Laserfiche WebLink
0 <br />° ! a <br />9 � i <br />° <br />a <br />F-1 <br />EXISTING I a <br />FACTORY <br />E <br />^P�Sl <br />P ° I <br />FLOOR <br />° <br />I I I 0 i <br />I ° e <br />h ° <br />I I � <br />4 <br />s <br />a <br />° <br />EPGA <br />e I° <br />° ®M <br />° <br />� E <br />�M <br />s <br />° I M: <br />° <br />° <br />I <br />SCALE, 1/3"=V-0" <br />H-3 <br />® PAINT STORAGE <br />442SFO.L.=5 <br />2 EXITS REQUIRED <br />I <br />s <br />PAINT MIX <br />487 SF O.L. = 5 <br />2 EXITS REQUIRED <br />H-3 <br />GUN CLEANING <br />233 SF O.L.=3 <br />1 EXIT REQUIRED <br />E-1 <br />CHANGE ROOM 1 <br />128 SF O.L. =2 <br />1 EXIT REQUIRED <br />E-1 <br />® CHANGE ROOM 2 <br />123SFO.L.=2 <br />1 EXIT REQUIRED <br />AO <br />#,AINT STORAGE <br />1AZARDOUS ""'M"'LIANCE PLAN <br />SCALE: 1/0"=V-0" <br />''- -- <br />ROOM SHALL BE POSTED: <br />MAXIMUM QUANTITIES OF CLASS IB e <br />FLAMMABLE LIQUIDS SHALL NOT <br />EXCEED: <br />60 GALLONS IN OPEN USE <br />240 GALLONS IN CLOSED USE <br />UNDER 240 GALLONS CLASS IB <br />FLAMMABLE LIQUIDS TOTAL IN M <br />STORAGE AND USE ® NO VESSEL EXCEEDS 55 GALLONS <br />AGGREGATE CAPACITY OF <br />VESSELS SHALL BE UNDER 1,000 �- <br />GALLONS <br />PAINT MIX <br />HAZARDOUS COMPLIANCE PLAN <br />SCALE: 1/8"=l'-0" <br />SCALE: 1 /8"44' <br />SYM REVISION BY APPROVED DATE <br />REVISION <br />BY <br />APPROVED <br />DATE SYM <br />A <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFC W5983281 <br />HG <br />RLT <br />11.19.19 <br />B <br />PFP SPAR PAINT BOOTH 1 AND 2 - IFP W5983281 <br />HG <br />RLT <br />11.19.19 <br />AT <br />ASH <br />[IBC TABLE 307.1(1)] <br />CLASS 1B FLAMMABLE LIQUIDS <br />UNDER 60 GALLONS CLASS IB FLAMMABLE LIQUIDS IN USE OPEN SYSTEM <br />UNDER 240 GALLONS CLASS IB FLAMMABLE LIQUIDS IN USE CLOSED SYSTEM <br />UNDER 240 GALLONS IN STORAGE <br />UNDER 240 GALLONS (OPEN USE +CLOSED USE +STORAGE) <br />NO CLASS IB FLAMMABLE LIQUIDS IN USE OPEN SYSTEM <br />NO CLASS IB FLAMMABLE LIQUIDS IN USE CLOSED SYSTEM <br />UNDER 240 GALLONS IN STORAGE <br />UNDER 240 GALLONS (OPEN USE +CLOSED USE +STORAGE) <br />NO VESSEL EXCEEDS 55 GALLONS <br />AGGREGATE CAPACITY OF VESSELS UNDER 1,000 GALLONS <br />CURRENT ANTICIPATED HAZARDOUS MATERIALS QUANTITIES FOR THIS ROOM ALLOW AN F-1 <br />OCCUPANCY. BOEING HAS ELECTED TO DESIGN THE PAINT STORAGE ROOM AS AN H-3 <br />OCCUPANCY. <br />OCCUPANCY GROUP H-3 <br />ALLOW FOR OVER 240,GA.LL NS IN STORAGE <br />NO VESSEL EXCEEDS 55 GALLONS <br />AGGREGATE CAPACITY OF VESSELS UNDER 1,000 GALLONS <br />H OCCUPANCY COMPLIANCE <br />SEE GENERAL NOTES <br />HAZARDOUS MATERIALS COMPLIANCE <br />NO EXPLOSION CONTROL CONTROL REQUIRED FOR CLASS IB FLAMMABLE LIQUIDS IN STORAGE. <br />(IFC 5704.2.5, IFC 911.1, FOOTNOTE c) <br />NO SPILL CONTROL OR SECONDARY CONTAINMENT REQUIRED FOR CLASS IB FLAMMABLE <br />LIQUIDS IN STORAGE WHEN INDIVIDUAL VESSELS ARE UNDER 55 GALLONS AND AGGREGATE IS <br />UNDER 1,000 GALLONS. (IFC 5004.2) <br />2 <br />A <br />1 <br />UNDER 60 GALLONS CLASS IB FLAMMABLE LIQUIDS IN USE OPEN SYSTEM <br />UNDER 240 GALLONS CLASS IB FLAMMABLE LIQUIDS IN USE CLOSED SYSTEM <br />UNDER 240 GALLONS CLASS IB FLAMMABLE LIQUIDS TOTAL IN STORAGE AND USE <br />NO VESSEL EXCEEDS 55 GALLONS <br />AGGREGATE CAPACITY OF VESSELS UNDER 1,000 GALLONS <br />HAZARDOUS MATERIALS QUANTITIES FOR THIS ROOM ALLOW AN F-1 OCCUPANCY. BOEING <br />HAS ELECTED TO DESIGN THE PAINT STORAGE ROOM AS AN H-3 OCCUPANCY BUT MAINTAIN <br />THE LIMITS OF HAZARDOUS MATERIALS TO BELOW LIMITS SET IN IBC TABLE 307.1(1). H <br />OCCUPANCIES SHALL BE IN ACCORDANCE WITH IBC SECTION 307,415 AND THE <br />INTERNATIONAL FIRE CODE. THE DISPENSING, USE OR STORAGE OF HAZARDOUS <br />MATERIALS SHALL COMPLY WITH (IBC 414) AND THE IFC. <br />01 " enowa=11 <br />H OCCUPANCY COMPLIANCE <br />SEE GENERAL NOTES <br />HAZARDOUS MATERIALS COMPLIANCE <br />NO EXPLOSION CONTROL REQUIRED FOR CLASS IB FLAMMABLE LIQUIDS WHEN QUANTITIES <br />DO NOT EXCEED THE MAXIMUM AMOUNT PER TABLE 5003.1.1(1). IFC 5705.3.5. <br />NO SPILL CONTROL REQUIRED FOR CLASS IB FLAMMABLE LIQUIDS WHEN QUANTITIES DO <br />NOT EXCEED THE MAXIMUM AMOUNT PER TABLE 5003.1.1(1). IFC 5705.3.5. <br />NO SECONDARY CONTAINMENT REQUIRED WHEN QUANTITIES DO NOT EXCEED THE <br />MAXIMUM AMOUNT PER TABLE 5003.1.1(1). IFC 5705.3.5. <br />SEE GENERAL NOTES FOR ADDITIONAL COMPLIANCE <br />GUN CLEANING ROOM AO <br />UNDER 60 GALLONS CLASS IB FLAMMABLE LIQUIDS IN USE OPEN SYSTEM <br />UNDER 240 GALLONS CLASS IB FLAMMABLE LIQUIDS IN USE CLOSED SYSTEM <br />UNDER 240 GALLONS CLASS IB FLAMMABLE LIQUIDS IN STORAGE <br />OVER 240 GALLONS CLASS IB FLAMMABLE LIQUIDS TOTAL IN STORAGE AND USE <br />NO VESSEL EXCEEDS 55 GALLONS <br />AGGREGATE CAPACITY OF VESSELS UNDER 1,000 GALLONS <br />OCCUPANCY GROUP H-3 <br />H OCCUPANCY COMPLIANCE <br />SEE GENERAL NOTES <br />HAZARDOUS MATERIALS COMPLIANCE <br />NO EXPLOSION CONTROL, SPILL CONTROL OR CONTAINMENT REQUIRED FOR OPEN USE, <br />CLOSED USE OR STOARGE WHEN QUANTITIES UNDER IBC TABLE 307.1(1) <br />OVER 240 GALLONS IN STORAGE <br />® SPILL CONTROL NOT REQUIRED INDIVIDUAL VESSEL DOES NOT EXEED 55 GALLONS AND <br />AGGREGATE CAPACITY OF VESSELS DOES NOT EXCEED 1000 GALLONS (IFC 5004.2.1, <br />5703.4) <br />® SECONDARY CONTAINMENT NOT REQUIRED. INDIVIDUAL VESSEL DOES NOT EXCEED 55 <br />GALLONS AND AGGREGATE CAPACITY OF VESSELS DOES NOT EXCEED 1000 GALLONS (IFC <br />5004.2.2, 5703.4) <br />® EXPLOSION CONTROL NOT REQUIRED (IFC TABLE 911.1 FOOTNOTE c) <br />3 FT CLEAR SPACE BETWEEN BOOTHS AND STORAGE OR COMBUSTIBLE CONSTRUCTION. <br />BOOTHS ARE PERMITTED AGAINST WALLS. (IFC 2404.3.2.5). SEPARATED 3 FT FROM OTHER <br />OPERATIONS, MULTIPLE CONNECTED SPRAY BOOTHS SHALL NOT BE CONSIDERED "OTHER <br />OPERATIONS". (NFPA 33 SECTION 5.3) o <br />5174 <br />REGISTERED <br />ARCHITECT <br />ROBERTA L. GaFGLIANO <br />STATE OF WASHIINGTON <br />11 /21 /2019 <br />EXISTING BUILDING <br />OCCUPANCY: SPECIAL INDUSTRIAL <br />F-1 /S-1 /B/H-3 <br />TYPE OF CONSTRUCTION: TYPE IIB FULLY SPRINKLERED <br />AREA/HEIGHT/NUMBER OF STORIES: <br />ACTUAL ALLOWED <br />AREA UNLIMITED <br />1ST FLOOR 1,217,869 <br />MEZZANINE 50,848 2/3 OF FLOOR AREA OF ROOM <br />2ND MEZZANINE 94,007 <br />3RD MEZZANINE 94,007 <br />EQUIPMENT PLATFORMS MEZZ PLUS EQUIP >2/3RD OF ROOM <br />BUILDING AREA: 1,217,869 <br />FIRE AREA (1ST FLOOR PLUS MEZZANINES): 1,456,731 <br />ACTUAL ALLOWED <br />HEIGHT 11T-8" AT PARAPET UNLIMITED <br />14T-4" AT STAIR TOWER <br />NUMBER OF STORIES 1 3 <br />NUMBER OF MEZZANINES 3 3 <br />DESCRIPTION OF WORK FOR PAINT SUPPORT ROOMS <br />THIS PROJECT REMODELS 1,522 SF OF EXISTING F1 FACTORY FLOOR AREA INTO A PAINT STORAGE ROOM, <br />PAINT MIX ROOM, GUN CLEANING ROOM, AND 2 CHANGING ROOMS WITH AN EQUIPMENT PLATFORM <br />ABOVE. THE (3) PAINT ROOMS ARE AN H3 OCCUPANCY. THE OTHER ROOMS REMAIN F1 OCCUPANCY. <br />THERE IS NO CHANGE TO THE TOTAL BUILDING FLOOR AREA. TWO SPRAY ROOMS (AS DEFINED BY IFC <br />CHAPTER 24) ARE PLANNED UNDER A SEPARATE PERMIT. <br />AREA/HEIGHT/NUMBER OF STORIES: <br />EXISTING PROPOSED ALLOWED <br />AREA UNLIMITED <br />1ST FLOOR 1,217,869 NO CHANGE <br />MEZZANINE 50,848 NO CHANGE 2/3 OF FLOOR AREA OF ROOM <br />2ND MEZZANINE 94,007 NO CHANGE <br />3RD MEZZANINE 94,007 NO CHANGE <br />EQUIPMENT PLATFORMS 1,522 SF MEZZ PLUS EQUIP >2/3RD OF ROOM <br />FIRE AREA (1ST FLOOR PLUS MEZZANINES): 1,456,731 NO CHANGE <br />ALLOWABLE GROUP H AREA: <br />OCUPANCY ACTUAL ALLOWED WHEN NOT ON PERIMETER (507.8.1.1). <br />PAINT STORAGE H-3 442 1,000 <br />PAINT MIX H-3 487 500 <br />GUN CLEANING H-3 233 500 <br />CHANGE ROOM 1 F-1 (NO CHANGE) 128 <br />CHANGE ROOM 2 F-1(NO CHANGE) 123 <br />ALLOWABLE GROUP H AREA NOT LOCATED ON THE PERIMETER OF AN UNLIMITED AREA BUILDING <br />(IBC 507.8.1): <br />NOT MORE THAN 25% OF THE AREA LIMITATIONS FOR GROUP H OCCUPANCIES AS SPECIFIED <br />IN SECTION 506: <br />14,000 SF x 25% = 3,500 SF <br />TOTAL GROUP H NOT LOCATED ON PERIMETER = 1,162 SF < 3,500 SF <br />ALLOWABLE GROUP H AREA IN AN UNLIMITED AREA BUILDING (IBC 507.8.1): <br />1. NOT MORE THAN 10% OF THE AREA OF THE BUILDING <br />10%X 1,217,869=121,787 SF <br />EXISTING H3 H3 THIS PROJECT <br />911 SF + 1,162 SF = 2,073 SF < 121,787 SF <br />OR <br />2, THE AREA LIMITATIONS FOR GROUP H AS SPECIFIED IN IBC 506: <br />14,000 SF WITHOUT ALLOWED INCREASES <br />EXISTING H3 H3 THIS PROJECT <br />911 SF + 1,162 SF = 2,073 SF < 14,000 SF <br />OCCUPANCY: SPECIAL INDUSTRIAL <br />F1/H3 <br />UNLIMITED AREA BUILDING WITH GROUP H OCCUPANCY <br />ACTUAL PROPOSED ALLOWED <br />HEIGHT 147'-4" NO CHANGE UNLIMITED <br />NUMBER OF STORIES 1 NO CHANGE 3 <br />NUMBER OF MEZZANINES 3 NO CHANGE 3 <br />OCCUPANCY SEPARATION: <br />F-1/H-3: UNLIMITED AREA BUILDING (IBC 507.8.3) : 1 HR <br />SEPARATED OCCUPANCY (IBC 507.8.3) <br />SEPARATION SHALL BE A FIRE BARRIER (IBC 707.3.9) <br />SUPPORTING CONSTRUCTION SHALL BE PROTECTED (IBC 707.5.1) <br />OCCUPANT LOAD: <br />2 EXITS REQUIRED FROM H-3 OCCUPANCY WHEN OCCUPANT LOAD IS GREATER THAN 3. <br />2 EXISTS REQUIRED FROM F OCCUPANCY WHEN OCCUPANT LOAD IS GREATER THAN 49. <br />TYPE OF CONSTRUCTION: NO CHANGE <br />4 <br />AO bUALL: 'I /b 7 -U" AO <br />ACCEPTABILITY <br />DRAM <br />R, PINLAC <br />THIS DESIGN AND/OR <br />CHECKED <br />SPECIFICATION IS APPROVED <br />R, PINLAC <br />ENGINEER <br />APPROVED BY DEPT. DATE <br />R. GHIGLIANO <br />CHECKED <br />L.COSGROVE <br />APPROVED <br />R. PLUCINSKI <br />APPROVED <br />R. THIRTYACRE <br />LEGEND <br />®®®®I° EXISTING 1HRWALL OCCUPANCY SEPARATION <br />------©-- EXIT ACCESS TRAVEL DISTANCE <br />---------- COMMON PATH OF TRAVEL <br />REQUIRED EXIT <br />\ 60" DIAMETER WHEELCHAIR TURNING SPACE <br />12" DOOR SWING ENCROACHMENT <br />/ INTO WHEELCHAIR TURNING SPACE <br />36" X 48" CLEAR FLOOR SPACE <br />J SHOWER <br />30" X 48" CLEAR FLOOR SPACE <br />L-__J LAV <br />30" X 48" CLEAR FLOOR SPACE <br />®� BENCH AT WALL <br />-lII <br />L - J <br />W- -1 30" X 48" CLEAR FLOOR SPACE <br />L LOCKER <br />60" DEEP CLEAR FLOOR SPACE <br />PULL SIDE,FRONT APPROACH DOOR <br />zC <br />GENERAL NOTES <br />1. SEE 1AL10-14 FOR BUILDING LIFE SAFETY EGRESS ARANGEMENT. <br />2. MINIMUM AISLE WIDTH (IBC 1018.5): <br />36" OL IS UNDER 50 <br />44" OL IS OVER 50 <br />24" AT ACCESS TO MECHANICAL, PLUMBING OR ELECTRICAL <br />SYSTEMS OR EQUIPMENT <br />28" NONPUBLIC AISLE WHERE ADA ACCESS IS NOT <br />REQUIRED SERVING LESS THAN 50 (IBC 1018.5) <br />ADA ACCESS (IBC 1103.2.9) <br />SERVICE AREAS FREQUENTED ONLY BY SERVICE PERSONNEL FOR <br />MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT <br />ARE NOT REQUIRED TO BE ACCESSIBLE. <br />3. DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH <br />BY MORE THAN ONE-HALF. (IBC 1005.7) <br />ALLOWABLE EXIT ACCESS TRAVEL DISTANCE IN H-3 OCCUPANCY IS 150'. <br />ACTUAL WORST CASE EXIT ACCESS TRAVEL DISTANCE IS 109'. IBC <br />TABLE 1017.2 <br />5 ALLOWABLE COMMON PATH OF TRAVEL IN H-3 IS 25'. ACTUAL WORST <br />CASE COMMON PATH OF TRAVEL IS 20'. IBC TABLE 1006.2.1 <br />6 ALLOWABLE EXIT ACCESS TRAVEL DISTANCE IN AIRCRAFT <br />MANUFACTURING FACILITIES IS 1,500'. ACTUAL WORST CASE EXIT <br />ACCESS TRAVEL DISTANCE THIS PROJECT IS 123'. 166' AROUND NEW <br />PAINT ROOMS ON FACTORY FLOOR. <br />7 ALLOWABLE COMMON PATH OF TRAVEL IN F-1 IS 100'. ACTUAL WORST <br />CASE COMMON PATH OF TRAVEL IS 12'. IBC TABLE 1006.2.1. <br />FO NOT LESS THAN 25% OF THE PERIMETER WALL OF AN H-3 OCCUPANCY <br />SHALL BE AN EXTERIOR WALL EXCEPT: <br />® LIQUID USE, DISPENSING AND MIXING ROOMS NOT MORE THAN <br />500 SF <br />® LIQUID STORAGE ROOMS HAVING A FLOOR AREA OF NOT MORE <br />THAN 1,000 SF <br />9. THE TOTAL FLOOR AREA OF H OCCUPANCIES NOT LOCATED ON AN <br />EXTERIOR WALL SHALL NOT EXCEED 25% OF THE AREA LIMITATIONS <br />FOR THE H GROUP OCCUPANCY: <br />.25 x 13,000 sf = 3,250sf ALLOWED. 1,117 sf ACTUAL. <br />10. THE TOTAL FLOOR AREA OF H OCCUPANCY OF.AN UNLIMITED AREA <br />BUILDING SHALL BE LIMITED TO 10% OF THE BUILDING AREA: <br />.10 x 1,217,869 SF = 121,789 sf ALLOWED. ACTUAL H THIS PROJECT = <br />1,117 sf + EXISTING H IN PANEL PAINT = 900 sf. <br />TOTAL = 2,017 sf<l21,789 sf <br />11. SUPPORTING CONSTRUCTION AT HORIZONTAL FIRE BARRIERS <br />SEPARATING MIXED OCCUPANCIES (IBC 707.5.1, 711.2.3): <br />1) COLUMNS MUST BE INDIVIDUALLY ENCASED. (IBC704.2) <br />2) BEAMS THAT ARE PART OF THE PRIMARY STRUCTURAL FRAME <br />MAY BE PROTECTED ON EXPOSED SIDES ONLY. (IBC704.3) <br />3) MIXED OCCUPANCY REQUIRED PROTECTION = H-3/F-1 =1 HR <br />(IBC 508A). <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT (Bll <br />ISSUED <br />ffil <br />Our difference <br />is engineered. <br />www.harrisgroup.com <br />JOB NO. COMP NO. <br />11.19.19 <br />11.19.19 ARCHITECTURAL MASTER <br />W59032�1 <br />DWG NO. <br />EVERETT, WA 40-058-AO <br />11.19,19 <br />