Laserfiche WebLink
IAA, LLC 763.559.9100 <br />2300 Berkshire Lane N, Suite 200 www.vaaeng.com <br />Plymouth, MN 55441 <br />WA Firm Registration Nc,. 3035 <br />NOTICE: THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL '.. <br />DRAWINGS, DETAILS, DEVELOPMENTS, GRAPHICS AND MODELS THEREOF, ARE THE <br />EXCLUSIVE PROPERTY OF VAA, LLD, AND CANT BE COPIED, DUPLICATED, REPRODUCED <br />OR CONIVIERWLLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE <br />WORK SE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAR LLC. <br />DWS5 EVERETT DELIVERY STATION COPYRIGHT VAN LLC 2020 -ALL RIGHTS RESERVED. <br />SHEET <br />NUMBER SHEET NAME REV <br />M0.00 IMECHANICAL TITLE SHEET 0 <br />M0.10 CONTROL DEVICE LIST & SEQUENCES 0 <br />�M1.00 HVAC VENTILATION FLOW DIAGRAM -T 0 <br />M1.10 I FIRST FLOOR HVAC PLAN 0 <br />IM8.00 - - - MECHANICAL SPECIFICATIONS 1 0 <br />ABBREVIATIONS: <br />AFF -ABOVE FINISHED FLOOR <br />MAX - MAXIMUM <br />AG -ABOVE GROUND <br />MIN - MINIMUM <br />ATC - AIR TO CLOSE <br />MOV - MOTOR OPERATED VALVE <br />ATO - AIR TO OPEN <br />MTL - MATERIAL <br />ATM -ATMOSPHERE <br />MW - MANWAY <br />BL - BATTERY LIMIT <br />NC - NORMALLY CLOSED <br />BMS - BUILDING MANAGEMENT SYSTEM <br />NG - NATURAL GAS <br />BTL - BOTTOM TANGENT LINE <br />NIC - NOT IN CONTRACT <br />BYP - BYPASS <br />NNF - NORMALLY NO FLOW <br />CA - COMPRESSED AIR <br />NO - NORMALLY OPEN <br />CC - CHEMICAL CLEANOUT <br />NOZ - NOZZLE <br />CL - CENTERLINE <br />O/C - OPEN/CLOSE <br />CO - CLEANOUT <br />O/O - ON/OFF <br />CONN- CONNECTION <br />OP - OUTPUT <br />CSC - CAR SEAL CLOSED <br />OSBL - OUTSIDE BATTERY LIMITS <br />CSO - CAR SEAL OPEN <br />OVHD - OVERHEAD <br />CTR - CENTER <br />PLC - PROGRAMMABLE LOGIC CONTROLLER <br />CW - COLD WATER <br />PRESS -PRESSURE <br />DES - DESIGN <br />FV - PROCESS VARIABLE <br />DIA - DIAMETER <br />(R) - RELOCATED <br />DP - DESIGN PRESSURE. <br />REQD - REQUIRED <br />D/P - DIFFERENTIAL PRESSURE <br />RTD - RESISTANCE TEMP. DETECTOR <br />DRN - DRAIN <br />SC - SAMPLE CONNECTION <br />DT - DESIGN TEMPERATURE <br />SCH - SCHEDULE <br />DWG - DRAWING <br />SD - SHUTDOWN <br />(E) - EXISTING <br />SG - SPECIFIC GRAVITY <br />EL - ELEVATION <br />SIS - SAFETY INSTRUMENTED SYSTEM <br />ESD - EMERGENCY SHUTDOWN <br />SO - STEAM OUT <br />FOE - FACE OF FLANGE <br />SP - SET POINT <br />(F) - FURNISHED <br />SS - STAINLESS STEEL <br />FC - FAIL CLOSED (SPRING RETURN ACTUATOR) <br />S/S - START/STOP <br />FI - FAIL INDETERMINATE <br />STC - SPRING TO CLOSE <br />FIP - FAIL IN PLACE <br />STO = SPRING TO OPEN <br />FL - FAIL LOCKED (LAST POSITION) <br />STD - STANDARD <br />FLG - FLANGE <br />TBD - TO BE DETERMINED <br />FO - FAILED OPEN (SPRING RETURN ACTUATOR) <br />T/C - THERMOCOUPLE <br />FP - FULL PORT <br />TDH -TOTAL DIFFERENCE HEAD <br />FV - FULL VACUUM <br />TEMP - TEMPERATURE <br />GO - GEAR OPERATED <br />THRD - THREADED <br />GR - GRADE <br />TL - TANGENT LINE <br />HC - HOSE CONNECTION <br />TSO - TIGHT SHUT-OFF <br />HDR - HEADER <br />T/T - TANGENT TO TANGENT <br />HH - HAND HOLE <br />TYP - TYPICAL <br />HOA - HAND/OFF/AUTOMATIC <br />UG - UNDERGROUND <br />HP - HIGH PRESSURE <br />VF -VARIABLE FREQUENCY <br />H.P. - HIGH POINT <br />VNT - VENT <br />HW - HOT WATER <br />VAC -VACUUM <br />HWR - HOT WATER RECIRCULATION <br />VB - VORTEX BREAKER <br />IAS - INSTRUMENT AIR SUPPLY <br />W/ - WITH <br />ISBL - INSIDE BATTERY LIMITS <br />W/O - WITHOUT <br />LC - LOCKED CLOSED <br />-CONNECTION TO EXISTING <br />LO - LOCKED OPEN <br />- CENTERLINE OF EQUIPMENT <br />LP - LOW PRESSURE <br />LPT - LOW POINT <br />PIPE LINE L IATI <br />CW <br />COLD WATER <br />- m HW - m <br />HOT WATER <br />-- ---- HWR <br />HOT WATER RECIRCULATING <br />® - SAN <br />SANITARY <br />® - SAN ® <br />SANITARY UNDERGROUND <br />------V ------ <br />SANITARYVENT <br />INSULATION <br />® <br />FUTURE & EXISTING ON NEW P&IDS <br />JACKETED OR DOUBLE CONTAINMENT <br />I <br />DEMOLISHED PIPING <br />FLANGE <br />; 1t <br />CONCENTRIC (OR GENERIC) REDUCER <br />ECCENTRIC REDUCER <br />HOSE CONNECTION <br />III UNION <br />I BLIND FLANGE <br />VALVESYMBOLS: <br />GATE (OR GENERIC) GENERIC ROTARY (1/4 TURN) <br />CHECK <br />PLUG <br />STOP CHECK <br />DIAPHRAGM <br />GLOBE <br />3-WAY <br />BUTTERFLY <br />4-WAY <br />NEEDLE <br />PINCH <br />BALL <br />ZV <br />ANGLE <br />: <br />HVAC SYMBOLSABBREVIATIONS: <br />/ BRANCH DUCT TAKE -OFF <br />Ii SEE DETAIL SUPPLY AIR <br />RETURN AIR <br />TURNING VANES <br />EXHAUSTAIR <br />DUCT TEE CONNECTION <br />KF EXHAUST FAN <br />RETURN AIR DUCT <br />TAKE -OFF SEE DETAIL O O THERMOSTAT <br />CARBON MONOXIDE <br />O CARBON DIOXIDE <br />DUCT TRANSITION <br />HUMIDISTAT <br />OPPOSED BLADE VOLUME O <br />/ 7 DAMPER W/ CONCEALED O NOX SENSOR <br />CEILING DAMPER O OCCUPANCY SENSOR <br />REGULATOR <br />MANUAL BALANCING DAMPER R.A. RETURN AIR <br />S.A. SUPPLY AIR <br />DUCT MOUNTED F.A. FRESH AIR <br />SMOKE C.A. COMBUSTION AIR <br />DAMPER <br />SQUARE TO M.A. MIXED AIR <br />j ROUND F.D. FIRE DAMPER <br />TRANSITION -1 <br />� DEMOLISH <br />-U UNDERCUT <br />AIRFLOW DIRECTION �� <br />FLEX DUCT <br />EQ <br />2-1 EQUIPMENT TAG <br />PLUMBING SYMBOLS: <br />FLOOR DRAIN TOP CONNECTOR <br />IWOMNIffim <br />t�) VENT THROUGH ROOF <br />WALL HYDRANT / <br />INSIDE HOSE BIB <br />GAS SHUTOFF VALVE <br />PRESSURE REGULATOR <br />SHUTOFF VALVE <br />WAFER CHECK VALVE <br />9EQ EQUIPMENT TAG <br />x <br />BOTTOM CONNECTOR <br />DROP IN DIRECTION <br />OF FLOW <br />RISE IN DIRECTION <br />OF FLOW <br />STRAINER <br />UNION <br />- SWING CHECK VALVE <br />SUBMITTAL LOG <br />GENERAL REQUIREMENTS: <br />1. MECHANICAL CONTRACTOR SHALL SUBMIT THE FOLLOWING MINIMUM SUBMITTALS FOR THE MECHANICAL SYSTEMS ASSOCIATED WITH <br />THE MECHANICAL INSTALLATION SCOPE. <br />2. EACH SUBMITTAL SHALL HAVE A TRANSMITTAL THAT LISTS ALL MECHANICAL EQUIPMENT INCLUDED IN THE SUBMITTAL. <br />3. THE SUBMITTAL TRANSMITTAL SHALL REFERENCE THE SUBMITTAL NUMBER INDICATED BELOW. <br />DIVISION 22 SUBMITTALS: <br />SUBMITTAL NUMBER <br />i REVISION <br />SUBMITTAL ITEM <br />SUBMITTAL TO INCLUDE <br />(SEE TABLE BELOW) <br />P22-000 ---� <br />0 <br />PLUMBING PIPING SYSTEMS_ <br />1,8 <br />P22-10 <br />0 <br />( DOMESTIC WATER DISTRIBUTION PIPING <br />1,8 - <br />_ <br />P22a523 <br />0 <br />� GENERAL DUTY VALVES AND ACCESSORIES <br />1,8 -_ <br />P22-400-1 <br />0 <br />PLUMBING FIXTURES <br />1,3 <br />P22-400-2 <br />0 <br />DOMESTIC WATER HEATERS <br />1,2,3,7,9 <br />P22-503 <br />0 <br />PLUMBING PUMPS AND BOOSTER PUMP SYSTEMS <br />1,2,3,4 - <br />P22-548 <br />0 <br />SEISMIC SUPPORT AND VIBRATION ISOLATORS <br />3 <br />DIVISION 23 SUBMITTALS: <br />SUBMITTAL NUMBER <br />REVISION <br />SUBMITTAL ITEM <br />SUBMITTAL_ TO INCLUDE <br />(SEE TABLE BELOW) <br />_ <br />H23-100 <br />0 <br />HVAC DUCT MATERIALS AND FABRICATION METHODS <br />1,8 <br />H23-123-1 <br />0 <br />NATURAL GAS PIPING, FITTINGS, AND VALVES <br />11,8 <br />H23-239 <br />0 <br />HOT WATER BOILER <br />1,2,3,4,7 <br />H23-300-1 <br />0 <br />AIR DUCT ACCESSORIES <br />1 <br />H23-300-2 <br />0 <br />DIFFUSERS AND GRILLES <br />1,3 <br />H23-300-3 <br />0 <br />GRAVITY VENTILATORS <br />1,2,3 - <br />H23-300-4 <br />0 <br />LOUVERS <br />1,2,3 <br />H23-400-1 <br />0 <br />EXHAUST FANS AND SUPPLY FANS <br />1,2,3,4 <br />H23-400-2 <br />0 <br />CIRCULATION FANS <br />1,2,3,4 <br />H23-400-3 <br />0 <br />PACKAGED ROOFTOP AIR HANDLING UNITS <br />_ <br />1,2,3,4,5,6,11 <br />H23-400-4 <br />0 <br />SPLIT SYSTEM AIR HANDLING UNITS AND SPLIT SYSTEM UNITS <br />1,2,3,4,5,6 <br />H23-400-5 <br />0 <br />- <br />AIR CURTAINS WITH ELECTRIC HEATING <br />- _--- <br />1,2,3,4 <br />H23-414 <br />0 <br />AIR-COOLED CHILLERS <br />1,2,3,5,E <br />H23-500-1 <br />0 <br />GAS -FIRED HEATERS <br />1,2,3,4,7 <br />H23-500-2 <br />0 <br />BREECHING AND STACKS <br />1,2,8 <br />H23-501 <br />0 <br />VARIABLE AIR VOLUME BOXES <br />1,2,3,4,9 <br />H23-503-1 <br />0 <br />HYDRONIC PIPING SYSTEMS AND FITTINGS <br />1,8 <br />H23-503-2 <br />0 <br />HYDRONIC PUMPS <br />1,2,3,4 <br />H23-504-3 <br />0 <br />HYDRONIC PIPING ACCESSORIES (AIR ELIMINATORS, EXPANSION TANKS) <br />1,2,8 <br />H23-523 <br />0 <br />HVAC VALVES <br />1,2,8 <br />H23-548 <br />0 <br />SEISMIC SUPPORTS AND VIBRATION ISOLATORS <br />3 <br />H23-593 <br />0 <br />_ <br />TESTING, ADJUSTING, AND BALANCING REPORT <br />3 <br />H23-700-1 <br />0 <br />HVAC PIPE AND DUCT INSULATION <br />1,2,8 <br />H23-700-2 <br />0 <br />HVAC DUCT INSULATION <br />1,2,3 <br />H23-900 <br />0 <br />HVAC CONTROL SYSTEMS AND INSTRUMENTS <br />3,10 <br />SUBMITTAL INFORMATION INCLUSION LIST: <br />INCLUSION <br />NUMBER <br />INFORMATION INCLUSION <br />1 <br />DIMENSIONAL DATA <br />2 <br />EQUIPMENT WEIGHTS <br />3 <br />PERFORMANCE INFORMATION <br />4 <br />1 EQUIPMENT VOLTAGE INFORMATION <br />5 <br />FELECTRIC MOC AND MOB --- - - <br />6 <br />COOLING EER AND IEER RATINGS - <br />7 <br />NATURAL GAS CFH LOADS ---- -- - - <br />8 <br />kW LOADS - <br />9 <br />SEQUENCE OF OPERATION <br />10 <br />j SEISMIC CURB <br />11 <br />IDENTIFICATION OF OPTIONAL ACCESSORIES INCLUDED <br />ROOM DESIGN CRITERIA VENTILATION / EXHAUST RATES <br />EXHAUST AIR EXPECTED NO. OF NO. OF PROVIDED <br />EQUIPMENT# MAKEUP AIR EQUIPMENT ROOM NAME ROOM AREA, SF OCCUPANTS PER OUTDOOR AIRFLOW OCCUPANCY TYPE OCCUPANTS PER MINIMUM VENTILATION RATE MINIMUM VENTILATION PROVIDED EXHAUST I NOTES <br />PER IBC ARCHITECTURAL CODE CRITERIA PER CODE AIRLOW RATE, CFM AIRFLOW RATE, CFM RATE, CFM <br />PLANS <br />(E)EF-1 THRU (E)EF-4 (E)MAU-1 THRU (E)MAU-6 NEW PARKING BUILDING -- -- - --- S 2 -- 79,995 - - 0.75 CFM/SF2 60,000 60,000 60,000 NONE <br />DSE4_E1 <br />6611 ASSOCIATED BLVD, <br />EVERETT, WA 98203 <br />z <br />w <br />2 <br />O <br />0� <br />0. <br />2 <br />IF- <br />0 <br />IFi- <br />Z <br />wF_ <br />F.U) <br />ww <br />I> <br />0 <br />> <br />Jco <br />J <br />cy) <br />U) <br />W <br />0 <br />cl c) <br />N <br />w 00 <br />ZOUJ <br />� <br />IN� <br />F <br /><W<W <br />T-W <br />Q <br />us <br />(0 W <br />05/05/ 021 <br />SHEET TITLE <br />MECHANICAL TITLE SHEET <br />SHEET NUMBER <br />MO.00 <br />