Laserfiche WebLink
DIVISION 23 00 00 - HEATING, VENTILATING, AIR CONDITIONING <br />SECTION 23 00 01 - CONDITIONS OF THE CONTRACT <br />1. THE GENERAL AND SUPPLEMENTARY GENERAL CONDITIONS REQUIREMENTS LISTED IN PROCUREMENT AND CONTRACT REQUIREMENTS <br />DIVISION AND GENERAL REQUIREMENTS DIVISIONS SHALL APPLY TO ALL WORK OF THIS DIVISION. <br />2. THE DRAWINGS AND GENERAL CONDITIONS, INCLUDING SUPPLEMENTARY GENERAL CONDITIONS SHALL APPLY TO ALL WORK IN DIVISION <br />23 00 00. <br />3. THE CONTRACTOR FOR THIS DIVISION SHALL REVIEW THE DRAWINGS, EXAMINE THE SITE, CHECK AS TO THE MEANS OF MAKING <br />CONNECTIONS TO SERVICES, AND SHALL BECOME FAMILIAR WITH ALL THE EXISTING CONDITIONS AND LIMITATIONS BEFORE SUBMITTING <br />A PROPOSAL. ANY APPARENT VARIANCES OF THE PLAN OR SPECIFICATION FROM THE EXISTING CONDITIONS AT THE SITE SHALL BE <br />CALLED TO THE ATTENTION OF THE ENGINEER DURING THE BID PERIOD SO THAT CLARIFICATION CAN BE MADE BY ADDENDUM. ITEMS <br />KNOWN TO BE INCONSISTENT WITH THE BID DOCUMENTS INTENT MUST BE LISTED AND QUALIFIED ON THE CONTRACTORS BID FORM. NO <br />EXTRAS WILL BE ALLOWED BECAUSE OF THE CONTRACTORS MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR HIS LACK <br />OF KNOWLEDGE OF ANY SITE CONDITIONS WHICH MAY AFFECT HIS WORK. <br />4. COORDINATION OF SCHEDULING FOR COMPLETION AND ALL INSPECTIONS OF THEIR WORK AND WORK OF SUBCONTRACTORS IS THE <br />RESPONSIBILITY OF THIS CONTRACTOR, <br />5. PLANS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER ONE SHALL BE AS BINDING AS IF CALLED FOR IN <br />BOTH. ANY ITEM OR LABOR THAT IS NECESSARY TO COMPLETE THE WORK AND IS TYPICALLY INCLUDED IN SIMILAR WORK SCOPE SHALL <br />BE FURNISHED AND INSTALLED AS PART OF THE CONTRACT WHETHER OR NOT IT IS SHOWN ON THE PLANS OR IN THE SPECIFICATIONS. <br />6, ALL PIPING, DUCTWORK AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED TO PRESENT A NEAT AND CLEAN APPEARANCE USING <br />GOOD CONSTRUCTION PRACTICES. EQUIPMENT SHALL BE INSTALLED FOR PROPER ACCESS TO OPERATE, SERVICE AND MAINTAIN THE <br />EQUIPMENT WITHOUT HAVING TO MOVE OTHER EQUIPMENT FOR ACCESS. ANY MECHANICAL EQUIPMENT (OR EXISTING EQUIPMENT TO <br />REMAIN) THAT REQUIRES ACCESS PANELS SHALL HAVE THOSE PANELS FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. <br />7. UNLESS SPECIFICALLY NOTED ON THE PLANS/SPECIFICATIONS ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND BEST QUALITY TO <br />CONFORM TO THE REQUIREMENTS OF THE OWNER, LOCAL AND STATE CODES GOVERNING THE WORK INVOLVED AND BE MADE BY <br />NATIONALLY RECOGNIZED MANUFACTURERS WITH UL LISTINGS AND LABELS. <br />8. THIS CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ANY DEFECTS WHICH MAY DEVELOP IN ANY PART OF THE SYSTEMS CAUSED BY <br />FAULTY WORKMANSHIP, MATERIAL OR EQUIPMENT, AND AGREES TO REPLACE ANY SUCH FAULTY WORKMANSHIP, MATERIAL OR <br />EQUIPMENT DURING A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF THE WORK WITHOUT COST TO OWNER. ACCEPTANCE <br />OF THE PLANT SHALL NOT WAIVE THIS GUARANTEE, WHERE THE MECHANICAL CONTRACT(S) INCLUDES AIR CONDITIONING WORK AND <br />SYSTEMS, THE GUARANTEE PERIOD SHALL START AT A.C. SYSTEM START-UP AND SHALL RUN FOR 1 FULL YEAR FROM THAT DATE, <br />SECTION 23 00 02 - GENERAL REQUIREMENTS <br />1. WORK TO BE ACCOMPLISHED ON THESE DOCUMENTS INCLUDES FURNISHING ALL LABOR, MATERIAL, EQUIPMENT AND SERVICES FOR THE <br />COMPLETION OF ALL MECHANICAL WORK <br />2. ALL PIPING, DUCTWORK AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED TO PRESENT A NEAT AND CLEAN APPEARANCE USING <br />GOOD CONSTRUCTION PRACTICES. EQUIPMENT SHALL BE INSTALLED FOR PROPER ACCESS TO OPERATE, SERVICE AND MAINTAIN THE <br />EQUIPMENT. ANY MECHANICAL EQUIPMENT (OR EXISTING EQUIPMENT TO REMAIN) THAT REQUIRES ACCESS PANELS SHALL HAVE THOSE <br />PANELS FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. <br />3. UNLESS SPECIFICALLY NOTED ON THE PLANS/SPECIFICATIONS ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND BEST QUALITY TO <br />CONFORM TO THE REQUIREMENTS OF THE LANDLORDS TENANT CRITERIA, LOCAL AND STATE CODES GOVERNING THE WORK INVOLVED <br />AND BE MADE BY NATIONALLY RECOGNIZED MANUFACTURERS WITH UL LISTINGS AND LABELS. <br />4. THIS CONTRACTOR SHALL COORDINATE WITH OTHER TRADES IN THE INS T ALLATION OF EQUIPMENT, PIPING, CONDUIT, AND DUCTWORK. <br />THE HVAC/ SHEET -METAL CONTRACTOR SHALL INITIATE THE COORDINATION PROCESS BY PROVIDING REPRODUCIBLE PLAN DRAWINGS <br />SHOWING DUCTWORK AND EQUIPMENT. THE HVAC/SHEET-METAL CONTRACTOR SHALL FORWARD THE DRAWINGS TO THE PIPING <br />CONTRACTOR, FIRE PROTECTION CONTRACTOR, AND ELECTRICAL CONTRACTOR FOR INCLUSION OF THEIR SYSTEMS WORK. THE <br />HVAC/SHEET-METAL CONTRACTOR SHALL BE RESPONSIBLE FOR RETRIEVING ALL DRAWINGS FROM NECESSARY CONTRACTORS AND <br />DEVELOPING NECESSARY DRAWINGS HIGHLIGHTING CONFLICTING AREAS. <br />5, IF A CONTRACTOR ELECTS TO PREFABRICATE PIPING AND DUCTWORK, THEY ARE STILL OBLIGATED TO ABIDE BY ALL REQUIREMENTS FOR <br />COOPERATION WITH OTHER TRADES. THEY SHALL NOT ASSUME THAT HIS MATERIAL WILL BE INSTALLED FIRST AND OTHER TRADES MUST <br />FOLLOW. IF CHANGES ARE MADE BY THE ARCHITECT/ENGINEER REASONABLY IN ADVANCE OF ANTICIPATED INSTALLATION, THE OWNER <br />SHALL NOT BE PENALIZED WITH ADDED COST BECAUSE MATERIALS WERE PREFABRICATED IN ADVANCE. <br />SECTION 23 00 03 - CODES <br />1. THIS WORK SHALL BE INSTALLED IN CONFORMITY WITH APPLICABLE LOCAL ORDINACES AND STATE STATUTES. ALL REQUIREMENTS OF <br />THE CURRENT PLUMBING CODES, HEATING AND VENTILATION CODES, ENERGY OR CONSERVATION CODES AND NFPA BULLETINS MUST BE <br />MET. STANDARDS AND SIZES WHICH MEET OR EXCEED THE ABOVE -MENTIONED REQUIREMENTS SHALL BE INSTALLED AS DRAWN OR <br />SPECIFIED. NOTHING IN THE SPECIFICATIONS OR DRAWINGS SHALL BE CONSTRUED TO PERMIT DEVIATION FROM THE REQUIREMENTS OF <br />GOVERNING CODES. <br />2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INQUIRE INTO AND COMPLY WITH ALL LOCAL ORDINANCES AND INCLUDE ANY <br />ADDITIONAL ITEMS NOT NOTED IN THE PLANS/SPECIFICATIONS IN THEIR BID. ANY CHANGES TO THE MECHANICAL SYSTEM AS REQUIRED <br />BY LOCAL, STATE OR TENANT CRITERIA THAT ARE NOT QUALIFIED ON THE CONTRACTORS BID FORM ARE ASSUMED TO BE INCLUDED IN <br />THE ORIGINAL BID AND ADDITIONAL COSTS WILL NOT BE DUE TO COMPLETE THOSE ITEMS AFTER THE CONTRACT IS ISSUED. <br />SECTION 23 00 04 - LICENSES, PERMITS, INSPECTIONS & FEES <br />1. THIS CONTRACTOR IS RESPONSIBLE FOR ALL FEES, CHARGES AND OBLIGATIONS FOR OBTAINING PERMITS AND INSPECTIONS FOR <br />PLUMBING, HEATING AND VENTILATION WORK. <br />2. ALL HVAC WORK SHALL BE INSPECTED, TESTED AND APPROVED AS REQUIRED BY GOVERNING CODES. TESTS SHALL BE MADE IN THE <br />PRESENCE OF THE PROPER INSPECTOR AND THE ARCHITECT OR THEIR AUTHORIZED REPRESENTATIVE, ALL TEST SHALL BE MADE BY <br />THE CONTRACTOR AT HIS OWN EXPENSE AND HE SHALL FURNISH THE ARCHITECT A CERTIFICATE THAT SATISFACTORY TESTS HAVE BEEN <br />MADE. <br />3. ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTIONS SHALL BE TURNED OVER TO THE OWNER AT THE COMPLETION OF THE <br />PROJECT. <br />4. THIS CONTRACTOR SHALL APPLY FOR ANY UTILITY SERVICE CHARGE, INSTALLATION OR METER AND GAUGE REQUIRED AND SHALL BE <br />RESPONSIBLE FOR THE RESPECTIVE COSTS. UPON COMPLETION OF THE PARTICULAR SECTION OF WORK THE CONTRACTOR SHALL <br />FURNISH THE OWNER WITH PROOF OF ACCEPTANCE FROM THE PROPER LOCAL OR STATE DEPARTMENT HAVING JURISDICTION. <br />SECTION 23 00 05 - TRADE NAIVES, MANUFACTURERS AND SHOP DRAWINGS <br />1. IN ANY CASE WHERE A SPECIFIC NAME OF EQUIPMENT OR MATERIAL IS MENTIONED ON THE DRAWINGS OR SPECIFICATIONS THE EXACT <br />EQUIPMENT SHALL BE USED FOR THE BASE BID. EQUIPMENT OF EQUAL GRADE AND QUALITY WILL BE SUBJECT TO PRIOR APPROVAL BY <br />THE GENERAL CONTRACTOR PROJECT MANAGER AND THE ENGINEER IN WRITING THRU THE SHOP DRAWING SUBMITTAL PROCESS. ANY <br />EQUIPMENT INSTALLED WITHOUT WRITTEN APPROVAL WILL BE CHANGED OUT TO THE SPECIFIED EQUIPMENT AT THE CONTRACTORS <br />EXPENSE. <br />2, MECHANICAL CONTRACTOR SHALL SUBMIT 3 COPIES OF SHOP DRAWINGS TO THE GENERAL CONTRACTOR PROJECT MANAGER FOR <br />APPROVAL. IF APPROVED, COPSES WILL BE STAMPED "REVIEWED" OR "REVIEWED WITH COMMENTS" AND WILL BE RETURNED TO THE <br />CONTRACTOR. IF NOTATIONS AND MARKS INDICATE THAT REVISED INFORMATION IS REQUIRED, THEN CORRECTED INFORMATION SHALL <br />BE SUBMITTED. <br />3. IF NOTATIONS AND MARKS INDICATE THAT REVISED INFORMATION IS REQUIRED BEFORE SHOP FABRICATIONS (OR OTHER WORK <br />REPRESENTED) CAN PROCEED, REVISED OR CORRECTED INFORMATION SHALL BE SUBMITTED. <br />4. SHOP DRAWINGS SHALL BE PACKAGED TO INCLUDE ALL MATCHING EQUIPMENT OF THE SAME TAGGING/IDENTIFICATION. DO NOT SUBMIT <br />DIFFERENT EQUIPMENT WITH IN ONE SUBMITTAL. PROVIDE SHOP DRAWING WITH ALL SCHEDULED PARAMETERS, NOTES/ SPECIFICATION <br />REQUIREMENTS. <br />5. THIS CONTRACTOR SHALL FURNISH THE OWNER COMPLETE CATALOG DATA, MANUFACTURER'S LITERATURE AND DETAILED MANUALS <br />COVERING THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT SPECIFIED UNDER THIS SECTION IN TWO (2) COPIES OF HARD BOUND <br />BOOKLET MATERIAL. THE LITERATURE SHALL BE GIVEN TO THE OWNER'S OPERATOR WITH EXPLANATION AT THE TIME OF OWNER'S TAKE- <br />OVER OF THE BUILDING <br />SECTION 23 00 06 - INTRA-CONTRACT BOUNDARIES <br />1. COOLING COIL DRAIN PANS AND DRAINS FROM ALL VENTILATION OPENINGS THRU ROOF OR WALL SHALL BE PIPED BY PLUMBING <br />CONTRACTOR.. FOR PLUMBING EQUIPMENT WHICH IS SPECIFIED UNDER SEPARATE SECTIONS THE PLUMBING CONTRACTOR WILL BE <br />REQUIRED TO FURNISH AND INSTALL THE NECESSARY "P" TRAPS, STOP VALVES ECT. INCLUDING ROUGH -IN AND FINAL CONNECTIONS. <br />2. NATURAL GAS PIPING TO ALL MECHANICAL AND PLUMBING EQUIPMENT SHALL BE PIPED BY THE PLUMBING CONTRACTOR. THE <br />MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY SHUT-OFF VALVES, REGULATORS, BACKPRESSURE RELIEF <br />VALVES, AND COUPLINGS AND THE PLUMBING CONTRACTOR SHALL MAKE THE FINAL CONNECTIONS TO ALL MECHANICAL EQUIPMENT. <br />FOR PLUMBING EQUIPMENT WHICH IS SPECIFIED UNDER SEPARATE SECTIONS THE PLUMBING CONTRACTOR WILL BE REQUIRED TO <br />FURNISH ALL -NATURAL GAS ACCESSORIES. <br />SECTION 23 00 07 - ELECTRICAL SERVICE, WIRING AND CONNECTIONS <br />1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE TO ALL MOTORS AND OTHER MECHANICAL EQUIPMENT (UNLESS <br />OTHERWISE NOTED) IN CONFORMANCE WITH ELECTRICAL DIVISIONOF THE SPECIFICATIONS. <br />2. ALL WIRING FOR THE CONTROL OF MECHANICAL MOTORS AND EQUIPMENT SHALL BE FURNISHED COMPLETE BY THE MECHANICAL <br />CONTRACTOR INCLUDING BUT NOT LIMITED TO WIRING; CONDUIT, DEVICES AND INSTALLATION BY A LICENSED SUBCONTRACTOR <br />UTILIZING ELECTRICIANS EXPERIENCE IN THE TYPE OF SYSTEMS TO BE INSTALLED. <br />3. DIELECTRIC FITTINGS <br />A. COMBINATION FITTING OF COPPER ALLOY AND FERROUS MATERIALS WITH THREADED, SOLDER -JOINT, PLAIN, OR WELD -NECK END <br />CONNECTIONS THAT MATCH PIPING SYSTEM MATERIALS. <br />B. PROVIDE UNION, FLANGE, COUPLING OR NIPPLE AS NECESSARY AT LOCATION OF DISSIMILAR METAL MATERIAL. <br />SECTION 23 00 08 - GUARANTEE <br />1. THIS CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR AND DEFECTS WHICH MAY DEVELOP IN ANY PART OF THE SYSTEMS CAUSED BY <br />FAULTY WORKMANSHIP, MATERIAL OR EQUIPMENT; AND AGREES TO REPLACE ANY SUCH FAULTY WORKMANSHIP, MATERIAL OR <br />EQUIPMENT DURING A PERIOD OF 12 MONTHS FROM THE DATE OF FINAL ACCEPTANCE WITHOUT ANY COST TO THE OWNER. ANY <br />EXTENDED WARRANTIES (LONGER THAN 12 MONTHS) FOR EQUIPMENT WILL BE NOTED ON THE SCHEDULES, PLANS OR SPECIFICATIONS. <br />2. EACH PIECE OF EQUIPMENT FURNISHED BY THE CONTRACTOR SHALL HAVE A 12 MONTH WARRANTY FOR MATERIAL AND LABOR AT <br />STARTS UPON THE DATE OF FINAL ACCEPTANCE AS DESIGNATED BY THE GENERAL CONTRACTOR PROJECT MANAGER. ALL COSTS FOR <br />THE WARRANTY (MATERIAL AND LABOR) SHALL BE INCLUDED IN THE ORIGINAL BID. <br />SECTION 23 00 09 - RECORD DRAWINGS <br />1. THIS CONTRACTOR SHALL MAINTAIN AT THE JOB SITE A SET OF DRAWINGS TO BE USED SPECIFICALLY FOR RECORDING CHANGES FROM <br />THE CONTRACT DOCUMENTS. THE INFORMATION SUCH AS VALVES, DUCT AND PIPE DEVIATIONS SHOULD BE DIMENSIONED FROM EASILY <br />RECOGNIZABLE REFERENCE POINTS INDICATING BOTH HORIZONTAL AND VERTICAL DISTANCES. <br />2. THE CONTRACTOR SHALL SUBMIT A FINAL SIGNED SET OF AS -BUILT DRAWINGS TO THE OWNER AT THE COMPLETION OF THE PROJECT. <br />3. THE CONTRACTOR SHALL SUBMIT TO THE OWNER AT THE END OF THE PROJECT (2) COMPLETE HARD BOUND SET OF CATALOG DATA, <br />MANUFACTURERS LITERATURE, DETAIL MANUALS COVERING THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT SPECIFIED, <br />SECTION 23 0010 - DISCREPANCIES IN DOCUMENTS <br />1. THE DRAWINGS OF PIPING AND DUCTWORK SYSTEMS SHALL BE INSTALLED SUBSTANTIALLY AS SHOWN ON THE PLANS. THE EXACT <br />POSITION OF EACH AND EVERY PIPE, DUCT, OFFSET AND TRANSITION CANNOT BE GIVEN BY SCALING THE DRAWINGS BUT SHALL IN EVERY <br />CASE BE PLACED SO AS TO AVOID INTERFERENCE WITH OTHER WORK. ALL NECESSARY CHANGES IN THE LOCATION OF PIPE OR <br />DUCTWORK FOR ITS PROPER INSTALLATION AND TO AVOID CONFLICT WITH OTHER TRADES SHALL BE DONE BY THE CONTRACTOR AT NO <br />ADDITIONAL CHARGE. <br />SECTION 23 0011 - DEMOLITION <br />1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION <br />PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE <br />LEFT INTACT. <br />2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING PIPING, <br />HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, <br />UNLESS SPECIFICALLY NOTED OTHERWISE. <br />3. CONTRACTORS MUST VERIFY WITH OWNER ALL EXISTING ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO <br />REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT <br />APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOFIWALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. <br />4. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE <br />CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. <br />5. IF REQUIRED BY OWNER OR CODES, ABANDONED PIPING AND/OR DUCTWORK MUST BE REMOVED 10 POINT OF ORIGIN. CONFIRM THE <br />EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL <br />CONTRACTOR. <br />6. PROVIDE A RECYCLED MATERIALS REPORT TO THE LANDLORD PRIOR TO SUBSTANTIAL COMPLETION. <br />SECTION 23 0012 - INSTRUCTIONS TO OWNER <br />1. ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERA I E, AND <br />MAINTAIN ALL EQUIPMENT FURNISHED AND INSTALLED BY MECHANICAL. REFER TO DIVISION 1 SECTION "DEMONSTRATION AND <br />TRAINING." <br />2 THE CONTRACTOR SHALL ALSO SUPERVISE THE INITIAL OPERATION OF ALL EQUIPMENT AND INSTRUCT THE OPERATOR SELECTED BY THE <br />OWNER IN SUCH OPERATION AS REQUIRED TO ACQUAINT HIM THOROUGHLY WITH THE BEST PRACTICE. <br />SECTION 23 0013 - CUTTING AND PATCHING <br />1. THIS CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF HIS EQUIPMENT IN THE BUILDING <br />WALLS, PARTITIONS, FLOORS, CEILINGS, ETC., UNLESS OTHERWISE NOTED. ALL CUTTING AND PATCHING SHALL BE SUBJECT TO THE <br />DIRECTION OF THE LANDLORD, ARCHITECT OR ENGINEER. <br />2. THIS CONTRACTOR SHALL NOT ENDANGER THE STABILITY OF THE STRUCTURE BY CUTTING, DIGGING OR OTHERWISE ALTERING THE <br />STRUCTURE AND SHALL NOT AT ANY TIME CUT OR ALTER WORK OF ANY OTHER CONTRACTOR. <br />3. PATCHING OF WALLS, FLOORS AND ROOF SHALL BE OF SAME MATERIAL AND WORKMANSHIP OF THE SURROUNDING MATERIAL WITH <br />FINISHED SURFACE APPEARING THE SAME AS THE SURROUNDING AREAS. ALL PATCHING SHALL BE PERFORMED BY WORKMEN SKILLED <br />IN THAT TRADE. <br />4. DAMAGE CAUSED BY THE CONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR IN A SUITABLE MANNER <br />ACCEPTABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGERS. <br />5. THE GENERAL CONTRACTOR WILL BE REQUIRED UNDER HIS CONTRACT TO LEAVE ALL CHASES AND OPENINGS IN NEW WALLS, FLOORS, <br />CEILINGS, PARTITIONS, ETC„ WHERE SHOWN ON THE DRAWINGS OR OTHERWISE NECESSARY, TO RECEIVE MECHANICAL WORK, BUT THIS <br />CONTRACTOR SHALL FURNISH HIM FULL INFORMATION AS TO LOCATIONS, DIMENSIONS, ETC., OF SUCH CHASES AND OPENINGS, <br />INCLUDING PROVISION AND PROPER SETTING OF SLEEVES AND OTHER EQUIPMENT IN SUCH TIME AS TO CAUSE NO DELAY TO WORK OF <br />GENERAL CONTRACTOR. <br />6. SHOULD ANY CUTTING OF NEW WALLS, FLOORS, CEILINGS, PARTITIONS, ETC., BE REQUIRED FOR PROPER INSTALLATION OF THE WORK <br />OR APPARATUS OF THIS CONTRACTOR OR BE MADE NECESSARY ON ACCOUNT OF HIS FAILURE TO GIVE GENERAL CONTRACTOR PROPER <br />INFORMATION AT THE TIME REQUIRED, SUCH CUTTING SHALL BE DONE AT HIS OWN EXPENSE, RESTORING THE WORK TO ITS ORIGINAL <br />CONDITION. <br />7. ALL CUTTING AND PATCHING DONE BY THIS CONTRACTOR SHALL BE SUBJECT TO THE DIRECTION AND APPROVAL OF THE ARCHITECT. <br />THIS CONTRACTOR SHALL NOT ENDANGER THE STABILITY OF THE STRUCTURE BY CUTTING, DIGGING, OR OTHERWISE, AND SHALL NOT AT <br />ANY TIME CUT OR ALTER WORK OF ANY OTHER CONTRACTOR WITHOUT THE ARCHITECT'S CONSENT. <br />8. THIS CONTRACTOR SHALL PROVIDE ALL CUTTING REQUIRED FOR INSTALLING PIPE THRU PRECAST CONCRETE FLOOR SECTIONS. ALL <br />HOLES REQUIRED SHALL BE CORE DRILLED OF SUFFICIENT SIZE FOR PIPE AND FOR INSULATION. <br />9. ROOF CUT AND PATCH SHALL BE PERFORMED IN A MANNER TO MAINTAIN THE OWNERS ROOFING WARRANTY. THE CONTRACTOR SHALL <br />CONTACT THE OWNER TO ESTABLISH THE HOLDER OF THE GUARANTEE AND SHALL EMPLOY A ROOFING CONTRACTOR CERTIFIED TO <br />WORK ON THE ROOFING AND MAINTAIN THE GUARANTEE. <br />SECTION 23 0014 - SLEEVES <br />1. THIS CONTRACTOR SHALL INSTALL SLEEVES IN CONNECTION WITH ALL PIPES PASSING THROUGH ALL WALLS, PARTITIONS AND FLOORS. <br />SLEEVES SHALL EXTEND THROUGH FULL THICKNESS OF WALLS AND FLOORS AND SHALL BE CUT FLUSH WITH THE FINISHED SURFACES. <br />SLEEVES IN SLABS SHALL BE CUT 2" ABOVE THE FLOOR SURFACE, <br />2. ALL SLEEVES SHALL BE 22 GAUGE GALVANIZED STEEL MINIMUM FINISHED WITH A SMOOTH EDGE AND PROPERLY SUPPORTED. <br />3. CORE DRILLING FLOORS AND WALLS MUST BE COORDINATED WITH THE LANDLORD AND THE TENANT'S PROJECT MANAGER. <br />4. THIS CONTRACTOR SHALL FURNISH AND INSTALL FIRE STOPPING AT ALL PENETRATIONS THRU RATED FLOORS TO MAINTAIN THE FIRE <br />RATING. 3M FIRE BARRIER SYSTEMS, FLAME SAFE FIRE RETARDANT SYSTEMS, DOW CORNING, SPECSEAL OR EQUAL. THE CONTRACTOR <br />MUST PRESENT UL LISTING DATA SHEETS TO THE TENANT'S PROJECT MANAGER AND LANDLORD TO SHOW THAT THE PENETRATIONS <br />MAINTAIN THE FIRE RATING. <br />SECTION 23 0015 - ACCESS PANELS <br />1. UNLESS OTHERWISE NOTED ON THE DRAWINGS, EACH MECHANICAL CONTRACTOR SHALL FUNISH WALL AND CEILING ACCESS PANELS <br />REQUIRED FOR ALL MECHANICAL ITEMS. <br />2. ACCESS PANELS SHALL BE CESCO, OR APPROVED, AS FOLLOWS: <br />A. DRY WALL TYPE SR 24" X 24" MIN. <br />B. TILE CEILINGS TYPE ACRX 24" X 24" PAIN. <br />C. FIRE RATED CONSTRUCTION TYPE AP-FR 1-1/2 HOUR B LABEL <br />D. MASONRY TYPE W 24" X 24" MIN. <br />SECTION 23 0019 - LABELING <br />1. SELF-ADHESIVE PIPE LABELS: PRINTED PLASTIC WITH CONTACT -TYPE, PERMANENT -ADHESIVE BACKING INDICATING: <br />A. FLOW -DIRECTION ARROWS: INTEGRAL WITH PIPING SYSTEM SERVICE LETTERING TO ACCOMMODATE BOTH DIRECTIONS OR AS <br />SEPARATE UNIT ON EACH PIPE LABEL TO INDICATE FLOW DIRECTION. <br />B. LETTERING SIZE: AT LEAST 1-1/2 INCHES HIGH, <br />2. CLEAN PIPING AND EQUIPMENT SURFACES OF SUBSTANCES THAT COULD IMPAIR BOND OF IDENTIFICATION DEVICES, INCLUDING DIRT, OIL, <br />GREASE, RELEASE AGENTS, AND INCOMPATIBLE PRIMERS, PAINTS, AND ENCAPSULATES. <br />3. INSTALL OR PERMANENTLY FASTEN LABELS ON EACH MAJOR ITEM OF MECHANICAL EQUIPMENT. LOCATE EQUIPMENT LABELS WHERE <br />ACCESSIBLE AND VISIBLE <br />4. EQUIPMENT LABELS <br />A. LABELS FOR OUTDOOR EQUIPMENT: <br />a. LETTERING: STENCILED. <br />b. MINIMUM LETTER SIZE: (4 INCH). <br />5. PIPE LABEL COLOR SCHEDULE: <br />A. NATURAL GAS PIPING: BY PLUMBING CONTRACTOR. <br />a. BACKGROUND COLOR: WHITE. <br />b. LETTER COLOR: BLACK. <br />B. HEATING WATER PIPING: BY HEATING/BOILER CONTRACTOR. <br />a. BACKGROUND COLOR: YELLOW. <br />b. LETTER COLOR: BLACK. <br />6. LOCATE PIPE LABELS WHERE PIPING IS LOCATED ABOVE ACCESSIBLE CEILINGS IN FINISHED SPACES; EXPOSED CEILINGS; MACHINE <br />ROOMS; ACCESSIBLE MAINTENANCE SPACES SUCH AS SHAFTS, TUNNELS, AND PLENUMS; AND EXTERIOR EXPOSED LOCATIONS AS <br />FOLLOWS: <br />A. NEAR EACH VALVE AND CONTROL DEVICE. <br />B. NEAR EACH BRANCH CONNECTION, EXCLUDING SHORT TAKEOFFS FOR FIXTURES AND TERMINAL UNITS, WHERE FLOW PATTERN IS <br />NOT OBVIOUS, MARK EACH PIPE AT BRANCH. <br />C. NEAR PENETRATIONS THROUGH WALLS, FLOORS, CEILINGS, AND INACCESSIBLE ENCLOSURES. <br />SECTION 23 00 50 - SUMMARY OF WORK <br />1. THIS CONTRACTOR SHALL FURNISH, INSTALL, TEST AND BALANCE ALL NECESSARY EQUIPMENT FOR A COMPLETE WORKING SYSTEM. SEE <br />PLAN FOR AREAS OF WORKING DUCTWORK LAYOUTS, SCHEDULES AND DETAILS, <br />SECTION 23 0101 - FINISHES <br />A. ALL PIPING, DUCTWORK AND EQUIPMENT IN FINISHED AREAS SHALL BE FURNISHED AND INSTALLED TO PRESENT A NEAT AND CLEAN <br />APPEARANCE. ALL SURFACES EXCEPT PIPE AND DUCT THAT ARE TO RECEIVE PAINT BY GENERAL CONTRACTOR SHALL HAVE A <br />FACTORY APPLIED PRIME COAT. ALL ITEMS THAT ARE TO HAVE FINISHED PAINT BY MECHANICAL CONTRACTOR SHALL HAVE COLOR <br />SELECTED BY ARCHITECT/ENGINEER. <br />SECTION 23 09 00 - INSTRUMENTATION AND CONTROL FOR HVAC <br />1. SUMMARY <br />A. SECTION INCLUDES: <br />1, CONTROL PANEL ENCLOSURES, <br />2. DIRECT DIGITAL CONTROL SYSTEM COMPONENTS. <br />3. CO AND NO2 DETECTORS. <br />2. PREINSTALLATION MEETINGS <br />A. SECTION 013000 -ADMINISTRATIVE REQUIREMENTS: REQUIREMENTS FOR PREINSTALLATION MEETING. <br />B. CONVENE MINIMUM ONE WEEK PRIOR TO COMMENCING WORK OF THIS SECTION. <br />3. SUBMITTALS <br />A. PRODUCT DATA. <br />1. SUBMIT DESCRIPTION AND ENGINEERING DATA FOR EACH CONTROL SYSTEM COMPONENT, INCLUDING SIZING AS APPLICABLE. <br />2. WHEN MULTIPLE COMPONENTS ARE PROVIDED ON A SUBMITTAL THE SUBMITTAL SHALL CALL OUT THE SPECIFIC COMPONENT, <br />B. SHOP DRAWINGS: <br />1. INDICATE OPERATING DATA, SYSTEM DRAWINGS, WIRING DIAGRAMS, AND WRITTEN, DETAILED OPERATIONAL DESCRIPTION OF <br />SEQUENCES. <br />2. COORDINATE SUBMITTALS WITH INFORMATION REQUESTED IN SECTION 230993 -SEQUENCE OF OPERATIONS FOR HVAC <br />CONTROLS. <br />C. MANUFACTURER'S CERTIFICATE: CERTIFY THAT PRODUCTS MEET OR EXCEED SPECIFIED REQUIREMENTS. <br />D. MANUFACTURER'S INSTRUCTIONS: SUBMIT INSTALLATION REQUIREMENTS FOR EACH CONTROL COMPONENT. <br />E. FIELD QUALITY -CONTROL SUBMITTALS: INDICATE RESULTS OF CONTRACTOR -FURNISHED TESTS AND INSPECTIONS. <br />F. QUALIFICATIONS STAT <br />1. SUBMIT QUALIFICATIONS FOR MANUFACTURER AND INSTALLER. <br />2. SUBMIT MANUFACTURER'S APPROVAL OF INSTALLER, <br />4. CLOSEOUT SUBMITTALS <br />A. PROJECT RECORD DOCUMENTS: RECORD ACTUAL LOCATIONS OF CONTROL COMPONENTS, INCLUDING PANELS, THERMOSTATS, AND <br />SENSORS. <br />B, OPERATION AND MAINTENANCE DATA: SUBMIT INSPECTION PERIOD, CLEANING METHODS, RECOMMENDED CLEANING MATERIALS, AND <br />CALIBRATION TOLERANCES. <br />5. QUALIFICATIONS <br />1. MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE YEARS' <br />DOCUMENTED EXPERIENCE, AND WITH SERVICE FACILITIES WITHIN 100 MILES OF PROJECT. <br />2. INSTALLER: COMPANY SPECIALIZING IN PERFORMING WORK OF THIS SECTION WITH MINIMUM THREE YEARS' DOCUMENTED <br />EXPERIENCE AND APPROVED BY MANUFACTURER, <br />6. WARRANTY <br />A. FURNISH FIVE-YEAR MANUFACTURER'S WARRANTY FOR EACH CONTROL -SYSTEM COMPONENT AND HVAC iNSTRUMENTATIO. <br />7. CONTROL COMPONENT MANUFACTURERS <br />A. MANUFACTURERS: <br />1. HONEYWELL INTERNATIONAL. <br />2. JOHNSON CONTROLS. <br />3. PRICE (STAND ALONE VAV SYSTEMS ONLY) <br />4. SIEMENS. <br />5. TRADE. <br />8. CONTROL PANEL ENCLOSURES <br />A. FURNISH ENCLOSURE FOR EACH SYSTEM UNDER AUTOMATIC CONTROL. <br />B. EQUIPMENT MOUNTING: <br />1. WITHIN CABINET: RELAYS AND CONTROLS. <br />2. FLUSH ON CABINET PANEL FACE: TEMPERATURE INDICATORS, PRESSURE GAGES, PILOT LIGHTS, PUSH BUTTONS, AND SWITCHES, <br />C. CONSTRUCTION: <br />1. COMPLY WITH NEMA 250, TYPE 1. <br />2. MATERIAL: STAINLESS STEEL, STEEL, FRP OR PLASTIC. <br />D. COVERS: <br />1. CONTINUOUS HINGE. <br />2. CLOSURE: FLUSH LATCH OPERABLE BY KEY. <br />E. FINISH: MANUFACTURER'S STANDARD ENAMEL FINISH. <br />12. ALARM SYSTEM <br />A. MANUFACTURERS: <br />1. HONEYWELL INTERNATIONAL. <br />2. JOHNSON CONTROLS <br />3. SIEMENS INDUSTRY INC. <br />4. TRANS. <br />B. ENCLOSURE: COMPLY WITH NEMA 250, TYPE 1. <br />C. COMPONENTS: <br />1. ALARM PANEL: <br />INDIVIDUAL INDICATION, HORN. <br />® SILENCE -ACKNOWLEDGE SWITCH. <br />® TEST SWITCH. <br />2. REMOTE PANELS: <br />m DUPLICATE FUNCTIONS OF PRIMARY PANEL. <br />® ALARM SILENCE -ACKNOWLEDGE SWITCH, TO ACKNOWLEDGE ALARM FROM EACH PANEL. <br />3, MAIN ALARM PANEL <br />a DRY CONTACTS FOR USE WITH REMOTE ALARM MONITORING SYSTEM TO INDICATE [EACH] ALARM CONDITION. <br />9. DIRECT DIGITAL CONTROL SYSTEM COMPONENTS <br />10. INSTALLATION <br />A. SENSORS AND OTHER EXPOSED CONTROL SENSORS: <br />1. INSTALL AFTER LOCATIONS HAVE BEEN COORDINATED WITH OTHER WORK. <br />2. INSTALL 60 INCHES ABOVE FLOOR. <br />3. ALIGN WITH LIGHT SWITCHES. <br />B. CONTROL PANELS: <br />1. INSTALL CONTROL PANELS ADJACENT TO ASSOCIATED EQUIPMENT ON VIBRATION -FREE WALLS OR FREESTANDING SUPPORTS. <br />2. USE ONE CABINET FOR MORE THAN ONE SYSTEM IN THE SAME EQUIPMENT ROOM. <br />3. INSTALL ENGRAVED PLASTIC NAMEPLATES FOR INSTRUMENTS AND CONTROLS INSIDE CABINET AND ENGRAVED PLASTIC <br />NAMEPLATES ON CABINET FACE, AS SPECIFIED IN SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT. <br />4. LABEL WITH APPROPRIATE EQUIPMENT OR SYSTEM !DESIGNATION AS SPECIFIED IN SECTION 230553 IDENTIFICATION FOR HVAC <br />PIPING AND EQUIPMENT. <br />5, INSTALL HAND -OFF -AUTO SWITCHES TO OVERRIDE AUTOMATIC INTERLOCK CONTROLS WHEN SWITCH IS IN HAND POSITION. <br />11. DEMONSTRATION <br />A, DEMONSTRATE COMPLETE OPERATION OF SYSTEMS, INCLUDING SEQUENCE OF OPERATION, EQUIPMENT STARTUP, SHUTDOWN, <br />ROUTINE MAINTENANCE, AND EMERGENCY REPAIR PROCEDURES, TO OWNER'S PERSONNEL. <br />12. MAINTENANCE, <br />A. PROVIDE SERVICE AND MAINTENANCE OF CONTROL SYSTEM FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. <br />B. FURNISH COMPLETE SERVICE OF CONTROLS SYSTEMS, INCLUDING CALLBACKS: <br />VAA, LLC 763.559.9100 <br />2300 Berkshire Lane N, Suite 200 www.vaaeng.com <br />Plymouth, MN 55441 <br />WA Firm Reaistration No. 3035 <br />NOTICE. THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL <br />DRAWINGS, DETAILS, DEVELOPMENTS, GRAPHICS AND MODELS THEREOF, ARE THE <br />EXCLUSIVE PROPERTY OF VAA, LLC, AND CAN'T BE COPIED, DUPLICAI ED, REPRODUCED <br />OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE <br />WORK BE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAA, LLC. <br />COPYRIGHT VAA, LLC 2020- ALL RIGHTS RESERVED. <br />ME- <br />a- <br />z <br />w <br />2 <br />0 <br />zO <br />ZQ <br />w <br />� <br />1> <br />0 <br />www <br />Tt <br />ME912292M <br />m <br />� <br />WW <br />� <br />W <br />N <br />00 <br />0 <br />1._ <br />0-) <br />z <br />< <br />0wo <br />F- <br />NWv�'i <br />WW <br />0� <br /><C <br />W <br />(Dui <br />I REVISION <br />A <br />DATE <br />ISSUED FOR PERMIT <br />0 <br />05/05/21 <br />05/0 /2021 <br />a s , m <br />JOB ' NUMBER <br />205013 <br />DRAWN BY CHECKED BY <br />ASH VJ® <br />SHEET TITLE <br />MECHANICAL SPECIFICATIONS <br />SECTION 23 0016 - ESCUTCHEON PLATES <br />1. WHERE EXPOSED PIPES OR DUCTS PASS THRU FLOORS, WALLS OR CEILINGS IN FINISHED ROOMS, THEY SHALL BE FITTED WITH AN <br />APPROVED TYPE METAL ESCUTCHEON PLATE (PIPE) OR METAL FLANGE (DUCT). ESCUTCHEON PLATES SHALL BE PROPERLY SIZED TO FIT <br />SNUG AGAINST THE PIPE OR INSULATION ON THE INSIDE OF THE ESCUTCHEON AND SHALL BE LARGE ENOUGH TO COMPLETELY COVER <br />THE WALL OR FLOOR PENETRATION OPENING. WHEREVER WET CONDITIONS ARE EXPECTED ON EITHER SIDE OF THE WALL OR FLOOR, <br />THE PENETRATION SHALL BE SEALED WITH A RESILIENT SILICONE CAULK BEFORE THE ESCUTCHEON IS INSTALLED. PLATES ON <br />CHROMIUM PLATED PIPE MUST BE FINISHED CAST OR STAMPED BRASS, CHROMIUM PLATED, FLANGES FOR STAINLESS STEEL OR <br />ALUMINUM DUCT WORK SHALL BE OF A SIMILAR MATERIAL. <br />SHEET NUMBER <br />