Laserfiche WebLink
SOLID COPPER GROUND BAR WITH SNO 911 <br /> INSULATORS AND TWO 25'-0% SNOHOMISH COUNTY <br /> #2 AWG TIN COATED CONDUCTORS <br /> 911 <br /> • <br /> 1121 SE EVERETT MALL WAY <br /> PART/ BAR SIZE SUITE 20 <br /> 0 <br /> G6114412TMG8 1/4'x 4'x 12' EVERETT, WA 9 98208 <br /> 425.407.3917 <br /> GB1144161MG8 1/4'x 4'x 16' <br /> 4 GBI144207MG8 1/4-x 4'x 20• <br /> GB1144241MG8 1/4'x 4'x 24- <br /> NOTES: I <br /> 1. ALL HARDWARE STAINLESS STEEL INCLUDING BELLVILLES; COAT ALL SURFACES WITH KOPR-SHIELD BEFORE MATING. <br /> 2.FOR GROUND BOND TO STEEL ONLY: INSERT A TOOTH WASHER BETWEEN LUG AND <br /> STEEL COAT ALL SURFACES WITH KOPR-SHIELD. <br /> 3.ALL LUGS TO BE DOUBLE-LUGGED. <br /> 4.BUS BARS: MANUFACTURED BY HARGER OR EQUAL <br /> GROUND BAR SCALE: NTS 1 17 <br /> OF VVl.� <br /> Ss'0NALs4° <br /> 3 t3 it <br /> THIS DRAWING IS COPYRIGHTED AND IS THE <br /> SOLE PROPERTY OF THE OWNER. IT IS <br /> PRODUCED SOLELY FOR USE BY THE OWNER <br /> AND ITS AFFILIATES. REPRODUCTION OR USE <br /> OF THIS DRAWING AND/OR THE INFORMATION <br /> CONTAINED IN IT IS FORBIDDEN WITHOUT THE <br /> WRITTEN PERMISSION OF THE OWNER. <br /> e <br /> a <br /> �3 <br /> 2 <br /> North West <br /> 1)ALL DETAILS SHOWN IN GENERAL TERMS.ACTUAL GROUNDING INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS Tower Engineering <br /> 2)2/0 STRANDED COPPER CONDUCTOR FOR MAIN GROUND RINGS.g2 BARE TINNED COPPER FOR ALL OUTDOOR GROUNDING CONNECTIONS TO PROPOSED EQUIPMENT AND SITE — <br /> APPURTENANCES, 02 THAN INSULATED GREEN COPPER CONDUCTOR FOR ALL INTERIOR GROUNDING CONNECTIONS TO EQUIPMENT AND APPURTENANCES <br /> 3)GROUND TEST: CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT.PROVIDE INDEPENDENT TEST RESULTS TO THE CONSTRUCTION <br /> MANAGER FOR REVIEW.GROUNDING SYSTEM RESISTANCE TO EARTH GROUND SHALL NOT EXCEED 10 OHMS. <br /> 4)GROUND RING SHALL BE LOCATED A MINIMUM OF 30'BELOW GRADE OR 6'MINIMUM BELOW THE FROST LINE WHICHEVER DISTANCE IS GREATERRELEASE <br /> 5)EXTERIOR GROUNDING: PROVIDE GROUND CONDUCTORS TO EXISTING GROUND RINGS AS INDICATED ON GROUNDING PLANS.UTILITY GROUND RODS SHALL BE 5/8"x 8'-0'COPPER DATE <br /> CLAD STEEL ROOS AT SPACING SHOWN ON PLANS.PROVIDE TEST WELLS AS INDICATED. 26FEB21 PERMIT REVIEW SET <br /> 6)CONNECTIONS: ALL ABOVE-GRADE INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE-LUG COMPRESSION TYPE.ALL BELOW-GRADE AND EXPOSED EXTERIOR GROUNDING 23MAR21 BUILDING PERMIT SET <br /> CONNECTIONS TO PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE EXCEPT AS OTHERWISE INDICATED.CONNECT HVAC UNIT AND DOOR FRAME TO <br /> GROUND HALO USING STAINLESS STEEL SELF-TAPPING SCREWS WITH DOUBLE-LUG COMPRESSION CONNECTORS.VERIFY CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOW <br /> POSSIBLE GALVANIC CORROSION. <br /> 7)ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI-CORROSIVE AGENT SUCH AS'NO-OXY','NOALOX'OR'PENETROX'.VERIFY PRODUCT WITH CONSTRUCTION <br /> MANAGER.ALL BOLTS,WASHERS AND NUTS USED ON GROUND CONNECTIONS SHALL BE STAINLESS STEEL <br /> 8) CONTRACTOR TO FOLLOW EQUIPMENT MANUFACTURERS'RECOMMENDATIONS AND PRACTICES WHEN GROUNDING EACH PIECE OF EQUIPMENT.CONTRACTOR COMPLY WITH ALL <br /> STANDARDS REQUIRED FOR GROUNDING STANDARDS OF TYPE B LIGHT INDUSTRIAL OBSERVE N.E.C.AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING. <br /> 9)ALL EXPOSED GROUNDING CONDUCTORS EXCEPT INTERNAL GROUND HALO SHALL BE ROUTED IN FLEXIBLE CONDUIT.GROUND CONDUCTORS SHALL NOT MAKE CONTACT WITH ANY SITE NAME <br /> METALLIC CONDUIT OR EQUIPMENT. I�p7t1 c T� ADDITION <br /> n[ <br /> 10)ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY LICENSED ELECMCtL CONTRACTOR. NC 1 I CAMPUS ANTENNA ADDITION PROJECT <br /> GROUNDING NOTES SCALE: NONE 7 NORTH CAMPUS COMMUNICATION FACILITY <br /> SIZE AOORESS <br /> 1121 SE EVERETT MALL WAY <br /> EVERETT, WA 98208 <br /> SLEET TITLE <br /> • GROUNDING DETAILS <br /> BEET RUINER <br /> G-2 <br /> PLOT SCALE; 1:1 0 24•x36"; 1:2®11'x17• <br /> \© 1\ <br />