Laserfiche WebLink
eQ �� SQUARE D T(PE NQOD, 225 A MLO, 1201208V, THREE PHASE, NEMA 1, ISOLATED GROUND AND EQUIPMENT BUSSES, 10,000 AIC FULLY P.ATEED. VERIFY AVAILABLE FAULT CURRENT WITH <br />LOCAL UTILITY. <br />Circuit Description Wiry VAxDF VA CB Phan CB VA I VAxI_F Wire I Description Circuit <br />1 i 2402 2402 A 0 I 0 2 <br />--- UNLEADED SUBMERSIBLE PUMP Al - <br />3 (4HP MAX} #10 2402 2402� 30 B 30 0 0 #12 SURGE SUPPRESSOR 4 <br />5 <br />_ <br />1 2402 1 2402 i �._ 0 ..,_.,.O <br />.. !UNLEADED SUBMERSIBLE PUMP #2 j ° 2402 i 2402 1 A 1 20 150 150 #12 FUEL SYSTEM MONITOR 8 <br />9 <br />1 4HP MAX)10 2402 I { X} 2402 30 1 B 1500 1 1500 INSTANTANEOUS WATER HEATER- 10 <br />11 l{USED W! 8 OR MORE DISPENSERS -__T 1 L 20 _ - #12 <br />I <br />. ) 2402 t 240� C 1500 1 1500 i RES T ROOM #1 <br />12 <br />i <br />.....«««_......, �m_..�__................_.._....._...... <br />..,....,.-._� � f <br />2402 2402 A 20 800 800 #12 ICE MERCHANDISER & ROOF RECEP T. {GFI) t4 <br />15 PREMIUM SUBMERSIBLE PUMP 4HP MAX) ... <br />{ C} #10 240� 1 2402 30 B 20 0 i 0 - 1SPARE 16 <br />_ <br />1 C 639 799 18 <br />-- — I F 20 639 � 799 #12 1611 E LIGHTS (CHANNEL 2) <br />1092 1092 A <br />19 i i <br />DIESEL SUBMERSIBLE PUMP 912 20 I I 20 <br />21 1092 1092 I B 1350 I 1688 <br />- - .... ...... _......_ ( ( I 20 #12 ICANOPY LIGHTS " CHANNEL 2 <br />22 <br />23 E 0 SUBMERSIBLE PUMP * #12 1092 �092 20 1350 �1688� I { ) 24. <br />-_� <br />25 1092 1092 A�125 156 CANOPY KIOSK SECURITY LIGHTS 26 <br />_ .. _. <br />- - <br />, #12 <br />27 SECURITYS I SYSTEM (IG) #12 240 240 1 20 B 125 150 (CHANNEL 3 �$ <br />L....... ,__ j,_-..-_.._._,._.... <br />29 SWITCHED NEUTRAL SPACE (SWN) _ 0 ._. _.a- 0 SWN I C 20 50 50 #12 !OVERFILL ALARM 30 <br />31 DISPENSER 1 - 2 (L SWN) ' 912 , i 960 G-A 20 240 240 #12 PLLD/FUELING CONTROL MODULE 32 <br />_ _.. —...._....—....... _ . _ ..._ _ , -____ ,_ ._..�,. __..-_... - a . _..... . <br />33 VENDING RECEPTACLE GFI #12 I 1100 1100 20 �_ - ._ .....__. <br />{ ) 1 20 560 700 #12 1PYLON SIGN, _ . <br />35 SWITCHED NEUTRAL SPACE (SWN) j 0 0 SWN C 20 550 700.....1.__#12 PYLON SIGNS* (CHANNEL 1) - 3Ei <br />_111_ _ _ _.._ ._ <br />37 DISPENSER 3-4 (L,SWN) #12 960 960 � 20 A � 20 � 1100 1100 #12 3$ <br />39 SPARE 1 0 0 20 B I 1600 1500 , (INSTANTANEOUS WATER HEATER- 40 <br />I 20_-- ___.l #12 <br />SWITCHED NEUTRAL SPACE {SWN) - 0 0 {._...SV�N_,__.._.__ C 1500 1500 RESTROOM #2 <br />_ <br />43 DISPENSER 5-6 (L,SWN) #12 960 960 i 20 A 20 720 900 #12 CANOPY SIGNS 44 <br />45 SPARE 0 1 0 ; 20 B 1_ 20 780 975 1 #12 {CANOPY SIGNS - (CHANNEL 1) 46 <br />-` - ...... ...... <br />47 SWITCHED NEUTRAL SPACE (SWN) - 0 1 0 1 SWN C 20 I 1100 1100 #12 48 <br />.�......_.._4 <br />49 DISPENSER 7-8 L SWN` _.._ ,.. _...__ _ _ _!_..... ..... _. <br />( f #12 960 960 20 A 1 20 1000 1000 I 412 i POS IGj ---- _.50... _ ... <br />-- _ -- ___ ___________ C... I .__. { <br />51 KIOSK LIGHTS #12 1250 1000 20 IS # 20 I 360 360 ; #12 REMOTE CONTROL SIGN BOXY _..... ,... - <br />#12 <br />.... - <br />53 SWITCHED NEU T RA SPACE (SWN) 0 �0 - SWN G 20 720 720 #12 'OFFSiTE KIOSK/GEN.RECEPTACLES 54 <br />55 _ -- _. . _ L_. __... I__ .. _ . _- r......_2. ......__ _.. ... - / <br />57 SPARE DISPENSER 9-10 {L SWN)... _ __...... #12.........{_.. �.. 060 ® z0 A 20 20 5�0 i 50 1 #12 ;SPAR KIOSKIPOS * (IG) 56 <br />_ _ ...... _ _. _ -. _.__............. . ------------------ ­­ <br />0 _... -. <br />58 <br />59 SWITCHED NEUTRAL SPACE (SWN) 0.... 0 1 SWN ' C 20 1100 I 1100 " #12 ;VENDING RECEPTACLE (GFI) 60 <br />I o <br />61 DISPENSER 11-12= (L,SWN) #12 960 960 - 20 <br />_--_-------_0 500 500 #12 ;OFFS( TIE KIOSK/POS (IG) 62 <br />63 SPARE 0 0 1 20 B I 15 j 200 200 #12 (CPI FUELING CONTROL POWER 64 <br />65 SWITCHED (NEUTRAL SPACE {SWN) - j 0 0SWN i C E 20 1100 1100 i #12 !/ENDING RECEPTACLE (GFI) -- --- 66 - <br />67 DISPENSER 13 14" L,SWIJ it <br />( ) #12 i 960 960 1 20 A j 20 0 0 t - I PARE T ( 66 <br />---------- <br />_._._..._ <br />. - --------- -- <br />69 I KIOSK RECEPTACLES EXHAUST FANS ' #12 1032 t 1032 1 20 B 2.0 1-100 1100 i 412 'VENDING RECEPTACLE (GFI) 70 <br />_ _ -. <br />71 SWITCHED NEUTRAL SPACE (SWN) - 0 0 SWN C ; 20 1100 f 1100 #12 'VENDING RECEPTACLE {GFI} 72 <br />73 DISPENSER 1516 (L,S1NN) i #12 I„ 96o I 0 ? 20 A j- - 20 960 960 #12 'SWITCHED NEUTRAL SPACE (SWN) 74 <br />_. _ - <br />75 SPARE 0..-- 0 20 i B SWN 0 O {(FUTURE) DISPENSER, 19-20° (L,SWN) 76 <br />77 SWITCHEDNEUIRAL✓PACE(SWN) 0 0 SWN C 15 __ _ _ <br />_._... _........ _-......._ .. _. �00 _200 #12 CPI LIGHTING CONTROL POWER 7E1 <br />w- .. <br />79 DISPENSER 17 18 (L,SWN) #12 960 960 20 A 20 960 _960 #12 <br />SWITCHED NEUTRAL SPACE (SWN) 80T ..._.... 81 3744 3744 € B SWN 1 0 0 Y(FUTURE) DISPENSER 21-22- (L,SWN) 82 <br />HVAC UNIT (H.A.R.C,) !#8 40 _ .. r <br />83 3744 E 3744 1 1518 1518 #12 AIR COMPR <br />0 ESSOR ! PAY PHONE (GFI)84 <br />CONNECTED LOAD TOTALS A 0 = 25724 B O = 22889 C O = 25579 OR 214 AMPS a@ 208 VOLTS, THREE PHASE <br />..... ..........__ _--------__.__ _--_..._ . ..........___.___ ___ ........ <br />DEMAND LOAD TOTALS A O = 26095 BID = 23843 C O = 25116 OR 217 AMPS @ 208 VOLTS, THREE PHASE <br />C,URRENTFRONITRANSFORMER(li)= 13000 SwA <br />WIRE TYPE = COPPER <br />'FROM <br />Trans CT <br />Disc <br />T O <br />CT Disc <br />Panel AiB <br />VTTRE SIZES( <br />i 410 <br />110 <br />RIGID (R) OR PVC (P) CONDUIT <br />P R <br />R <br />"C" VALUE = <br />16673 15082 <br />1502 <br />WIRE LEND iH <br />117 1 <br />1 <br />i NO. WIRES PER PHASE = <br />1: 1 <br />1 <br />PHASE ® <br />3 I 3 <br />3 <br />VOLT AGE = <br />I <br />208 � 208 <br />208 <br />BRANCH FROM: <br />-1 CT <br />Disc <br />DESIGN POINTS: Tram <br />CT Disc <br />Panel At <br />available current = <br />13000 73 8 <br />7358 <br />phase factor = <br />1.732 1.7:32 <br />1.7 32 <br />® <br />O..t59V�+ 0,0041 <br />. � <br />D_0D41 <br />'f— <br />M = <br />0,,5683 0,9959 <br />0,9960 <br />let through current= - 13000 <br />7388 -'- 7358 <br />7328 <br />NOTES: <br />Ground fault information shall bever€f€ed by contractor prior to construction. <br />Any discrepancy shall be reported to engineer pnorto ordering any <br />equipment or irrstwllirrg electrical service. <br />—6 1 /2" _3 3/4' <br />r-----c—.,,-----sal <br />t <br />t <br />t ' <br />20 GA. <br />t t <br />EMDOS <br />t t <br />WALL <br />f <br />EOUIPM <br />t t <br />SUPPLI <br />t t <br />t 1 <br />INSTAL, <br />i t <br />t t <br />t <br />i <br />roe------------- <br />MANAG, <br />AND Fl <br />I <br />I <br />PULL C <br />4"x4 ' <br />t <br />CA <br />b� <br />GUTTER <br />t <br />� <br />� <br />aI <br />H"JE RIOR ELEVATION <br />C3)­�_:-r-' <br />,ER'S DESK <br />1 /2"=1 '-0" <br />PANEL NOTES <br />1. DISPENSER ELECTRONICS, DISPENSER INTERFACE, REGISTER INTERFACE, TANK <br />MONITOR AND CASH REGISTER/PUMP CONTROLLER MUST BE ON SAME PHASE, <br />2. CIRCUITS FOR "POS REGISTER" AND "SITE CONTROLLER" SHALL INCLUDE AN <br />ISOLATED GROUND WIRE. <br />3. INSTALL EMERGENCY STOP SWITCH AT EXTERIOR OF KIOSK AS SHOWN, SWITCH <br />FURNISHED WITH PANEL BOARD ASSEMBLY, <br />4. INSTALL ITEMS WITH ASTERISK() AS REQUIRED, VERIFY WITH SITE AND/OR <br />FLOOR PLAN. CONTRACTOR TO CORRECT IDENTIFICATION LABELS ON PANEL <br />SCHEDULE TO "SPARE" TO REFLECT CIRCUIT BREAKERS NOT USED PER SITE <br />CONDITIONS. CONTRACTOR SHALL NOT RELOCATE ANY CIRCUIT BREAKERS <br />WITHOUT OWNER APPROVAL. <br />5. THE ELECTRICAL SYSTEM PROVIDES THE ABILITY TO DISCONNECT THE <br />DISPENSER NEUTRAL AND THE DISPENSER POWER SIMULTANEOUSLY AT THE <br />DISPENSER MAINTENANCE SWITCH, INSTEAD OF AT THE CIRCUIT BREAKER, <br />6. WIRE SIZES SHOWN ARE MINIMUM. G.C. TO VERIFY REQUIREMENTS AND INSTALL <br />WIRES PER N.E.C. VOLTAGE DROP REQUIREMENTS, <br />W.k <br />5ED <br />IRS DESK <br />1LL WIDTH <br />BUT SHELF <br />2' <br />(2)-#D & <br />CONDUIT,3/4" <br />(3)-#12, 3/4' <br />CONDUIT <br />(4)-#4/0 THHN/THWN Cu, <br />2" CONDUIT <br />40 A <br />0 <br />DISC. <br />LO <br />LO <br />(4)-#4/0 THHN/THWN Cu, <br />SEAL -OFFS #2 Cu GROUND, #2 Cu <br />ISOLATED GROUND, <br />F2 1 /2" CONDUIT <br />ONE LINE DI/`.I`RAM LEGEND <br />LOCATE CT CABINET <br />AND METER PER <br />UTILITY COMPANY <br />'YI <br />(4)-#4/0 THHN/THWN CU, <br />2" UNDERGROUND CONDUIT <br />PANELBOARD. ALL ELECTRICAL EQUIPMENT SHALL BE SERIES RATED TO WITHSTAND AVAILABLE FAULT CURRENT. <br />VERIFY AVAILABLE FAULT CURRENT WITH LOCAL UTILITY COMPANY. <br />ELECTRIC UTILITY CT CABINET AND METER, AS REQUIRED BY LOCAL UTILITY COMPANY. <br />�1 GENERAL DUTY NEMA 3R, SAFETY SWITCH WITH NEUTRAL KIT, UL LISTED FOR SERVICE ENTRANCE, WITH <br />CLASS T FUSES, <br />SERVICE GROUND SYSTEM CONSISTING OF METAL WATER PIPING (IF AVAILABLE AT KIOSK), BUILDING STEEL, <br />A CONCRETE -A TR R ENCASED ELECTRODE, GROUND RING AND DRIVEN ELECTRODE, CONTRACTOR SHALL FURNISH <br />AND INSTALL PER NEC 250-50. INSTALL A #2 BARE COPPER WIRE FROM THE GROUND SYSTEM TO THE <br />DISCONNECT GROUND BUSS IN A 3/4" CONDUIT. THE CONNECTION AT GROUND SYSTEM SHALL BE <br />ACCESSIBLE. THERE SHALL ALSO BE A BONDING CONNECTION FOR SERVICE GROUND BUSS TO THE METAL <br />PIPING SYSTEMS IN THE BUILDING. ISOLATED GROUND MUST NOT CONTACT COMMON GROUND SYSTEM <br />BEFORE CONNECTION AT SERVICE GROUND SYSTEM. <br />5 U.L. LABELED ELECTRICAL CABINET ASSEMBLY, SUPPLIED BY OWNER AND INSTALLED BY KIOSK FABRICATOR <br />PER MANUFACTURER'S SPECIFICATIONS, <br />LIGHT SENSOR UNDER ROOF OVERHANG. CONNECT TO PANEL BOARD ASSEMBLY PER MANUFACTURER'S <br />SPECIFICATIONS. LOCATE SENSOR TO ELIMINATE ARTIFICIAL LIGHT SOURCE CONTAMINATION, <br />CONTRACTOR SHALL ENSURE THIS UTILITY TRANSFORMER IS RATED AT 208V, THREE PHASE. ANY <br />DISCREPANCY SHALL BE REPORTED TO ENGINEER PRIOR TO ANY INSTALLATION WORK. <br />NEMA 3R FUSED DISCONNECT SWITCH FOR ROOFTOP HVAC BY KIOSK SUPPLIER. <br />ELECTRICAL MATERIALS LIST <br />NOT TO SCALE <br />ONE LINE DIAGRAM <br />SCALE: NOT TO SCALE <br />SECURITY CAMERA TELE <br />INSTALLED BY <br />OTHERS ---- J-80 <br />INTERSYSTEM <br />BONDING 16"x 16" <br />TERMINATION CLEAC AR SPE I <br />DEVICE <br />I RESERVED I <br />( FOR SECURITY' <br />SECURITY SYSTEM �°' PANEL <br />RECEPTACLE <br />L <br />CONDUIT <br />FOR HOOK ' <br />AND ENABLE <br />WALL PHONE I6 <br />JACK BY KIOSK <br />t� <br />MANUFACTURER �st tr <br />E <br />CABLE, AS APPROVED <br />BY OWNER - <br />3/4" CONDUIT BY KIOSK <br />MANUFACTURER TO ABOVE ROOF <br />FOR SIGN CONTROL ANTENNA <br />i E iz <br />i I °r <br />sG, <br />CONDUIT TO DESK AREA, FRONT <br />SALES, GROCERY STORE, AND <br />CANOPY SECURITY <br />MONITORING SYSTEM. INTRINSICALLY <br />SAFE APPARATUS SHALL BE <br />BONDED PER NEC 504.60 <br />INTERCOM/ETHERNET <br />REMOTE CONTROL SIGNS <br />SERVICE CONDUIT <br />(2)-2" CONDUITS STUBBED 3/4" ABOVE CEILING FOR <br />DATA CABLES. INSTALL CONDUIT CLOSE TO KIOSK WALL TO <br />ALLOW FOR 4"x4" RACEWAY. (BY KIOSK MANUFACTURER) <br />0 <br />Q <br />w UJw <br />W <br />SUBMERSIBLE PUMP VARIABLE <br />SPEED CONTROLLER (TYP.) <br />0_9i <br />U.L. LABELED <br />PANEL BOARD ASSEMBLY <br />FURNISHED WITH KIOSK--" <br />FE PETRO <br />SP rART <br />FE PETRO <br />SMART <br />CPI <br />- <br />PANEL 'A' <br />(INCLUDES LOW VOLTAGE <br />DISCONNECT) <br />FUEL <br />PANTHER <br />BOX <br />6"x6" JUNCTION BOX <br />SYSTEM <br />F <br />W/(3) 1 " CONDUITS <br />MONITOR <br />ISOLATED GROUND RECEPTACLE <br />INSTALLED BY G.C. <br />�'.. .eQ' v°d >` .. �'F °,. .. e.'n' ily Agy4 `�•Y3.e m l� lei ®�C.v^'�n�° <br />ELEVATION VIEW <br />LED PRICE <br />SIGN <br />CONTROLLER <br />BY PRICE SIGN <br />MANUFACTURER <br />EMERGENCY <br />STOP BUTTON <br />1-1/2" <br />CONDUIT FOR <br />DISPENSER <br />DATA (TWISTED <br />PAIRS) <br />- EXTERIOR LIGHT <br />_J <br />SENSO <br />R. FURNISHED <br />WITH KIOSK <br />EXTERIOR KIOSK WALL <br />W <br />04 <br />00 <br />INSTALL ALL CONDUITS AND <br />SEALOFFS PER CODE. VERIFY <br />I <br />NUMBER OF CONDUITS WITH <br />SITE CONDITIONS. CONDUITS <br />W <br />TO BE SPACED & STAGGERED <br />AT WIREWAY AS REQUIRED TO <br />ACCOMMODATE TOTAL CONDUIT <br />COUNT AND SEALOFF <br />a�°..g... CLEARANCE REQUIREMENTS. <br />W <br />VENT RISERSLL <br />- 1 " CONDUIT FROM CANOPY COLUMN (SPARE) <br />LL <br />- 2" CONDUIT FROM DISCONNECT METER <br />-- CANOPY LIGHTING AND SIGNAGE <br />- SUB PUMPS, SITE LIGHTING, SIGNAGE, <br />AIR COMPRESSOR AS REQUIRED) <br />- DISPENSER POWER AND DATA COMMUNICATION <br />— COORDINATE CONDUIT WORK <br />WITH INSTALLATION OF <br />1 KIOSK ANCHOR BOLT INTO <br />SLAB BEHIND CONDUITS. <br />000000000000000000000000OOOoOooa00000poo\ <br />0 000000000000000000000000000000000000 0 0 0) <br />- 0 <br />ALL CONDUIT THROUGH FLOOR <br />CONCRETE SLAB TO BE LOCATED IN THIS AREA <br />-- - = c e F e <br />f <br />PLAN VIEW <br />ELEC TRICAL WALL- AT KIOSK PI__AEI AND ELEVATION VIEWS <br />SCALE: 3/4"-1'-O" <br />SERVICE EQUIPMENT <br />NEUTRAL BUS <br />#6, 3/4" C TO CANOPY <br />STRUCTURAL COLUMN USE <br />ERICO CADWELD HAA1T <br />TO BOND TO COLUMN — <br />#3/0, 1"C TO STREET <br />SIDE OF WATER METER/ <br />#3/0 1 "C TO BUILDING STEEL -- <br />SERVICE GROUNDING <br />SCALE: NOT TO SCALE <br />EXTERIOR KIOSK WALL <br />INTERIOR KIOSK WALL <br />EXTENT OF CONCRETE <br />FOUNDATION <br />MAIN GROUND BAR IN <br />PRE-FAB ELECTRICAL SYSTEM <br />I - BOND CONDUIT TO GROUND <br />BAR OR TO GROUNDING <br />_ ELECTRODE CONDUCTOR; <br />MATCH SIZE OF GROUNDING <br />ELECTRODE CONDUCTOR <br />(TYP FOR METAL CONDUIT) <br />#3/0, 1 "C TO 25' OF BARE <br />#3/0 IN CONCRETE FOOTING <br />BOND CONDUIT TO GROUNDING <br />m ELECTRODE OR TO GROUNDING <br />ELECTRODE CONDUCTOR; <br />MATCH SIZE OF GROUNDING <br />ELECTRODE CONDUCTOR (TYP <br />FOR METAL CONDUIT) <br />-_ #6, 3/4"C TO GROUND ROD <br />Cq <br />04 <br />0�0�c 00 0�c 0 <br />23975t <br />AL ` <br />9/28/21 <br />�v <br />W <br />I <br />I <br />I <br />00 <br />0 <br />0 <br />I <br />I <br />I <br />>- <br />CL <br />IL <br />� <br />0- <br />CL <br />a� <br />V) <br />z <br />0 <br />V) <br />LJJ <br />z' <br />t� <br />UJ <br />iz <br />UJ <br />0 <br />m <br />(A <br />(n <br />z <br />0 <br />CC <br />Ld <br />W <br />UJ <br />D <br />UJ <br />0 <br />� <br />�a <br />Project <br />#: <br />20996 <br />Designed By: NTP <br />Drown By: NTP <br />Checked By: OV <br />Fete: 6-10-2021 <br />Scoie: <br />Disk File; <br />d <br />C) <br />0 <br />a7 <br />7 <br />co <br />c <br />s <br />.E <br />cn <br />0 <br />N <br />W <br />EVERETT, WA 98203 <br />2 <br />i <br />ELECTRICAL PANELS <br />AND DETAILS <br />a <br />_-11 r, <br />drag No.: <br />N <br />E2. 0 <br />tti <br />O <br />G <br />C-) <br />