Laserfiche WebLink
2 1/2" RECESS IN <br />FOR WINDOW <br />n" TVQ <br />A-51 <br />ELECTRICAL LIGHTING PLAN <br />SCALE 1/2" _ 1'-0" <br />3/4" CONDUIT ABOVE CEILING <br />1---------------- A-14 WPWR I I I I <br />ROOF TOP I I I <br />II II <br />II II <br />(I II <br />II II <br />II II <br />60 AMP NEMA3 FUSED DISCONNECT I I <br />W/ (2) 40 AMP FUSES <br />#8 AWG CU A-81,83 1 <br />II 1I <br />II II <br />II 11 <br />H II <br />II II <br />I <br />PHONE <br />E-STOP (+42" A.F.F.) <br />SUPPLIED BY OTHERS ; <br />INSTALLED BY SBS <br />INTERCOM SPEAKER <br />W/12' PIGTAIL <br />IN SOFFIT BY SBS <br />PHONE J, <br />FOR LO <br />ELECTRICAL ROOF PLAN <br />SCALE 1/2" = 1'-0" <br />�9®719 <br />L J-BOX FOR EMERGENCY PHONE <br />ELECTRICAL POWER PLAN W/ 3/4" CONDUIT TO ABOVE THE <br />CEILING AND 1/2" NIPPLE THRU WALL <br />SCALE 1/2" = 1'-0" TO THE INTERIOR WITH BUSHING <br />NOTES <br />1. TELEPHONE IN 3/4" CONDUIT TO STUB ABOVE CEILING. <br />B.E.C. TO FURNISH AND INSTALL JACKS AND <br />4-CONDUCTOR WIRE. WIRES TO BE NUMBERED PER BOX <br />AND CONTINUED INTO TELEPHONE JUNCTION BOX ON <br />EQUIPMENT WALL. <br />2. EXTERIOR LIGHTING AT THE EXIT OF BUILDING IS <br />PROVIDED BY OTHERS. <br />3. SEE SHEET A-2, A-3 FOR EXTERIOR VENEER DEPTH. <br />4. BUILDING EXTERIOR AND ROOFTOP RECEPTACLES HAVE <br />GROUND FAULT PROTECTION THROUGH GFCI BREAKERS IN <br />THE PANEL. <br />5. GC TO MAKE ELECTRICAL SERVICE CONNECTION AT <br />BUILDING ENTRY, INCLUDING MOUNTING CT, METER, AND <br />225A MAIN FUSED DISCONNECT AS REQUIRED PER LOCAL <br />CODE. <br />6. PHOTOCELL TO BE 120V, SBS TO PROVIDE (3) 16 AWG <br />WIRES (WHITE/BLACK/RED). PHOTOCELL TO BE <br />PRE -WIRED IN PANEL AT PREDESIGNATED TERMINALS. <br />7, FOR HILL PHOENIX PANELS, E-STOP WIRING TO BE <br />LANDED AT TWO TERMINALS DESIGNATED BY A LONG <br />YELLOW JUMPER WIRE. <br />3/4" CONDUIT IN <br />PARAPET WALL <br />WP J-BOX FOR PHOTOCELL <br />SUPPLIED BY OTHERS <br />INSTALLED BY SBS <br />+92" A.F.F. <br />SECTION T <br />E-1 <br />1 <br />r <br />MARKIQTY <br />r r 1 <br />® ONE R/T HVAC UNIT W/ NO.BAYHTRN108 SUPPLEMENTAL HEATER, <br />208-230V / 1P / 60HZ MCA: 36 MOP: 40 A <br />(SEE M-1 FOR MODEL DETAILS) <br />ONE PROGRAMMABLE DIGITAL THERMOSTAT <br />TCONT800AS11AA 7 DAY PPOGRAMABLE <br />3 LSI #SFP14-LED-40-UE-40 <br />40 WATT LED 1' X 4' LAY -IN FIXTURE <br />2 ROYAL PACIFIC LTD #REL20-WH 2 WATT SURFACE <br />MOUNT W/ BATTERY BACKUP <br />® ONE BROAN NO.A110 EXHAUST FAN WITH 4" DUCT (110 CFM) <br />AND FACTORY DAMPER <br />O ONE TANKLESS WATER HEATER (208V, 20A, 3.0 KW) <br />® ONE TANKLESS WATER HEATER (208V, 40A, 8.3 KW) <br />DUPLEX RECEPTACLE <br />QUAD-PLEX RECEPTACLE <br />SIMPLEX RECEPTACLE <br />DUPLEX RECEPTACLE WITH ISOLATED GROUND <br />SIMPLEX RECEPTACLE WITH ISOLATED GROUND <br />Q JUNCTION BOX <br />HORSE POWER RATED FUSED DISCONNECTED <br />TELEPHONE <br />SINGLE POLE, SINGLE THROW SWITCH <br />LIGHT <br />g FAN <br />® DUCT ALARM / REMOTE TEST STATION : H.V.A.C. <br />�T THERMOSTAT FOR H.V.A.C. <br />(S REMOTE SENSOR FOR H.V.A.C. <br />WPWR EXTRA -DUTY DIE-CAST IN -USE WEATHERPROOF COVER <br />W/ WEATHER RESISTANT RECEPTACLE <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />B.E.C. BUILDING ELECTRICAL CONTRACTOR <br />B.M. BUILDING MANUFACTURER (SBS) <br />G.C. GENERAL CONTRACTOR <br />MS MOTOR RATED MOTION SENSOR LIGHT SWITCH <br />$LO TWO POLE SINGLE THROW SWITCH (SERVICE INTERRUPT) <br />W/ RED WALL SWITCH LOCKOUT (MASTER LOCK #496B) <br />SEE SHEET SP-1 FOR ELECTRICAL NOTES <br />n9—n91 all ra—�:1 d19 <br />t1LULK-uuI nN rLUUK ruK <br />ELECTRICAL CONDUITS TO BE USED <br />BY SITE ELECTRICAL CONTRACTOR <br />SCALE 1/2" = 1'-0" <br />BLOCK -OUT IN FLOOR FOR <br />ELECTRICAL CONDUITS TO BE USED <br />BY SITE ELECTRICAL CONTRACTOR <br />THIS DRAWING IS THE PROPERTY OF <br />SAGEBRUSH BUILDING SYSTEMS OR <br />VENTAIRE, LLC AND IS NOT TO BE <br />PRINTED, PHOTOGRAPHED, COPIED, <br />LOANED OR USED WITHOUT WRITTEN <br />PERMISSION. <br />Xj <br />PIN <br />WAs <br />kffizIIST <br />iaNAL <br />Q <br />F <br />A <br />=61 <br />f� <br />Ld <br />zz <br />Q <br />00 <br />1 ' 24s <br />CD <br />N <br />co <br />cn <br />F-- <br />W <br />w <br />cn <br />Q Ln <br />w <br />Q <br />a- <br />w <br />CXD <br />N <br />U <br />CY <br />W <br />0 <br />1 i 1 <br />1 <br />Mill 1 <br />1 <br />DWG. �� <br />N0. <br />