CONCRETE <br />1. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE <br />BUILDING CODE AND ACI SPECIFICATIONS. <br />2. CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS <br />IN ADDITION TO THE REQUIREMENTS IN THESE DRAWINGS. WHERE THE <br />SPECIFICATIONS APPEAR TO CONFLICT WITH THE REQUIREMENTS IN THESE DRAWINGS, <br />THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT/STRUCTURAL <br />ENGINEER BEFORE PROCEEDING WITH WORK. <br />3. CONCRETE SHALL CONFORM TO THE STRENGTH, WATER -CEMENT RATIO, EXPOSURE <br />CLASS, MAXIMUM UNIT WEIGHT AND CEMENT TYPE SPECIFIED IN THE SCHEDULE <br />BELOW. CONCRETE STRENGTHS SHALL BE VERIFIED BY 26-DAY CYLINDER TESTS. <br />ELEMENT Vc MAX W/C PATIO EXPOSURE CLASS MAX UNIT WEIGHT CEMENT TYPE <br />WORKSHED 4,500 0.45 F2 145 1 OR II <br />FOOTING <br />A. *TOTAL WATER IN CONCRETE FOR SLABS ON GRADE SHALL NOT EXCEED 265 LBS <br />PER CUBIC YARD. <br />B. EXPOSURE CLASSES ARE FO, SO, PO, CO UNLESS NOTED OTHERWISE IN THE TABLE <br />ABOVE. <br />C. CONCRETE MIXES SHALL COMPLY WITH ACI 316 SECTION 19.3 FOR THE <br />EXPOSURE CLASSES INDICATED THE TABLE ABOVE. FOR CLASSES F1 THROUGH F3, <br />AIR ENTRAINMENT SHALL MEET THE REQUIREMENTS OF ACI-31 8 TABLE <br />19.3.3.1 <br />D. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 OF THE TYPE SPECIFIED <br />IN THE TABLE ABOVE. <br />E. COARSE AND FINE AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL <br />CONFORM TO ASTM C-33. <br />F. AGGREGATE FOR LIGHTWEIGHT CONCRETE SHALL CONFORM TO ASTM C-330. <br />G. WATER SHALL BE CLEAR AND SHALL CONFORM TO ASTM C-94. <br />H. CONCRETE MIXING OPERATIONS SHALL CONFORM TO ASTM C-94. <br />I. ALL EXTERIOR CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE <br />AIR -ENTRAINED WITH AN AIR CONTENT CONFORMING TO ACI 316 TABLE 19.3.3.1. <br />AIR ENTRAINMENT SHALL CONFORM TO ASTM C-260. <br />4. CONTRACTOR MAY USE AN ADMIXTURE SYSTEM TO PRODUCE FLOWABLE CONCRETE. <br />MAXIMUM SLUMP SHALL NOT EXCEED S INCHES MEASURED AT THE PUMP. THE <br />WATER/CEMENTIOUS MATERIAL RATIO OF THE APPROVED MIXES SHALL BE MAINTAINED <br />OR LOWERED WHEN FLOWABLE CONCRETE IS USED. A REPRESENTATIVE OF THE <br />ADMIXTURE SYSTEM SHALL ASSIST IN DETERMINING PROPORTIONS FOR FLOWABLE <br />CONCRETE AND SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER AND ARCHITECT <br />PRIOR TO EMPLOYING THIS PROCEDURE. SEE PROJECT SPECIFICATIONS FOR <br />ADDITIONAL REQUIREMENTS. <br />5. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR <br />REINFORCEMENT PLACED IN CAST -IN -PLACE CONCRETE: <br />A. CONCRETE CAST AGAINST AND PERMANENTLY <br />EXPOSED TO EARTH: 3" <br />B. CONCRETE EXPOSED TO EARTH OR WEATHER: <br />#6 THROUGH #16 BARS <br />2" <br />#5 BAR, W31 OR D31 WIRE, AND SMALLER <br />1 1 /2" <br />C. CONCRETE NOT EXPOSED TO WEATHER OR IN <br />CONTACT WITH GROUND: <br />BEAMS, COLUMNS: <br />1 1 /2" <br />SLABS, WALLS, JOISTS: <br />#14 AND #16 BARS <br />1 1/2" <br />#11 BARS AND SMALLER <br />3/4" <br />SHELLS, FOLDED PLATE MEMBERS: <br />#6 BAR AND LARGER <br />3/4" <br />#5 BAR, W31 OR D31 WIRE, AND SMALLER <br />1/2" <br />6. BASE PLATE GROUT SHALL BE NON -SHRINK TYPE CONFORMING TO <br />ASTM C-1107 <br />WITH A MINIMUM COMPRESSIVE STRENGTH AT 26 DAYS OF 7000 PSI. <br />7. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI REQUIREMENTS <br />AND THE <br />CONTRACT DOCUMENTS. SANDBLAST ALL CONCRETE SURFACES AGAINST WHICH <br />CONCRETE IS TO BE PLACED, UON. <br />6. FORMS FOR CONCRETE SHALL BE LAID OUT AND CONSTRUCTED TO <br />PROVIDE THE <br />SPECIFIED CAMBERS SHOWN ON THE DRAWINGS. <br />9. PROJECTING CORNERS OR BEAMS, WALLS, COLUMNS, ETC., SHALL BE FORMED WITH <br />A 3/4 INCH CHAMFER, UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL <br />DRAWINGS <br />10, PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN CONCRETE BEFORE <br />PLACING. REINFORCING SHALL NOT BE CUT. CORING OF CONCRETE IS NOT <br />PERMITTED EXCEPT AS INDICATED, <br />11. CONCRETE FOR STORAGE SHED FOUNDAI ION SHALL CONTAIN A WATERPROOFING <br />ADMIXTURE (HYCRETE OR EQUAL) AND WATERSTOPS SHALL BE USED AT ALL JOINTS. <br />REINFORCING STEEL <br />1. REINFORCING STEEL SHALL BE DETAILED, INCLUDING HOOKS AND BENDS, AND <br />PLACED IN ACCORDANCE WITH ACI 315 AND ACI 316. <br />2. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 OR A-706, GRADE 60. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-165. <br />4. THE FOLLOWING SHALL BE USED IN CONCRETE BUILDING STRUCTURES <br />A. THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS SHALL NOT EXCEED THE <br />SPECIFIED YIELD STRENGTH BY MORE THAN 16,000 PSI. RETESTS SHALL NOT <br />EXCEED THIS VALUE BY MORE THAN AN ADDITIONAL 3000 PSI. <br />B. THE RATIO OF THE ACTUAL ULTIMATE TENSILE STRESS TO THE ACTUAL TENSILE <br />YIELD STRENGTH SHALL NOT BE LESS THAN 1.25. <br />5. ALL REINFORCING BAR BENDS SHALL BE MADE COLD. BARS SHALL NOT BE RE -BENT. <br />6. REINFORCING SPLICES SHALL. BE MADE AS INDICATED ON THE DRAWINGS. <br />7. WELDED WIPE FABRIC SHALL BE LAPPED AT SPLICES SUCH THAT A MINIMUM OF <br />THREE WIRES PARALLEL TO THE SPLICE ARE OVERLAPPED. SPLICES SHALL OVERLAP <br />A MINIMUM OF 6 INCHES. <br />6. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, <br />SIZE AND SPACING AS THE VERTICAL REINFORCING, RESPECTIVELY, UNLESS <br />OTHERWISE NOTED. <br />9. PROVIDE #4 x 2'-0" DIAGONAL BAR AT ALL REENTRANT CORNERS OF CONCRETE <br />SLABS ON GRADE AND SLABS ON METAL DECK. <br />10. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT <br />UNLESS SPECIFICALLY SO DETAILED AND REVIEWED BY THE STRUCTURAL ENGINEER. <br />11. WELDING OF REINFORCEMENT SHALL CONFORM TO THE 2005 EDITION OF AWS D1.4 <br />66STRUCTURAL WELDING CODE - REINFORCING STEEL19. WELDED CONNECTIONS NOT <br />SPECIFIED ON THE PLANS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE <br />STRUCTURAL ENGINEER. <br />12. REINFORCING TO BE WELDED SHALL CONFORM TO ASTM A-706. BARS CONFORMING <br />TO ASTM A-615 MAY BE SUBSTITUTED PROVIDED THAT DOCUMENTAT ION IS SUBMITTED <br />TO THE STRUCTURAL ENGINEER FOR REVIEW SHOWING THAT THE BARS FULLY <br />CONFORM TO THE WELDABILITY REQUIREMENTS OF AWS D1.4. <br />13. REINFORCEMENT SHALL BE SECURELY TIED IN PLACE PRIOR TO THE PLACEMENT OF <br />CONCRETE OR GROUT. CONCRETE REINFORCEMENT OF SHALL BE SECURED IN <br />CONFORMANCE WITH ACI-316 SECTION 7.5. MASONRY REINFORCEMENT SHALL BE <br />SECURED IN CONFORMANCE WITH ACI-350.1 SECTION 3.4. <br />14. REINFORCING STEEL PROJECTING FROM THE CONCRETE OR MASONRY AND <br />CONNECTING DIRECTLY TO STRUCTURAL STEEL WHERE DIMENSIONAL CONTROL IS <br />CRITICAL OR WHERE SPECIFICALLY NOTED ON THE PLAN SHALL BE TREATED AS AN <br />ANCHOR ROD AND SHALL CONFORM TO THE TOLERANCES SPECIFIED IN SECTION 7.5 <br />OF AISC 303-05 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND <br />BRIDGES". <br />FOUNDATIONS <br />1. ALL FOUNDATIONS SHALL BE FOUNDED A MINIMUM OF 16 INCHES BELOW LOWEST <br />ADJACENT FINAL FINISH FLOOR OR GRADE. EXPOSED SOIL SHALL BE INSPECTED <br />FOR COMPLIANCE WITH THE SOILS REPORT BY THE INSPECTION AGENCY <br />REPRESENTATIVE PRIOR TO CONSTRUCTING CONCRETE FORMS AND/OR PLACING <br />REINFORCING STEEL. ANY EXCESS OR NON -COMPLYING MATERIAL AS DETERMINED <br />BY THE INSPECTION AGENCY REPRESENTATIVE SHALL BE REMOVED AND REPLACED <br />AS DIRECTED BY A SOILS ENGINEER. <br />2. FOOTING DEPTHS ARE MINIMUM DIMENSIONS, AND MAY BE CHANGED BY A SOILS <br />ENGINEER IN ORDER TO ACHIEVE THE REQUIREMENTS OF THE APPROVED SOILS <br />REPORT. <br />3. THE CONTRACTOR SHALL, PRIOR TO BEGINNING GRADING AND FOUNDATION <br />EXCAVATION WORK, READ THE SOILS REPORT. IF THE CONTRACTOR, DURING THE <br />COURSE OF SITE WORK, DISCOVERS ANY SOIL CONDITION THAT IS NOT CONSISTENT <br />WITH THE SOILS REPORT, HE SHALL IMMEDIATELY NOTIFY THE EOR. <br />4. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW <br />GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE <br />AND HAVE ATTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL PROVIDE FOR <br />THE DESIGN, PERMITS AND INSTALLATION OF SUCH BRACING. RETAINING WALLS <br />SHALL HAVE ATTAINED FULL DESIGN STRENGTH PRIOR TO BEING BACKFILLED. <br />5. ALL RETAINING WALLS SHALL HAVE FREE DRAINING OR GRAVELY BACKFILL, OR <br />DRAINAGE MAITING, FULL HEIGHT OF WALL. <br />6. ALL WALKWAYS AND OTHER EXTERIOR SLABS ON GRADE MAY NOT BE SHOWN ON <br />THE STRUCTURAL PLANS. USE 4" THICK CONCRETE SLABS WITH 6x6-W1.4xW1.4 <br />WWF MATS, UNLESS SHOWN OTHERWISE. <br />7. CONTRACTOR SHALL PROVIDE FOR DE -WATERING OF EXCAVATIONS FROM SURFACE <br />WATER, GROUND WATER OR SEEPAGE. <br />6. CONTRACTOR SHALL PROVIDE FOR THE DESIGN AND INSTALLATION OF ALL CRIBBING, <br />SHEATHING AND SHORING REQUIRED TO SAFELY RETAIN ALL EARTH BANKS. <br />STRUCTURAL STEEL, MISC. METAL <br />1. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE <br />BUILDING CODE AND RISC STANDARDS USING LOADS AS DEFINED IN AISC-360 <br />SECTION 133-3 "DESIGN FOR STRENGTH USING LOAD AND RESISTANCE FACTOR <br />DESIGN (LRFD)". <br />2. STRUCTURAL STEEL FABRICATION AND ERECTION SHALL CONFORM TO AISC <br />REQUIREMENTS AND THE PROJECT SPECIFICATIONS. <br />3. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION OF ELEMENTS AND <br />CONNECTIONS MARKED 'SLRS' SHALL CONFORM TO AISC-341. <br />4. STRUCTURAL STEEL SHALL CONFORM TO THE <br />FOLLOWING, UNLESS <br />OTHERWISE <br />NOTED <br />ON THE STRUCTURAL DRAWINGS: <br />WIDE FLANGE SHAPES <br />ASTM <br />A992, <br />Fy = <br />50 <br />KSI <br />PLATES AND BARS <br />ASTM <br />A36, <br />Fy = <br />36 <br />KSI <br />CHANNELS AND ANGLES <br />ASTM <br />A36, <br />Fy = <br />36 <br />KSI <br />HOLLOW ROUND SECTIONS <br />ASTM <br />A500-13, <br />Fy = <br />42 <br />KSI <br />HOLLOW RECTANGULAR SECTIONS <br />ASTM <br />A500-13, <br />Fy = <br />46 <br />KSI <br />ROUND PIPE <br />ASTM <br />A53-13, <br />Fy = <br />35 <br />KSI <br />ANCHOR RODS EMBEDDED IN CONCRETE <br />ASTM <br />F1554 GRADE 36 <br />CONNECTION BOLTS <br />A325-N-STD <br />5. HEADED STUD CONNECTORS (WHS) SHALL CONFORM TO AWS D1.1 SECTION 7 AND <br />SHALL BE FABRICATED FROM COLD DRAWN STEEL CONFORMING TO ASTM A-106 WITH <br />A MINIMUM TENSILE STRENGTH OF 65 KSI. STUD WELDING, INSPECTION AND TESTING <br />SHALL CONFORM TO AWS REQUIREMENTS. <br />6. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW <br />AND APPROVAL PRIOR TO THE START OF FABRICATION. <br />7. WELDING SHALL BE PERFORMED IN ACCORDANCE WITH AWS REQUIREMENTS. ALL <br />WELDS SHALL BE PREQUALIFIED IN ACCORDANCE WITH AWS AND AISC STANDARDS. <br />USE E70XX ELECTRODES, UON. <br />6. WELDING OF MEMBERS AND CONNECTIONS MARKED 'SLRS' SHALL BE PERFORMED IN <br />ACCORDANCE WITH AWS D1.6. <br />9. ALL WELDS SHALL BE PERFORMED BY WELDERS CERTIFIED IN THE JURISDICTION <br />HAVING AUTHORITY OVER THIS PORTION OF THE WORK. <br />10. WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH <br />REQUIRED. WELD SIZE SHALL BE AISC MINIMUM, UON. <br />11. BOLTED CONNECTIONS OF MEMBERS MARKED 'SLRS' SHALL BE PRETENSIONED AND <br />SHALL MEET THE REQUIREMENTS FOR A CLASS A FAYING SURFACE. CONNECTIONS <br />AT THESE MEMBERS SHALL BE MADE USING STANDARD HOLES IN ALL PLYS. <br />12. BEAM PENETRATIONS MAY BE CREATED PER THE TYPICAL DETAIL WITHOUT PRIOR <br />APPROVAL OF STRUCTURAL ENGINEER. PENETRATIONS OF ANY SIZE IN ANY OTHER <br />AREA OF THE MEMBER MUST BE REVIEWED AND APPROVED BY THE STRUCTURAL <br />ENGINEER. <br />13. CONNECTIONS SHOWN FIELD WELDED MAY BE FIELD BOLTED AT OPTION OF <br />FABRICATOR. SUBMIT PROPOSED CONDITION TO STRUCTURAL ENGINEER FOR REVIEW <br />PRIOR TO SUBMISSION OF SHOP DRAWINGS AND FABRICATION, <br />14. BEAMS AND GIRDERS SHALL NOT SUPPORT PIPING LARGER THAN 10" DIAMETER <br />WITHOUT THE REVIEW OF THE STRUCTURAL ENGINEER OF RECORD. <br />15. TENSION CONTROL BOLTS MAY BE SUBSTITUTED FOR THE BOLTS SPECIFIED IN THESE <br />PLANS AT THE DISCRETION OF THE CONTRACTOR. ASTM F1652 TC BOLTS MAY BE <br />SUBSTITUTED FOR ASTM A325 BOLTS AND ASTM F2280 TIC BOLTS MAY BE <br />SUBSTITUTED FOR ASTM A490. <br />16. A449, A193 GRADE B7, OR F1554 GRADE 105 THREADED ROD SHALL BE USED <br />WHERE THRU BOLT LENGTH DOES NOT ALLOW FOR STANDARD A325 BOLTS. PROVIDE <br />ASTM A563 NUTS WITH MATCHED WASHERS AT BOTH ENDS. <br />17. USE DOUBLE NUTS OR SINGLE NUT AND PEENED THREADS AT BOLTED CONNECTIONS <br />WITH LONG SLOT HOLES. <br />16. HOLE SIZES IN STEEL MEMBERS CONNECTED TO CONCRETE OR MASONRY SHALL BE <br />1/16" LARGER THAN THE BOLT DIAMETER. THE USE OF LARGER HOLES WOULD <br />REQUIRE THE USE OF WELDED PLATE WASHERS AND WOULD REQUIRE PRIOR <br />APPROVAL BY THE STRUCTURAL ENGINEER, HARDENED OR COMMON PLATE WASHERS <br />ARE REQUIRED BELOW ALL NUTS WHERE OVERSIZED HOLES ARE USED AND SHALL <br />BE SIZED TO COVER THE ENTIRE HOLE. MAXIMUM HOLE SIZES AND MINIMUM <br />WASHER SIZES FOR COLUMN BASE PLATES SHALL BE IN ACCORDANCE WITH TABLE <br />14-2 OF THE AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION. <br />19. WHERE SPECIFIED, GALVANIZED STEEL SHALL CONFORM TO ASTM A123 WITH MINIMUM <br />COATING THICKNESS GRADE 60. VENT HOLES ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL BE INDICATED ON THE SHOP DRAWINGS. <br />20. REPAIR ALL DAMAGE TO GALVANIZED COATINGS BY EITHER THE HOT -STICK OR <br />HIGH -ZINC PAINT METHODS IN ACCORDANCE WITH ASTM A760. <br />STEEL CONT. <br />21. FABRICATOR SHALL REVIEW PROJECT SPECIFICATIONS TO DETERMINE PAINTING <br />AND GALVANIZING REQUIREMENTS. MEMBERS EMBEDDED IN CONCRETE OR TO <br />RECEIVE SPRAY -ON FIREPROOFING SHALL NOT BE PAINTED. DO NOT PAINT <br />AREAS OF PIECES TO BE FIELD WELDED, OR REMOVE PAINT IN FIELD PRIOR TO <br />WELDING. <br />22. CONTRACTOR SHALL COMPLY WITH OSHA REGULATION 29 CFR PART 1926, <br />SUBPART R-STEEL ERECTION, PUBLISHED JANUARY 16, 2001. MISCELLANEOUS <br />PLATES FOR GUYING CABLE ATTACHMENTS, TEMPORARY JOIST BRACING, ETC. <br />SHALL BE ADDED AS REQUIRED. CONTRACTOR SHALL EVALUATE COLUMNS AND <br />PROVIDE ADEQUATE BASE PLATES SHIMS, GUYS, OR TEMPORARY BRACING AS <br />REQUIRED PER SECTION 1926.755. <br />EXISTING CONSTRUCTION <br />1. EXISTING STRUCTURAL DIMENSIONS AND MEMBERS SIZES ARE FOR REFERENCE <br />ONLY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO <br />FABRICATION. THE CONTRACTOR SHALL VERIFY THE ACTUAL CONFIGURATION OF <br />EXISTING CONSTRUCTION AND THE CONDITION OF THE STRUCTURE BEFORE <br />BEGINNING WORK. ANY DISCREPANCIES OR UNSOUND CONDITIONS SHALL BE <br />REPORTED TO THE ENGINEER FOR RESOLUTION BEFORE BEGINNING WORK. <br />REFER TO MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR DUCTS, PIPING, <br />EMBEDMENTS, AND OPENINGS NOT SHOWN. <br />2. TEMPORARY SHORING AND BRACING MAY BE NECESSARY IN ORDER TO PERFORM <br />THE NECESSARY STRUCTURAL MODIFICATIONS TO THE EXISTING STRUCTURE <br />SHOWN ON THE STRUCTURAL AND ARCHITECTURAL DRAWINGS. THE CONTRACTOR <br />MUST SUBMIT PLANS AND SUPPORTING CALCULATIONS PREPARED BY A DESIGN <br />PROFESSIONAL LICENSED TO PERFORM WORK IN THE PROJECT JURISDICTION. <br />3. WHERE NEW STRUCTURAL WORK IS BEING PERFORMED, THE CONTRACTOR SHALL <br />VERIFY ALL DIMENSIONS AS REQUIRED PRIOR TO CONSTRUCTION. ANY <br />DISCREPANCIES SHALL BE REPORTED TO THE FOR FOR RESOLUTION PRIOR TO <br />BEGINNING WORK. <br />4. EXISTING CONSTRUCTION, FRAMING MEMBERS AND DIMENSIONS HAVE BEEN <br />ESTABLISHED BASED ON REVIEW OF THE AVAILABLE CONSTRUCTION DRAWINGS <br />FOR THE ORIGINAL BUILDING. ONLY LIMITED FIELD VERIFICATION HAS BEEN <br />PERFORMED. ANY DISCREPANCIES CONCERNING HOW NEW WORK RELATED TO <br />THE AS -BUILT CONSTRUCTION SHALL BE REPORTED TO THE <br />ARCHITECT/ENGINEER FOR RESOLUTION PRIOR TO BEGINNING WORK. <br />5. UNLESS SPECIFIED OTHERWISE, LOCATION AND ELEVATION OF NEW STRUCTURAL <br />ELEMENTS WITHIN THE ,EXISTING STRUCTURE ARE DETERMINED BY THEIR <br />RELATIONSHIP TO EXISTING CONDITIONS. THESE RELATIONSHIPS ARE <br />NOTED ON THE PLANS, SECTIONS AND DETAILS, <br />6. WHEN PROVIDED, DEMOLITION DRAWINGS INDICATE DEMOLITION EXTENT <br />ASSOCIATED WITH THE ACTUAL SIZE OF THE NEW ELEMENT. THE EXTENT OF <br />DEMO MAY NOT REFLECT ADDITIONAL DEMOLITION REQUIRED TO INSTALL NEW <br />ELEMENTS. IN ADDITION TO WHAT IS SHOWN ON THE ARCHITECTURAL <br />DEMOLITION DRAWINGS, MINOR LOCAL DEMOLITION OF EXISTING ELEMENTS MAY <br />BE REQUIRED TO PERFORM THE STRUCTURAL WORK AS INDICATED ON THE <br />PLANS, SECTIONS AND DETAILS. <br />SYM <br />REVISION <br />BY <br />APPR OVED <br />DATE <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />S. ®e <br />ACCEPTABILITY <br />CEIWN <br />UAIL <br />04.08.19 <br />SUBTITLE <br />A �� <br />CHECKED <br />T T L NOTES <br />ORIG <br />ACTIVATE STALL 113 777X CI REFURB 22999285 W6214003 <br />CEI <br />EO <br />04,08.19 <br />THIS DESIGN AND/OR <br />R. REEVES <br />O4.08.19 <br />�� <br />SPECIFICATION IS APPROVED <br />ENGINEER <br />TITLE <br />APPROVED BY <br />DEFT. <br />DATE <br />K. WANG <br />04.08.19 <br />ACTIVATE STALL 113 /777X Cl REFURB <br />CHECKED <br />� <br />04.08.19BUILDING <br />45-005 <br />APPROV ® <br />APPROVED <br />STRUCTURAL MASTER <br />ISSUED FOR" <br />04" r 8/2 uo" 9 <br />VVKICtlVI IStVIJIVIV JPMCSVL UHIt <br />22999285/W6214003 O G 04.08.19 <br />SHEET <br />S2A-2 <br />JOB NO. COMP N0. <br />22999265/W6214003 <br />DING N0. <br />EVERETT, WA 45-005-S2A-2 <br />