Laserfiche WebLink
CD <br />m <br />LA <br />w <br />J <br />m <br />m <br />0 <br />I <br />I <br />WALL PHONE <br />JACK BY KIOSK <br />MANUFACTURER <br />0 <br />I <br />4" <br />TELEPHONE J-BOX <br />EJ ®X MOUNTED ABOVE CEILING <br />B° I <br />FUTURE CIRCUIT MONITORING <br />DEVICES TO BE FIELD INSTALLED <br />BY G.C. IF REQUIRED BY LOCAL <br />A.H.J. <br />® II <br />II <br />LRECEPTACLE INSTALLED <br />BY KIOSK MANUFACTURER <br />I I' <br />I I <br />I I <br />I I <br />I I <br />ELEVATION A —El <br />(2)-2" CONDUITS STUBBED 3/4" ABOVE CEILING FOR DATA <br />CABLES. INSTALL CONDUIT CLOSE TO KIOSK WALL TO ALLOW <br />FOR 4%4" RACEWAY. (BY KIOSK MANUFACTURER) <br />GALVANIZED SHROUD AT TOP <br />III _ OF CPI TO CEILING <br />I1II 00Jam— LIGHT SENSOR FURNISHED <br />3'-6°° 4" BY OWNWER INSTALLED BY <br />KIOSK MANUFACTURER <br />E EMERGENCY STOP BUTTON <br />PREFABRICATED <br />PANEL BOARD ' <br />FURNISHED BY OWNER <br />INSTALLED BY KIOSK <br />MANUFACTURER <br />CONDUITS FURNISHED <br />AND INSTALLED BY G.C. <br />WIREWAY FURNISHED <br />AND INSTALLED BY G.C. <br />BUILDING INTERIOR <br />BUILDING EXTERIOR <br />(2)-#8 & - <d� (3)-#12, 3/4" METER BOX BY G.G. <br />(1)-#1O GND CONDUIT <br />3/4" CONDUIT 3 <br />PANEL 'A' sm <br />225 AMP <br />l_'_! SERVICE ENTRANCE <br />CONDUCTORS BY G.C. <br />225A FUSED DISCONNECT <br />SWITCH BY G.C. <br />SEAL -OFFS BY G.C. <br />I l- BOND BARE COPPER GROUND BY OTHERS. <br />(4)-#4/0 THHN/THWN Cu, ALL GROUNDING SHALL COMPLY <br />(1)-0 Cu GROUND 4 - WITH ARTICLE 250 OF THE NEC. <br />(1)-#2 ISOLATED GROUND, <br />2 1/2" CONDUIT <br />1 LINE DIAGRAM INCOMING POWER <br />SCALE: N.T.S. <br />OUTSIDE LIGHTING CONTROLS <br />"LIGHTING MANAGER" - NORTH <br />MOUNT LIGHT SENSOR <br />® <br />® rB Ir--------------1 0l O. <br />r_____________ <br />I I I I <br />I I I I I <br />IL____________ <br />2-1 <br />®El <br />O <br />El <br />El 11 il® <br />® <br />® ® <br />O <br />s ealJ <br />fur �0�00 <br />tl{fX <br />°N%6t1 ] <br />°IS <br />� <br />999 <br />O <br />IA (AID IpS <br />999 909 <br />O <br />PA � 1VB � � <br />999 99@ <br />O <br />FROM TERMINAL "LP" ON DISPENSER TERMINAL STRIP <br />-CONNECT WITH #14 AWG WIRE TO CONTACTOR LUG. <br />DO NOT USE SPADE CONNECTOR. <br />FROM LIGHTING CIRCUIT BREAKER (30 AMP MAX.) <br />CON RACTOR)EL INSTALLED/WIRED BY ELECTRICAL <br />2 3 4 5 6 7 0 9 10 11 12 <br />1 N z 3 <br />30 30 <br />I I <br />I <br />L____- TO LIGHTING LOAD BY ELECTRICAL CONTRACTOR <br />TO FUSED TERMINAL "2" ON DISP. TERM. STRIP. <br />-� CONNECT WITH #14 AWG WIRE TO CONTACTOR LUG. <br />DO NOT USE SPADE CONNECTOR. <br />ON TOP OF ROOF OR <br />CANOPY WITH THE "EYE" <br />LOOKING AWAY FROM <br />SIGNS <br />OR LOT LIGHTS. <br />TERMINALS LOCATED <br />IN LIGHTING CONTROLS <br />SECTION. <br />a <br />RBRS LS LS SHD <br />II <br />I I I I I <br />I i I I 1 <br />J L_ <br />II <br />II <br />L_d L___________________ <br />J <br />F_J <br />CONTACTS FOR LIGHTING <br />REMOTE BYPASS SWITCH <br />1111110 r, r <br />SEE SHEET M-1 FOR T-STATI WIRING <br />WIRING INFORMATION COMPONENT CODE <br />FACTORY WIRING HTB HEATER TERMINAL BOARD <br />FIELD WIRING - - - - CC COMPRESSOR CONTACIOR <br />IRE COLOR CODE NOTE: <br />BL BLUE USE COPPER CONDUCTORS ONLY. <br />BK BLACK CHECK UNIT AND HEATER NAMEPLATE <br />OR ORANGE VOLTAGE FOR COMPATIBILITY. <br />Y YELLOW <br />R RED <br />BR BROWN <br />lollin <br />- WIRE TIES <br />I I <br />I CC-1 I <br />R-1 <br />CC-2 <br />BK-2 <br />I I <br />i I <br />ELECTRIC HEATER <br />Li J <br />TO POWER � <br />SUPPLY <br />IHIS DRAWING IS THE PROPERTY OF <br />SAGEBRUSH BUILDING SYSTEMS OR <br />VENTAIRE, LLC AND IS NOT TO BE <br />PRINTED, PHOTOGRAPHED, COPIED, <br />LOANED OR USED WITHOUT WRITTEN <br />PERMISSION. <br />r <br />4 <br />CD <br />v <br />fL�l <br />I <br />I <br />01 CPI PANELBOARDS. ALL ELECTRICAL EQUIPMENT SHALL BE FULLY RATED TO WITHSTAND AVAILABLE FAULT CURRENT. VERIFY <br />AVAILABLE FAULT CURRENT WITH LOCAL UTILITY COMPANY <br />ELECTRIC UTILITY METER, AS REQUIRED BY LOCAL UTILITY COMPANY. <br />3 CPI GENERAL DUTY NEMA 3R, SAFETY SWITCHES WITH NEUTRAL KIT, UL LISTED FOR SERVICE ENTRANCE, WITH CLASS T FUSES <br />SERVICE GROUND SYSTEM CONSISTING OF METAL WATER PIPING (IF AVAILABLE AT KIOSK), BUILDING STEEL, A CONCRETE -ENCASED <br />ELECTRODE, GROUND PING AND DRIVEN ELECTRODE. CONTRACTOR SHALL FURNISH AND INSTALL PER NEC 250-50. INSTALL A #2 <br />BARE COPPER WIRE FROM THE GROUND SYSTEM TO THE DISCONNECT GROUND BUSS IN A 3/4" CONDUIT. THE CONNECTION AT <br />GROUND SYSTEM SHALL BE ACCESSIBLE. THERE SHALL ALSO BE A BONDING CONNECTION FOR SERVICE GROUND BUSS TO THE METAL <br />PIPING SYSTEMS IN THE BUILDING. ISOLATED GROUND MUST NOT CONTACT COMMON GROUND SYSTEM BEFORE CONNECTION AT <br />SERVICE GROUND SYSTEM. <br />�5 U.L. LABELED ELECTRICAL CABINET ASSEMBLY, SUPPLIED BY OWNER AND INSTALLED BY KIOSK FABRICATOR PER MANUFACTURER'S <br />SPECIFICATIONS <br />�6 LIGHT SENSOR UNDER ROOF OVERHANG. CONNECT 10 PANEL BOARD ASSEMBLY PER MANUFACTURER'S SPECIFICATIONS. LOCATE SENSOR <br />TO ELIMINATE ARTIFICIAL LIGHT SOURCE CONTAMINATION <br />CONTRACTOR SHALL ENSURE THIS UTILITY TRANSFORMER IS RATED AT 208V, THREE PHASE. ANY DISCREPANCY SHALL BE <br />REPORTED TO ENGINEER PRIOR TO ANY INSTALLATION WORK <br />a NEMA 3R FUSED DISCONNECT SWITCH FOR ROOFTOP HVAC BY KIOSK SUPPLIER <br />MINIMUM CONDUCTOR SIZE TO BE (4)-#4/0, (1)-#2 GROUND AND (1)-#2 ISOLATED GROUND. <br />PANEL NOTES <br />GENERAL NOTES FOR LIGHTING CONTROLS <br />1. <br />DISPENSER ELECTRONICS, DISPENSER INTERFACE, REGISTER INTERFACE, <br />1 - OVERCURRENT PROTECTION FOR EACH LIGHTING CIRCUIT TO BE CONTROLLED <br />VEEDER ROOT AND CASH REGISTER/PUMP CONTROLLER MUST BE ON <br />BY THE LIGHTING MANAGER IS PROVIDED BY OTHERS. THIS <br />OVERCURRENT PROTECTION SHALL BE LIMITED TO 30 AMPS MAXIMUM FOR <br />2. <br />SAME PHASE. _ <br />B8 <br />CIRCUITS FOR POS REGISTER>9 "SITE SITE CONTROLLER"SHALL INCLUDE <br />EACH CIRCUIT UNLESS OTHERWISE SPECIFIED. <br />AN ISOLATED GROUND WIRE. <br />2 - CONTROL FUSE "L1" FOR LIGHTING CONTROL POWER MUST BE "5 AMPS". <br />3. <br />INSTALL EMERGENCY STOP SWITCH AT EXTERIOR OF KIOSK AS SHOWN. <br />REPLACE WITH THE SAME TYPE RATING AND FUSE. <br />4. <br />SWITCH FURNISHED WITH PANEL BOARD ASSEMBLY. <br />3 - ALL CONTACTORS CONTROLLED BY THE "LIGHTING MANAGER" SHOULD BE <br />INSTALL ITEMS WITH ASTERISK(*) AS REQUIRED, VERIFY WITH SITE PLAN. <br />WIRED INDEPENDENTLY FROM EACH CONTACTOR TO THE OUTPUT TERMINAL <br />CONTRACTOR TO CORRECT IDENTIFICATION LABELS ON PANEL SCHEDULE <br />BLOCK INTERFACE. <br />TO "SPARE" TO REFLECT CIRCUIT BREAKERS NOT USED PER SITE <br />4 - THE WIRES FROM ALL CONTACTORS MUST BE NUMBERED AT THE OUTPUT <br />CONDITIONS, CONTRACTOR SHALL NOT RELOCATE ANY CIRCUIT BREAKERS <br />TERMINAL BLOCK INTERFACE. <br />WITHOUT KROGER APPROVAL. <br />5 - THERE SHOULD ONLY BE A TOTAL OF (4) WIRES LOCATED UNDER ANY ONE <br />5. <br />THE CPI ELECTRICAL SYSTEM PROVIDES THE ABILITY TO DISCONNECT THE <br />TERMINAL BLOCK ON THE INTERFACE TERMINAL STRIP. FAILURE TO <br />DISPENSER NEUTRAL AND THE DISPENSER POWER SIMULTANEOUSLY AT <br />COMPLY TO THIS WARNING MAY CAUSE EXCESSIVE HEATING AND IMPROPER <br />THE DISPENSER MANAGER BOARD, INSTEAD OF AT THE CIRCUIT BREAKER. <br />OPERATION OF THIS LIGHTING CONTROL SYSTEM. <br />6. <br />WIRE SIZES SHOWN ARE MINIMUM. G.C. TO VERIFY REQUIREMENTS AND <br />LIGHTING CONTROL KEY NOTES <br />INSTALL WIRES PER N.E.C. VOLTAGE DROP REQUIREMENTS. <br />1. CONTACTORS ARE 4 POLE (L1,L2,L3,L4) 30 AMP MAX. PER POLE. <br />2. OPEN SPACES ON L1-L4 ARE 'SPARE'. <br />3. CIRCUIT FOR THESE CHANNELS ARE PREWIRED AND PROGRAMMABLE <br />TO BE DE -ENERGIZED BY TIME OF DAY SCHEDULE. <br />4. LIGHTING MANAGER LAYOUT IS DESIGNED FOR MAXIMUM FLEXIBILITY. <br />THE LIGHTING MANAGER IS PREWIRED FOR THE SPARES BEING USED <br />FOR SIGNAGE. HOWEVER, THE SPARES CAN EASILY BE CHANGED TO <br />ANY OTHER OF THE REMAINING FOUR FUNCTIONS, IF REQUIRED, FOR <br />SITE SPECIFIC APPLICATIONS. <br />5. REFER TO PANEL SCHEDULE FOR CIRCUITS USED. <br />ro <br />00 <br />(I n <br />LJJ <br />w <br />w <br />� <br />I <br />w <br />o <br />= <br />0 <br />L; <br />w <br />LLJI <br />w <br />w <br />clf <br />i <br />`0 <br />Q n fl <br />I <br />CD <br />- <br />DWG. �� <br />N0. <br />