19
<br />EXCAVATION NOTES
<br />1. EXCAVATE TO ELEVATIONS, LINES AND GRADES INDICATED TO NOT MORE THAN 1/2—INCH ABOVE OR BELOW THAT
<br />REQUIRED.
<br />2. SLOPE SIDES OF EXCAVATION AS INDICATED OR COMPLY WITH LOCAL CODES AND ORDINANCES HAVING JURISDICTION,
<br />WHICHEVER IS MORE STRINGENT. SHORE AND BRACE WHERE SLOPING IS NOT POSSIBLE BECAUSE OF SPACE
<br />RESTRICTIONS OR STABILITY OF MATERIAL EXCAVATED.
<br />3. STOCKPILE SATISFACTORY EXCAVATED MATERIALS AS REQUIRED FOR BACKFILL OR FILL. PLACE, GRADE AND SHAPE
<br />STOCKPILES FOR PROPER DRAINAGE. LOCATE AND RETAIN SOIL MATERIALS AWAY FROM EDGE OF EXCAVATIONS.
<br />4. DISPOSE OF EXCESS SOIL AND UNSUITABLE SOIL MATERIAL OFF —SITE AS DIRECTED.
<br />SHORINGTRENCH
<br />TEMPORARY SHORING OF TRENCHING FOR UTILITIES DUE TO POOR GROUND CONDITIONS AND HIGH GROUND WATER
<br />CONDITIONS IS EXPECTED. PROVIDE SHORING BASED UPON GEOTECHNICAL REPORT LATERAL PRESSURES ON SHORING
<br />WALLS.
<br />STRUCTURAL ILL REQUIREMENTS
<br />STRUCTURAL FILL SHALL BE GRAVEL BORROW CONFORMING TO WSDOT STANDARD SPECIFICATION 9-03.14(1) WITH THE
<br />EXCEPTION THAT THE NO. 200 SIEVE SIZE PERCENT PASSING IS 5.0% MAX. IN LIEU OF 7.0 MAX.
<br />OR
<br />RECYCLED CRUSHED CONCRETE CONFORMING TO WSDOT SPECIFICATION FOR GRAVEL BORROW OR APPROVED EQUAL.
<br />RECYCLED CRUSHED CONCRETE SHALL NOT BE INSTALLED BELOW THE ORDINARY HIGH WATER LEVEL OF THE
<br />SNOHOMISH RIVER ADJACENT TO THE SITE OR WITHIN THE HIGHEST LEVEL OF THE SEASONAL GROUNDWATER
<br />ELEVATION.
<br />COMPACTION
<br />GENERAL
<br />WHERE SUBGRADE OR LAYER OF SOIL MATERIAL MUST BE MOISTURE CONDITIONED BEFORE COMPACTION, UNIFORMLY
<br />APPLY WATER TO SURFACE OF SUBGRADE OR LAYER OF SOIL MATERIAL TO PREVENT FREE WATER APPEARING ON
<br />SURFACE RUING OR SUBSEQUENT TO COMPATION OPERATIONS. REMOVE AND REPLACE OR SCARIFY AND AIR DRY, SOIL
<br />MATERIAL THAT IS TOO WET TO PERMIT COMPACTION TO SPECIFIED DENSITY. SOIL MATERIAL THAT HAS BEEN
<br />REMOVED BECAUSE IT IS TOO WET TO PERMIT COMPACTION MAY BE STOCKPILED OR SPREAD AND ALLOWED TO DRY.
<br />ASSIST DRYING BY DISKING, HARROWING OR PULVERIZING UNTIL MOISTURE CONTENT IS REDUCED TO SATIFACTORY
<br />VALUE.
<br />THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT THE PREPARED AND APPROVED SUBGRADE FROM TRAFFIC,
<br />WATER RUN—ON, STANDING WATER, OR OTHER DAMAGE. SUBGRADE THAT HAS BEEN OVER COMPACTED, SHALL BE
<br />SCARIFIED TO A MINIMUM DEPTH OF EIGHT (B) INCHES AND RECOMPACTED,
<br />PIPE/TRENCH BACKFILL TESTING/INSPECTION REQUIREMENTS
<br />GEOTECHNICAL ENGINEER WILL EVALUATE THE ADEQUACY OF THE SUBGRADE SOILS AND IDENTIFY ANY AREAS NEEDING
<br />FURTHER WORK, PERFORM IN —PLACE MOISTURE —DENSITY TESTS TO DETERMINE IF THE WORK IS BEING DONE IN
<br />COMPLIANCE WITH THE COMPACTION SPECIFICATIONS AND THE INTENT OF THE RECOMMENDATIONS, AND ADVISE ON
<br />ANY MODIFICATIONS TO PROCEDURE WHICH MIGHT BE APPROPRIATE FOR THE PREVAILING CONDITIONS.
<br />GENERAL TRENCH EXCAVATION, PIPE BEDDING, AND TRENCH BACKFILLING SHOULD BE COMPLETED USING THE GENERAL
<br />PROCEDURES DESCRIBED IN WSDOT STANDARD SPECIFICATIONS, SECTION 7-17, OR OTHER SUITABLE PROCEDURES
<br />APPROVED BY THE PROJECT CIVIL ENGINEER, AS LONG AS IT MEETS OR EXCEEDS CITY STANDARDS..
<br />UTILITY PIPES SHOULD BE BEDDED IN SAND OR SMOOTH ROUNDED GRAVEL, SUCH AS SPECIFIED IN THE CITY OF
<br />EVERETT TYPICAL TRENCH SCHEMATIC DETAILS, WSDOT STANDARD SPECIFICATIONS, SECTION 9-03.12(3) AS MODIFIED
<br />FOR SANITARY SEWERS, OR AS RECOMMENDED BY THE MANUFACTURER, AS LONG AS IT MEETS OR EXCEEDS CITY OF
<br />EVERETT STANDARDS. PIPE TO BE COVERED WITH BEDDING MATERIAL TO AT LEAST ONE FOOT ABOVE THE PIPE.
<br />THIS BEDDING MATERIAL SHOULD BE LIGHTLY TAMPED INTO PLACE. BACKFILL PLACED ABOVE THE BEDDING MATERIAL
<br />SHALL CONSIST OF STRUCTURAL FILL
<br />PLACED IN LIFTS NOT EXCEEDING 10 INCHES IN LOOSE THICKNESS AND MECHANICALLY COMPACTED AS SPECIFIED
<br />BELOW, OR AS MODIFIED BY THE ON —SITE GEOTECHNICAL ENGINEER,
<br />COMPACTION CRITERIA: USING THE MODIFIED PROCTOR TEST (ASTM: D-1557) AS A STANDARD, STRUCTURAL FILL
<br />USED FOR VARIOUS ONSITE APPLICATIONS SHALL BE COMPACTED TO THE FOLLOWING MINIMUM DENSITIES:
<br />FILL APPLICATION MINIMUM COMPACTION
<br />PIPE SUPPORT PAD 95 PERCENT OR IN
<br />ACCORDANCE WITH
<br />MANUFACTURERS SPECIFICATIONS
<br />TRENCH BACKFILL — 4 FEET 90 PERCENT OR IN
<br />OR DEEPER BELOW FINISH GRADE ACCORDANCE WITH
<br />MANUFACTURERS SPECIFICATIONS
<br />TRENCH BACKFILL — WITHIN 4 FEET 95 PERCENT
<br />OF FINISH GRADE
<br />SUBGRADE OBSERVATION AND TESTING REQUIREMENTS
<br />REGARDLESS OF MATERIAL OR LOCATION, ALL STRUCTURAL FILL SHOULD BE PLACED OVER FIRM, UNYIELDING
<br />SUBGRADES PREPARED IN ACCORDANCE WITH THE SITE PREPARATION SECTION OF THE GEOTECHNICAL REPORT. THE
<br />CONDITION OF ALL SUBGRADES SHOULD BE OBSERVED BY GEOTECHNICAL ENGINEER BEFORE FILLING OR CONSTRUCTION
<br />BEGINS. ALSO, FILL SOIL COMPACTION SHOULD BE VERIFIED BY MEANS OF IN —PLACE DENSITY TESTS PERFORMED
<br />DURING FILL PLACEMENT SO THAT ADEQUACY OF SOIL COMPACTION EFFORTS MAY BE EVALUATED AS EARTHWORK
<br />PROGRESSES.
<br />WATER SETTLING AND JETTING OF BACKFILL MATERIAL ARE NOT ACCEPTABLE, MECHANICAL METHODS SHALL BE
<br />UTILIZED FOR PLACEMENT AND COMPACTION OF A BACKFILL MATERIAL UNLESS OTHERWISE APPROVED IN WRITING BY
<br />THE CITY OF EVERETT.
<br />THE MINIMM ALLOWABLE TRENCH COMPACTION TESTING FREQUENCY ARE:
<br />SHALLOW TRENCH ZONES (TRENCH DEPTH LESS THAN 6 FEET) SHALL BE A MINIMUM OF ONE (1) FIELD DENSITY TEST
<br />FOR EVERY 100 LINEAL FEET OF TRENCH. SHOULD SOILS BE INCONSISTEN IN GRADATION AND HOE PACS ARE USED
<br />FOR TRENCH COMPACTION, PROFESSIONAL JUDGMENT AND OBSERVATIONS BY THE DEVELOPERS'S GEOTECHNICAL
<br />ENGINEER SHALL BE UTILIZED TO DETERMINE COMPACTION ACCEPTABILITY.
<br />DEEP TRENCH ZONES (TRENCH DEPTH GREATER THAN 6 FEET), PROVIDE IN PLACE DENSITY TESTS AT MID TRENCH
<br />DEPTH AND A SUBGRADE ELEVATION, MINUMUM OF ONE (1) FIELD DENSITY TEST AT EACH ELEVATION TEST PER 100
<br />LINEAL FEET OF TRENCH. THE CONTRACTOR SHALL PROVIDE A SAFE TRENCH FOR THE TESTING AGENCY PERSONNEL
<br />TO PERFORM THE COMACTION TESTS.
<br />UTILITY STRUCTURES SHALL HAVE A MINUMUM OFTWO (2) IN PLACE DENSITY TEST WITHIN BACKFILL AREA ADJACENT
<br />TO EACH MANHOLE, CATCH BASIN, VAULT AND OTHER UTILITY STRUCTURES.
<br />IF ADDITIONAL TESTING IS REQUIRED DUE TO FAILURE OF AREAS TESTED, THE CONTRACTOR SHALL PAY FOR SURCH
<br />RETESTING BY THE OWNER'S TESTING AGENCY.
<br />TRUCK NOT a 1' HEAVY COMPACTORPRESENCE OF THE cEOTECHNICAL
<br />ENGINEER, DO NOT PROOF ROLL WET OR SATURATED SUBGRADES. LIMIT VEHICLE SPEED TO THREE MPH. ANY
<br />LOCALIZED i OF •• i DISCLOSED DURING • i '1 OPERATION i i BE OVER
<br />EXCAVATED TO A MINIMUM DEPTH OF 12 INCHES AND REPLACED WITH A SUITABLE STRUCTURAL FILL MATERIAL. ALL
<br />STRUCTURAL BE COMPACTED ACCORDING TO THE RECOMMENDATIONS PROVIDED ABOVE. REPLACINGM
<br />RECOMPACTING SOILS WILL BE INCIDENTAL TO FILL AND BACKFILL WORK. THE SOIL WILL BE RETESTED AND MUST
<br />PASS,SUBSEQUENT PROOF i SPECIFICALLY,APE is SOILS UNDERLYING
<br />PROGRESSING.SHOULD BE COMPACTED TO AT LEAST 95 PERCENT (BASED ON ASTM D-1557. SHOULD THE SUBGRADE SURFACE OF
<br />THE PROOF ROLL TESTED AREA NOT DEFLECT, IT WILL BE CONSIDERED ACCEPTABLE AND WORK MAY CONTINUE
<br />COMPACTION AND OBSERVATION: ALL B AND BASE COURSE MATERIAL SHOULD BE COMPACTED O AT LEAST
<br />SHOULD95 PERCENT OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D-1557), AND ALL ASPHALT CONCRETE
<br />`; D TO AT a 92 PERCENT OF A A i i i •
<br />SHALL i i i C • COMPACTION iBEFORE OVERLYING LAYER PLACED.
<br />FOR THE SUBBASEPAVEMENT COURSE,COMPACTION BEST OBSERVED BY aFREQUENT
<br />w THE BASE METHODOLOGY OBSERVATIONS it HAND—PROBINARE MORE APPROPRIATE THa
<br />DENSITY
<br />ROADWAY.SUBBASE COURSE INPLACE DENSITY TESTING SHALL BE A MINIMUM OF FOUR TESTS PER 100 LINEAL FEET OF
<br />THE DEVELOPER SHALL OBTAIN THE SERVICES OF A GEOTECHNICAL ENGINEER LICENSED IN THE STATE OF WASHINGTON
<br />TO BE ONSITE FOR SOIL ACCOUNTABILITY AND COMPACTION DURING EXCAVATION ON A PART TIME OR FULL TIME
<br />BASIS AS NECESSARY. THE CONTRACTOR SHALL FOLLOW GEOTECHNICAL RECOMMENDATION AS INCLUDED IN THE
<br />GEOTECHNICAL REPORT BY THE MIGIZI GROUP DATED FEBRUARY 7, 2020,
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEWATERING ALL EXCAVATIONS. ALL WATER GENERATED FROM
<br />DEWATERING OPERATIONS SHALL BE DESPOSED OR IN MANNER AND LOCATION APPROVED BY THE CITY OF EVERETT.
<br />THE CONTRACTOR SHALL PREPARE A DEWATERING PLAN AND HAVE A AN ON—STIE MEETING WITH THE PUBLIC WORKS
<br />'INSPECTORS TO GO OVER THE DEWATERING PLAN PRIOR TO TRENCHING. THE DEWATERING PLAN SHALL BE AVAILABLE
<br />ON —SITE AT ALL TIMES AND UPDATED AS NEEDED TO REFLECT THE CONSTRUCTION CONDITIONS. THE DEWATERING
<br />PLAN SHALL INCLUDE APPROPRIATE SHORING, BASED UPON SOIL CONDITIONS AND THE DEWATERING PROCESS.
<br />SHORING SHALL CONFORM TO ALL SAFETY STANDARDS AS REQUIRED BY LOCAL AND STATE JURISDICTIONS.
<br />ALL GROUNDWATER OR INCIDENTAL SURFACE RUNOFF COLLECTED SHALL BE DISCHARGED TO THE ON —SITE
<br />STORMWATER SYSTEM FOLLOWING APPROPRIATE TREATMENT UNTIL CONSTRUCTION IS COMPLETE.
<br />NO SEDIMENT, TURBID WATER, OTHER POLLUTANTS (HEAVY METALS, OIL SHEEN, ETC.) SHALL BE DISCHARGED TO THE
<br />ON -SITE STORWATER SYSTEM. ANY TREATMENT OF COLLECTED WATER SHALL BE APPROVED BY THE DITY OF
<br />EVERETT PRIOR TO DISCHARGE.
<br />A LOG OF ALL DISCHARGED STORMWATER SHALL BE KEPT ON —SITE AT ALL TIMES DURING CONSTRUCTION. AT A
<br />MINIMUM, THE LOG SHALL CONTAIN THE FOLLOING ITEMS:
<br />a DATE DISCHARGED
<br />® SOURCE OF WATER (VAULT, PIPE, ETC.)
<br />® TYPE OF WATER DISCHARGED (GROUNDWATER, STORMWATER, ETC.)
<br />® METHOD OF COLLECTION (PUMP TO TANK, ETC.)
<br />a METHOD OF DISCHARGE (DRAIN FROM TANK, PUMPED DISCHARGE, ETC.)
<br />® VOLLME OF WATER DISCHARGED
<br />9 DISCHARGE LOCATION
<br />® RECEIVING SYSTEM (ON —SITE STORM SYSTEM, SEWER, OFF —=SITE FACILITY, ETC.)
<br />® DURATION OF DISCHARGE,
<br />ANY STORWATER COLLECTED INTO A TRUCK SHALL NOT BE DISCHARGED TO THE STORWATER SYSTEM.
<br />SITE EXPLORATIONS ENCOUNTERED GROUNDWATER SEEPAGE AT A DEPTH OF APPROXIMATELY 7 TO 10 FEET BELOW
<br />EXISTING GRADE. THE MAJORITY OF THE SOILS ENCOUNTERED ON —SITE ARE SILTY, GRANULAR ALLUVIAL SOILS, WHICH
<br />COULD POTENTIALLY BE WATER BEARING DURING WINTER MONTHS. THE CONTRACTOR SHOULD BE PREPARED TO DEAL
<br />WITH THIS CONDITION.
<br />FOR SHALLOW EXCAVATIONS ABOVE THE WATER TABLE, SHOULD GROUNDWATER BE ENCOUNTERED, IT IS ANTICIPATED
<br />THAT AN INTERNAL SYSTEM OF DITCHES, SUMP HOLES, AND PUMPS WILL BE ADEQUATE TO TEMPORARILY DEWATER
<br />EXCAVATIONS. FOR DEEPER EXCAVATIONS BELOW THE WATER TABLE, MORE EXTENSIVE DEWATERING EQUIPMENT, SUCH
<br />AS WELL POINTS, COULD BE NECESSARY IN ORDER TO TEMPORARILY DEWATER EXCAVATIONS. THE APPROPRIATE
<br />DEWATERING SYSTEM WILL BE DETERMINED BY THE CONTRACTOR DURING CONSTRUCTION, WHEN THE SPECIFIC
<br />SUBGRADE CONDITIONS ENCOUNTERED iN THE PIPE TRENCH ARE DIRECTLY OBSERVABLE. CONTRACTOR SHOULD BE
<br />PREPARED FOR MORE EXTENSIVE DEWATERING AT THAT TIME SHOULD IT BE NEEDED.
<br />TV INSPECTION OF STORM AND SEWER PIPING
<br />ALL NEW STORM AND SEWER MAINS WITHIN THE PUBLIC RIGHT--OF--WAY AND THOSE IN EASEMENTS TO BE MAINTAINED
<br />BY THE CITY WILL BE SUBJECT TO A VISUAL INSPECTION WITH A TV CAMERA UNIT. THE CONTRACTOR SHALL
<br />PERFORM THE TV INSPECTION AND PROVIDE A CD OF THE VIDEO TO EVERETT PERMIT SERVICES TO BE REVIEWED BY
<br />THE CITY SEWER AND DRAINAGE DIVISION. ANY DEFICIENCIES NOTED BY THE TV CAMERA INSPECTION SHALL BE
<br />CORRECTED TO THE STATISFACTION OF THE CITY UTILITIES DIVISION.
<br />IT SHALL BE THE RESPONSIBILITY OF THE CONTACTOR TO FURNISH MATERIALS AND INSTALL MONUMENTS AND
<br />CASTINGS IN ACCORDANCE WITH THE DRAWINGS AND WHERE DIRECTED BY THE ENGINEER. ALL SURVEY WORK SHALL
<br />BE PERFORMED BY OR UNDER THE DIRECT SUPERVISION, OF A PROFESSIONAL LAND SURVEYOR (PLS) LICENSED IN THE
<br />STATE OF WASHINGTON. MONUMENT AND MONUMENT CASE AND COVER SHALL BE SUPPLIED AND INSTALLED PER CITY
<br />OF EVERETT STANDARD DRAWING 323 AND 324. EACH MONUMENT SHALL BE RECORDED ON THE CITY'S SURVEY
<br />RECORD FORM AND SUBBMITTED WITH THE PROJECT AS—BUILTS.
<br />SURVEYING, AS REQUIRED TO CONSTRUCT A GIVEN PROJECT PER THE APPROVED PLANS, SHALL BE FURNISHED BY
<br />THE DEVELOPER AT NO EXPENSE TO THE CITY. IT IS REQUIRED THAT SURVEY STAKES BE SET FOR NEW CURB AND
<br />GUTTER CONSTRUCTION, FOR BOTH HORIZONTAL AND VERTICAL CONTROL. ADDITIONALLY, ANY WATER, STORM DRAIN,
<br />OR SANITARY SERWER MAINS WHICH ARE TO BE CONSTRUCTED IN EASEMENTS ARE TO HAVE SURVEY OFFSET STAKES
<br />SET PRIOR TO STARTING WORK, AND ANY DEVIATION FROM THAT STAKED LINE MUST BE LEFT UNCOVERED AND
<br />RESURVEYED TO REALIGN EASEMENT AS REQUIRED AND FOR CORRECTED AS —BUILT INFORMATION.
<br />MONUMENTS SHALL BE LOCATED AT ALL CENTERLINE INTERSECCTIONS OF INTERSECTING STREETS. CURVED STREETS
<br />SHALL BE MONUMENTED AT CENTERLINE PI'S (POINT OF INTERSECTION), IF IT FALLS WITHIN THE STREET PAVEMENT,
<br />OTHERWISE THE PC (POINT OF CURVATURE) AND PT (POINT OF TANGENCY) OF THE CURVE SHALL BE MONUMENTED.
<br />IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE SURVEYING REUIRED TO EXTABLISH OR PERPETUATE
<br />LAND CONER MONUMENTATION AS MAY BE REQUIRED ON THE PROJECT. REFER TO THE CITY OF EVERETT 'DESIGN
<br />AND CONSTRUCTION STANDARDS AND SPECIFICATIONS', VOLUME 1, SECTION 3-10.3,CONSTRUCTION REQUIREMENTS FOR
<br />LAND CORNER SURVEYING, REPLACING AND RESTORING AN EXISTING OR OBLITERATED GLO CORNER(S), AND FILING
<br />LAND CORNER RECORDS FOR THESE MONUMENTS, AND CERTIFICATION LETTER. IF UNACCEPTABLE ERRORS ARE FOUND
<br />DUE TO ERRORS OR OMISSIONS BY THE CONTRACTOR'S SURVEY ACTIVITIES, THEN THE CONTRACTOR SHALL CORRECT
<br />THESE ERRORS INCLUDING REMOVING AND REPLACING IMPROVEMENTS AND PAY ALL EXPENSES INCURRED BY THE CITY
<br />INCLUDING THE RE —SURVEY.
<br />PRIOR TO THE ACCEPTANCE OF THE WORK BY THE CITY OF EVERETT, THE CONTRACTOR SHALL FURNISH THE CITY
<br />ENGINEER ONE NEATLY AND LEGIBLY MARKED SET OF THE CITY APPROVED, WET STAMPED PLOTTER PAPER DRAWINGS
<br />OF SIGNIFICANT PERMANENT ITEMS SHOWING ANY AND ALL CHANGES IN THE FINAL LOCATIONS OF ALL ITEMS OF WORK
<br />INCLUDING, BUT NOT LIMITED TO, CURB AND GUTTER, STORM DRAIN LINES, WATER LINES, SEWER LINES, CATCH BASINS,
<br />MANHOLES, FIRE HYDRANTS, VALVES, NEW AND EXISTING UTILITIES AND ALL OTHER MISCELLANEOUS ITEMS INCLUDED IN
<br />THE WORK. MARKING OF THE DRAWINGS SHALL REPRESENT ALL CHANGES, VERTICAL AND HORIZONTAL, AND BE DONE
<br />AT THE TIME THE MATERIAL AND EQUIPMENT IS INSTALLED. PROVIDE THE CITY WITH A ONE HARD COPY OF THE
<br />AS-BUILTS TURNED 1N WITH A CITY OF EVERETT PERMIT COUNTER TRANSMITTAL FORM. THE INSPECTOR WILL REVIEW
<br />AND STAMP WITH RECORD DRAWING STAMP/INSPECTOR SIGNATURE.
<br />AS -BUILT DRAWINGS SHALL BE CONSIDERED AN ITEM ON THE CONTRACTOR'S PUNCH LIST.
<br />AFTER APPROVAL, THE CONSTRUCTION PERMIT CAN BE FINALED/CLOSED OUT.
<br />WARRANTY BOND
<br />A WARRANTY BOND IS REQUIRED i BE AAND THE SYSTEM
<br />WILL i REMAINOWNER/CONTRACTOR'S
<br />�ESPONSIBILITY DURING THE WARRANTY TIME PERIOD, AND IS THEN TURNEOVER TO THE CITY OF EVERETT FOR
<br />OWNERSHIP AND MAINTENANCE OF ,,, OF i CONSTRUCTION
<br />STANDARDS, CHAPTER 1 FOR MORE INFORMATION).
<br />m
<br />w
<br />w
<br />ui
<br />0
<br />v
<br />m
<br />U)
<br />CC C>
<br />00
<br />cn
<br />iZ
<br />N
<br />cn
<br />0
<br />U)
<br />C
<br />J
<br />0
<br />a
<br />0
<br />0
<br />vi
<br />121
<br />cn
<br />®
<br />cl
<br />co
<br />o
<br />9
<br />co
<br />w
<br />V
<br />z
<br />0�
<br />F-
<br />U)
<br />U)
<br />w
<br />U)
<br />z
<br />fn
<br />a
<br />wLU
<br />o
<br />CL
<br />Ld
<br />C
<br />(L
<br />�.
<br /><
<br />t.
<br />r
<br /><
<br />I
<br />4..
<br />is
<br />Lo
<br />m
<br />�_„
<br />(o
<br />_.
<br />0Ld
<br />o
<br />}
<br />,1
<br />x_
<br />g
<br />r
<br />(
<br />miz
<br />',
<br />�!
<br />dcn
<br />4_"
<br />£
<br />rr
<br />•
<br />If i..
<br />SHEET NO.
<br />C002
<br />
|