STRUCTURAL ABBREVIATIONS <br />GENERAL NOTES <br />1. <br />THE STRUCTURAL DRAWINGS REPRESENT THE DESIGN OF THE PRIMARY STRUCTURE <br />AND <br />FIN <br />- FINISH(ED) <br />PAF <br />- POWDER ACTUATED FASTENER <br />BASED ON PRESCRIBED LOADS, (SEE "DESIGN CRITERIA" SECTION), IMPOSED ON THE <br />"BUILDING <br />@ <br />- AT <br />FLG <br />- FLANGE <br />PAR <br />- PARALLEL/PARAPET <br />STRUCTURE PER THE BUILDING CODE AS SPECIFIED IN THE CODE" <br />°, DEG <br />- DEGREE <br />FLR <br />- FLOOR <br />PCC <br />- PRECAST CONCRETE <br />SECTION. THE PRIMARY STRUCTURE OF THE BUILDING IS DEFINED AS THE <br />0, DIA <br />- DIAMETER <br />FO xxx <br />- FACE OF xxx <br />PEMB <br />- PRE-ENGINEERED METAL BUILDING <br />FOUNDATIONS, BEARING WALLS, SHEAR WALLS, COLUMNS, BEAMS, SLABS, FLOOR <br />(E), EXIST <br />- EXISTING <br />FOC <br />- FACE OF CONCRETE <br />PEN <br />- PENETRATE/PENETRATION <br />FRAMING AND LATERAL FORCE RESISTING ELEMENTS REQUIRED TO MAINTAIN THE <br />NO <br />- NUMBER <br />FOF <br />- FACE OF FINISH <br />PIL <br />- PILASTER <br />STABILITY OF THE COMPLETED STRUCTURE AS A WHOLE. <br />LB <br />- POUND <br />FOS <br />- FACE OF STEEL <br />PJP <br />- PARTIAL JOINT PENETRATION WELD <br />2. <br />ALL CONSTRUCTION MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE <br />FP <br />- FIMEPROOF(ING)/FIRE PROTECTION <br />PL <br />- PLATE <br />REQUIREMENTS OF THE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND <br />AB <br />- ANCHOR BOLT <br />FRT <br />- FIRE RETARDANT TREATED <br />PLCS <br />- PLACES <br />REGULATIONS OF THE BUILDING CODE AS DEFINED IN THE "BUILDING CODE" SECTION. <br />ABV <br />- ABOVE <br />FS <br />- FAR SIDE <br />PNL <br />- PANEL <br />ADDL <br />ADH <br />- ADDITIONAL <br />- ADHESIVE <br />FT <br />FTG <br />- FOOT, FEET <br />- FOOTING <br />PRCST <br />PREFAB <br />- PRECAST <br />- PREFABRICATED <br />3. <br />THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE, THEY DO NOT <br />ADJ <br />- ADJACENT <br />PSF <br />- POUNDS PER SQUARE FOOT <br />INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL <br />AFS <br />- ABOVE FINISHED SLAB <br />GA <br />- GAGE/GAUGE <br />PSI <br />- POUNDS PER SQUARE INCH <br />MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH <br />ALT <br />- ALTERNATE <br />GALV <br />- GALVANIZED <br />PT <br />- POST TENSIONED/PRESSURE TREATED <br />MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS <br />ALUM <br />- ALUMINUM <br />GEN <br />- GENERAL <br />PUR <br />- PURLIN <br />DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE <br />STRUCTURAL_ ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. <br />APPROX <br />- APPROXIMATE <br />GLU LAM <br />- GLUE LAMINATED TIMBER <br />AR <br />- AS REQUIRED <br />GR <br />- GRADE <br />R <br />- RADIUS <br />4. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY BRACING AS REQUIRED <br />ARCH <br />- ARCHITECTURAL <br />GR BM <br />- GRADE BEAM <br />RC <br />- REINFORCED CONCRETE <br />FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL MEMBERS ARE IN <br />ASPH <br />- ASPHALT <br />GYP BD <br />- GYPSUM BOARD <br />RD <br />- ROOF DRAIN <br />PLACE AND FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE <br />ASSY <br />- ASSEMBLY <br />REF <br />- REFERENCE <br />PLANS. <br />H <br />- HIGH <br />REINF <br />- REINFORCING <br />B PL <br />- BASE PLATE <br />HDR <br />- HEADER <br />READ <br />- REQUIRED <br />5. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE <br />BLDG <br />- BUILDING <br />HGR <br />- HANGER <br />RO <br />- ROUGH OPENING <br />MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM <br />BLKG <br />- BLOCKING <br />HLDN <br />- HOLDDOWN <br />RST <br />- REINFORCING STEEL <br />THE WORK. <br />BLW <br />- BELOW <br />HORIZ <br />- HORIZONTAL <br />BM(S) <br />- BEAM(S) <br />HSS <br />- HOLLOW STRUCTURAL SECTION <br />SC <br />- SLIP CRITICAL <br />6. <br />CONSTRUCTION TOLERANCES SHALL CONFORM TO THE BUILDING STANDARDS <br />BO xxx <br />- BOTTOM OF xxx <br />HT <br />- HEIGHT <br />SCHED <br />- SCHEDULE <br />„ <br />SPECIFIED IN THE BUILDING CODE SECTION. <br />BOT <br />- BOTTOM <br />HVAC <br />- HEATING, VENTILATING AND <br />SECT <br />- SECTION <br />BRB <br />- BUCKLING RESTRAINED BRACE <br />AIR CONDITIONING <br />SLRS <br />- SEISMIC LOAD RESISTING SYSTEM <br />7. <br />DO NOT SCALE THE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS <br />BRG <br />BS <br />- BEARING <br />- BOTH SIDES <br />ID <br />- INSIDE DIAMETER <br />SHT <br />SHTHG <br />- SHEET <br />- SHEATHING <br />PRIOR TO CONSTRUCTION. THE FOR SHALL BE NOTIFIED OF ANY DISCREPANCIES OR <br />BTWN <br />- BETWEEN <br />IF <br />- INSIDE FACE <br />SIM <br />- SIMILAR <br />INCONSISTENCIES IN A PROMPT MANNER. <br />IJ <br />- ISOLATION JOINT <br />SJ <br />- SAWCUT CONTRACTION JOINT <br />C <br />- CHANNEL <br />IN <br />- INCHES <br />SL <br />- SLOPE <br />8. <br />IF ANY ERRORS OR OMISSIONS APPEAR TO EXIST IN THESE DRAWINGS, <br />CANT <br />- CANTILEVER <br />INFO <br />- INFORMATION <br />SMS <br />- SHEET METAL SCREW <br />OR OTHER CONTRACT DOCUMENTS; THE CONTRACTOR SHALL NOTIFY <br />SPECIFICATIONS, , <br />CDF <br />- CONTROLLED DENSITY FILL <br />INSUL <br />- INSULATE/INSULATION <br />SPEC <br />- SPECIFICATION <br />THE STRUCTURAL ENGINEER OR ARCHITECT IN WRITING OF SUCH OMISSION OR ERROR <br />CEM PLAS <br />- CEMENT PLASTER <br />INT <br />- INTERIOR <br />SPCS <br />- SPACES <br />BEFORE PROCEEDING WITH THE WORK. <br />CIP <br />CJ <br />- CAST -IN -PLACE <br />- CONSTRUCTION JOINT/CONTROL JOINT <br />JST <br />- JOIST <br />SQ <br />SSH <br />- SQUARE <br />- SHORT SLOTTED HOLE <br />9. <br />NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL <br />CJP <br />- COMPLETE JOINT PENETRATION WELD <br />JT <br />- JOINT <br />SST <br />- STAINLESS STEEL <br />DETAILS. WHERE NOTES AND DETAILS ON DRAWINGS AND THESE GENERAL NOTES <br />STAG <br />- STAGGERED <br />AND TYPICAL DETAILS ARE IN CONFLICT WITH THE PROJECT SPECIFICATIONS, THE <br />CL <br />CLR <br />- CENTER .LINE <br />- CLEAM(ANCE) <br />KIP <br />- KIP (1,000 POUNDS) <br />STD <br />- STANDARD <br />MOST STRINGENT SHALL APPLY. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE <br />CMU <br />- CONCRETE MASONRY UNIT <br />KSI <br />- KIPS PER SQUARE INCH <br />S CIF <br />- STIFFENER <br />CONSTRUCTED AS SHOWN FOR SIMILAR WORK, SUBJECT TO REVIEW BY THE <br />COL <br />- COLUMN <br />KWY <br />- KEYWAY <br />STIR <br />- STIRRUP <br />FOR AND STRUCTURAL ENGINEER. <br />CONC <br />- CONCRETE <br />STL <br />STL JST <br />- STEEL <br />- STEEL JOIST <br />10. <br />MANUFACTURED MATERIALS SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR <br />CONN <br />- CONNECT(ION) <br />L <br />- ANGLE/LENGTH <br />SLRS <br />- SEISMIC LOAD RESISTING SYSTEM <br />TO THEIR USE. ALL REQUIREMENTS OF THOSE APPROVALS SHALL BE FOLLOWED. <br />CONSTR <br />- CONSTRUCTION <br />LBR <br />- LUMBER <br />STRUCT <br />- STRUCTURAL <br />CONT <br />- CONTINUOUS <br />LLH <br />- LONG LEG HORIZONTAL <br />SYMM <br />- SYMMETRICAL <br />11. <br />THE CONTRACTOR SHALL COORDINATE THE STRUCTURAL DRAWINGS WITH DRAWINGS <br />CONTR <br />- CONTRACTOR <br />LLV <br />- LONG LEG VERTICAL <br />FROM ALL OTHER DISCIPLINES, INCLUDING BUT LIMITED TO ARCHITECTURAL, CIVIL, <br />COORD <br />- COORDINATE <br />LOC <br />- LOCATION <br />TB <br />- THROUGH BOLT <br />MECHANICAL, AND ELECTRICAL. <br />CSK <br />- COUNTER SUNK <br />LONG <br />- LONGITUDINAL <br />CTR <br />- CENTER(ED) <br />LSH <br />- LONG SLOTTED HOLE <br />TBC <br />TBM <br />- THREADED BAR COUPLER <br />- TO BE REMOVED <br />12. <br />SEE MECHANICAL, PLUMBING, ELECTRICAL AND OTHER SPECIALTY DRAWINGS AND <br />/ LONG SIDE HORIZONTAL <br />TD <br />- TRENCH DRAIN <br />PROJECT SPECIFICATIONS FOR THE FOLLOWING: <br />D <br />- DEPTH/DEEP <br />LSV <br />- LONG SIDE VERTICAL <br />THK <br />- THICK(NESS) <br />A. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL_, ROOF AND FLOOR <br />DC <br />- DEMAND CRITICAL <br />LT <br />- LIGHT <br />TO <br />- TOP OF <br />OPENINGS, ETC., NOT SHOWN OR NOTED. <br />DBL <br />- DOUBLE <br />LWC <br />- LIGHTWEIGHT CONCRETE <br />xxx <br />TOC <br />xxx <br />- TOP OF CONCRETE <br />B. ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS. <br />DEG <br />- DEGREE <br />TOF <br />- TOP OF FOOTING <br />C. ANCHORAGE AND BRACING FOR ELECTRICAL, MECHANICAL OR PLUMBING <br />DEMO <br />- DEMOLITION <br />MAX <br />- MAXIMUM <br />TOGB <br />- TOP OF GRADE BEAM <br />EQUIPMENT TO THE STRUCTURE. <br />DET <br />- DETAIL <br />MB <br />- MACHINE BOLT <br />TOS <br />- TOP OF STEEL_ <br />D. ANCHOR BOLTS FOR MOTOR MOUNTS. <br />DIA <br />- DIAMETER <br />MBR <br />- MEMBER <br />TOSL <br />- TOP OF SLAB <br />E. SIZE, WEIGHT AND LOCATION OF MACHINES AND EQUIPMENT BASES. <br />DIAL <br />- DIAGONAL DIAGRAM <br />/ <br />MECH <br />- MECHANICAL <br />TOW <br />- TOP OF WALL <br />DIM <br />- DIMENSION <br />MEZZ <br />- MEZZANINE <br />TRANSV <br />- TRANSVERSE <br />11. <br />FRAMING MEMBERS WHICH ARE NOT DIMENSIONED SHALL BE EQUALLY SPACED <br />DIM <br />- DIRECTION <br />MFR <br />- MANUFACTURE(R/D) <br />TRTD <br />- TREATED <br />BETWEEN DIMENSIONED POINT OF MEMBERS. <br />DIST <br />- DISTANCE <br />MFR REC <br />- MANUFACTURER'S RECOMMENDATIONS <br />CAL <br />DN <br />- DOWN <br />MH <br />- MANHOLE <br />�C <br />- TENSION/COMPRESSION CORD <br />12. <br />OPENINGS, POCKETS, ETC. SHALL NOT BE PLACED IN STRUCTURAL MEMBERS UNLESS <br />DWG <br />- DRAWING <br />MID <br />- MIDDLE <br />SPECIFICAL LY DETAILED ON THE STRUCT URAL DRAWINGS. <br />DWL <br />- DOWEL <br />MIN <br />- MINIMUM <br />T&B <br />- TOP AND BOTTOM <br />MISC <br />- MISCELLANEOUS <br />T&G <br />- TONGUE AND GROOVE <br />13, <br />MATERIALS SPECIFICATIONS ARE ASTM LATEST EDITION. <br />EA <br />EF <br />- EACH <br />- EACH FACE <br />NA <br />- NOT APPLICABLE <br />UON <br />- UNLESS OTHERWISE NOTED <br />EJ <br />- EXPANSION JOINT <br />NIC <br />- NOT IN CONTRACT <br />VAR <br />- VARIATION/VARIES <br />BUILDING CODE <br />EL <br />- ELEVATION <br />NIP <br />- NOT IN PERMIT <br />ELEC <br />- ELECTRICAL <br />NORM <br />- NORMAL <br />VIF <br />- VERIFY IN FIELD <br />1. <br />ALL CONSTRUCTION, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE <br />ELEV <br />- ELEVATOR <br />NO <br />- NUMBER <br />REQUIREMENTS OF THESE DRAWINGS, SPECIFICATIONS, AND THE CODES, RULES AND <br />EMBED <br />- EMBEDMENT EMBEDDED <br />NS <br />- NEAR SIDE <br />VRFY <br />- VERIFY <br />REGULATIONS OF THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION, AS <br />FOR <br />- ENGINEER OF RECORD <br />NTS <br />- NOT TO SCALE <br />VEMT <br />- VERTICAL <br />ADOPTED AND AMENDED BY THE CITY OF EVERETT, HEREINAFTER REFERRED TO AS <br />EOS <br />- EDGE OF SLAB <br />W <br />- WIDE/WIDTH <br />THE BUILDING CODE. <br />EQ <br />- EQUAL <br />0/ <br />- OVER <br />WD <br />- WOOD <br />EQL SP <br />- EQUALLY SPACED <br />OC <br />- ON CENTER <br />2. <br />WHERE NOTED IN THE STRUCTURAL NOTES, CONSTRUCTION, MATERIALS, AND <br />EQUIP <br />- EQUIPMENT <br />OD <br />- OUTSIDE DIAMETER <br />WF <br />- WIDE FLANGE <br />WORKMANSHIP SHALL ALSO CONFORM TO THE FOLLOWING STANDARDS. WHERE THESE <br />ES <br />- EACH SIDE <br />OF <br />- OUTSIDE FACE <br />WHS <br />- WELDED HEADED STUDS <br />STANDARDS CONFLICT WITH THE BUILDING CODE, THE CODE SHALL GOVERN. <br />ESCAL <br />- ESCALATOR � <br />OFS <br />- OUTSIDE FACE OF STUDS <br />WO <br />- WHERE OCCURS <br />EW <br />- EACH WAY <br />OPH <br />- OPPOSITE HAND <br />WP <br />- WATERPROOFING/WORK POINT <br />GENERAL <br />EXIST <br />- EXISTING <br />OPNG <br />- OPENING <br />WPM <br />- WATERPROOF MEMBRANE <br />EXP <br />- EXPANSION <br />OPP <br />- OPPOSITE <br />WT <br />- WEIGHT <br />ASCE "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" <br />EXT <br />- EXTERIOR <br />OVS <br />- OVERSIZED (HOLES) <br />W <br />- WELDED WIRE FABRIC <br />AMERICAN SOCIETY OF CIVIL ENGINEERS <br />W/ <br />- WITH <br />ASCE/SET 7 - 2010 EDITION <br />W/0 <br />- WITHOUT <br />AWS "STANDARD SYMBOLS FOR WELDING, BRAZING, AND NONDESTRUCTIVE <br />XFMR <br />- TRANSFORMER <br />EXAMINATION" <br />AMERICAN WELDING SOCIETY <br />YD <br />- YARD <br />AWS A2.4 - 2012 EDITION <br />SYM REVISION BY APPROVED DATE SYM <br />ORIG ACTIVATE STALL 113/777X Cl REFURB 22999285/W6214003 CEI I EO 04.08.19 <br />f �a�/�'�[�ll <br />BY I APPROVED I DATE <br />13 <br />ACCEPTABILITY CEI <br />THIS DESIGN AND/OR <br />CHECKED <br />SPECIFICATION IS APPROVED <br />R. REEVES <br />ENGINEER <br />APPROVED BY <br />DEPT. <br />DATE <br />K. WANG <br />CHECKED <br />E. OJALA <br />BUILDING CODE <br />(CONT.) <br />HOT ROLLED STEEL <br />AISC <br />"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />ANSI/AISC360 - 2010 EDITION <br />AISC <br />"SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS" <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />ANSI/AISC341 - 2010 EDITION <br />AISC <br />"CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />AISC303 - 2010 EDITION <br />AWS <br />"STRUCTURAL STEEL WELDING CODE - STEEL" <br />AMERICAN WELDING SOCIETY <br />AWS D1.1 - 2010 EDITION <br />AWS <br />"STRUCTURAL STEEL WELDING CODE - SEISMIC SUPPLEMENT" <br />AMERICAN WELDING SOCIETY <br />AWS D1.8 - 2009 EDITION <br />RCSC <br />"SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 <br />BOLTS" <br />RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS <br />DECEMBER 31, 2009 <br />CONCRETE <br />ACI <br />"BUILDING <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" <br />AMERICAN <br />CONCRETE INSTITUTE <br />AC131 8 - <br />2014 EDITION <br />ACI <br />"SPECIFICATIONS <br />FOR STRUCTURAL CONCRETE" <br />AMERICAN <br />CONCRETE INSTITUTE <br />AC1301 - <br />2011 EDITION <br />ACI <br />"DETAILS AND <br />DETAILING OF CONCRETE REINFORCEMENT" <br />AMERICAN <br />CONCRETE INSTITUTE <br />AC1315 - <br />1999 EDITION <br />ACI-117 <br />"STANDARD <br />SPECIFICATIONS FOR TOLERANCES FOR CONCRETE <br />CONSTRUCTION <br />AND MATERIALS" <br />AMERICAN <br />CONCRETE INSTITUTE <br />ACI 117 - <br />2006 <br />DESIGN CRITERIA <br />STORAGE SHED: <br />PRE-ENGINEERED METAL BUILDING. SEE SHOP DRAWING PACKAGE FOR DESIGN. <br />STORAGE SHED FOUNDATION: <br />1. LIVE LOAD CRITERIA 250 PSF HEAVY STORAGE/ <br />VEHICULAR DRIVEWAY <br />2. WIND DESIGN CRITERIA <br />3-SECOND GUST WIND SPEED, V = <br />110 MPH <br />EXPOSURE FACTOR <br />C <br />IMPORTANCE FACTOR 1 = <br />1.00 <br />INTERNAL PRESSURE COEFFICIENT GCpi <br />= 0.18 <br />3. SEISMIC DESIGN CRITERIA <br />SEISMIC USE GROUP <br />II <br />SITE CLASS <br />D <br />IMPORTANCE FACTOR 1 = <br />1.00 <br />SS = <br />1.445 <br />S1 = <br />0.561 <br />SIDS = <br />0.963 <br />SD1 = <br />0.561 <br />SEISMIC DESIGN CATEGORY <br />D <br />LATITUDE <br />47°55'08" N <br />LONGITUDE <br />122®16'27" W <br />4. FOUNDATION DESIGN CRITERIA <br />*FOUNDATION TYPE: FOOTINGS AND RETAINING <br />WALLS <br />*ALLOWABLE SOIL BEARING PRESSURE = 1500 <br />PSF <br />DEMOLITION <br />1. ALL DEMOLITION SHALL BE CARRIED ON IN SUCH A MANNER AS NOT TO DAMAGE <br />EXISTING ELEMENTS WHICH ARE TO REMAIN A PART OF THE FINISHED STRUCTURE. <br />2. EXISTING ELEMENTS SHALL BE PROTECTED TO THE FULLEST EXTENT POSSIBLE TO <br />REDUCE SUCH DAMAGE_ TO A MINIMUM. <br />3. ALL ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN AND WHICH ARE DAMAGED <br />DURING DEMOLITION WORK SHALL BE REPLACED AT NO ADDED COST. <br />ISSUED FOR PERMIT <br />04/08/2019 <br />CIE SUBTITLE CURRENT REVISION ISYMBOL DATE <br />04.08.19 STRUCTURALI iONS AND NOTES 22000285/W6214_0 3L 0 R I C 04.08.19 <br />04.08.19 SHEET <br />04.08.19 TITLE ACTIVATE STALL 113/777X Cl REFURB S2A-1 <br />04.08.19_ BUILDING 45-005 <br />JOB NO. COMP NO. <br />22000285/W6214003 <br />STRUCTURAL MASTER EVERETT, WA DWG NO. 45-005-S2A-1 <br />