Laserfiche WebLink
DEMOLITION <br />1. ALL DEMOLITION SHALL BE <br />CARRIED ON IN SUCH A <br />MANNER <br />AS NOT TO DAMAGE <br />EXISTING ELEMENTS WHICH <br />ARE TO REMAIN A PART <br />OF THE <br />FINISHED STRUCTURE. <br />2. EXISTING ELEMENTS SHALL <br />BE PROTECTED TO THE <br />FULLEST <br />EXTENT POSSIBLE TO <br />REDUCE SUCH DAMAGE TO <br />A MINIMUM. <br />3. ALL ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN <br />AND WHICH ARE DAMAGED <br />DURING DEMOLITION WORK <br />SHALL BE REPLACED AT <br />NO ADDED COST. <br />4. CONTRACTOR TO COORDINATE <br />DEMO REQUIREMENTS <br />OF ANY <br />HAZARDOUS MATERIALS <br />WITH BOETNG. <br />STRUCTURAL STEEL, MISC. METAL <br />1. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM <br />TO THE BUILDING CODE AND AISC STANDARDS USING LOADS AS DEFINED IN <br />AISC-360 SECTION 83-3 "DESIGN FOR STRENGTH USING LOAD AND RESISTANCE <br />FACTOR DESIGN (LRFD)". <br />2. STRUCTURAL STEEL FABRICATION, ERECTION AND DIMENSIONAL TOLERANCES <br />OF STRUCTURAL STEEL MEMBERS SHALL CONFORM TO AISC REQUIREMENTS <br />AND THE PROJECT SPECIFICATIONS. <br />3. STRUCTURAL STEEL_ DETAILING, FABRICATION AND ERECTION OF ELEMENTS <br />AND CONNECTIONS MARKED `SLRS' SHALL CONFORM TO AISC-341. <br />4. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING, UNLESS OTHERWISE <br />NOTED ON THE STRUCTURAL DRAWINGS: <br />A. WIDE FLANGE SHAPES ASTM A992, Fy - 50 KSI <br />B. PLATES AND BARS ASTM A36, Fy = 36 KSI <br />C. CHANNELS AND ANGLES ASTM A36, Fy 36 KSI <br />D. HOLLOW RECTANGULAR SECTIONS ASTM A500-13, Fy = 46 KSI <br />E, ANCHOR RODS EMBEDDED IN CONCRETE ASTM F1554 GRADE 36 <br />F. CONNECTION BOLTS A325-N-STD <br />5. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS FOR <br />REVIEW AND APPROVAL PRIOR TO THE START OF FABRICATION. <br />6. WELDING SHALL BE PERFORMED iN ACCORDANCE WITH AWS REQUIREMENTS. <br />ALL WELDS SHALL BE PREQUALIFIED IN ACCORDANCE WITH AWS AND AISC <br />STANDARDS. USE E70XX ELECTRODES, UON. <br />7. WELDING OF MEMBERS AND CONNECTIONS MARKED 'SLRS' SHALL BE PERFORMED <br />IN ACCORDANCE WITH AWS D1.8. <br />A. ALL WELDS SHALL BE MADE WITH A FILLER WELD METAL THAT HAS A <br />MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBS AT 0 DEGREES F, <br />AS DETERMINED BY AWS CLASSIFICATION OR MANUFACTURER CERTIFICATION. <br />B. WELDS NOTED AS "DEMAND CRITICAL" SMALL BE MADE WITH A FILLER <br />WELD METAL MEETING THE REQUIREMENTS OF AISC 341 SECTION A3.4. <br />PROPOSED FILLER MATERIAL FOR BOTH SHOP AND FIELD WELDS SHALL <br />BE SUBMITTED FOR REVIEW PRIOR TO CONSTRUCTION. <br />8. ALL WELDS SHALL BE PERFORMED BY WELDERS CERTIFIED IN THE <br />JURISDICTION HAVING AUTHORITY OVER THIS PORTION OF THE WORK. <br />9. WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH <br />REQUIRED. WELD SIZE SHALL BE AISC MINIMUM, LION. <br />10. BOLTED CONNECTIONS OF MEMBERS MARKED 'SLRS' OR CONNECTIONS NOTED <br />AS SLIP CRITICAL SHALL BE PRETENSIONED AND SHALL MEET THE REQUIREMENTS <br />FOR A CLASS A FAYING SURFACE. CONNECTIONS AT THESE MEMBERS SHALL BE <br />MADE USING STANDARD HOLES IN ALL PLYS. <br />11. BEAM PENETRATIONS MAY BE CREATED PER THE TYPICAL DETAIL WITHOUT <br />PRIOR APPROVAL OF STRUCTURAL ENGINEER. PENETRATIONS OF ANY SIZE <br />IN ANY OTHER AREA OF THE MEMBER MUST BE REVIEWED AND APPROVED BY THE <br />STRUCTURAL ENGINEER. <br />12, TENSION CONTROL BOLTS MAY BE SUBSTITUTED FOR THE BOLTS SPECIFIED IN <br />THESE PLANS AT THE DISCRETION OF THE CONTRACTOR. ASTM F1852 TC <br />BOLTS MAY BE SUBSTITUTED FOR ASTM A325 BOLTS AND ASTM F2280 TC <br />BOLTS MAY BE SUBSTITUTED FOR ASTM A490. <br />13. A449, A193 GRADE B7, OR F1554 GRADE 105 THREADED ROD SHALL. BE <br />USED WHERE THRU BOLT LENGTH DOES NOT ALLOW FOR STANDARD A325 <br />BOLTS. PROVIDE ASTM A563 NUTS WITH MATCHED WASHERS AT BOTH ENDS. <br />14. USE DOUBLE NUTS OR SINGLE NUT AND PEENED THREADS AT BOLTED <br />CONNECTIONS WITH LONG SLOT HOLES. <br />15. HOLE SIZES IN STEEL MEMBERS CONNECTED TO CONCRETE OR MASONRY SHALL <br />BE 1/16" LARGER THAN THE BOLT DIAMETER. THE USE OF LARGER HOLES WOULD <br />REQUIRE THE USE OF WELDED PLATE WASHERS AND WOULD REQUIRE PRIOR <br />APPROVAL BY THE STRUCTURAL ENGINEER. HARDENED OR COMMON PLATE <br />WASHERS ARE REQUIRED BELOW ALL NUTS WHERE OVERSIZED HOLES ARE USED <br />AND SHALL BE SIZED TO COVER THE ENTIRE HOLE, MAXIMUM HOLE SIZES AND <br />MINIMUM WASHER SIZES FOR COLUMN BASE PLATES SHALL BE IN ACCORDANCE <br />WITH TABLE 14-2 OF THE AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION. <br />STRUCTURAL OBSERVATION <br />1. STRUCTURAL OBSERVATION IS REQUIRED FOR THE STRUCTURAL SYSTEM IN <br />ACCORDANCE WITH THE GOVERNING CODE. STRUCTURAL OBSERVATION IS THE <br />VISUAL OBSERVATION OF THE ELEMENTS AND CONNECTIONS OF THE STRUCTURAL <br />SYSTEMS AT SIGNIFICANT CONSTRUCTION STAGES AND THE COMPLETED STRUCTURE <br />FOR GENERAL CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. <br />STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE <br />INSPECTIONS REQUIRED OF THE BUILDING INSPECTOR OR THE DEPUTY INSPECTOR, <br />2. THE OWNER SHALL EMPLOY AN ENGINEER OR ARCHITECT LICENSED TO PERFORM <br />STRUCTURAL OBSERVATION IN THE PROJECT JURISDICTION. <br />3. THE STRUCTURAL OBSERVER SHALL PROVIDE A LETTER TO BE SUBMITTED TO THE <br />BUILDING OFFICIAL, AS REQUIRED BY THE JURISDICTION, BEFORE THE FIRST BUILDING <br />VISIT. THE STRUCTURAL OBSERVER SHALL ALSO INFORM THE OWNER OF THE <br />REQUIREMENTS FOR A PRECONSTRUCTION MEETING AND SHALL PRESIDE OVER THIS <br />MEETING. <br />STRUCTURAL OBSERVATION CONT. <br />4. THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE COMMUNICATION <br />BETWEEN THE ENGINEER RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL <br />OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND SPECIAL INSPECTORS. <br />THE PURPOSE OF THIS COMMUNICATION SHALL BE TO IDENTIFY THE MAJOR <br />STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL <br />LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED <br />OBSERVATIONS. <br />5. REPORTS SHALL BE ISSUED FOR EACH STRUCTURAL OBSERVATION AND ISSUED TO <br />THE OWNER, ARCHITECT, CONTRACTOR AND BUILDING OFFICIAL. A RECORD OF THE <br />PRECONSTRUCTION MEETING NOTED ABOVE SHALL BE INCLUDED IN THE FIRST <br />OBSERVATION REPORT, <br />6. THE CONTRACTOR SHALT_ SCHEDULE EACH OBSERVATION AT LEAST TWO WEEKS PRIOR <br />TO DATE OF THE PROPOSED OBSERVATION. <br />7. THE STRUCTURAL OBSERVER SHALL PERFORM OBSERVATIONS AT THE FOLLOWING <br />SIGNIFICANT CONSTRUCTION STAGES: <br />CONSTRUCTION STAGES ELEMENTS/CONNECTIONS TO BE OBSERVED: <br />A. AT SUBSTANTIAL_ COMPLETION OF THE PRIMARY STRUCTURE. <br />SPECIAL INSPECTION <br />1. SPECIAL INSPECTION BY A REGISTERED DEPUTY BUILDING INSPECTOR, <br />IN CONTRACT WITH THE OWNER AND APPROVED BY THE FOR AND THE <br />BUILDING OFFICIAL, SHALL BE REQUIRED FOR THE FOLLOWING TYPES OF WORK: <br />BUILDING CODE REFERENCE <br />STEEL 1705.2 AND <br />AISC 360 CHAPTER N <br />DETAIL VERIFICATION <br />WELDING OF STRUCTURAL STEEL <br />2. SPECIAL INSPECTIONS SHALL NOT BE REQUIRED WHEN THE WORK IS DONE ON <br />THE PREMISES OF A FABRICATOR REGISTERED AND APPROVED BY THE BUILDING <br />OFFICIAL TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. <br />3. NONDESTRUCTIVE INSPECTION OF ALL WELDS, SHOP AND FIELD, OF <br />MOMENT -RESISTING FRAMES SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />GOVERNING CODE. <br />4. SUMMARY REPORTS OF ALL INSPECTIONS AND TEST RESULTS SHALL BE <br />DISTRIBUTED TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER, AND <br />BUILDING OFFICIAL WITH DEFICIENCIES CLEARLY NOTED. <br />5. DEFICIENCIES SHALL BE REPORTED TO THE CONTRACTOR ON A DAILY BASIS. <br />6. DEFINITIONS OF SPECIAL INSPECTIONS AND TESTING FREQUENCY: <br />"CONTINUOUS" - THE FULL-TIME OBSERVATION OF WORK REQUIRING <br />SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS <br />PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED. <br />))PER.IODIC" - THE PART-TIME OR INTERMITTENT OBSERVATION OF WORK <br />REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO <br />IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING <br />B.EREQRMf_D TH CQM.PLETiO _F IE OR x_ <br />AISC 360 TABLE N5.4-1 <br />INSPECTION TASKS PRIOR TO WELDING <br />INSPECTION TASKS PRIOR TO WELDING <br />QC <br />QA <br />WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS <br />P <br />0 <br />WPS AVAILABLE <br />P <br />P <br />MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES <br />P <br />P <br />AVAILABLE <br />I <br />MATERIAL IDENTIFICATION (TYPE/GRADE) <br />0 <br />0 <br />WELDER IDENTIFICATION SYSTEM [a] <br />0 <br />0 <br />FIT -UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY) <br />- JOINT PREPARATIONS <br />- DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) <br />- CLEANLINESS (CONDITION OF STEEL SURFACES) <br />0 <br />0 <br />- TACKING (TACK WELD QUALITY AND LOCATION) <br />- BACKING TYPE AND FIT (IF APPLICABLE) <br />FIT -UP OF GROOVE WELDS OF HSS T-, Y- AND K-JOINTS <br />WITHOUT BACKING (INCLUDING JOINT GEOMETRY) <br />- JOINT PREPARATIONS <br />- DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) <br />P <br />0 <br />- CLEANLINESS (CONDITION OF STEEL SURFACES) <br />- TACKING (TACK WELD QUALITY AND LOCATION) <br />CONFIGURATION AND FINISH OF ACCESS HOLES <br />0 <br />0 <br />FIT -UP OF FILLET WELDS <br />- DIMENSIONS (ALIGNMENT, GAPS AT ROOT) <br />- CLEANLINESS (CONDITION OF STEEL SURFACES) <br />0 <br />0 <br />- TACKING (TACK WELD QUALITY AND LOCATION) <br />CHECK WELDING EQUIPMENT <br />0 <br />- <br />L°] THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY <br />WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. <br />STAMPS, IF USED, SHALL BE THE LOW -STRESS TYPE. <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />ORIG <br />FACTORY PRV/SRV DECK UPGRADE W5805116 <br />CEI <br />EO <br />04.09.20 <br />A <br />PERMIT SUBMITTAL W5805116 <br />CEI <br />EO <br />08.19.22 <br />AISC 360 TABLE N5.4-2 <br />INSPECTION TASKS DURING WELDING <br />INSPECTION TASKS DURING WELDING <br />QC <br />QA <br />CONTROL AND HANDLING OF WELDING CONSUMABLES <br />- PACKAGING <br />0 <br />0 <br />- EXPOSURE CONTROL <br />NO WELDING OVER CRACKED TACK WELDS <br />0 <br />0 <br />ENVIRONMENTAL CONDITIONS <br />- WIND SPEED WITHIN LIMITS <br />0 <br />0 <br />- PRECIPITATION AND TEMPERATURE <br />WPS FOLLOWED <br />- SETTINGS ON WELDING EQUIPMENT <br />- TRAVEL SPEED <br />- SELECTED WELDING MATERIALS <br />- SHIELDING GAS TYPE/FLOW RATE <br />0 <br />0 <br />- PREHEAT APPLIED <br />- INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.) <br />- PROPER POSITION (F, V, H, OH) <br />WELDING TECHNIQUES <br />- INTERPASS AND FINAL CLEANING <br />0 <br />0 <br />- EACH PASS WITHIN PROFILE LIMITATIONS <br />- EACH PASS MEETS QUALITY REQUIREMENTS <br />PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS <br />P <br />P <br />AISC 360 TABLE N5.4-3 <br />INSPECTION TASKS AFTER WELDING <br />INSPECTION TASKS AFTER WELDING <br />QC <br />QA <br />WELDS CLEANED <br />0 <br />0 <br />SIZE, LENGTH AND LOCATION OF WELDS <br />P <br />P__ <br />WELDS MEET VISUAL_ ACCEPTANCE CRITERIA <br />- CRACK PROHIBITION <br />- WELD/BASE-METAL FUSION <br />j <br />- CRATER CROSS SECTION <br />P <br />P <br />- WELD PROFILES <br />- WELD SIZE <br />- UNDERCUT <br />- POROSITY <br />ARC STRIKES <br />P <br />P <br />k-AREA <br />P <br />P <br />WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP <br />HEAVY SHAPES I'] <br />P <br />P <br />BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) <br />P <br />P <br />REPAIR ACTIVITIES <br />P <br />P <br />i <br />DOCUMENTS ACCEPTANCE OR REJECTION OF WELDED JOINT OR <br />P <br />P <br />MEMBER <br />NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE <br />0 <br />0 <br />APPROVAL OF THE FOR <br />WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS <br />HAS <br />BEEN PERFORMED IN THE k-AREA, VISUALLY INSPECT THE WEB k-AREA <br />FOR <br />CRACKS <br />WITHIN 3 IN. (75 MM) OF THE WELD. <br />I')] AFTER ROLLED HEAVY SHAPES (SEE SECTION A3,1 r) AND BUILT-UP <br />HEAVY <br />SHAPES (SEE SECTION A3.1 d) ARE WELDED, VISUALLY INSPECT THE <br />WELD ACCESS <br />HOLE FOR CRACKS. <br />AISC 360 TABLE N5.6-1 <br />INSPECTION TASKS PRIOR TO BOLTING <br />INSPECTION TASKS PRIOR TO BOLTING <br />QC <br />QA <br />MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENING <br />0 <br />P <br />MATERIALS <br />FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS <br />0 <br />0 <br />CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, <br />TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR <br />0 <br />0 <br />PLANE) <br />CORRECT BOLTING PROCEDURE SELECTED FOR JOINT DETAIL <br />0 <br />0 <br />CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING <br />SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET <br />0 <br />0 <br />APPLICABLE REQUIREMENTS <br />PRE -INSTALLATION VERIFICATION TESTING BY INSTALLATION <br />PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER <br />P <br />0 <br />ASSEMBLIES AND METHODS USED <br />PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND <br />0 <br />0 <br />OTHER FASTENER COMPONENTS <br />S. ACCEPTABILITY S. SARVER <br />A�THIS DESIGN AND/OR CHECKED _ <br />SPECIFICATION IS APPROVED K. WANG <br />ENGI_NE EG <br />APPROVED BY DEPT. DATE K. WANG <br />CHECKED <br />_ E. OJALA <br />AISC 360 TABLE N5.6--2 <br />INSPECTION TASKS DURING BOLTING <br />INSPECTION TASKS DURING BOLTING <br />QC <br />QA <br />FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS AND <br />0 <br />0 <br />NUTS ARE POSITIONED AS REQUIRED <br />JOINT BROUGHT TO SNUG -TIGHT CONDITION PRIOR TO THE <br />0 <br />0 <br />PRETENSIONING OPERATION <br />FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED <br />0 <br />0 <br />FROM ROTATING <br />FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC <br />SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID <br />0 <br />0 <br />POINT TOWARD THE FREE EDGES <br />AISC 360 TABLE N5.6-3 <br />INSPECTION TASKS AFTER BOLTING <br />INSPECTION TASKS AFTER BOLTING <br />QC <br />QA <br />DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS <br />P <br />P <br />O- OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT TO BE <br />DELAYED PENDING THESE INSPECTIONS. <br />P- PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER. <br />SUBMITTALS <br />1. THE FOLLOWING ITEMS SHALL BE SUBMITTED TQ THE STRUCTURAL ENGINEER <br />FOR REVIEW AND APPROVAL PRIOR TO FABRICATION/ERECTION/INSTALLATION. <br />THESE ITEMS ARE IN ADDITION TO ANY SUBMITTAL REQUIREMENTS SPECIFIED <br />ON THESE PLANS OR IN THE PROJECT SPECIFICATIONS. <br />ITEM PROD SHOP TEST CALCS BLDG <br />DATA DWGS RESULTS DEPT <br />A. STRUCTURAL STEEL X <br />B. PIPE SUPPORTS X X <br />2. "PROD DATA" - SUBMIT ADEQUATE DOCUMENTATION THAT THE PRODUCT <br />PROPOSED TO BE USED MEETS THE REQUIREMENTS ON THESE PLANS AND <br />THE PROJECT SPECIFICATIONS. <br />3. "SHOP DWGS" - SUBMIT COMPLETE SHOP DRAWINGS SUFFICIENT TO SHOW <br />QUANTITIES AND KINDS OF MATERIALS, METHODS OF ASSEMBLY, AND ALL <br />DATA REQUIRED FOR FABRICATION, ERECTION, AND INSTALLATION. THE <br />PURPOSE OF THESE DRAWINGS IS TO DEMONSTRATE THAT THE CONTRACTOR <br />UNDERSTANDS THE DESIGN CONCEPT DOCUMENTED HEREIN. SUBMITTALS <br />CONSISTING OF DRAWINGS TAKEN DIRECTLY FROM THESE PLANS WILL NOT <br />BE APPROVED. <br />4. "TEST RESULTS" - SUBMIT RESULTS FOR ANY TESTING REQUIRED BY <br />BUILDING CODE OR THESE PLANS. <br />5. "CALCS" - SUBMIT CALCULATIONS SIGNED AND SEALED BY A DESIGN <br />PROFESSIONAL AUTHORIZED TO PERFORM WORK IN THE PROJECT <br />JURISDICTION, <br />6. "BLDG DEPT" - IF CHECKED, THE SUBMITTALS SHALL BE REVIEWED AND <br />APPROVED BY THE BUILDING OFFICIAL PRIOR TO FABRICATION AND/OR <br />INSTALLATION, <br />GENERAL CONTRACTOR TO FIELD SURVEY ALL DIMENSIONS REQUIRED <br />TO COMPLETE THE WORK INDICATED IN THESE DRAWINGS. THESE <br />FIELD VERIFIED DIMENSIONS SHALL BE PROVIDED TO STEEL FABRICATOR <br />FOR INCORPORATION INTO THE SHOP DRAWINGS PRIOR -TO REVIEW. <br />PERMIT <br />SUBMITTAL <br />ISSUE FOR CONSTRUCTION <br />FEVERETT <br />EVIEWED FOR PERMIT <br />COFFMAN <br />A ENGINEERS <br />1101 2nd Avenue, Suite 400 <br />Seat <br />tle, VVA 98101 <br />ph 2m06.623.0 B d <br />w.coffman.com <br />CURRENT REVISION ISYMBOL <br />DATE <br />W5805116 >n � 08.19.22 <br />R/1 al?n?9 <br />STRUCTURAL MASTER <br />