, GENERAL POWER AND CONTROL <br />FLAG NOTE, IN CONSTRUCTION NOTE. <br />BOAT NOTE, IN GENERAL NOTE, <br />DETAIL NUMBER <br />1 <br />1 10 E5 ' DETAIL SHEET <br />CALLOUT SHEET <br />101 DOOR TAG <br />DISTRIBUTION SYSTEM <br />I= <br />DISTRIBUTION PANELBOARD 480Y/277V <br />POWER PANEL, 208Y/120V <br />E:= <br />SPECIAL PANEL AS NOTED <br />O <br />GROUND ROD, "TW" INDICATES TEST WELL <br />TW <br />(4)#1,G,1-1 /2"C <br />I'V N <br />HOME RUN -PANEL- CIRCUIT (EXAMPLE 2V57) CROSS MARKS <br />2V57- 4BMA10/2,4,6 <br />PNL-CKT <br />INDICATE QUANTITY OF CONDUCTORS (SIZE NOTED) LONGER SLASH <br />INDICATES NEUTRAL WIRE (IF REQUIRED). IF UNMARKED INSTALL 3#12 AWG <br />IN 3/4 " CONDUIT. REVERSED SLASH INDICATES GROUND WIRE. <br />CONDUIT EXPOSED (RIGID METAL) <br />CONDUIT EMBEDDED IN CONCRETE OR BELOW GRADE <br />—�/ <br />FLEXIBLE METAL OR LIQUIDTIGHT FLEX METAL CONDUIT AS NOTED <br />- <br />CONDUIT TURNING UP <br />CONDUIT TURNING DOWN <br />G <br />GROUND WIRE (SIZE AS NOTED) <br />G <br />GROUND WIRE WITH EXOTHERMIC WELD CONNECTION <br />E <br />EMERGENCY CIRCUIT <br />L <br />EXPOSED LIGHTNING PROTECTION CONDUCTOR <br />ETBj <br />JUNCTION BOX, SPECIAL (SIZE NOTED, "WP"-WEATHERPROOF) <br />PB <br />PULL BOX (SIZE NOTED, "WP"-WEATHERPROOF) <br />® <br />FIELD TERMINAL BOX <br />E-1/01 <br />REMOTE 1/0 RACK <br />PM I <br />POWER MONITOR DEVICE <br />SYM <br />A <br />B <br />® TRANSFORMER (CAPACITY, PHASE & VOLTAGE AS NOTED) <br />NON -FUSED DISCONNECT SWITCH (ENCLOSED BREAKER OR MOLDED <br />XX/Y CASE SWITCH WHERE FAULT CURRENT EXCEEDS 1 OKA) <br />FF NN EXP XX- SWITCH RATING <br />(ZMM6nZW�4<DB <br />EXP - EXPLOSION PROOF (CLASS I / DIV I UNLESS NOTED OTHERWISE) <br />ENCLOSED CIRCUIT BREAKER <br />STARTER <br />(M) MOTOR (SIZE AS NOTED) <br />O GENERATOR, ALTERNATING CURRENT (VOLTAGE, KVA, <br />PHASES, FREQUENCY AS NOTED) <br />RECEPTACLE 20 AMP DUPLEX, 2 POLE, 3 WIRE <br />r@E20 CLASS I, DIVISION I EXPLOSION PROOF GFCI 125V, 20A, 2P, 3W <br />EXP INTERLOCKING RECEPTACLE. GROUSE HINDS CPS152 (RECEPTACLE) <br />AND GFS-1 (GFI MODULE) OR APPROVED ALTERNATE. <br />ABOVE COUNTER RECEPTACLE 20 AMP DUPLEX, 2 POLE, 3 WIRE <br />SIG ISOLATED GROUND RECEPTACLE, 20AMP, DUPLEX, 2 POLE, 3 WIRE <br />j aGFI <br />GROUND FAULT INTERRUPT RECEPTACLE, 20AMP, DUPLEX, 2 POLE, 3WIRE <br />WP <br />WP INDICATES WEATHER PROOF <br />RECEPTACLE 20AMP 4-PLEX, 2 POLE, 3 WIRE <br />RECEPTACLE, NEMA CONFIGURATION AS INDICATED. <br />L6-20R <br />RECEPTACLE, 4801 20A SINGLE, 3P, 4W LOCKING TYPE NEMA L6-20 <br />GROUNDING <br />RECEPTACLE, 208V/1 PH, 30A SINGLE, 2P, 3W LOCKING TYPE NEMA L6-30 <br />GROUNDING <br />Q <br />JUNCTION BOX, FIELD SIZED PER NEC. <br />0FSD <br />JUNCTION BOX, 120V CONNECTION FOR FIRE -SMOKE DAMPER <br />QMOD <br />JUNCTION BOX, 120V CONNECTION FOR MOTOR -OPERATED DAMPER <br />CONNECTION TO EQUIPMENT AS INDICATED. <br />MECHANICAL EQUIPMENT TAG. <br />$M <br />MOTOR RATED SWITCH <br />POKE THRU DEVICE - REFER TO DETAIL 3 ON SHEET E508-02-46 <br />PT_X <br />PT-1 - 6" POWER/DATA/AV POKE THRU DEVICE <br />PT-2 - 8" POWER/DATA/AV POKE THRU DEVICE <br />REVISION <br />BY <br />APPROVED <br />777X CWC NEW BUILDING - RECORD WBS 2548317 <br />JMG <br />DFC <br />PFP SPAR PAINT BOOTH 1 AND 2 - XXX W5983281 <br />HG <br />RLT <br />I <br />Y12 <br />MEDIUM VOLTAGE CIRCUIT BREAKER DRAWOUT TYPE <br />v <br />FUSE <br />AF <br />LOW VOLTAGE CIRCUIT BREAKER. <br />AMP FRAME/AMP TRIP, <br />25 <br />SYNCHRONISM - RELAY <br />27 <br />UNDER VOLTAGE RELAY <br />TINSTANTANEOUS/TIME <br />OVERCURRENT <br />RELAY <br />51 N <br />INSTANTANEOUS/TIME NEUTRAL <br />MR <br />PM <br />AS <br />VS <br />Myl <br />OVERCURRENT RELAY <br />POWER FACTOR CORRECTION CAPACITORS <br />(FUSED) <br />CONTROL POWER TRANSFORMER <br />"• ,_1 101 •1mu; <br />MULTI-RATIOALLEN-BRADLEY POWER MONITOR 5000 <br />ANALOG AMMETER <br />AMMETER SWITCH <br />VOLTMETER SWITCH REIJ <br />ANALOG VOLTMETER <br />SYSTEM GROUND <br />lin In •"" a • <br />MOTOR STARTER (MANUAL) <br />SOLENOID VALVE <br />[Eil REMOTE CONTROL STATION (TYPE AS NOTED) <br />0 EMERGENCY POWER SHUTDOWN <br />T 3-COMPARTMENT POWER POLE WIRE MOLD 30TP-4 <br />PF <br />2-COMPARTMENT POWER POLE WIRE MOLD 30TP-3 <br />SOB <br />SWITCH BYPASS DEVICE <br />CB <br />MANUAL CONTROLLER <br />TB <br />TEST BLOCK <br />LOW VOLTAGE CIRCUIT BREAKER. <br />0 <br />v <br />DRAWOUT TYPE <br />`_`_J <br />ELECTRICALLY OPERATED <br />.J <br />UNIT SUBSTATION TRANSFORMER <br />49 <br />OVERLOAD RELAY <br />86 <br />LOCKOUT RELAY <br />G1 G2 <br />KIRK KEY INTERLOCKS. SEE BOEING <br />27 <br />STANDARDS <br />UNDERVOLTAGE RELAY <br />46 <br />REVERSE PHASE CURRENT RELAY <br />47 <br />PHASE SEQUENCE VOLTAGE RELAY <br />25 <br />SYNCHRONIZING DEVICE <br />LIGHTNING ARRESTER <br />PRIMARY MEDIUM VOLTAGE FUSED <br />SWITCH <br />MEDIUM VOLTAGE CABLE TERMINATION <br />GF <br />GROUND FAULT MONITOR <br />SP® <br />SURGE PROTECTIVE DEVICE <br />SG <br />STATIC GROUND RECEPTACLE <br />MOTOR LOAD <br />WELDING RECEPTACLE <br />DATE SYM REVISION <br />01/03117 <br />XX.XX,XX <br />BY I APPROVED <br />DATE <br />LIGHTING FIXTURES: UPPER CASE ALPHA -NUMERIC CHARACTER INDICATES FIXTURE TYPE. <br />LOWER CASE ALPHA -NUMERIC CHARACTER INDICATES CIRCUIT NUMBER AND PHASE FED FROM. <br />UPPER CASE ALPHA -NUMERIC CHARACTER IN PARENTHESIS INDICATES RELAY NUMBER. <br />LOWER CASE LETTER INDICATES SWITCH LEG. <br />"NL" INDICATES NIGHT LIGHT OPERATION (CIRCUIT NOT SWITCHED), <br />STRUCTURE MOUNTED LED HIGH BAY FIXTURE. EACH FIXTURE SHALL INCLUDE <br />A QUICK DISCONNECT AND IN -LINE FUSE. <br />STRUCTURE MOUNTED LED HIGH BAY FIXTURE (EMERGENCY). EACH FIXTURE <br />SHALL INCLUDE A QUICK DISCONNECT AND IN -LINE FUSE. <br />i-�—I INDUSTRIAL FLUORESCENT/LED LIGHTING FIXTURE. <br />INDUSTRIAL FLUORESCENT/LED LIGHTING FIXTURE (EMERGENCY) <br />WALL/RECESSED/SURFACE MOUNTED FLUORESCENT/LED LIGHTING FIXTURE. <br />WALURECESSED/SURFACE MOUNTED FLUORESCENT/LED LIGHTING FIXTURE (EMERGENCY) <br />3 I� <br />PHASE <br />4801 VAC POWER CABLES <br />A -PHASE (LEFT BUS IN PNL) <br />BROWN <br />B-PHASE (CENTER BUS IN PNL) <br />ORANGE <br />C-PHASE (RIGHT BUS IN PNL) <br />YELLOW <br />NEUTRAL <br />GRAY <br />EQUIPMENT GROUND <br />GREEN <br />ISOLATED GROUND <br />GRN/YEL* <br />* GREEN WITH YELLOW <br />TRACER <br />LIGHTING CONTROL SWITCHES AND OCCUPANCY SENSORS: ADDITIONAL LOWER CASE <br />LETTER INDICATES SWITCH LEG. <br />SINGLE POLE TOGGLE WALL SWITCH <br />$3 THREE-WAY TOGGLE WALL SWITCH <br />$OS LINE -VOLTAGE OCCUPANCY SENSOR WALL SWITCH <br />$ WP SINGLE POLE TOGGLE WALL SWITCH, WEATHERPROOF <br />XX $LV LOW -VOLTAGE, 2-BUTTON ON/OFF WALL SWITCH. SWITCH TO TIE <br />INTO GE LIGHTSWEEP LIGHTING CONTROL PANEL(S) SERVING <br />RESPECTIVE AREA. REFER TO GE LIGHTING LIGHTSWEEP CONTROL <br />DRAWINGS FOR MORE INFORMATION <br />WHERE SHOWN)FIRST DIGIT REPRESENTS FLOOR (U - 2ND FLOOR, V - 3RD FLOOR) <br />SECOND DIGIT SPECIFIES LIGHTING CONTROL ZONE. SEE CONTROL ZONE PLANS 2E8 <br />AND 3E8 FOR ADDITIONAL INFORMATION. <br />OC CEILING MOUNTED, LOW -VOLTAGE, DUAL TECHNOLOGY OCCUPANCY SENSOR WITH POWER PACK <br />LCP POWER PACK: HUBBELL #UVPP OR APPROVED EQUAL (FOR EACH OCCUPANCY SENSOR) <br />ROOMS: HUBBELL #OMNI-DT-500/100 OR APPROVED EQUAL (500/1000 SQ. FEET) <br />CORRIDORS/TUNNELS: HUBBELL #OMNI-DT-2000 OR APPROVED EQUAL (2,000 SQ, FEET) <br />SUBSCRIPT INDICATES LOW VOLTAGE OCCUPANCY SENSOR WIRED BACK TO GE LIGHTING CONTROL PANEL <br />INDICATED. <br />BUILDING MOUNTED PHOTOCELL. <br />ZONE X $H13 <br />LOW -VOLTAGE, 2-BUTTON HIGH BAY LIGHTING WALL SWITCH WITH <br />DESIGNATED ZONE. SWITCH TO TIE INTO GE LIGHTSWEEP LIGHTING <br />CONTROL PANEL(S) SERVING RESPECTIVE ZONES. BUTTONS SHALL <br />INCLUDE:'OVERRIDE' AND'UNASSIGNED'. REFER TO GE LIGHTING <br />LIGHTSWEEP CONTROL DRAWINGS FOR MORE INFORMATION, <br />$ T <br />120 MINUTE TIMER WALL SWITCH <br />$D <br />SINGLE -POLE DIMMER WALL SWITCH <br />ALUMINUM LADDER TYPE CABLE TRAY. SIZE & HEIGHT AS NOTED ON DRAWINGS. <br />12" CABLE RUNWAY, <br />CE <br />COMMUNICATIONS ENCLOSURE. <br /><# <br />2-PORT MODULAR STAINLESS STEEL FACEPLATE WITH (1) CAT 5e CABLE FROM"CE" OR "CR, INDICATED AND <br />(1) RJ-45 CONNECTOR FOR DATA OUTLET. PROVIDE BLANK COVER FOR UNUSED PORT. SUBSCRIPT <br />INDICATES NUMBER OF ACTIVE JACKS IF GREATER THAN 1. <br />E <br />STAINLESS STEEL FACEPLATE WITH MOUNTING STUD SCREWS, (1) CAT 5e UTP CABLE FROM 110 PUNCH - <br />DOWN BLOCKS INDICATED AND (1) RJ-45 CONNECTOR FOR ANALOG EMERGENCY PHONE OUTLET. MOUNT <br />OUTLET AT 48" AFF, LION. COORDINATE EXACT LOCATION WITH OWNERS FIRE SAFETY REPRESENTATIVE <br />PRIOR TO ROUGH -IN. <br />(�) <br />CCTV OUTLET FOR INTERIOR CAMERA: SURFACE MOUNTED BOX INSTALLED ABOVE CEILING ON TILE BRIDGE <br />�-✓ <br />WITH 1-PORT MODULAR FACEPLATE WITH (1) CAT 5e UTP CABLE AND (1) RJ-45 CONNECTOR. ROUT CAT5e <br />CABLE BACK TO "CE" OR "CR" INDICATED. CAMERA PROVIDED BY OTHERS. <br />2-PORT MODULAR STAINLESS STEEL FACEPLATE WITH (1) CAT 5e UTP CABLE FROM "CE" OR "CR" INDICATED <br />AND (1) CAT 5e CABLE FROM 110 PUNCHDOWN BLOCKS INDICATED AND (2) RJ-45 CONNECTORS. <br />PB <br />PULLBOX. SIZE AND TYPE AS NOTED ON DRAWINGS. <br />NOW PAINTED FIRE RETARDANT PLYWOOD BACKBOARD. <br />110 <br />110 STYLE PUNCHDOWN BLOCKS. <br />CCVT <br />CCTV ENCLOSURE FOR EXTERIOR CAMERA. <br />AMS <br />AMS PANEL. <br />BR <br />BADGE READER, <br />BR <br />PREPPED DOOR AND BADGE READER <br />P <br />IS <br />SUBSTATION POWER MONITOR NETWORK POINT OF CONNECTION. COORDINATE WITH OWNER FOR EXACT <br />LOCATION WITHIN SUBSTATION, <br />CEILING MOUNTED VOICE/DATA OUTLET WITH (1) CAT 5e CABLE AND (1) RJ-45 CONNECTOR TO "CE" OR "CR" <br />INDICATED. LOCATE ADJACENT TO PROJECTOR POWER RECEPTACLE. <br />2-PORT MODULAR OUTLET WITH (1) CAT 5e CABLE FROM "CE" OR "CR" INDICATED AND (1) RJ-45 CONNECTOR <br />FOR DATA OUTLET. OUTLET IS MOUNTED WITHIN MULTI -PURPOSE POKE-THRU/ FLOORBOX. REFER TO <br />208/120V POWER DRAWINGS FOR POKE THRU/ FLOORBOX LOCATIONS. PROVIDE BLANK COVER FOR <br />UNUSED PORT. SUBSCRIPT INDICATES NUMBER OF ACTIVE JACKS IF GREATER THAN 1. <br />DMS <br />DOOR MONITORING SYSTEM. <br />VENTILATION SYSTEM EMERGENCY SHUTOFF SWITCH. <br />XE 4 V58-3A M A2-1-D <br />208Y/120 VAC POWER CABLES <br />BLACK <br />RED <br />BLUE <br />WHITE <br />GREEN <br />GRN/YEL* <br />**TI BUILDOUT ONLY - PROVIDE <br />NEETRAL WITH COLOR TRACER TO <br />MATCH PHASE <br />ule <br />LSUFFIX "D" INDICATES DISTRIBUTION PANEL <br />SUFFIX "-1, -2, ETC." USED TO INDICATE MULTIPLE PANELS AT SAME LOCATION WITH SAME VOLTAGE AND FED FROM SAME VAULT <br />NEAREST COLUMN INTERSECTION <br />LOCATION OF PANEL WHEN NOT ON FIRST FLOOR: <br />TN1 = TUNNEL LEVEL 1 <br />TN2 = TUNNEL LEVEL 2 <br />P = AUTOCLAVE PIT <br />M = MEZZANINE <br />U = LEVEL 2 <br />V = LEVEL 3 <br />C = CATWALK <br />RF = ROOF <br />VAULT <br />VOLTAGE: <br />4 = 480V, 3PH, 3W <br />3 = 480Y/277V, 3PH, 4W <br />2 = 208Y/120V, 3PH, 4W OR 120/24OV,1 PH, 3W <br />Sam <br />(BLANK) = NORMAL POWER PANEL <br />"I" = ISOLATED GND PANEL <br />"Z" = 400 HZ PANEL <br />"XF" = EMERGENCY PANEL <br />"XL" = LEGALLY REQUIRED STANDBY PANEL <br />"XS" = OPTIONAL STANDBY PANEL <br />"'XU" = UPS SYSTEM <br />ACCEPTABILITY <br />THIS DESIGN AND/OR <br />JKAWN <br />RER <br />CHECKED <br />UAIt SUBTITLE <br />12105/14 <br />ELECTRICAL LEGEND <br />SPECIFICATION IS APPROVED <br />RFW <br />12/05114 <br />APPROVED BY DEPT. DATE <br />ENGINEER <br />DFC <br />TITLE <br />12/05/14 <br />PEP SPAR PAINT BOOTH 1 AND 2 <br />CHECKED <br />BUILDING 40-058 <br />APPROVED <br />0 <br />DRAWN: NH <br />ENGINEER: EOF <br />CHECKED: MWD <br />CURRENT REVISION SYMBOL <br />W5953281 <br />SHEET <br />JOB No. <br />EVERETT, WA DWG No. <br />00- <br />Our difference <br />is engineered. <br />www.harrisgroup.com <br />REVISION °C" ONLY <br />PROJECT NO: 0012630.06 <br />PROJ MGR: RLT <br />APPROVED: RLT <br />DATE: XX.XX.XX <br />XX.XX.XX <br />COMP NO. <br />ELECTRICAL MASTER <br />