111.
<br />{IIIIL• F1FTU
<br />(SOME ABBREVIATIONS MAY NOT PERTAIN TO THIS PROJECT)
<br />A
<br />AMPERES
<br />FA
<br />FIRE ALARM
<br />A/C
<br />AIR CONDITIONING
<br />FRCP
<br />FIRE ALARM CONTROL PANEL
<br />AC
<br />ALTERNATING CURRENT
<br />FAPS
<br />FIRE ALARM POWER SUPPLY
<br />AC
<br />AIR CONDITIONING
<br />FATC
<br />FIRE ALARM TERMINAL CABINET
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />FBO
<br />FURNISHED BY OTHERS
<br />AEG
<br />ABOVE FINISHED GRADE
<br />FB
<br />FLOOR BOX
<br />AFS
<br />ABOVE FINISHED SLAB
<br />FC
<br />FLEX CONDUIT
<br />AGE
<br />ABOVE GROUND FLOOR
<br />FDC
<br />FIBER DISTRIBUTION CENTER
<br />AHU
<br />AIR HANDLING UNIT
<br />FLA
<br />FULL LOAD AMPERES
<br />AHDD
<br />AIR HANDLING DESIGN DELIVERY
<br />FO
<br />FIBER OPTIC
<br />AMS
<br />ACCESS MANAGEMENT SYSTEM
<br />FOC
<br />FIBER OPTC CABLE
<br />APPROX
<br />APPROXIMATELY
<br />FUT
<br />FUTURE
<br />AT
<br />ADJUSTABLE TRIP
<br />FS
<br />FLOW SWITCH
<br />ATR
<br />ALL THREAD ROD
<br />FSD
<br />FIRE SMOKE DAMPER
<br />ATS
<br />AUTOMATIC TRANSFER SWITCH
<br />G
<br />GROUND
<br />AN
<br />AUDIONISUAL
<br />GAP
<br />GENERATOR ANNUNCIATOR PANEL
<br />AWG
<br />AMERICAN WIRE GAUGE
<br />GB
<br />GROUND BAR
<br />BC
<br />BARE COPPER
<br />GEN
<br />GENERATOR
<br />BD
<br />BYPASS DAMPERS
<br />GF
<br />GROUND FAULT
<br />BEP
<br />BUILDING ENTRANCE PROTECTOR
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />BLDG
<br />BUILDING
<br />BOD
<br />BILL OF MATERIALS
<br />GFCI
<br />GROUND FAULT CIRCUIT INTERRUPTER
<br />GND
<br />GROUND
<br />BOM
<br />BILL OF MATERIALS
<br />GRC
<br />GALVANIZED RIGID CONDUIT
<br />BOT
<br />BOTTOM OF TRAY
<br />GWH
<br />GAS WATER HEATER
<br />BOF
<br />BOTTOM OF FIXTURE
<br />BR
<br />BADGE READER
<br />HCM
<br />HORIZONTAL CABLE MANAGER
<br />HID
<br />HIGH INTENSITY DISCHARGE
<br />BTM
<br />BOTTOM
<br />HH
<br />HANDHOLE
<br />C
<br />CONDUIT
<br />HP
<br />HORSE POWER
<br />CCTV
<br />CLOSED CIRCUIT TELEVISION
<br />HPS
<br />HIGH PRESSURE SODIUM
<br />CD
<br />CANDELLA
<br />HSE
<br />HOUSE
<br />CE
<br />COMMUNICATIONS ENCLOSURE
<br />HVAC
<br />HEATING, VENTILATING AND AIR CONDITIONING
<br />CH
<br />COUNTER HEIGHT
<br />IC
<br />INTERCOM
<br />COMM
<br />COMMUNICATION
<br />ICJB
<br />INTERCOM JUNCTION BOX
<br />CONC
<br />CONCRETE
<br />IMT
<br />INTELLIGENT MONITORING TECHNOLOGY
<br />COND
<br />CONDUIT
<br />INST
<br />INSTRUMENT/INSTRUMENTATION
<br />CORR
<br />CORRIDOR
<br />ISP
<br />INSIDE PLANT
<br />CONVICT
<br />CONVECTION
<br />J
<br />JUNCTION
<br />CID
<br />CIRCULATING PUMP
<br />JB
<br />JUNCTION BOX
<br />CR
<br />COMM ROOM
<br />KAIC
<br />(THOUSAND) AMPERE INTERRUPTING CAPACITY
<br />CT
<br />CURRENT TRANSFORMER
<br />KCMIL
<br />(THOUSAND) CIRCULAR MILS
<br />CTL
<br />CONTROL
<br />KK
<br />KIRK KEY INTERLOCK
<br />CTRL
<br />CONTROL
<br />KVA
<br />KILOVOLT -AMPERES
<br />CU
<br />COPPER
<br />KW
<br />KILOWATT
<br />CUDD
<br />CONDENSING UNIT DESIGN DELIVERY
<br />LB
<br />LOAD BANK
<br />CW
<br />COOL WHITE
<br />LC
<br />LIGHTING CONTACTOR
<br />DB
<br />DUCT BANK
<br />LCU
<br />LOCAL CONTROL UNIT
<br />DC
<br />DIRECT CURRENT
<br />LCP
<br />LIGHTING CONTROL PANEL
<br />DCS
<br />DATA COLLECTION SYSTEM
<br />LED
<br />LIGHT EMITTING DIODE
<br />DH
<br />DOOR HOLD
<br />LTG
<br />LIGHTING
<br />DIA
<br />DIAMETER
<br />LSIG
<br />LONG TIME, SHORT TIME
<br />DISC
<br />DISCONNECT
<br />INSTANTANEOUS AND GROUND FAULT TRIPS
<br />DIV
<br />DIVISION
<br />LVT
<br />LINE VOLTAGE THERMOSTAT
<br />DM
<br />DEHUMIDIFIER
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />DMC
<br />DOOR MONITORING SYSTEM
<br />MCS
<br />MOLDED CASE SWITCH
<br />DMW
<br />DIMMING MICRO WATT PANEL
<br />MECH
<br />MECHANICAL
<br />DP
<br />DISTRIBUTION PANEL
<br />MEZZ
<br />MEZZANINE
<br />DPC
<br />DIMMING PANEL
<br />MDF
<br />MAIN DISTRIBUTION FRAME
<br />DPST
<br />DOUBLE POLE SINGLE THROW
<br />MDP
<br />MAIN DISTRIBUTION POWER
<br />DS
<br />DISCONNECT SWITCH
<br />MCM
<br />THOUSANDS OF CIRCULAR MILS
<br />DT
<br />DUCT DETECTOR
<br />MCU
<br />MASTER CONTROL UNIT
<br />EC
<br />ELECTRICAL CONTACTOR
<br />MH
<br />METAL HALIDE
<br />DWG
<br />DRAWING
<br />MH
<br />MANHOLE
<br />ECB
<br />ENCLOSED CIRCUIT BREAKER
<br />MIN
<br />MINIMUM
<br />EFDD
<br />EXHAUST FAN DESIGN DELIVERY
<br />MM
<br />MULTIMODE
<br />EL
<br />ELEVATION
<br />MR
<br />MOTOR RATED
<br />ELEC
<br />ELECTRICAL/ELECTRIC
<br />MS
<br />MOTOR STARTER
<br />ELI
<br />EMERGENCY LIGHTING INTERFACE
<br />MTD
<br />MOUNTED
<br />EM
<br />EMERGENCY
<br />MTR
<br />METER
<br />EMH
<br />ELECTRICAL MANHOLE
<br />N
<br />NEUTRAL
<br />EMS
<br />ENERGY MANAGEMENT SYSTEM
<br />NA
<br />NOT APPLICABLE
<br />EMT
<br />ELECTRICAL METALLIC TUBING
<br />NAG
<br />NOTIFICATION APPLIANCE CIRCUIT
<br />EP
<br />EXPLOSION -PROOF (RATED FOR
<br />N.C.
<br />NORMALLY CLOSED
<br />HAZARDOUS LOCATION)
<br />NE
<br />NORTH EAST
<br />EPB
<br />EMERGENCY PUSH BUTTON
<br />NEC
<br />NATIONAL ELECTRICAL CODE
<br />NEMA
<br />NATIONAL ELECTRICAL MANUFACTURERS
<br />EWC
<br />ELECTRIC WATER COOLER
<br />ASSOCIATION
<br />EWH
<br />ELECTRIC WATER HEATER
<br />NF
<br />NON -FUSED
<br />EF
<br />EXHAUST FAN
<br />NFPA
<br />NATIONAL FIRE PROTECTION ASSOCIATION
<br />EX
<br />EXTERIOR
<br />NIC
<br />NOT IN CONTRACT
<br />EXT
<br />EXTERIOR
<br />NL
<br />NIGHT LIGHT
<br />EXIST
<br />EXISTING
<br />NO
<br />NUMBER
<br />EXP
<br />EXPLOSION PROOF CLASS 1, DIV 1
<br />N.O.
<br />NORMALLY OPEN
<br />ETU
<br />ELECTRONIC TRIP UNIT
<br />NTS
<br />NOT TO SCALE
<br />NW
<br />NORTH WEST
<br />OC
<br />ON CENTER
<br />OL
<br />OVERLOAD
<br />OCPD
<br />OVER CURRENT PROTECTIVE DEVICE
<br />OSP
<br />OUTSIDE PLANT
<br />SYM
<br />REVISION
<br />BY
<br />APPROVED
<br />DATE SYM
<br />A
<br />777X CWC NEW BUILDING - RECORD WBS 2548317
<br />PEP SPAR PAINT BOOTH 1 AND 2- XXX W5983281
<br />JMG
<br />DEC
<br />01/03/17
<br />B
<br />HG
<br />RLT
<br />XX.XX.XX
<br />REVISION
<br />1.
<br />ELECTRICAL SERVICE TO AND FOR MECHANICAL AND OTHER EQUIPMENT IS BASED ON EQUIPMENT DESIGN
<br />22,
<br />INSTALL 120 VOLT CONVENIENCE OUTLETS 48" A.F.F. FOR COLUMN MOUNTED AND 18" A.F.F. FOR WALL
<br />P
<br />POLE
<br />DATA - THE VALUES MAY DIFFER DEPENDING UPON THE ACTUAL EQUIPMENT TO BE FURNISHED. COORDINATE
<br />MOUNTED.
<br />PB
<br />PUSH BUTTON
<br />RATINGS WITH OTHER TRADES PRIOR TO ORDERING ELECTRICAL EQUIPMENT, ANY MODIFICATION TO THE
<br />ELECTRICAL INSTALLATION BASED UPON ACTUAL EQUIPMENT SELECTION, SHALL RESULT IN NO ADDITIONAL
<br />23.
<br />UNLESS OTHERWISE NOTED, RECEPTACLES SHOWN MOUNTED ON STEEL COLUMNS SHALL BE MOUNTED
<br />PC
<br />PHOTOCELL
<br />COST TO THE CONTRACT.
<br />IN COLUMN WEB.
<br />PH
<br />PHASE
<br />PLC'S
<br />PLACES
<br />2.
<br />THOROUGHLY REVIEW ALL DESIGN DOCUMENTS TO ASSURE THAT ELECTRICAL SERVICE FOR ALL ITEMS
<br />24.
<br />CONDUITS AND CABLE TRAYS SHALL MAINTAIN A MINIMUM CLEARANCE OF VI FROM HOT WATER AND
<br />AND/OR EQUIPMENT REQUIRING ELECTRICAL SERVICE IS INCLUDED. ANY ITEM AND/OR EQUIPMENT NOT
<br />STEAM PIPES. ALL OTHER PIPING CLEARANCES SHALL BE A MINIMUM OF SIX (6) INCHES.
<br />PNL
<br />PANEL
<br />PROVIDED WITH ELECTRICAL SERVICE, REQUIRING ELECTRICAL SERVICE, SHALL BE IMMEDIATELY BROUGHT
<br />POC
<br />POINT OF CONNECTION
<br />TO THE OWNERS ATTENTION.
<br />25,
<br />WHERE COMMUNICATIONS DEVICES ARE BEING PROVIDED IN CLOSE PROXIMITY T0120V RECEPTACLES,
<br />POE
<br />POWER OVER ETHERNET
<br />SUCH DEVICES SHALL BE INSTALLED AT THE SAME HEIGHT AS RECEPTACLES WITH MINIMUM 12" OF
<br />PP
<br />POWER POLE
<br />3.
<br />MECHANICAL AND ELECTRICAL EQUIPMENT HAS BEEN LOCATED AND ARRANGED TO MINIMIZE THE
<br />SEPERATION BETWEEN THEM.
<br />PPD
<br />POWER PANEL DISTRIBUTION
<br />INTERFERENCES OF EQUIPMENT AND STRUCTURE. THOROUGHLY BECOME FAMILIAR WITH THE WORK TO BE
<br />26.
<br />REFER TO MECHANICAL EQUIPMENT SCHEDULE, FOR CONDUIT/CONDUCTORS, DISCONNECTS,
<br />PM
<br />POWER MONITOR
<br />PERFORMED BY ALL TRADES AND THE PHYSICAL CHARACTERISTICS OF THE STRUCTURE IN ORDER TO
<br />MISCELLANEOUS EQUIPMENT REQUIRED FOR ALL MECHANICAL EQUIPMENT.
<br />SCHEDULE AND INSTALL EQUIPMENT AND TO MINIMIZE POSSIBLE INTERFERENCE. FAILURE TO PROPERLY
<br />PRI
<br />PRIMARY
<br />COMMUNICATE AND SCHEDULE WORK WITH OTHER TRADES RESULTING IN ADDITIONAL WORK AND MATERIAL,
<br />27.
<br />ALL ELECTRIC WATER COOLER (EWC) RECEPTACLES SHALL BE INSTALLED BEHIND THE COOLER'S
<br />PS
<br />PRESSURE SWITCH
<br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
<br />ENCLOSURE,
<br />PTZ
<br />PAN -TILT -ZOOM
<br />PVC
<br />POLYVINYL CHLORIDE
<br />4.
<br />UNLESS NOTED ON E700 SERIES DRAWINGS, MOTOR STARTERS AND DISCONNECT SWITCHES ARE FURNISHED
<br />28.
<br />VERIFY ALL POWER AND LIGHTING CIRCUITS IN THE FIELD PRIOR TO REUSE FOR FEEDING NEW
<br />BY DIVISION 23 AND SHALL BE INSTALLED AND WIRED BY DIVISION 26.
<br />PWR
<br />POWER
<br />LOADS,
<br />RECP
<br />RECEPTACLE
<br />5.
<br />EQUIPMENT INSTALLED WITHIN CONCEALED SPACES SHALL HAVE REASONABLE AND CODE COMPLIANT
<br />29.
<br />FOR UNDERGROUND CONDUITS 1-112" AND LARGER, PROVIDE BITUMINOUS COATED GALVANIZED RIGID
<br />RGS
<br />RIGID GALVANIZED STEEL
<br />ACCESS PANELS PROVIDED NEARBY FOR INSPECTION, TESTING AND SERVICE CONSIDERATIONS.
<br />METAL SWEEPS AND BENDS, PROVIDE BITUMINOUS COATING AROUND ALL THREADS AFTER CONDUIT ASSEMBLY.
<br />RM
<br />RTU
<br />ROOM
<br />ROOF TOP UNIT
<br />6.
<br />VERIFY CEILING TYPES AND INSTALLATION REQUIREMENTS PRIOR TO ORDERING LIGHT FIXTURES.
<br />30.
<br />EXPOSED CONDUIT BUNDLES THROUGH FLOORS, FEEDING PANELS, ETC SHALL HAVE A 4" HIGH
<br />SC
<br />SPLICE CABINET
<br />7.
<br />PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT SURFACE IN FINISHED SPACES.
<br />CONCRETE "HOUSEKEEPING" PAD INSTALLED WITH 3" COVER AROUND OUTSIDE OF CONDUITS.
<br />SC
<br />SOLID COPPER
<br />8.
<br />COORDINATE THE LOCATION OF ALL DEVICES AND BOXES WITH WINDOWS, MILLWORK, BUILT-INS, AND
<br />31.
<br />WIRE AND CONDUIT SYSTEMS ARE SHOWN DIAGRAMMATIC AND SHALL BE ROUTED TO SUIT FIELD
<br />SE
<br />SOUTH EAST
<br />CABINETS PRIOR TO ANY INSTALLATION OF CONDUITS,
<br />CONDITIONS AND EQUIPMENT LOCATIONS.
<br />SEC
<br />SECONDARY
<br />SEC
<br />SCHEDULE
<br />9.
<br />RECEPTACLES MOUNTED AT COUNTER HEIGHT SHALL BE LOCATED ABOVE BACK SPLASH WHERE POSSIBLE.
<br />32.
<br />ALL LIGHTING FIXTURES AND GENERAL PURPOSE RECEPTACLES IN MECHANICAL, ELECTRICAL AND
<br />EQUIPMENT ROOMS SHALL BE FIELD LOCATED TO SUIT EQUIPMENT CONDITIONS AND EQUIPMENT
<br />SM
<br />SINGLE MODE
<br />I0 S.
<br />10.
<br />COORDINATE THE HEIGHTS OF WALL MOUNTED LIGHTING FIXTURES TO CLEAR MIRRORS, CABINETS AND
<br />SN
<br />SOLID NEUTRAL
<br />BUILT-INS,
<br />33.
<br />ORK SHALL BE IN COMPLIANCE WITH 2O17 NEC, STATE OF WASHINGTON CODES AND REGULATIONS,
<br />nAND
<br />SPD
<br />SURGE PROTECTION DEVICE
<br />OEING STANDARDS AND SPECS.
<br />SPEC
<br />SPECIFICATION
<br />11.
<br />PROVIDE 120 VOLT, 20 AMP CIRCUIT TO FIRE ALARM PANELS AND REMOTE PANELS. CONNECT TO 20 AMP, 1
<br />SPST
<br />SINGLE POLE SINGLE THROW
<br />POLE CIRCUIT BREAKER IN LOCAL 120 VOLT POWER PANEL. LABEL CIRCUIT BREAKER ACCORDINGLY.
<br />34.
<br />WIRE AMPACITY SIZE FOR 100A CIRCUITS AND BELOW SHALL BE BASED ON NEC TABLE 310.16, 60°C
<br />PROVIDE LOCKING DEVICE ON BREAKER. LOCK BREAKER IN THE'ON' POSITION.
<br />COLUMN FOR AMPACITY. WIRE AMPACITY SIZE FOR OVER 100A SHALL BE BASED ON NEC TABLE
<br />SS
<br />STAINLESS STEEL
<br />310.16, 75°C COLUMN FOR AMPACITY.
<br />SQ
<br />SQUARE
<br />12,
<br />ALL DISCONNECTING MEANS (SWITCHES) FEEDING FAN TERMINAL BOXES SHALL BE MOTOR RATED
<br />ST
<br />SHUNT TRIP
<br />SWITCHES. MOUNT ALL DISCONNECT SWITCHES FOR MECHANICAL EQUIPMENT WITHIN SIX (6) FEET OF
<br />35.
<br />LIQUIDTIGHT FLEXIBLE METAL CONDUIT SHALL NOT BE INSTALLED WITHIN ENVIROMENTAL AIR
<br />STP
<br />SHIELDED TWISTED PAIR
<br />EQUIPMENT AS REQUIRED BY APPLICABLE CODES AND STANDARDS. LOCATIONS FOR DISCONNECT SWITCHES
<br />SPACES PER NEC 300.22(C),
<br />STIR
<br />STARTER
<br />SHOWN ON PLANS IS FOR GENERAL INFORMATION ONLY.
<br />SWBRD
<br />SWITCHBOARD
<br />36.
<br />ADJUST WIRE AND CONDUIT SIZES FOR A MAXIMUM VOLTAGE DROP OF 3% ON ALL BRANCH CIRCUITING
<br />SW
<br />SWITCH
<br />13.
<br />PROVIDE 120 VOLT, 20 AMP CIRCUIT (NORMAL POWER PANEL) TO BUILDING AUTOMATION CONTROL PANELS
<br />OVER 100'.
<br />SW
<br />SOUTH WEST
<br />FOR HVAC SYSTEM, PROVIDE LOCKING DEVICE ON BREAKER. COORDINATE LOCATION WITH HVAC CONTROLS
<br />37,
<br />ALL MAIN BREAKERS AND/OR MAIN LUG ONLY LUGS SHALL BE BOLT -ON TYPE.
<br />SWGR
<br />SWITCHGEAR
<br />SYSTEM CONTRACTOR (AND DRAWINGS/SPECIFICATIONS) PRIOR TO BID, LOCK BREAKER IN THE'ON' POSITION.
<br />SYB
<br />SYMBOL
<br />38.
<br />ALL WIRING SHALL BE #12 MINIMUM. MINIMUM CONDUIT SIZE SHALL BE 3/4".UNLESS SPECIFICALLY SHOWN OR
<br />T
<br />TRANSFORMER
<br />14.
<br />COORDINATE EXACT INSTALLATION REQUIREMENTS OF OUTLETS IN MILLWORK WITH
<br />NOTED OTHERWISE, USE TABULATION BELOW FOR EQUIPMENT SUPPLY AND OTHER SERVICE(S) WIRES
<br />ARCHITECTURAL DRAWINGS AND ACCEPTED MILLWORK SHOP DRAWINGS.
<br />WHERE WIRE SIZES ARE NOT INDICATED ON THE DRAWINGS AND/OR SPEC. WIRE SIZE SHALL BE BASED ON
<br />TBD
<br />TO BE DETERMINED
<br />UPSTREAM OCPD RATING. SIZE CONDUIT PER NEC 250.122. QUANTITIES OF WIRES SHALL BE AS REQUIRED
<br />TEL
<br />TELEPHONE
<br />15.
<br />VERIFY EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT, INCLUDING WALL SWITCHES,
<br />PER THE SERVICE CHARACTERISTICS. INCLUDE A GROUND WIRE IN EVERY CONDUIT. WIRE SIZE INDICATED
<br />TC
<br />TIME CLOCK
<br />THERMOSTATS, ETC WITH MECHANICAL CONTRACTOR AND MECHANICAL DRAWINGS,
<br />ON HOMERUN SHALL BE CARRIED THROUGH ENTIRE CIRCUIT.
<br />TMGB
<br />TELECOMMUNICATIONS MAIN GROUND BAR
<br />TS
<br />TAMPER SWITCH
<br />16,
<br />ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER TO
<br />39.
<br />REFER TO STRUCTURAL DRAWINGS FOR HIGH BAY LIGHTING FIXTURE MOUNTING REQUIREMENTS ON
<br />ARCHITECTURAL,STRUCTURAL, MECHANICAL_ AND HVAC DRAWINGS FOR GUIDANCE ON DIMENSIONS, CEILING
<br />CATWALK LEVEL.
<br />TTC
<br />TELEPHONE TERMINAL CABINET
<br />HEIGHTS, DOOR SWINGS, ROOM FINISHES, STRUCTURAL AND ARCHITECTURAL DETAILS, LOCATIONS OF
<br />TYP
<br />TYPICAL
<br />DUCTS, PIPES AND STRUCTURAL STEEL. INSTALL THE ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH
<br />40.
<br />ALL LIGHTING FIXTURE BRANCH CIRCUITS THROUGH BUILDING 40-58, SHALL BE CONTROLLED VIA THEIR RESPECTIVE
<br />TR
<br />TRANSFORMER
<br />DUCTS, PIPES, STRUCTURAL STEEL OR OTHER SYSTEMS. LOCATE LIGHTING SYMMETRICALLY IN PROPER
<br />LIGHTING CONTROL PANEL (LCP) SERVING SPACE OR ZONE,
<br />RELATION TO FINISHED AREAS EXCEPT WHERE DIMENSIONED ON THE DRAWINGS OR LOCATED ON
<br />TSP
<br />TWISTED SHEILDED PAIR
<br />REFLECTED CEILING PLANS.
<br />41.
<br />EACH LIGHTING ZONE IN THE WORK AREA SHALL HAVE (2) LOW -VOLTAGE, 2-BUTTON WALL SWITCHES. THESE SWITCHES
<br />TV
<br />TELEVISION
<br />SHALL BE MOUNTED WITHIN EACH RESPECTIVE ZON€ ALONG THE PEDESTRIAN PATHWAY AND SHALL BE TIED DIRECTLYINTO
<br />UC
<br />UNDER COUNTER
<br />17.
<br />PROVIDE ADDITIONAL SUPPORTS FOR SWITCHES, STARTERS, RACEWAYS AND OTHER ELECTRICAL
<br />THE NEAREST GE LIGHTSWEEP LIGHTING CONTROL PANEL. ONE BUTTON SHALL BE LAB€LED'OVERRIDE'. THE
<br />UG
<br />UNDERGROUND
<br />EQUIPMENT WHERE THE BUILDING STRUCTURE IS NOT SUITABLE FOR DIRECT MOUNTING.
<br />OTHER BUTTON SHALL BE LABELED'UNASSIGNED'. THE'OVERRIDE' BUTTON SHALL OVERRIDE THE HIGH BAY LIGHTING IN
<br />LICE
<br />UNDERGROUND ELECTRICAL
<br />ITS RESPECTIVE ZONE WHEN A PREPROGRAMMED LIGHTING SWEEP SHUTDOWN IS INITIATED. THE 'UNASSIGNED,
<br />18.
<br />A NUMERAL BESIDE A BRANCH CIRCUIT OUTLET ON WIRING PLANS INDICATES PANELBOARD BRANCH CIRCUIT
<br />BUTTON IS NOT USED, BUT AVAILABLE FOR FUTURE LIGHTING CONTROL OPTIONS. A SMALL PERCENTAGE OF HIGH BAY
<br />UGDB
<br />UNDERGROUND DUCT BANK
<br />CONNECTION. A LOWER CASE LETTER BESIDE AN OUTLET INDICATES THE CIRCUIT PHASE,
<br />LIGHTING WILL ALWAYS REMAIN ON FOR NIGHT LIGHT EMERGENCY USE. THESE LOW VOLTAGE MOMENTARY SWITCHES
<br />UH
<br />UNIT HEATER
<br />SHALL NOT ALLOW THE DECREASE IN LIGHT LEVELS ON THE MANUFACTURING FLOOR. MORE DETAILED PROGRAMMING
<br />LION
<br />UNLESS OTHERWISE NOTED
<br />19.
<br />SYMBOLS IN THE LEGENDS ARE APPLICABLE GENERALLY. FOR EXACT REQUIREMENTS REFER TO THE
<br />SHALL BE AVAILABLE WITHIN THE GRAPHICAL INTERFACES AND WEB INTERFACE TO ALLOW FOR 33%, 67%, 100% ON
<br />UPC
<br />ULTRA PHYSICAL CONTACT
<br />SCHEDULES, LAYOUTS, DETAILS AND SPECIFICATIONS.
<br />LIGHTING LEVEL PROGRAMMING WITHIN EACH ZONE.
<br />UPS
<br />UNINTERRUPTIBLE POWER SOURCE
<br />20.
<br />REFERENCE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ANY ELECTRICAL HAZARD CLASSIFICATION
<br />UTP
<br />UNSHIELDED TWISTED PAIR
<br />AREAS.
<br />42.
<br />COORDINATE FINAL EXIT SIGN LOCATIONS THROUGHOUT BUILDING 40-58 WITH LIFE -SAFETY DRAWINGS. ALL EXIT SIGNS
<br />V
<br />VOLTS
<br />SHALL BE CONNECTED UPSTREAM OF ANY RELAY OR MANUAL SWITCHING.
<br />VDC
<br />VOLTS, DIRECT CURRENT
<br />21.
<br />PROVIDE SEAL FITTINGS IN CONDUITS THAT ENTER HAZARDOUS AREA FROM NON -HAZARDOUS AREAS PER
<br />43.
<br />PROVIDE NYLON BUSHING ON ALL TELECOMM. CONDUIT ENDS.
<br />VERT
<br />VERTICAL
<br />NEC.
<br />VLAN
<br />VIRTUAL LOCAL AREA NETWORK
<br />44.
<br />REFER TO DISTRIBUTION BOARD PANEL SCHEDULES FOR EXACT NUMBER AND RATING OF OVERCURRENT
<br />W
<br />WIRE/WATT
<br />PROTECTION DEVICES SERVING THEIR RESPECTIVE EQUIPMENT.
<br />W/
<br />WITH
<br />45.
<br />SWITCH LEG COLOR: YELLOW/BLACK. THREE-WAY SWITCH TRAVELERS: ORANGE/BLACK.
<br />W/Q
<br />WITHOUT
<br />46.
<br />THE FOLLOWING OVERCURRENT PROTECTION DEVICES (OCPD), PHASE/NEUTRAL WIRING AND GROUND
<br />WAG
<br />WASHINGTON ADMINISTRATIVE CODE
<br />WIRING RATINGS SHALL BE USED:
<br />WAP
<br />WIRELESS ACCESS POINT
<br />WH
<br />WALL HEATER
<br />OCPD RATING MINIMUM CU WIRE SIZE MINIMUM CU WIRE SIZE
<br />WP
<br />WEATHERPROOF
<br />PHASE& NEUTRAL GROUND
<br />WW
<br />WIREWAY
<br />20A #12 #12
<br />XFMR
<br />TRANSFORMER
<br />30A #10 #10
<br />XP
<br />EXPLOSION PROOF
<br />40A #8 #10
<br />Y
<br />WYE (CONNECTED)
<br />50A #6 #10
<br />ZD
<br />ZONE DAMPER
<br />60A #4 #10
<br />70A #3 #8
<br />100A #1 #8
<br />150A #1 /0 #6
<br />200A #3/0 #6
<br />4T
<br />ALL CABLING IN OR BENEATH 1 ST FLOOR SLAB SHALL BE RATED FOR WET LOCATIONS,
<br />48.
<br />ANY VOICE/DATA DEVICE MOUNTED TO THE BOTTOM OF INACCESSIBLE CEILING SHALL HAVE A BACKBOX WITH A
<br />MINIMUM OF 1" CONDUIT ROUTED TO NEAREST CABLE TRAY OR ACCESSIBLE CEILING SPACE.
<br />BY I APPROVED I DATE
<br />ACCEPTABILITY
<br />RER
<br />THIS DESIGN AND/OR
<br />CHEC
<br />SPECIFICATION IS APPROVED
<br />RFW
<br />ENGII
<br />APPR0VED3Y
<br />DEPT.
<br />DATE
<br />DFC
<br />SUBTITLE
<br />12105/14 ABBREVIATIONS AND NOTES
<br />12/05/14
<br />12i05/14 TITLE PPP SPAR PAINT BOOTH 1 AND 2
<br />® 10.25.19
<br />SHEET
<br />IJOB NO.
<br />ELECTRICAL MASTER EVERETT, WA DWG NO.
<br />t
<br />Our difference
<br />is engineered.
<br />www.harrisgroup.com
<br />REVISION "B" ONLY
<br />PROJECT NO: 0012630.06
<br />PROJ MGR: RLT
<br />APPROVED: RLT
<br />DATE: XX.XX.XX
<br />E
<br />9.xxxx
<br />CKUIT, PafU