GENERAL TES <br />STRUCTURAL_NOTES (CONTINUATIO <br />FIBER_ ---REINFORCED P STIC E P) <br />1. <br />ALL CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND <br />6. MATERIAL CONFORMANCE: <br />1. <br />ALL CONNECTIONS SHALL BE 5/8" DIAMETER FIBER BOLTS, U.N.O. (PULTEX 1625 OR <br />CURRENT GOVERNING CODES AND SPECIFICATIONS. <br />A. WIDE FLANGE STEEL SECTIONS PER ASTM A572 OR A992 WITH Fy = 50 KSI <br />EQUIVALENT) AND ALL HOLES UNLESS NOTED OTHERWISE SHALL BE PUNCHED OR <br />B. PIPES SECTIONS PER ASTM A501 WITH Fy = 36 KSI <br />DRILLED 1 /16" LARGER IN DIAMETER THAN THE BOLTS THEY RECEIVE. <br />2. <br />THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB <br />C. TUBE STEEL SECTIONS PER ASTM A500 WITH Fy = 46 KSI <br />SITE AND SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND <br />D. COLD FORMED STEEL PER ASTM A653 WITH Fy = 50 KSI <br />2. <br />ALL CONTACT SURFACES OF FRP STRUCTURAL SHAPES AND/OR HYBRID POLYMER <br />CONDITIONS OF ALL WORK AND MATERIALS INCLUDING THOSE FURNISHED BY <br />E. WELDING ELECTRODES PER AWS CODE, E70XX UNLESS NOTED OTHERWISE ON PLANS <br />COMPOSITE ARCHITECTURAL PANELS SHALL BE BONDED PER MANUFACTURER'S <br />SUBCONTRACTORS. ANY DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE <br />F. ALL OTHER MISCELLANEOUS STEEL SHALL BE ASTM A36 WITH Fy = 36 KSI UNLESS <br />STRUCTURAL ENGINEER IMMEDIATELY AND SHALL BE RESOLVED BEFORE PROCEEDING WITH <br />NOTED OTHERWISE ON THE PLANS <br />RECOMMENDATIONS. USE 1/4" FRP SCREEN SKIN AND EPDXY GLUE SKIN TO FRAMING <br />THE WORK. <br />MEMBERS WITH 3/8" DIAMETER FIBER BOLTS AT 24" O.C. EIFS SHALL MATCH BUILDING <br />AND BE ATTACHED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />3. <br />STRUCTURAL DRAWINGS SHALL WORK IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL <br />ADHESIVE / MECHANICAL ANCHORS <br />AND ELECTRICAL DRAWINGS. <br />3. <br />ALL LIQUID NAILS MULTI -PURPOSE CONSTRUCTION ADHESIVE SHALL BE PER MACCO OR <br />1. ALL POST -INSTALLED ANCHORS SHALL BE PER SIMPSON OR HILTI MANUFACTURING AS <br />APPROVED EQUIVALENT. BONDING SURFACE SHALL BE CAREFULLY PREPARED TO ENSURE <br />4. <br />DESIGN, MATERIALS, EQUIPMENT, AND PRODUCTS 01-HER THAN THOSE DESCRIBED OR <br />INDICATED ON THE PLANS. <br />A GOOD ADHESIVE BOND BY WIPING THE SURFACE WITH A STERILIZING SOLVENT, <br />INDICATED ON THE DRAWINGS MAY BE CONSIDERED FOR USE PROVIDED PRIOR APPROVAL <br />REMOVING SURFACE GLOSS BY LIGHT SANDING, APPLY ADHESIVE, AND FASTEN OR CLAMP <br />IS OBTAINED FROM THE STRUCTURAL ENGINEER. <br />2. MECHANICAL ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING <br />BONDING SURFACES UNTIL CURED. <br />APPROVAL CODES: <br />5. <br />ALL CONDITIONS SHOWN OR NOTED AS EXISTING ARE BASED ON THE BEST INFORMATION <br />FOR HILTI KWIK BOLT TZ2 ANCHORS, INSTALLATION SHALL COMPLY WITH ICC-ES <br />4. <br />ALL EXPOSED JOINTS AT ARCHITECTURAL PANELS AHD SHAPES (EDGES, CORNERS, ETC.) <br />AVAILABLE AT THE TIME OF PREPARATION OF THESE DRAWINGS. NO WARRANTY IS <br />ESR-4561 FOR ANCHORAGE TO MASONRY AND ICC-ES ESR-4266 FOR ANCHORAGE <br />SHALL BE CAULKED WITH AN APPROVED FLEXIBLE POLYURETHANE SEALANT/CAULK. <br />IMPLIED TO THEIR ACCURACY. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS. <br />TO CONCRETE. <br />SHOULD CONDITIONS BECOME APPARENT THAT DIFFER FROM THE CONDITIONS SHOWN, <br />5. <br />ALL OPEN ENDS OR GAPS OF SCREEN FRAMING WHERE WATER SUSCEPTIBLE TO WATER <br />THEY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE PROFESSIONAL <br />ADHESIVE ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING <br />INFILTRATION SHALL BE WEATHER CAPPED OR SEALED BY THE GENERAL CONTRACTOR. <br />ENGINEER. PROFESSIONAL ENGINEER WILL THEN PREPARE ADDITIONAL DRAWINGS AS MAY <br />APPROVAL CODES: <br />BE NEEDED TO ACCOMMODATE THE CONDITIONS AS BROUGHT TO THEIR ATTENTION. <br />FOR SIMPSON SET-XP EPDXY ANCHORS, INSTALLATION SHALL BE IN ACCORDANCE <br />6. <br />ALL FRP MATERIAL SHALL CONFORM TO ASTM D-638, 695, 790, 2344, 732, <br />WITH ICC-ES ESR-2508 FOR ANCHORAGE TO CONCRETE, IAPMO UES ER-265 FOR <br />ADDITIONALLY WITH BOLTS CONFORMING TO ASTM B-565. ALL FRP MATERIAL SHALL <br />6. <br />MECHANICAL EQUIPMENT MUST BE FIRMLY ATTACHED TO -THE STRUCTURE. ISOLATORS, <br />ANCHORAGE TO MASONRY. <br />HAVE THE FOLLOWING MINIMUM PROPERTIES FOR ALLOWABLE STRESS DESIGN (BASED ON <br />FASTENERS, AND OTHER ELEMENTS PROVIDING STABILITY FOR MECHANICAL EQUIPMENT <br />FOR HILTI HIT-HY 200 EPDXY ANCHORS, INSTALLATION SHALL BE IN ACCORDANCE <br />A SAFETY FACTOR OF 7). VALUES ARE REPRESENTED IN KSI. <br />SHALL BE CAPABLE OF TRANSMITTING CODE REQUIRED LOADS, BUT IN NO EVENT LESS <br />WITH ICC ESR-3187 FOR ANCHORAGE TO CONCRETE. <br />THAN A SHEAR LOAD EQUIVALENT TO 0.45 TIMES THE OPERATING WEIGHT OF THE <br />MECHANICAL PROPERTY LENGTHWISE CROSSWISE <br />EQUIPMENT. <br />3. ALLOW A MINIMUM OF 72 HOURS AFTER NEW CONCRETE IS PLACED PRIOR TO LOCATING <br />TENSILE STRESS Ft 4.3 1.0 <br />MECHANICAL OR ADHESIVE ANCHORS. ALL MECHANICAL/ADHESIVE ANCHORS REQUIRE <br />COMPRESSIVE STRESS Fc 4.3 2.1 <br />7. <br />WATERPROOFING: SEE ARCHITECTURAL DRAWINGS. <br />SPECIAL STRUCTURAL INSPECTION PER THE BUILDING CODE. <br />FLEXURAL STRESS Fy 4.3 1.4 <br />MODULUS OF ELASTICITY E 2.8X10_6 -- <br />8. <br />THE FOUNDATION DESIGN IS BASED ON 2018 IBC TABLE 1806.2. ALLOWABLE SOIL <br />SHEAR Fv 0.6 -- <br />BEARING VALUE IS 1500. <br />BOLT SHEAR 1.2 -- <br />9. <br />THE NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL <br />MASONRY <br />STRUCTURAL NOTES AND TYPICAL DETAILS. <br />1. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90, MEDIUM WEIGHT, GRADE N <br />10. <br />TYPICAL DETAILS MAY NOT NECESSARILY BE CUT ON PLANS, BUT APPLY UNLESS NOTED <br />WITH Fm = 1500 PSI. <br />OTHERWISE. <br />SPECIAL STRUCTURAL INSPECTION STRUCTURAL UCT L ONLY <br />2. MORTAR TYPE S, Fm = 1800 PS{ <br />CONCRETE <br />3. PROVIDE EXPANSION JOINTS IN MASONRY WALLS EVERY 24'-0" O.C. <br />1. <br />SPECIAL STRUCTURAL INSPECTION IS TO BE PROVIDED FOR THE ITEMS LISTED BELOW IN <br />1. <br />ALL POURED -IN -PLACE CONCRETE SHALL HAVE AN ULTIMATE COMPRESSIVE STRENGTH OF <br />ADDITION TO THE INSPECTIONS CONDUCTED BY THE BUILDING JURISDICTION. SPECIAL <br />3000 PSI AT 28 DAYS. UNLESS OTHERWISE NOTED, CEMENT TO BE TYPE-8 FROM <br />4. VERTICAL REINFORCING SHALL BE 1 #5 VERTICAL IN CENTER OF GROUTED CELL <br />STRUCTURAL INSPECTION IS REQUIRED FOR THE FOLLOWING: <br />TESTED STOCK PER ASTM C-150. <br />CONTINUOUS FULL HEIGHT OF WALL AT ALL CORNERS, INTERSECTIONS, WALL ENDS, BEAM <br />VERIFICATION AND INSPECTION TYPE REFERENCE STANDARD <br />BEARINGS, JAMBS, EACH SIDE OF CONTROL JOINTS AND AT INTERVALS NOT TO EXCEED <br />INSPECTION CONTINUOUS PERIODIC <br />2. <br />CONCRETE FORM TOLERANCES SHALL BE WITHIN THE STANDARDS SET BY THE AMERICAN <br />48" O.C. UNLESS NOTED OTHERWISE ON THE PLANS. TIE AT 8'-0" O.C. VERTICALLY <br />CONCRETE INSTITUTE. <br />WITH SINGLE WIRE LOOP TIE BY AA WIRE PRODUCTS COMPANY OR EQUTALENT. DOWEL <br />STEEL CONSTRUCTION <br />VERTICAL REINFORCING TO FOUNDATION WITH DOWELS TO MATCH VERTICAL REINFORCING. <br />WELDING <br />3. <br />ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS OR OTHER INSERTS SHALL BE <br />AT FLOOR AND ROOF AWS D1.3 <br />SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING DEPARTMENT INSPECTOR <br />5. HORIZONTAL REINFORCING SHALL CONSIST OF 2 #5 CONTINUOUS AT ELEVATED FRAMING <br />DECK WELDS <br />PRIOR TO THE POURING OF ANY CONCRETE. <br />ASSEMBLIES. 1 #5 CONTINUOUS AT TOP OF PARAPETS AND FREESTANDING WALLS. <br />FOR REINFORCING STEEL AWS D1.4, ACI 318 <br />4. <br />NO PIPES OR DUCTS SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY <br />PLACE THESE BARS CONTINUOUS THROUGH CONTROL JOINTS. INSTALL BENT BARS TO <br />FOR STRUCTURAL STEEL <br />DETAILED. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL <br />MATCH HORIZONTAL REINFORCING AT CORNERS AND INTERSECTIONS TO MAINTAIN BOND <br />DRAWINGS FOR LOCATIONS. <br />BEAM CONTINUITY. STANDARD WEIGHT (NO. 9 GAGE WIRE) DUR-O-WALL OR <br />HIGH STRENGTH BOLTING X AISC 360-16, 2014 RCSC <br />DUR-O-WIRE (OR EQUIVALENT) LADDER TYPE JOINT REINFORCING AT 16" O.C. LAP <br />5. <br />FORM EXPOSED CORNERS OF COLUMNS, BEAMS, WALLS, ETC. WITH 3/4" CHAMFERS <br />LADDER TYPE JOINT REINFORCING 12" MINIMUM. <br />CONCRETE CONSTRUCTION <br />REINFORCING STEEL ACI 318 <br />UNLESS DETAILED OTHERWISE. <br />6. LAP SPLICES FOR VERTICAL AND HORIZONTAL REINFORCING SHALL BE PER TYPICAL <br />POST -INSTALLED ANCHORS X ACI 318 <br />6. <br />PROVIDE LIGHT BROOM FINISH ON ALL EXPOSED CONCRETE UNLESS NOTED OTHERWISE. <br />DETAILS. DO NOT SPLICE WITHIN 8'-0" OF CONTROL JOINTS. <br />USE OF REQUIRED DESIGN MIX ACI 318 <br />REINFORCING <br />STEEL <br />WOOD <br />MASONRY CONSTRUCTION TMS 402 AND 602/ <br />ACI 530 <br />1. <br />REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60 U.N.O. <br />1. IN STUD WALLS, UNLESS NOTED OTHERWISE, INSTALL DOUBLE STUDS AT ALL JAMBS, <br />REINFORCING STEEL <br />CORNERS, INTERSECTIONS AND AT ISOLATED BEARING POINTS OF FRAMING MEMBERS <br />GROUT PLACEMENT <br />ABOVE. EVERY OTHER STUD OF WOOD FRAME BEARING WALL SHALL HAVE A SIMPSON <br />CLEANOUTS PRIOR TO CLOSURE <br />2. <br />BARS SHALL BE CLEAN OF MUD, OIL, OR OTHER COATINGS LIKELY TO IMPAIR BONDING. <br />H3 ANCHOR TOP AND BOTTOM, EXCEPT AT THOSE WALLS WHERE PLYWOOD SHEATHING IS <br />POST -INSTALLED ANCHORS <br />NAILED DIRECTLY TO THE TOP AND BOTTOM PLATES. PROVIDE 2X SOLID BLOCKING AT <br />3. <br />ALL REINFORCING SHALL BE SECURED IN PLACE PRIOR TO PLACING CONCRETE OR <br />MID -HEIGHT OF BEARING STUD WALLS. <br />2. <br />THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN THAT IT <br />GROUTING MASONRY. ALL REINFORCING SHALL BE CHAIRED TO ENSURE PROPER <br />CONFORMS TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL <br />CLEARANCES. SUPPORT OF FOUNDATION REINFORCING MUST PROVIDE ISOLATION FROM <br />2. SAWN LUMBER FRAMING SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING <br />INSPECTOR IS NOT AUTHORIZED TO APPROVE DEVIATIONS FROM THE DESIGN DRAWINGS OR <br />MOISTURE/CORROSION BY USE OF A PLASTIC OR CONCRETE CHAIR. DUCT -TAPE IS NOT <br />RULES OF THE WWPA OR THE WCLIB. ALL SAWN LUMBER SHALL BE STAMPED WITH THE <br />SPECIFICATIONS AND ALL DEVIATIONS MUST BE APPROVED BY THE ENGINEER OF RECORD <br />AN ACCEPTABLE MOISTURE/CORROSION PROTECTION. <br />GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY AND SHALL HAVE MINIMUM <br />PRIOR TO PROCEEDING WITH THE WORK. ALL REQUESTS FOR DEVIATIONS SHALL BE <br />PROPERTIES WHICH MEET OR EXCEED THE FOLLOWING WOOD TYPES: <br />INITIATED BY THE CONTRACTOR VIA A WRITTEN REQUEST FOR INFORMATION. <br />4. <br />REINFORCING STEEL SHALL BE SPLICED AS SHOWN OR NOTED. SPLICES AT OTHER <br />LOCATIONS SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER. ALL VERTICAL WALL <br />MEMBER WOOD TYPE <br />3. <br />THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL <br />REINFORCEMENT SHALL BE CONTINUOUS BETWEEN SPLICE LOCATIONS SHOWN IN THE <br />AND TO THE ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE <br />DRAWINGS. <br />JOISTS <br />IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED TO <br />2X4 (PANELIZED) D.F. SELECT <br />THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. <br />5. <br />ALL GRADE 60 REINFORCING TO BE WELDED SHALL BE ASTM A706. <br />2X4 D.F. #2 <br />2X6 OR LARGER D.F. #2 <br />4. <br />CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE SPECIAL INSPECTOR ACCESS TO ALL <br />6. <br />CLEAR CONCRETE COVERAGE IS AS FOLLOWS: <br />BEAMS <br />ITEMS REQUIRING SPECIAL INSPECTION. INSPECTOR IS NOT AUTHORIZED TO OPERATE <br />CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" <br />WIDTH OF 4" OR LESS D.F. #1 <br />CONTRACTOR'S EQUIPMENT. <br />EXPOSED TO EARTH OR WEATHER <br />#6 OR LARGER 2" <br />WIDTH GREATER THAN 4" D.F. SELECT <br />LEDGERS AND TOP PLATES D.F.#2 <br />5. <br />FOR ADDITIONAL INFORMATION ON SPECIAL STRUCTURAL INSPECTIONS, CONTACT THE <br />#5 AND SMALLER 1-1 /2" <br />ENGINEER OF RECORD PRIOR TO START OF CONSTRUCTION. <br />COLUMNS (TO TIES) 1-1 /2" <br />STUDS <br />BEAMS (TO STIRRUPS) 1-1/2" <br />2X4 D.F. STD <br />2X6 OR LARGER D.F. #2 <br />FLAT SLABS 3/4" <br />POSTS <br />WALLS SEE SCHEDULE AND OR DETAILS <br />4X4 D.F. #2 <br />ALL OTHER PER LATEST EDITION OF ACI 318 <br />6X6 OR LARGER D.F. SELECT <br />STRUCTURAL STEEL <br />3. GLU-LAMINATED BEAMS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: Fb = 2,400 <br />PSI, Fy = 240 PSI, E = 1,800,000 PSI. BEAMS CANTILEVERING OVER SUPPORTS SHALL <br />1. <br />THE LABOR, MATERIALS AND EXECUTION REQUIRED FOR ALL CONCRETE WORK AS <br />HAVE THE SPECIFIED MINIMUM PROPERTIES TOP AND BOTTOM. ALL BEAMS SHALL BE <br />INDICATED ON THE DRAWINGS SHALL BE IN ACCORDANCE WITH THOSE APPLICABLE <br />FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC <br />PORTIONS OF CHAPTER 22 OF THE LATEST ADOPTED EDITION OF THE CALIFORNIA <br />AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITO STAMP AND <br />BUILDING CODE. <br />CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. IN THE ABSENCE OF CAMBER SHOWN <br />ON THE PLAN, PROVIDE STANDARD CAMBER. STANDARD CAMBER IS DEFINED AS A <br />2. <br />STRUCTURAL STEEL NOT ENCASED IN CONCRETE SHALL BE SHOP PAINTED WITH <br />RADIUS OF CURVATURE EQUAL TO 2500 FEET. <br />TNEMEC99 METAL PRIMER OR APPROVED EQUIVALENT. <br />4. PLYWOOD SHALL BE APA "CDX" RATED SHEATHING OR BETTER AND SHALL BEAR THE <br />STAMP OF AN APPROVED TESTING AGENCY. LAY UP PLYWOOD WITH FACE GRAIN <br />3. <br />UNLESS NOTED OTHERWISE, ALL BOLTS SHALL BE ASTM A307. THIS INCLUDES <br />PERPENDICULAR TO SUPPORTS. (ON ROOFS WHERE PLYWOOD IS LAYED UP WITH FACE <br />EXPANSION/ADHESIVE ANCHORS. BOLTED CONNECTIONS SHALL CONFORM TO AISC <br />GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD). STAGGER JOINTS. <br />SPECIFICATIONS UNLESS NOTED OTHERWISE ON THE DRAWINGS. <br />ALL NAILING SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE. WHERE SCREWS ARE <br />INDICATED FOR WOOD TO WOOD ATTACHMENTS, USE WOOD SCREWS. ALL PLYWOOD <br />4. <br />UNLESS NOTED OTHERWISE ALL WELDS PER THE LATEST EDITIONS OF THE AWS <br />SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATIO AND SHALL BE <br />STANDARDS SHALL CONFORM TO AISC SPECIFICATIONS. WELDING SHALL BE PERFORMED <br />ATTACHED AS FOLLOWS UNLESS NOTED OTHERWISE. <br />BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE <br />TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. THESE DRAWINGS DO NOT <br />USE THICKNESS SPAN/INDEX ATTACHMENT INTERMEDIATE <br />DISTINGUISH BETWEEN SHOP AND FIELD WELDS. <br />RATIO EDGE <br />5. <br />CONTRACTOR IS PERMITTED TO CUT AND WELD ANTENNA SUPPORT ASSEMBLY ARMS AS <br />ROOF 5/8" 32/16 1Od@6" O.C. 10d@12" O.C. <br />NECESSARY TO MEET THE LENGTH REQUIREMENTS IN THE FIELD. WELDS SHALL CONSIST <br />ROOF 3/4" 40/20 1Od@6" O.C. 10012" O.C. <br />OF A 3/16" FILLET ALL THE WAY AROUND FOR 1/4" THICK STEEL OR LESS AND 3/8" <br />LESS. SHALL RESTORE <br />FLOOR 3/4" 40/20 SCREWS@6" O.C. SCREWS@12" O.C. <br />ffY O �=R� ERE T <br />FILLET WELD FOR STEEL 1/2" THICK OR CONTRACTOR <br />SHEAR WALL 3/8" 24/0 8d@6" O.C. 8d@12" O.C. <br />{� <br />CORROSION BARRIER WITH AN APPROVED PAINT IN ACCORDANCE WITH BS 729-1971 AND <br />REVIEWED �:I��Iu <br />PREN 1029." <br />SbckT 'i e r <br />0 <br />iro' <br />�1 <br />1855 GATEWAY BLVD. SUITE 900 <br />CONCORD, CA 94520 <br />1-1iUJLUI IINrUKIVIP IUIN: <br />CROWN BU: 825709 <br />SITE NUMBER <br />S¢ 1 B <br />NAME:k <br />MASONICITE 1TE <br />0 01 . � <br />CURRENT ISSUE DATE; <br />04/05/22 <br />A <br />10/06/2021 <br />90% CONSTRUCTION <br />BAK <br />0 <br />03/21 /2022 <br />100% CONSTRUCTION <br />BAK <br />A100% <br />i <br />04/05/22 <br />CD: REVISED <br />PER CLIENT RL <br />ROY <br />:PLANS PREPARED BY: <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 Fax: (818) 840-0708 <br />:CONSULTANT: <br />2500 Red Hill Ave., #220, Santa Ana, CA 92705 <br />Office: (949) 202-4913 Fax: (818) 840-0708 <br />DRAWNBY:BY <br />PLR AM AM <br />rLICENSURE: <br />SHEET TITLE: <br />L_1-,l-aFP_T 1\II IKARF-R° <br />CHK.: APV.: <br />RVII:�I0N- <br />