Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2022 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NO C405.2.4.2 Daylight zones- Indicate primary and secondary sidelit general switching <br /> C405.2.4.3 Sidelit and toplit daylight zone floor areas on plans shown-final switching <br /> by electrical <br /> I j contractor under their <br /> permit <br /> NA j Indicate toplit daylight zone floor areas on <br /> plans <br /> NA i For small vertical fenestration assemblies <br /> (rough opening less than 10 percent of j I <br /> primary daylight zone floor area)where <br /> daylight responsive controls are not required, <br /> provide fenestration area to daylight zone <br /> floor area calculation(s) <br /> NO C405.2.4 Daylight responsive Indicate on plans lighting zone(s)served by general switching <br /> controls daylight responsive controls;indicate that the shown-final switching <br /> area served by each control device does not by electrical <br /> exceeds 2,500 sf contractor under their <br /> permit <br /> NO Identify sidelit and toplit daylight zones that general switching <br /> are not provided with daylight sensing shown-final switching <br /> controls and the exception(s)that apply by electrical <br /> contractor under their <br /> permit <br /> NO C405.2.4.1.1 Daylight responsive Indicate on plans the lighting load reduction general switching <br /> controls method(continuous dimming,or stepped shown-final switching <br /> dimming that provides at least two even steps by electrical <br /> between 0%-100%of rated power) contractor under their <br /> permit ++j <br /> I ( 1 <br /> NO C405.2.4.1 Daylight responsive Indicate that daylight sensing controls are general switching <br /> controls configured to completely shut off all shown-final switching <br /> controlled lights in the lighting zone by electrical <br /> contractor under their <br /> permit <br /> NA C405.2.5 Additional controls- Identify spaces and lighting fixtures on plans <br /> Specific application that require specific application lighting <br /> lighting controls controls per this section <br /> NA C405.2.5, Display and accent Indicate on plans that manual controls are <br /> Item 1 lighting provided that control display,accent lighting <br /> and display case lighting independently from <br /> both general area lighting and other lighting <br /> applications within the same space <br /> NA Indicate manual and automatic(occupant <br /> sensor or time switch)lighting control <br /> methods <br /> C405.2.5, Hotel/motel guest Indicate method of automatic control- <br /> Item 3 rooms vacancy or captive key control of all installed <br /> luminaires and switched receptacles in auest <br /> room ! j <br /> 9 I i <br /> l � <br /> Page 3/11 <br />