Wiring <br />(BELOW TERMINAL STRIP) <br />FACTORY WIRING <br />FIELD WIRING ® — — — , <br />Sheet Notes <br />GENERAL <br />1 • ALL WIRING TO BE STRANDED COPPER WITH THHN/THWN INSULATION. CAUTION <br />120VAC WIRING MUST NOT BE CONNECTED TO LOW VOLTAGE CONNECTIONS. <br />DAMAGE FROM MIS --WIRING IS NOT COVERED BY WARRANTY. DAMAGE DUE TO <br />IMPROPER WIRING WILL BE BILLED BACK TO THE INSTALLING CONTRACTOR. <br />DATA CIRCUITS ARE U.L. RATED CLASS 1. ALL DATA WIRING TO BE STRANDED <br />COPPER TWISTED PAIR, <br />ETHERNET CABLES TO BE BELDEN 7928A PAIRED CATEGORY 5E DATA TUFF <br />TWISTED PAIR CABLES --CONTINUOUS, NO SPLICES. CABLES TO BE FURNISHED AND <br />INSTALLED BY CONTRACTOR, PROVIDE 2'-0" SERVICE LOOP AT DISPENSER AND <br />8'--0" SERVICE LOOP IN KIOSK. TERMINATIONS TO BE BY OWNER. <br />CONTROLLERS (TYP.)--m%={ <br />I € I i f !CONDUCTOR <br />i I 7 , <br />, <br />r� a <br />GROUNDED AT THE EQUIPMENT DEVICE TO WHICH THE CABLE IS CONNECTED <br />t ; <br />FLASH INSIDE THE KIOSK BUILDING (SEE MANUFACTURER'S INSTALLATION INSTRUCTIONS) - <br />SIGNAL .. L-y�.J y <br />. � Y <br />i i i . OFF <br />tVARIESa <br />ti a <br />2 2 GND 1/2-C, 3#14 THWN FLASH 0 AND TAPED IN A MANNER THAT WILL PREVENT CONTACT WITH ANY PART OF THE <br />iJUIPMENT OR OTHER CONDUCTORS. <br />' i sss I I { h ,� ,..etSHUNTj 2 I <br />- - RI -MOVED IF FUELING <br />SHUT-OFF DEVICE IS <br />CONNECTED <br />3#12 <br />9� <br />SJ4"C' <br />G12 <br />I w <br />GIRD. <br />�9 <br />SOLID STATE <br />_ ® o c a n SENSOR LOCATED <br />WEATHERPROOF J-BOX IN DISPENSER SUMP <br />PUMP i "MP #4Jill a_ACK SENSOR OR DISPENSER SUMP <br />HYDROSTATIC TYPICAL <br />DISPENSER <br />_- �- <br />R <br />UNLEADED EEL � � � � � � � � SUMP sENsd (1 EA PER SUMP) <br />f L SUBMERSIBLE TURBINESUBMERSIBLE TURBINE <br />FITTED SPEED \Y FE <br />® MAG-vFC" _ � (ONLY SITES WITH DIESEL) <br />SWITCHED NEUTRAL BREAKER <br />SVITTGHED o o o <br />NEUTRAL <br />® SPACE �®®BYO NEXT DiSP. e e Jillo 0 0 o IIIPROBE LOCATED <br />® I OFIN TURBINE SUMP <br />120 NAG ® �J WEATH RPR Bi.ACK -BOX <br />® L 20A asp [ TANK GAUGING <br />PUMP RELAY CONTROL BOARD TYPICAL DISPENSER BOARD DETAIL <br />WE -BOX <br />IN TURBINE SUMP <br />®� AT TANK <br />SENSOR LOCATED <br />® PLLD LINE LEAK SENSOR <br />__.._.4.., )�ER <br />SENSOR LOCATED <br />N ANNULAR SPACE <br />-BOX <br />BLACKWE <br />HYDROSTATIC LEAK <br />DETECTION SENSOR <br />INTERSTITIAL <br />E jE <br />11 q <br />(NOTE: (6)#12 WITH SOLID STATE <br />RIGHT SIDE VIEW OF DED BOARD #1 (PWR CH INPUTS] SENSOR LOCATED <br />� 3/4"G, {2)�16- � DIESEL aR E--Q) <br />Fa T� SHIELDED � AND (2)#16-TWISTED PAIR � WEATHERPROOF J-BOX IN FILL SUMP STD. LEAK DETECTION FILL <br />G I _ o o --- --. _ -- <br />_ ETHERNET FLUB � � � 13CACK � SUMP SENSOR OR <br />® INSTALLED BY OTHERS - IHYDROSTATIC SUMP SENSOR <br />BYOTHERS <br />(TYP.) [ ' (1 EA PER SUMP) <br />PANTHER IE_R BOX POS <br />INSTALLED BY INSTALLED Td FRAIaI uN-INGdN-EVd vesirc <br />N 3/4"C W/ 2j ETHERNET SOLID STATE <br />' ff I POS CONTRACTOR TANK MONITOR <br />II I R BY OTHER. z GABLES. BEER 10 NOTE 3 SENSOR LOCATED <br />®., R p O 9 ATH RPR F I WE E OO J-BOY. IN TURBINE SUMP STD. LEAK DETECTION <br />�� TURBINE SUMP SENSOR OR <br />BLACK HYDROSTATIC SUMP SENSOR <br />3/4"C. (2)#16- Lj (1 EA PER SUMP) <br />TWISTED PAIREl <br />�� n Ul <br />.._ _ - � >�a � ® Q <br />TOP VIEW OF DED BOAP,G�1 ° Ly o< + 1 ¢ U SPLICE KIT <br />Uj <br />REQUIRED (TYP.) <br />o - �� z �� Uj d�< ® w L, (SEE NOTE 1 3j <br />o - - _ <br />_ o INTERCOM W o`' < 0 m � I a m> r� 1+ U 0 <br />® �¢ <br />E f Rs.S'i{ ij I\I�.\K Q A�� �A1, ,pp, <br />m�m� m� 1 2 3 4 6 6 7 6 9101112 m0 w CLC <br />I _ <br />If t <br />I <br />- illy l I s ° 3/2. (2)1t6- <br />SHIELDED <br />DISPENSER <br />L <br />_._,,.. � r .,.,.... .._. ,...., R LEFT SIDE VIEW OF DED BOARD #1 (CH INPUTS) WAYNE <br />Typical Wayne Ovation Dispenser <br />® o o �_ GATEWAY <br />BlenderTwo Product iSide) <br />J�—3/4"C, W/(2) ETHERNET( CABLES. REFER TO NOTE 3. <br />IY <br />BlenderTwo Product <br />Sus Special l Side) <br />0 w I <br />® � Ignaro �i r <br />I <br />® = .__.... (SEE "T" SHEETS FOR DISPENSER TYPES & COUNT) ADDITIONAL DISPENSERS WIRED SIMILAR <br />TOP VIEW OF DEG BOARD #2 <br />Ifflasumm <br />®0 RR iam RR mammm RR aIS mi <br />WIRING TO BE INSTALLED BY CONTRACTOR IS SHOWN IN LEGEND, SOLID LINES <br />INDICATE MANUFACTURER INSTALLED WIRING, ONLY CRITICAL EMERGENCY AND <br />LEAK DETECTION PANEL WIRING SHOWN, <br />ALL U,G, CONDUIT TO SUBMERSIBLE PUMPS SHALL BE RIGID GALVANIZED ONLY <br />(NO EXCEPTIONS). ALL OTHER U.G. CONDUIT SHALL BE RIGID GALVANIZED OR <br />PVC SCHEDULE 40. ALL FITTINGS AND THE FINAL 24" TO ANY LOCATION SHALL <br />BE RIGID GALVANIZED. <br />THE CPI SYSTEM IS FURNISHED BY OWNER AND INSTALLED BY KIOSK <br />MANUFACTURER REFER TO THE LATEST MANUFACTURER'S INSTALLATION DETAILS <br />SUPPLIED WITH EQUIPMENT. FOR ANY VARIATIONS OF DETAILS FROM THIS <br />DRAWING, THE MANUFACTURER`S DETAILS SHALL TAKE PRECEDENCE. <br />THE CPI SYSTEM IS U.L, LISTED, D-BOX AND SUBMERSIBLE PUMP CONTROLLERS <br />ARE NOT INSTALLED IN THIS BOX. FRANKLIN--INCON-EVO CONSOLE TO BE <br />MOUNTED PER ELEVATION DETAIL DRAWING ENCLOSED IN THIS DRAWING PACKAGE. <br />FRANK[ IN <br />9, WARNING - THIS IS INTRINSICALLY SAFE WIRING AND MUST BE SEPARATED FROM <br />ALL OTHER WIRING AND INSTALLED IN CONDUIT. MAXIMUM CABLE LENGTH <br />BETWEEN MONITOR CONSOLE AND SENSORS IS 1,000 FEET. INTRINSICALLY SAFE <br />WIRING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 504--20 OF THE NEC, <br />ANSI/NFPA 70. TO MAINTAIN INTRINSIC SAFETY, PROBE/SENSOR WIRING MUST BE <br />INSTALLED WITH SEALED CONDUIT. SEE NOTE #4 THIS SHEET. <br />10. SPECIAL NOTE - IT IS THE INTENT OF THIS DESIGN THAT ANY FAILURE OF THE <br />LEAK DETECTION SYSTEM WILL RESULT IN ALL POWER TO THE PRODUCT PUMPS <br />TO BE INTERRUPTED. <br />11. CERTIFIED INSTALLERS - ALL MANUFACTURERS TRAINING REQUIREMENTS SHALL <br />BE MET BY CONTRACTOR INSTALLING SENSORS, PROBES AND WIRING TO <br />MONITORING SYSTEM, AS WELL AS ALL DISPENSER WIRING. FRANKLIN-INCON--EVO <br />REQUIRES THAT ANYONE INSTALLING FRANKLIN ELECTRICAL EQUIPMENT MUST BE <br />LEVEL I CERTIFIED. <br />12. REFER TO MANUFACTURER'S INSTALLATION MANUAL FOR ALL REQUIRED WIRING <br />CONNECTIONS. <br />13. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO NOTIFY THE <br />AUTHORIZED REPRESENTATIVE FOR EQUIPMENT STARTUP OF THE FUELING SYSTEM <br />CONTACT OWNER'S REPRESENTATIVE FOR PROGRAMMING PARAMETERS. <br />14. FRANKLIN-INCON-EVO REQUIRES THE USE OF SHIELDED GABLE IN ANY PORTION <br />OF THE WIRING BETWEEN THE PROBE/SENSOR JUNCTION BOX AND THE CONSOLE. <br />SHIELDED CABLE MUST BE RATED LESS THAN 100 PICOFARAD PER FOOT AND BE <br />MANUFACTURED WITH A MATERIAL SUITABLE FOR THE ENVIRONMENT, SUCH AS <br />CAROL (TM,) C2534 OR BELDEN (TM) 56760, 8760 OR EQUAL, BELDEN 1032A, <br />534OF1 OR 5302F1 MUST BE INSTALLED WHEN DICTATED BY LOCAL JURISDICTION. <br />15, WIRES LENGTH - IMPROPER SYSTEM OPERATION COULD RESULT IN UNDETECTED <br />POTENTIAL ENVIRONMENTAL AND HEALTH HAZARDS IF THE PROBE - OR <br />SENSOR -TO -CONSOLE WIRE RUNS EXCEED 1000 FEET. WIRE RUNS MUST BE <br />LESS THAN 1000 FEET TO BE UL ACCEPTABLE FOR THIS APPLICATION. <br />16. SPLICES - NO SPLICES BE MADE IN THE WIRE RUN BETWEEN A SENSOR OR <br />PROBE JUNCTION BOX AND THE CONSOLE. EACH SPLICE DEGRADES SIGNAL <br />STRENGTH AND COULD RESULT AN POOR SYSTEM PERFORMANCE, <br />17.CONNECT THE BARRIER GROUND TO THE EARTH GROUND BUS AT THE POWER <br />DISTRIBUTION PANEL WITH # 12 AWG (OR LARGER) CONDUCTOR. <br />18. * DENOTES FIELD WIRING CONNECTION USING FRANKLIN-INCON-EVO SEAL KITS <br />SUPPLIED WITH THE PROBE(S) AND SENSOR($). <br />19. ELEC T RICAL RATING POWER INPUT 120 VAC, 50/60 HZ, 150W MAXIMUM, <br />F E PETROL <br />20, REFERTO ELECTRICAL PANEL SCHEDULE. <br />21. CALIBRATE EACH CONTROLLER TO PROVIDE 10 G.P.M. MAXIMUM FLOW RATE AT <br />THE NEAREST DISPENSER. <br />22, NOT USED <br />CAROLINA PRODUCTS LOW VOLTAGE DISPENSER DISCONNECT <br />23. THE CAROLINA PRODUCTS LOW VOLTAGE DISPENSER DISCONNECT SYSTEM WITH <br />INTERCOM, VIDEO AND ETHERNET INCORPORATES SERVICE DISCONNECT AND <br />EMERGENCY SHUTDOWN INTO ONE SYSTEM, <br />24, THIS SYSTEM SHALL BE INSTALLED TO COMPLY WITH NEC 514,11 AND <br />NEC 514.13. <br />Barghausen <br />Consulting Engineers, Mc. <br />Kent, WA 98032 <br />425.251.6222 <br />barghausen.com <br />r <br />I <br />t x <br />d iAi <br />6 <br />j!CN000 <br />C <br />u r, <br />1m <br />I <br />00 <br />0 <br />0 <br />MEN <br />E <br />M <br />z <br />0 <br />J -- <br />0 <br />z <br />Z <br />LIJ <br />Ld <br />F_ <br />It:: <br />Uj <br />Z4 <br />Uj <br />m <br />to <br />OL <br />m <br />re <br />z <br />LJ <br />I. <br />1011 <br />Address. <br />4919 EVERGREEN WAY <br />EVERETT, WA 98203 <br />TANK AND DISPENSER <br />LEAK DETECTION WIRING <br />Hum <br />cv <br />00 <br />13 <br />c 0 <br />