6611 ASSOCIATED BLVD AMAZON Plans 2023-02-24
>
Address Records
>
ASSOCIATED BLVD
>
6611
>
AMAZON
>
Plans
>
6611 ASSOCIATED BLVD AMAZON Plans 2023-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2023 10:53:57 AM
Creation date
2/21/2023 8:33:39 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6611
Tenant Name
AMAZON
Permit
B2107-036
Notes
TI - TAKE OVER EXTG PODS SPACE AS INDOOR PARKING - AMAZON
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PARKING AREA VENTILATION SYSTEMS: <br />PARKING AREA MAKE UP AIR UNITS (EXISTING UNITS MAU-01 THROUGH MAU-06). <br />A. EMERGENCY SAFETY/LIMIT CONTROLS <br />1. VENTILATION UNIT INCLUDES FACTORY INSTALLED SAFETY DEVICES INCLUDING <br />NATURAL GAS, HIGH- AND LOW-PRESSURE CUTOUT SWITCHES, AND ELECTRICAL PHASE <br />MONITOR. (HEATING SYSTEMS ARE EXISTING PROJECT SCOPE IS FOR THE ADDITION OF <br />CO/NO2 SYSTEMS ONLY.) <br />B. SUPPLY AIR FLOW CONTROL <br />1. UNITS SHALL RUN CONTINUOUSLY, 24/71365. <br />2. UNDER NORMAL MODE FAN SPEED IS TO BE SET TO SUPPLY 6,000 CFM FROM EACH <br />UNIT TO THE SPACE. <br />3. UNITS HAVE A FACTORY PACKAGED TEMPERATURE CONTROL SYSTEM. <br />a. EXISTING FACTORY PACKAGED CONTROLS CONTROL ALL COMPONENTS ON <br />MAU INCLUDING GAS BURNER, SUPPLY FAN, <br />C. EXHAUST FAN CONTROL. (EXISTING UNITS EF-01 TO EF-04) <br />1, SPACE EXHAUST FANS ARE TO RUN CONTINUOUSLY, 24/7/365. <br />a. EACH EXHAUST FANS' SPEED SHALL BE SET TO EXHAUST 9,000 CFM UNDER <br />NORMAL OPERATION. <br />b. UPON CALL FOR ACTIVATION OF THE EXHAUST FANS THEIR INDIVIDUAL <br />ISOLATION DAMPERS ARE TO BE MOVED TO THEIR OPEN POSITION. <br />C. UPON PROOF THAT THE DAMPERS ARE FULLY OPEN WITH DAMPER END <br />SWITCHES EACH EXHAUST FAN IS THEN TO BE ACTIVATED. <br />d. DEACTIVATION OF EXHAUST FANS IS TO CLOSE INDIVIDUAL EXHAUST FANS <br />ISOLATION DAMPERS. <br />D. CARBON MONOXIDE (CO) / NITROGEN OXIDE (NO2) DETECTION (PROVIDE NEW DETECTION <br />SYSTEM). <br />1. SENSORS SHALL POWER AND CONTROL SIGNAL IS TO BE MONITORED BY A NEW <br />FACTORY PACKAGED CONTROL SYSTEM. <br />a. CONTROL SYSTEM SHALL BASED ON SENSOR INPUTS ACTIVATE AIR HANDLING <br />SYSTEMS AND ASSOCIATED EXHAUST FANS SERVING THE SPACE AS INDICATED <br />BY THE CONTROL SEQUENCE. <br />b. CONTROL SYSTEM IS TO BE PROVIDED TO ACCEPT ANALOG INPUTS FROM <br />SPACE SENSORS AND IS TO PROVIDE REQUIRED DIGITAL AND ANALOG OUTPUTS <br />TO HVAC EQUIPMENT. <br />2. WHEN CO SETPOINT OF 25 PPM OR NO2 SETPOINT OF 3 PPM IS EXCEEDED AT ANY <br />SENSOR IN THE ZONE ALL EXHAUST FANS ARE TO INCREASE TO 100% AIR FLOW. <br />3, MAU UNITS ARE TO INCREASE SUPPLY AIR TO THE SPACE TO 100% OUTSIDE IN AIR PURGE <br />MODE. <br />a. MAU'S ARE TO SUPPLY 6,000 CFM OF OUTSIDE AIR TO THE SPACE DURING NORMAL <br />OPERATION OF THE ROOF TOP UNITS. <br />b. MAU'S ARE TO SUPPLY 10,000 CFM OF OUTSIDE AIR TO THE SPACE DURING PURGE <br />OPERATION OF THE ROOF TOP UNIT. <br />C. EXHAUST FANS ARE TO EXHAUST 15,000 CFM EACH FROM THE SPACE. <br />4. AN ALARM INDICATION CO LEVELS ABOVE 100 PPM IS TO CALL FOR AN EVACUATION OF <br />THE SPACE. <br />5. MAU'S, THEIR CORRESPONDING EXHAUST FANS ARE TO REMAIN IN PURGE MODE AND <br />ALARMS ARE TO REMAIN IN EFFECT UNTIL THE CO/NO2 ALARM IS CLEARED. <br />FEB <br />p <br />- <br />FRO4n2mv.112 <br />E. CARBON MONOXIDE (CO) / NITROGEN OXIDE (NO2) DETECTION TESTING <br />1. INSPECT FIELD -ASSEMBLED COMPONENTS, EQUIPMENT INSTALLATION, AND ELECTRICAL <br />CONNECTIONS FOR COMPLIANCE WITH MANUFACTURER'S REQUIREMENTS. <br />2. TEST ALARM SET POINTS AND PROPER CALIBRATION OF THE (CO) CARBON MONOXIDE <br />AND NITRIC OXIDE (NO2) MONITORING SYSTEM WITH CALIBRATION GASES AND VERIFY <br />SEQUENCE OF OPERATION. <br />a. PREPARE A WRITTEN REPORT TO RECORD TEST PROCEDURES, TEST RESULTS <br />AND CORRECTIVE ACTIONS REQUIRED TO PROVIDE A FULLY FUNCTIONAL SYSTEM. <br />b. REPORT IS TO COVER THE REQUIREMENTS FOR ALL SYSTEM ACCESSORIES <br />RELAYS AND INTERLOCK BETWEEN MAKE UP AIR SYSTEMS AND EXHAUST <br />SYSTEMS. <br />G. CALIBRATION KITS SHOULD BE PROVIDED WITH THE MONITORING SYSTEM TO <br />CALIBRATE SENSORS. <br />3. REPAIR OR REPLACEMENT OF NON-FUNCTIONING SYSTEM COMPONENTS SHALL BE <br />PROVIDED AS TO PROVIDE A FULLY FUNCTIONAL MONITORING SYSTEM. <br />4. DEMONSTRATION AND TRAINING UTILIZE A FACTORY -AUTHORIZED SERVICE <br />REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, <br />TROUBLE SHOOT, CALIBRATE, AND MAINTAIN THE MONITORING SYSTEM IS TO BE <br />PROVIDED. <br />F. EMERGENCY SMOKE CONTROL <br />1. WHEN SMOKE IS DETECTED IN THE PARKING AREA ALL EXHAUST FANS AND THEIR <br />CORRESPONDING MAU(S) ARE TO BE DEACTIVATED AND THE MAU OUTSIDE AIR <br />DAMPERS ARE TO BE POSITIONED FULLY CLOSED. <br />2. THE MAU AND EXHAUST FANS ARE TO BE BROUGHT BACK ONLINE BY A MANUAL RESET <br />ONLY. <br />DEVICECONTROL <br />cb/NO2 DETECTOR GROUP <br />SERVEDFUNCTION UNIT <br />Eli NOW_ <br />SOURCE <br />A <br />DETECTOR GROUP <br />25 P. <br />COIN02 DETECTOR GROUP <br />- <br />LE <br />_ <br />COIN02 DETECTOR GROUP <br />PPM <br />_ Fail <br />25 I -I PPM <br />1100"M • <br />21 <br />CO/NO2 DETECTOR GROUP <br />#;rnqj[j2Lq='wwrA1a <br />u,'"IsiIji <br />25 PPM 3 PPM <br />CONTRACTOR <br />CO/NO2 DETECTOR GROUP <br />Mrs[ <br />25 PPM / 3 PPM <br />CO/NO2 DETECTOR GROUP <br />25 PPM / 3 PPM <br />CONTRACTOR <br />CO/NO2 DETECTOR GROUP <br />25 PPM / 3 <br />CO/NO2 DETECTOR GROUP <br />25 PPM / 3 PPM <br />L <br />ODETECTOR GROUP <br />—ME <br />,Ls. <br />25 PPM <br />e <br />CONTRACTOR <br />;,L. <br />t <br />E <br />- <br />- <br />- <br />DETECTORGROUP <br />- <br />CO/NO2 DETECTOR GROUP <br />25 PPM / 3 PPM <br />CONTRACTOR <br />VAA, LLG 763.559.9100 <br />2300 Berkshire Lane N, Suite 200 www.vaaeng.com <br />Plymouth, MN 55441 <br />WA Firm Registration No. 3035 <br />NOTICE: THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECH: <br />DP.AWINGS, DETAILS DEVELOPMENTS, GRAPHICS AND MODELS THEREOF. ARE THE <br />EXCLUSIVE PROPERTY OF VAA, LC, AND CAN'T BE COPIED, DUPLICATED, REPRODUCED <br />OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE <br />WORK BE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAq LLC. <br />V L COPYRI GHT AA. _C 2 0_0 ALL RIGHTS RESERVED. <br />DSE4_E1 <br />FaM%Zw:s'-`3's{si". "N, ,s .A'.'..ki'=` .�c'✓`x, >�3':. ?3. > �`°sT§�=.mil <br />REVISION <br />ISSUED # C m <br />05/05/201 <br />JOB NUMBER <br />205013 <br />DRAWN BY CHECKED BY <br />ASH VJD <br />8HEET TITLE <br />CONTROL DEVICE LIST & <br />SHEET NUMBER <br />Mo. 10 <br />