$LV LOW —VOLTAGE LIGHT SWITCH <br />Di FUSED DISCONNECT <br />C- D LIGHTING CIRCUIT REGION <br />GENERAL NOTES <br />1. FOR FIXTURE TYPES SEE DRAWING 40-031—EOb. <br />2. 1ST DECK IS ZONE 1. 2ND DECK IS ZONE 2. <br />3. ALL CONDUCTORS, JUNCTION BOXES AND OUTLET BOXES SHALL BE <br />CROUSE—HINDS CAST METAL BOXES. <br />4. UNLESS OTHERWISE NOTED ALL WIRING SHALL BE 1/2"C, 2#12 & 1#12 <br />GND. <br />5. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE <br />THHN/THWN, UNLESS OTHERWISE NOTED. <br />6. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE <br />APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER <br />CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND <br />CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). <br />COLOR CODE AS FOLLOWS: <br />120 208V 277 480V <br />"A" 0 (LEFT BUS IN PANEL) BLACK BROWN <br />"B" 0 (CENTER BUS IN PANEL) RED ORANGE <br />"C" 4 (RIGHT BUS IN PANEL) BLUE YELLOW <br />NEUTRAL WHITE GREY <br />EQUIPMENT GROUND GREEN GREEN <br />ISOLATED GROUNDYELLOW GRN/YEL* GRN/YEL* <br />*GREEN WITH YELLOW TRACER <br />7. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH <br />CIRCUIT IDENTIFICATION. <br />8. POST NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. <br />9. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES AS DETAILED. <br />REFERENCE DRAWINGS <br />CONSTRUCTION NOTES <br />L PROVIDE LIGHTS N PLASTICS SENTRY SERIES #VT4S <br />PRE —WIRED WITH TOMBSTONES, AND NO BALLAST. REPLACE <br />EXISTING LUMINAIRES THAT ARE BROKEN AT LOCATIONS <br />SHOWN. SEE DETAIL 1 THIS SHEET, <br />EXISTING LOW —VOLTAGE LIGHT SWITCHES. <br />USE EXISTING BRANCH CIRCUIT. <br />4 EXISTING 2—LAMP VAPOR—TITE 48" FLUORESCENT METALUX <br />1 #VT2-232DR-12OV—GL. RETROFIT WITH LED LAMPS, SEE <br />DETAIL 1 THIS SHEET. 00. <br />5 PROVIDE RIGID STEEL CONDUIT AND CROUSE HINDS EYS <br />SEAL —OFFS BETWEEN EXPLOSION —PROOF FIXTURES AND <br />NORMAL FIXTURES. <br />LIGHTING SYSTEM <br />46/48 SECTION S 8& I B DECK PLAN AND ELEVATION <br />BUILDING 40-32, COL E16-17 <br />013RPH <br />www. brph.com Copyright® 2019 <br />Architects Engineers, Inc. <br />19020 33rd Ave W, Suite 530 State of Washington <br />Lynnwood, Washington, 98036 Certificate of Authorize6on <br />Lynnwood, <br />W Architecture No. 603235512 <br />Engineering No. 3137 <br />IDM <br />PRODUCT <br />TYPE: <br />DISCIPLINE: <br />DATE <br />PLOTTED; <br />STATUS: <br />STATUS <br />DATE: <br />DESIGN <br />OPTION ID; <br />REVISIONS <br />SCALE <br />ALL DIMENSIDNS IN INCHES <br />ORG, NO, <br />CONCURRENCE <br />DATE <br />FINISH <br />COLOR OR PROTECTIVE <br />SECTION <br />13 <br />SHT SIZE <br />REV <br />REV <br />DATE <br />MODEL <br />0 <br />08/16/19 <br />EXCEPT AS NOTED <br />TOLERANCES MACHINE <br />DECIMAL FINISH <br />X =± <br />M =± 7 <br />,xxx=± <br />ANGULAR =± SEE TDM <br />1 <br />08/27/19 <br />ICJ <br />BCAG EVERETT DIVISI❑N <br />NAME <br />DATE <br />DESIGNED <br />VTB <br />08/27/19 <br />FLOOR MOUNTED EQUIPMENT <br />BODY SECTIONS 46/48 <br />DETAILED <br />SMS <br />08/27/19 <br />FLOOR AREA <br />APPROX WT <br />CHECKED <br />SMS <br />08/27/19 <br />SEE SHT 1 <br />SEE SHT 1 <br />APPROVED <br />PROD <br />CHG NO <br />USED ON <br />WORK ORDER BA# EVE-18-30055-601 <br />APPROVED <br />FME1 40T0000-8000 <br />DWG NO. SHT No, E020F <br />DRAWING NO <br />SHEET <br />REV <br />NO <br />NAME; <br />EVERETT FACILITIES SERVER <br />LAST PROD DRAWING CHANGE <br />NOR <br />MODEL <br />NAME <br />fine 140t0000-8000 e02 <br />O <br />Cal <br />Q <br />O <br />O <br />O <br />I— <br />I <br />Q <br />to <br />cn <br />U <br />0 <br />w <br />Q <br />w <br />Cn <br />z <br />Q <br />ry <br />w <br />cn <br />cn <br />U <br />w <br />Q <br />w <br />cD <br />w <br />w <br />O <br />U <br />Q <br />Q <br />U <br />m <br />C-D <br />z_ <br />U <br />0 <br />w <br />Q <br />W <br />U <br />CD <br />z_ <br />Q <br />