BOOFING & WATERPROOFING NOTES
<br />GENERAL NOTES (CONTINUATIOWGENERAL
<br />TES I ATI
<br />CESSIBILITY EXCEPTION T
<br />1. CONTRACTOR SHALL CONTACT THE BUILDING OWNER TO DETERMINE IF ROOF IS UNDER
<br />11.
<br />THE GENERAL CONTRACTOR MUST PERFORM WORK DURING PROPERTY OWNER'S
<br />39.
<br />A PRE -CONSTRUCTION CONFERENCE OF REPRESENTATIVES FROM AFFECTED AGENCIES
<br />1. SECTION 1103.2.7: LIMITED ACCESS SPACES - SPACES NOT CUSTOMARILY OCCUPIED AND
<br />WARRANTY. CONTRACTOR SHALL GUARANTEE THAT ANY AND ALL NEW ROOFING WORK
<br />PREFERRED HOURS TO AVOID DISRUPTION OF NORMAL ACTIVITY.
<br />SHALL BE HELD ON THE JOB AT LEAST ONE (1) WEEK PRIOR TO BEGINNING
<br />ACCESSED ONLY BY LADDERS, CATWALKS, CRAWL SPACES, FEIGHT, ELEVATORS OR VERY
<br />MEETS THE SPECIFICATION OF ANY EXISTING ROOFING WARRANTIES SUCH THAT THE
<br />CONSTRUCTION.
<br />NARROW PASSAGEWAYS SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS
<br />WARRANTY IS NOT MADE INVALID AS A RESULT OF THIS WORK. IF IT IS DETERMINED
<br />12.
<br />ALL EXPOSED METAL SHEET SHALL BE HOT -DIPPED GALVANIZED.
<br />OR TO BE ON AN ACCESSIBLE ROUTE.
<br />THAT THE ARCHITECT'S DETAILING IS INADEQUATE OR IMPROPER OR IF ANY OTHER
<br />40.
<br />DRAWINGS ARE NOT TO BE SCALED UNDER ANY CIRCUMSTANCES, WRITTEN DIMENSIONS
<br />DISCREPANCY IS FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT
<br />13.
<br />PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RAZING OF NOT LESS THAN 2-A OR
<br />TAKE PRECEDENCE OVER SCALE, AND THIS SET OF PLANS IS INTENDED TO BE USED FOR
<br />2. SECTION 1103.2.9: EQUIPMENT SPACES - SPACES FREQUENTED ONLY BY SERVICE
<br />AND THE CLIENT PROJECT MANAGER IN WRITING. ULTIMATELY, THE CONTRACTOR SHALL BE
<br />2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA
<br />DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL PROVIDE
<br />PERSONNEL FOR MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT
<br />RESPONSIBLE FOR COMPLYING WITH THE ORIGINAL ROOF MANUFACTURER'S
<br />CONSTRUCTION.
<br />FIELD MEASUREMENTS AS NECESSARY TO COMPLETE ALL WORKS AND THE GENERAL
<br />SHALL NOT BE REQUIRED TO COMPLY WITH THIS REQUIREMENT OR 10 BE ON AN
<br />SPECIFICATIONS.
<br />CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT,
<br />ACCESSIBLE ROUTE. MACHINERY SPACES INCLUDE, BUT ARE NOT LIMITED TO, ELEVATOR
<br />14.
<br />THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS SHALL
<br />LABOR, AND ANYTHING ELSE DEEMED NECESSARY TO COMPLETE INSTALLATIONS AS
<br />PITS OR ELEVATOR PENTHOUSES; MECHANICAL. ELECTRICAL OR COMMUNICATIONS
<br />2. CONTRACTOR SHALL USE METHODS AND MATERIALS SIMILAR AND COMPATIBLE WITH
<br />PROVIDE THE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES, MATERIALS, AND
<br />DESCRIBED HEREIN. SYNERGY IS NOT RESPONSIBLE FOR ANY ERRORS RESULTING FROM
<br />EQUIPMENT ROOMS; PIPING OR EQUIPMENT CATWALKS; WATER OR SEWAGE TREATMENT
<br />EXISTING MATERIALS & CONDITIONS FOR ROOF PATCHING, NEW PENETRATIONS, ETC.
<br />FINISHES USED THROUGHOUT THE PROJECT TRADE STANDARDS AND/OR PUBLISHED
<br />THIS PRACTICE WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS.
<br />PUMP ROOMS AND STATIONS; ELECTRIC SUBSTATIONS AND TRANSFORMER VAULTS; AND
<br />MANUFACTURERS SPECIFICATIONS MEETING OR EXCEEDING DESIGN REQUIREMENTS SHALL
<br />HIGHWAY AND TUNNEL FACILITIES.
<br />3. THE CONTRACTOR SHALL PROPERLY SEAL ALL NEW ROOF & BUILDING ENVELOPE
<br />BE USED FOR INSTALLATION.
<br />41.
<br />DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR
<br />PENETRATIONS SUCH THAT THE INTEGRITY OF THE ORIGINAL BUILDING ASSEMBLY AND ALL
<br />MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS, AND SUCH
<br />APPLICABLE WARRANTIES ARE MAINTAINED.
<br />15.
<br />PRIOR TO STARTING CONSTRUCTION OF THE CONTRACTOR HAS THE RESPONSIBILITY TO
<br />MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SCOPE OF WORK.
<br />GENERAL RF NOTES
<br />LOCATE ALL EXISTING UTILITIES, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR
<br />4. IF IT DEEMED NECESSARY TO REMOVE EXISTING FINISHED AND/OR MATERIALS, THE
<br />OR SUBCONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY
<br />1. ALL ANTENNAS AND ANTENNA CABLE SHALL BE FURNISHED BY THE CELL CARRIER AND
<br />BY ANTENNA INSTALLATION CONTRACTOR.
<br />CONTRACTOR SHALL BE RESPONSIBLE FOR RECONSTRUCTING FINISHES AND MATERIALS TO
<br />DAMAGE TO THE UTILITIES CAUSED DURING THE EXECUTION OF THE WORK.
<br />IT PREPARATION NOTES
<br />INSTALLED
<br />IN
<br />LINE -NEW CONDITIONS. CONTRACTOR SHALL MAINTAIN THE ORIGINAL COLORS, TEXTURES
<br />'T
<br />16.
<br />A COPY OF THE APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE
<br />1.
<br />THE PREPARATION OF THE SITE FOR CONSTRUCTION SHALL INCLUDE THE REMOVAL OF
<br />2. PRIOR TO INSTALLATION OF ANTENNAS THE CONTRACTOR SHALL VERIFY THAT THE
<br />LI FINISHES UNLESS SPECIFICALLY NOTED T 0 THE CONTRARY APPROVED MOBILE
<br />GOVERNING AGENCY, AND BY LAW SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES.
<br />ALL BROKEN CONCRETE, E, TREE TRUNKS AND ANY OTHER DEBRIS THAT MIGHT DAMAGE THE
<br />AZIMUTH AND DIMENSIONS SHOWN ON THE PLANS MATCH ACTUAL FIELD CONDITIONS.
<br />CONSTRUCTION MANAGER IN ADVANCE.
<br />FOOTINGS OF THE NEW STRUCTURE.
<br />5. AT THE CLIENT CONSTRUCTION MANAGER'S DISCRETION, THE CONTRACTOR SHALL PROVIDE
<br />17.
<br />IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL CONSTRUCTION SETS REFLECT
<br />2.
<br />BACKFILL ALL TRENCHES WITH CLEAN, STERILE SOIL HAVING A SAND EQUIVALENT OF 30%
<br />3. ANTENNA INSTALLATION CONTRACTOR SHALL PROVIDE ALL CONDUIT, CABLE TRAYS,
<br />GROUND KITS, CLAMPS, GROUNDS, ETC., FOR COMPLETE INSTALLATION OF ANTENNAS AND
<br />ROOF -TOP WALKPADS TO ALL NEW EQUIPMENT INCLUDING ANTENNAS AND BTS UNITS AND
<br />THE SAME INFORMATION AS THE APPROVED PLANS. THE CONTRACTOR SHALL ALSO
<br />MAINTAIN ONE SET OF PLANS AT THE SITE FOR THE PURPOSE OF DOCUMENTING ALL
<br />OR GREATER. BACKFILL IN 8 INCH LAYERS, MOISTURE CONDITIONED AND PROPERLY
<br />CABLES SHOWN AND INTENDED AS REQUIRED FOR A COMPLETE OPERATING SYSTEM IN
<br />ALONG COAX CABLE ROUTING. ON CONVENTIONAL ROOFING, THE WALK PADS SHALL BE
<br />"DUCK
<br />AS-BUILI CHANGES, REVISIONS, ADDENDUMS, OR CHANGE ORDERS. THE CONTRACTOR
<br />COMPACTED, ADEQUATE DRAINAGE SHALL BE PROVIDED SUCH THAT NO PONDING OCCURS.
<br />ACCORDANCE WITH T-MOBILE WIRELESS STANDARDS.
<br />BOARDS" AS MANUFACTURED BY APC OR EQUAL. ON SPECIAL ROOFING SYSTEMS
<br />SHALL FORWARD THE AS-BUILI DRAWINGS TO THE ARCHITECT/ENGINEER AND THE
<br />SUCH AS SINGLE MEMBRANE ROOFS WILL REQUIRE A SPECIFIC PRODUCT AS NOTED ON
<br />3.
<br />ALL FOUNDATION FOOTINGS SHALL EXTEND. INTO AND BEAR AGAINST NATURAL
<br />4. ANTENNA CONDUIT SHALL INCLUDE FACTORY -MADE LARGE RADIUS SWEEPS. AT ALL
<br />PLANS OR AS REQUIRED BY NOTES 1 & 2 ABOVE.
<br />LANDLORD/LESSOR AT THE CONCLUSION OF THE PROJECT.
<br />UNDISTURBED SOIL OR APPROVED COMPACTED FILL. FOOTINGS SHALL EXTEND INTO SOIL
<br />CHANGES IN DIRECTION. SWEEP RADIUS SHALL BE AS REQUIRED TO MEET COAX
<br />18.
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE
<br />DEPTH AS INDICATED IN PLANS.
<br />MANUFACTURER'S MINIMUM BENDING RADIUS.
<br />PENETRATION AT FIE RATED ASSEMBLIES NOTES
<br />FROM THE START TO THE COMPLETION OF THE PROJECT. THE CONTRACTOR SHALL
<br />4.
<br />SHOULD ANY LOOSE FILL, EXPANSIVE SOIL, GROUND WATER OR ANY OTHER UNEXPECTED
<br />5. ALL UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC WITH STEEL BENDS. ALL
<br />MAINTAIN ACCESS TO THE SITE AT ALL TIMES FOR THE LANDLORD/LESSOR PERSONNEL.
<br />CONDITIONS BE ENCOUNTERED DURING THE EXCAVATION FOR THE NEW FOUNDATION, THE
<br />EXPOSED CONDUIT ABOVE GRADE LEVEL SHALL BE IMC OR RIGID GALVANIZED. ALL
<br />1. AT THE CLIENT PROJECT MANAGER'S DIRECTION, THE CONTRACTOR SHALL PROVIDE " HILTI"
<br />ARCHITECT/ENGINEER SHALL BE NOTIFIED AND ALL FOUNDATION WORK SHALL CEASE
<br />EXPOSED CONDUIT PROTECTED IN A BUILDING OR ON A ROOF SHALL BE EMT OR UV
<br />HIGH PERFORMANCE FIRESTOP SYSTEM #FS601 AT ALL FIRE RATED PENETRATIONS
<br />19.
<br />THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY POWER, WATER AND
<br />IMMEDIAI ELY.
<br />STABILIZED, PAINTED, SCHEDULE 80 PVC.
<br />TOILET FACILITIES.
<br />INSTALLED PER MANUFACTURER'S LATEST INSTALLATION SPECIFICATIONS.
<br />5.
<br />WITHIN AN AREA A MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS, EXCAVATE A
<br />6. IN HIGH TRAFFIC AREAS OR WHERE SUSCEPTIBLE TO DAMAGE CONTRACTOR SHALL
<br />2. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE CONSTRUCTED SO AS TO
<br />20.
<br />ALL CONSTRUCTION PHASES OF THE PROJECT SHALL CONFORM TO THE CURRENT
<br />MINIMUM OF 4 INCHES OF EXISTING SOIL. REMOVE ALL ORGANICS, PAVEMENT, ROOTS,
<br />PROVIDE FORMED 14 GA GALVANIZED SHEET METAL COVER OVER COAXIAL CABLE ROUTES.
<br />MAINTAIN AN EQUAL OR GREATER FIRE RATING.
<br />GOVERNING CODES.
<br />DEBRIS AND OTHERWISE UNSUITABLE MATERIAL.
<br />WHERE CABLE IS RUN ON THE WALL, ATTACH UNISTRUT TO WALL AND COVER WITH 14
<br />GA GALVANIZED FORMED SHEET METAL COVER OR MATERIAL AS DIRECTED BY T -MOBILE
<br />21.
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY
<br />6.
<br />THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED BY PROBING OR
<br />WIRELESS PROJECT MANAGER.
<br />PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE OR
<br />TESTING TO CHECK FOR POCKETS OF SOFT OR UNSUITABLE MATERIAL. EXCAVATE
<br />GENERAL CES
<br />PROVIDE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS.
<br />UNSUITABLE SOIL AS DIRECTED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY.
<br />7. VERIFY ROUTE AND LENGTH OF CABLE PRIOR TO CUTTING. ADJUST INDICATED ROUTE AS
<br />1. THE LATEST EDITION OF THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201
<br />22.
<br />THE CONTRACTOR SHALL SUPERVISE AND COORDINATE ALL WORK, USING PROFESSIONAL
<br />REQUIRED TO CLEAR EXISTING OBSTRUCTIONS AND MAINTAIN REQUIRED CLEARANCE FROM
<br />"GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" ARE INCLUDED IN THESE
<br />KNOWLEDGE AND SKILLS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL
<br />7.
<br />PROOF ROLL THE SURFACE OF THE EXPOSED SUBGRADE WITH A LOADED TANDEM AXLE
<br />EXISTING EQUIPMENT AND FACILITIES.
<br />SPECIFICATIONS AS IF COMPLETELY REPRODUCED HEREIN.
<br />CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, SEQUENCING AND
<br />DUMP TRUCK. REMOVE ALL SOILS WHICH PUMP OR DO NOT COMPACT PROPERLY AS
<br />8. MAXIMUM LENGTH OF 7/8 INCH COAXIAL CABLE SHALL BE 140 FEET. MAXIMUM LENGTH
<br />COORDINATING ALL PORTIONS OF THE WORK.
<br />DIRECTED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY.
<br />2. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATION.
<br />OF 1-5/8 INCH COAXIAL CABLE SHALL BE 240 FEET.
<br />23.
<br />THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR ALL PERMITS,
<br />8.
<br />FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE IN 8 INCHES
<br />3. THIS FACILITY IS AN UNOCCUPIED TELECOMMUNICATIONS SITE AND IS EXEMPT FROM
<br />LICENSES AND/OR INSPECTIONS TO COMPLETE THE PROJECT. BUILDING PERMIT
<br />LOOSE LIFTS AND THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698.
<br />9. VERIFY MODEL NUMBERS OF ANTENNAS WITH T-MOBILE WIRELESS SERVICES.
<br />DISABLED ACCESS REQUIREMENTS.
<br />APPLICATIONS SHALL BE FILED BY THE OWNER OR THE REPRESENTATIVE. CONTRACTOR
<br />COMPACT TO A MINIMUM OF 90% RELATIVE COMPACTION
<br />SHALL OBTAIN THE PERMIT AND MAKE FINAL PAYMENT OF THE SAID DOCUMENT.
<br />THE CONTRACTOR SHALL PROVIDE TESTING OF ANTENNAS AND SHALL PROVIDE
<br />4. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS PARTICIPATING SHALL VISIT THE
<br />9.
<br />9.
<br />ANY STRUCTURAL DRAWINGS HERE IN REPRESENT THE FINISHED STRUCTURE. THE
<br />DOCUMENTATION TO THE CELL CARIER PROJECT MANAGER.
<br />JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS AFFECTING THE
<br />24.
<br />ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE UNLESS OTHERWISE NOTED.
<br />CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT
<br />PROPOSED PROJECT INCLUDING DEMOLITION, ELECTRICAL, MECHANICAL AND STRUCTURAL
<br />AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND
<br />11. INSTALL EMBOSSED ALUMINUM IDENTIFICATION TAGS AT THE END OF THE MAIN COAXIAL
<br />INSTALLATIONS, AS WELL AS WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS AND
<br />25.
<br />THE CONTRACTOR SHALL PROVIDE THE FIRE MARSHALL APPROVED MATERIALS TO
<br />CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY
<br />CABLE RUNS, ALONG WITH THE END OF THE JUMPER CABLE LOCATED WITHIN THE
<br />SHALL CONFIRM THAT THE PROJECT CAN BE ACCOMPLISHED AS SHOWN PRIOR TO
<br />FILL/SEAL PENETRATIONS THROUGH THE FIRE RATE ASSEMBLIES.
<br />AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE
<br />PLINTH SECTION OF THE BTS UNIT.
<br />PROCEEDING WITH THE CONSTRUCTION. SHOULD ANY ERRORS, OMISSION, OR
<br />SOLE RESPONSIBILITY OF THE CONTRACTOR.
<br />DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY
<br />26.
<br />NEW CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL BE MATCHED IN FORM,
<br />SYNERGY AND THE PROJECT ARCHITECT / ENGINEER IN WRITING. IN THE EVENT OF
<br />TEXTURE, MATERIAL AND PAINT COLOR EXCEPT AS NOTED IN THE PLANS.
<br />10.
<br />THE ARCHITECT/ENGINEER IS NOT RESPONSIBLE FOR COMPLICATIONS, DAMAGES, INJURY,
<br />DISCREPANCIES FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY SYNERGY
<br />OR DEATH ARISING OUT OF ANY KIND OF NEGLIGENCE PRIOR TO COMPLETION OF THE
<br />AND THE PROJECT ARCHITECT / ENGINEER IN WRITING. IN THE EVENT OF DISCREPANCIES
<br />27.
<br />WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AVAILABLE
<br />FINISHED STRUCTURE.
<br />THE CONTRACTOR SHALL INCLUDE THE MORE COSTLY OR EXTENSIVE WORK IN THE BID,
<br />AS REQUIRED BY THE LOCAL GOVERNING AGENCY RESPONSIBLE FOR RECORDING THE
<br />UNLESS SPECIFICALLY DIRECTED OTHERWISE. THE CONTRACTOR SHALL BE RESPONSIBLE
<br />RESULTS.
<br />11.
<br />PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL PROTECT ALL AREAS FROM
<br />FOR CORRECTING ANY ERROR, OMISSION, OR INCONSISTENCY AFTER THE START OF THE
<br />DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW OR EXISTING
<br />CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE PROJECT
<br />28.
<br />ALL GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE
<br />SURFACES, STRUCTURES OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR REPLACED
<br />ARCHITECT / ENGINEER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION.
<br />USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHERWISE.
<br />TO THE SATISFACTION OF THE PROPERTY OWNER. THE CONTRACTOR SHALL BEAR THE
<br />THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY THE PROJECT
<br />EXPENSE OF REPAIRING OR REPLACING ANY DAMAGED AREAS.
<br />ARCHITECT j ENGINEER.
<br />29.
<br />ALL DEBRIS AND REFUSE IS TO BE REMOVED FROM THE PROJECT DAILY. PREMISES
<br />SHALL BE LEA IN A CLEAN jSWEPT CONDITION AT ALL TIMES.
<br />12.
<br />WHEN REQUIRED STORAGE OF MATERIALS OCCURS, MATERIAL SHALL BE EVENLY
<br />5. THE CONTRACTOR SHALL INCLUDE IN THE BID ALL MATERIALS, EQUIPMENT,
<br />DISTRIBUTED OVER THE FLOOR OR ROOF SO AS NOT TO EXCEED THE DESIGNED LIVE
<br />APPURTENANCES AND LABOR NECESSARY TO COMPLETE THE WORK AS INDICATED OR
<br />30.
<br />ALL SYMBOLS AND ABBREVIATIONS ARE CONSIDERED CONSTRUCTION INDUSTRY
<br />LOADS FOR THE STRUCTURE. TEMPORARY SHORING OR BRACING SHALL BE PROVIDED
<br />IMPLIED BY THESE DRAWINGS.
<br />STANDARDS. IF A CONTRACTOR HAS A QUESTING REGARDING THEIR EXACT MEANING THE
<br />WHERE THE STRUCTURE OR SOIL HAS NOT ATTAINED THE DESIGN STRENGTH FOR THE
<br />ARCHITECT/ENGINEER SHALL BE NOTIFIED FOR CLARIFICATIONS.
<br />CONDITIONS PRESENT,
<br />6. THE CONTRACTOR SHALL PROVIDE CONTINUOUS SUPERVISION WHILE ANY
<br />13.
<br />PRIOR I0 PROCEEDING WITH ANY WORK WITHIN AN EXISTING FACILITY, THE CONTRACTOR
<br />SUBCONTRACTORS OR WORKERS ARE ON THE SITE AND SHALL SUPERVISE AND DIRECT
<br />31.
<br />THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND
<br />SHALL BE FAMILIAR HIMSELF WITH EXISTING STRUCTURAL AND OTHER CONDITIONS. IT
<br />ALL WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY
<br />SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF THE WORK
<br />SHALL BE THE CONTRACTOR'S RESPONSIBILITY PROVIDE ALL NECESSARY BRACING,
<br />RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND
<br />IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
<br />SHORING AND OTHER SAFEGUARDS TO MAINTAIN ALL L PARTS OF THE EXISTING WORK IN A
<br />SEQUENCES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE
<br />SAFE CONDITION DURING THE PROCESS OF DEMOLITION AND CONSTRUCTION AND TO
<br />CONTRACT.
<br />32.
<br />CONTRACTORS SHALL BID WALK THE PROJECT TO ASCERTAIN CONDITIONS WHICH MAY
<br />PROTECT FROM DAMAGE THOSE PORTIONS OF THE EXISTING WORK WHICH ARE TO
<br />ADVERSELY AFFECT THE WORK OR COST THEREOF.
<br />7. WORKMANSHIP THROUGHOUT SHALL BE OF THE BEST QUALITY OF THE TRADE INVOLVED,
<br />REMAIN.
<br />AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM REFERENCE STANDARDS FOR
<br />33.
<br />THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, THE DIMENSIONS,
<br />QUALITY AND PROFESSIONAL CONSTRUCTION PRACTICE:
<br />ELEVATIONS, ETC. NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE
<br />SHOP IE
<br />NEW WORK TO THE EXISTING WORK. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS
<br />-DRAWING
<br />NCRA NATIONAL ROOFING CONTRACTORS ASSOCIATION
<br />NECESSARY FOR THE FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. ANY
<br />1.
<br />REVIEW BY THE ARCHITECT/ENGINEER IS FOR GENERAL COMPLIANCE WITH THE DESIGN
<br />0' HARE INTERNATIONAL CENTER
<br />DISCREPANCY SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE
<br />CONCEPT AND THE CONTRACT DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE
<br />10255 W. HIGGENS ROAD, SUITE 600
<br />ARCHITECT/ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK AND
<br />CONSTRUED AS RELIEVING THE CONTRACTOR FROM COMPLIANCE WITH THE PROJECT
<br />ROSEMONT, IL 60018
<br />MATERIALS INCLUDING THOSE FURNISHED BY THE SUBCONTRACTOR(S).
<br />PLANS AND SPECIFICATIONS, NOR DEPARTURES THERE FROM. THE CONTRACTOR REMAINS
<br />RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFIRMING AND CORRELATING ALL
<br />SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS
<br />34.
<br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING
<br />QUANTITIES AND DIMENSIONS, FOR SELECTION FABRICATION PROCESSES.
<br />NATIONAL ASSOCIATION
<br />UTILITIES WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE
<br />4201 LAFAYETTE CENTER DRIVE
<br />CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION
<br />LANDLORDAESSOR
<br />NOTES
<br />CHANT ILLY, VA 20151
<br />WITH THE EXECUTION OF THIS WORK. GENERAL CONTRACTOR SHALL NOTIFY THE ENGINEER
<br />AND ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES FOUND WITHIN THE CONTRACT
<br />1.
<br />A PRECONSTRUCTION CONFERENCE OF REPRESENTATIVES FROM APPLICABLE AGENCIES
<br />IILP INTERNATIONAL INSTITUTE FOR LATH AND PLASTER
<br />DOCUMENTS, PRIOR TO STARTING WORK.
<br />SHALL BE HELD ON SITE AT LEAST ONCE PRIOR TO BEGINNING CONSTRUCTION AT WHICH
<br />P.O. BOX 1663
<br />TIME A CONSTRUCTION SCHEDULE AND 24-HOUR CONTACT INFORMATION SHALL BE
<br />LAFAYETTE, CA 94549
<br />35.
<br />ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE
<br />PROVIDED TO LANDLORD/LESSOR.
<br />ENCOUNTERED IN WORK, SHALL BE PROTECTED AT ALL TIMES, AND WHERE REQUIRED
<br />8. INSTALL ALL EQUIPMENT AND MATERIALS PER THE LATEST EDITION OF THE
<br />FOR THE PROPER EXECUTION OF WORK, SHALL BE RELOCATED AS DIRECTED BY
<br />2.
<br />CONTRACTOR SHALL MAINTAIN ACCESS TO THE SITE AT ALL TIMES FOR LANDLORD/LESSOR
<br />CITY I`P EVER TT
<br />MANUFACTURER'S INSTALLATION SPECIFICATIONS UNLESS SPECIFICALLY OTHERWISE
<br />ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING
<br />PERSONNEL. OPEN TRENCHES SHALL BE PROPERLY PLATED AT THE END OF EACH
<br />REVIEWED FOR PERMIT
<br />INDICATED, OR WHERE LOCAL CODES OR REGULATIONS PRECEDENCE.
<br />OR PIER DRILLING AROUND OR NEAR UTILITIES.
<br />WORKING DAY TO ALLOW FOR 24-HOUR LANDLORD/LESSOR ACCESS TO THE SITE.
<br />9. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL GIVE ALL NOTICES AND SHALL
<br />36.
<br />ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH
<br />COMPLY WITH ALL APPLICABLE LOCAL CODES, REGULATIONS, LAWS AND ORDINANCES AS
<br />INTERFERE WITH THE EXECUTION OF WORK, SHALL BE REMOVED AND SHALL BE CAPPED,
<br />3.
<br />THE CONTRACTOR AND CELL CARRIER SHALL BE RESPONSIBLE FOR ANY DAMAGE DUE TO
<br />WELL AS STATE DEPARTMENT OF INDUSTRIAL REGULATIONS AND DIVISION OF INDUSTRIAL
<br />PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE
<br />CONSTRUCTION ACTIVITIES TO THE EXISTING SITE AND SHALL RETURN DAMAGED FACILITIES
<br />SAFETY (OSHA) REQUIREMENTS.
<br />EXECUTION OF WORK, SUBJECT TO THE APPROVAL OF THE ENGINEER,
<br />TO EXISTING CONDITION OR BETTER AT NO COST TO THE LANDLORD/LESSOR.NOTE:
<br />10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY
<br />37
<br />CHANCES BE THESE PU WITHOUT THEWRITTEN
<br />4
<br />SHALL SERVICE ALERT (�
<br />NWORKO A
<br />INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGE GOOD AND/OR FAULTY
<br />CHANGESKNOWLEDGE
<br />UNAUTHORIZEDNS
<br />OFARE
<br />CONSENTTHEO ARCHITDCTTONGINEER.RENDER THESE
<br />®0IG
<br />PR OTR�OUBEGINNROG CONSTRUCTION AT 1UND
<br />TWO (2)THE
<br />G DAYS422) 4Ai 33LEASTCONTRACTOR
<br />CONSTRUCTIONITT ONS BEFORE
<br />WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS COMPLETE A D ACCEPTED
<br />DRAWINGS VOID.
<br />UNDER THIS CONTRACT; UNLESS NOTED OTHERWISE IN THE CONTRACT BETWEEN THE
<br />5,
<br />ALL NEW AND EXISTING FACILITIES OWNED BY THE REPRESENTED CELLULAR CARRIER
<br />SUBMITTAL
<br />OWNER AND CONTRACTOR. EXCEPTION: THE ROOFING SUBCONTRACTOR SHALL FURNISH A
<br />38.
<br />ANY REFERENCES TO THE WORDS APPROVED, OR APPROVAL IN THESE DOCUMENTS SHALL
<br />SHALL BE PROPERLY TAGGED IDENTIFYING THE OWNER'S NAME AND 24-HOUR PHONE
<br />MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE GENERAL
<br />BE HERE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE
<br />NUMBER.
<br />CONSTRUCTIONFABRICATION.
<br />CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATER TIGHT CONDITION FOR A PERIOD OF
<br />THE CONTRACTOR AND/OR HIS SUBCONTRACTORS OF ANY LIABILITY IN FURNISHING THE
<br />i
<br />TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE
<br />REQUIRED MATERIALS OR LABOR SPECIFIED.
<br />6.
<br />THE CONTRACTOR IS RESPONSIBLE TO ENSURE THE SITE IS SECURE DURING BOTH
<br />PROJECT, UNLESS OTHERWISE WRITTEN IN THE CONTRACT BETWEEN THE OWNER AND THE
<br />WORKING AND NON -WORKING HOURS,
<br />I
<br />I
<br />CONTRACTOR.
<br />s
<br />I
<br />®PROOFING PENETRA-1-10N AND
<br />4
<br />GENERAL NOTES
<br />I- NUJL Ul IINrUKIVIf-\I IUIN:
<br />NAME-
<br />MASONICT
<br />220 OLYMPIC BLDV. EVERETT, WA 98203
<br />-CURRENT ISSUE DATE:
<br />04/05/22
<br />-ISSUED FOR:
<br />CONSTRUCIrION
<br />=REV.: DATE: D�cnoir)Tinr.i. r�v.-
<br />A
<br />10/06/2021
<br />907,
<br />0
<br />03/21 /2022
<br />1 00'.
<br />A
<br />04/05/22
<br />100;
<br />PE
<br />-PLANS PREPARED BY:
<br />2500 Red Hill Ave., #220, Santa Ana, CA 92705
<br />Office: (949) 202-4913 Fax: (818) 840-0708
<br />:CONSULTANT:
<br />2500 Red Hill Ave., #220, Santa Ana, CA 92705
<br />Office: (949) 202-4913 Fax: (818) 840-0708
<br />:DRAWN BY: CHK.: -APV.:
<br />PLR AM AM
<br />=LICENSURE:
<br />SHEET TITLE:
<br />I-cuF-_�_not inAF�F_Q• QI/ICI(li\I
<br />
|