Laserfiche WebLink
n +tt• R7111-033 <br />SITE INFORMATION <br />Parcel Number(s): 29051700102300 <br />Legal Description(s): <br />Section 17 Township 29 Range 05 Quarter NE - <br />BEG SW COR LOT 10 PLAT HAWTHORNE HGTS TH SLY & PLT & 140.5 FT WLY SD <br />W LN HAWTHORNE ST 100 FT M/L TO INT WH A LN WH IS 90 FT WLY AT R/A FIR W <br />LN MAPLE ST TH SWLY PLT W LN MAPLE ST 120 FT M/L TO INT SW BDY TR <br />CONV P C HEGGE ET UX 431/WD/12 TH N29*32 48 W 200 FT M/L ALG SD SW BDY <br />SD HEGGE TR TAP WH BEARS S60*27 12W FIR POB TH N60*27 12E 65 FT M/L TO <br />POB TGW TH PTN BEG INT VAC MAPLE ST & MOST SELY COR LOT 10 PLAT <br />HAWTHORN HGTS TH WLY ALG SLY MGN SD LOT FOR 144.06FT M/L TO SW COR <br />SD LOT TH SLY & PLT & 140.5 FT WLY OF WILY LN HAWTHORN ST 100 FT M/LTO <br />INT WITH A LN WH IS 90 FT WLY AT R/A FIR W LN VAC MAPLE ST TH SWLY PLT W <br />LN OF VAC MAPLE ST 120FT M/L TO INT OFSWLY BDY TR CONV P C HEGGE ET <br />UX 431/ WD/12 TH SELY ALG SD WILY BDY SD HEGGE TR 115FTM/L TO W LN VAC <br />MAPLE ST TH NLY ALG W LN SD VAC MAPLE ST 350FT M/L TO POB TGW TH PTN <br />NW1/4 NE1/4 DAF - BEG INT N LN 9TH ST & E LN MAPLE ST PRODN TH W ALG N <br />LN 9TH ST 40FT TH N ALG C/L SD MAPLE ST PROD163.22FT TH W 40FT TO INT W <br />LN MAPLE ST PROD TH N ALG SD W LN 389.35FT TO SE COR LOT 10 <br />HAWTHORNE HTS ADD TH E AT R/A TO SWLY MGN HAWTHORNE ST TH SELY <br />ALG SD SWLY MGN HAWTHORNE ST TO INT N LN SD 9THST TH W ALG SD N LN <br />9TH ST TO POB TGW W 1 OFT HAWTHORNE ST ABTG & VAC PER ORD 3246 REC <br />5-31-41 AF 917761 <br />`�T/J 3015 9TH ST. <br />0 <br />Im <br />A,' <br />PR <br />STAIRS / RAMP FOUNDATION NOTES: <br />1. EXTERIOR FOOTINGS SHALL BEAR A MIN OF V-6" BELOW ADJACENT <br />GRADE OR AS NOTED ON PLAN. <br />2. FOOTINGS SHALL BEAR ON FIRM NATIVE SOIL OR COMPACTED <br />STRUCTURAL FILL. <br />3. CONCRETE COMPRESSIVE STRENGTH SHALL BE fc = 3,000 PSI. <br />4. REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING <br />TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI). <br />STAIRS / RAMP FRAMING NOTES: <br />1. UNLESS NOTED OTHERWISE, ALL WOOD AND WOOD -BASED MEMBERS <br />EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR <br />WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE <br />IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. <br />2. ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER <br />MANUFACTURER'S RECOMMENDATIONS. <br />3. UNLESS NOTED OTHERWISE, ALL BEAM -TO -COLUMN CONNECTIONS SHALL <br />BE SIMPSON CC OR ECC SERIES COLUMN CAPS. STRINGER -TO -COLUMN <br />CONNECTIONS SHALL BE SIMPSON HUC SLOPED HANGER U.N.O. <br />4. UNLESS NOTED OTHERWISE, ALL JOIST -TO -BEAM CONNECTIONS SHALL BE <br />SIMPSON LU SERIES FACE MOUNT HANGERS, <br />5. COLUMNS SHOWN ON PLAN ARE BELOW FRAMING LEVELS INDICATED. <br />6. UNLESS NOTED OTHERWISE, ALL (2)2x MEMBERS WHERE CALLED OUT ON <br />PLAN SHALL BE FASTENED TOGETHER WITH (2) ROWS OF 10d NAILS @ 12" OC <br />STAGGERED. <br />7. HURRICANE TIES SHALL BE PROVIDED AT ALL NEW ROOF RAFTER AND ROOF <br />BEAM CONNECTIONS PER ROOF FRAMING DETAILS. <br />HANDRAIL AND GUARDRAIL NOTES: <br />1. PREFABRICATED GUARDRAIL SYSTEMS SHALL BE A DEFFERED (SAVED <br />UNTIL LATER) SUBMITTAL, WITH DRAWINGS AND CALCULATIONS SUBMITTED TO <br />THE DESIGNER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO <br />FABRICATION AND INSTALLATION. <br />2. GUARDRAIL LOADING CRITERIA: <br />HANDRAILS AND GUARDRAILS SHALL BE DESIGNED TO RESIST A LINEAR <br />LOADING OF 50 POUNDS PER LINEAR FOOT, AND 200 LBS CONCENTRATED <br />LOAD, INTERMEDIATE RAILS SHALL BE DESIGNED TO RESIST A CONCENTRATED <br />LOAD OF 50 LBS., IN ACCORDANCE W/ SECTION 4.5.1.1 OF ASCE7. <br />EXISTING BUILDING CODE INFORMATION <br />REPAIRS PROPOSED IN THIS PROJECT SHALL MEET THE PERFORMANCE <br />COMPLIANCE MEASURES DESCRIBED IN CHAPTERS 4, 5 AND 7 OF THE <br />INTERNATIONAL EXISTING BUILDING CODE, 2018 EDITION. <br />THE SCOPE OF WORK ENTAILS REPAIRS TO EXISTING CLADDING SYSTEMS AND <br />DOES NOT INCLUDE STRUCTURAL REPAIRS, OR ADDITIONS TO THE EXISTING <br />BUILDING. <br />ALTERATIONS SHALL MEET THE DEFINITIONS OF LEVEL 1 ALTERATIONS, PER <br />IEBC SECTION 602.1. REMOVAL AND REPLACEMENT OF EXISTING MATERIALS <br />USING NEW MATERIALS THAT SERVE THE SAME PURPOSE. <br />701.4 EXISTING EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL <br />REMAIN OPERATIONAL. <br />702.4, 702.5 WINDOWS. WINDOW REPLACEMENT IS NOT INCLUDED IN <br />THIS PROJECT. <br />702.6 ALTERATIONS ( NEW SYSTEMS AND MATERIALS) SHALL MEET <br />REQUIREMENTS OF IBC, AND OTHER APPLICABLE CODES. <br />703 FIRE PROTECTION FIRE RESISTANCE RATINGS OF EXISTING <br />ASSEMBLIES SHALL REMAIN INTACT, OR BE REPAIRED AS REQUIRED. <br />706 STRUCTURAL. STRUCTURAL REPAIRS ARE NOT REQUIRED, OR <br />INTENDED TO BE PART OF THIS PROJECT. <br />707 ENERGY CONSERVATION: LEVEL 1 ALTERATIONS DO NOT REQUIRE <br />COMPLIANCE WITH THE ENERGY CODE. <br />BUILDINGS SHALL REMAIN OCCUPIED DURING REPAIRS. PROVIDE SAFEGUARDS <br />DURING CONSTRUCTION IN ACCORDANCE WITH IEBC CHAPTER 15. <br />1501.2. EQUIPMENT AND MATERIALS SHALL BE STORED AND PLACED <br />SO AS NOT TO ENDANGER THE PUBLIC, WORKERS, OR ADJACENT <br />PROPERTIES. <br />1501.3 REQUIRED EXITS, STRUCTURAL ELMENTS, FIE PROTECTION <br />DEVICES AND SANITARY SAFEGUARDS SHALL BE MAINTAINED AT ALL <br />TIMES DURING ALTERATIONS. <br />1501.4 WASTE MATERIALS SHALL BE REMOVED IN A MANNER WHICH <br />PREVENTS INJURY TO PERSONS, PROPERTIES OR TO ADJACENT <br />RIGHTS OF WAY. <br />1501.5 FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH <br />APPLICABLE REQUIREMENTS OF THE IBC, AND CHAPTER 33 OF THE IFC. <br />1501.6 PEDESTRIANS SHALL BE PROTECTED DURING CONSTRUCTION <br />AND DEMOLITION ACTIVITIES WITH WALKWAYS, BARRICADES, <br />BARRIERS, RAILINGS, AND OTHER MEANS DESCRIBED IN THE CODE. <br />1502. ADJOINING PUBLIC AND PRIVATE PROPERTY SHALL BE <br />PROTECTED DURING CONSTRUCTION AND DEMOLITION WORK. <br />1503. TEMPORARY USE OF STREETS, ALLEYS, AND PUBLIC PROPERTY. <br />TEMPORARY USE OF PUBLIC PROPERTY SHALL BE AS PERMITTED AND <br />AGREED UPON BY THE CITY OF EVERETT. <br />1504 FIRE EXTINGUISHERS. PROVIDE FIRE EXTINGUISHERS DURING <br />CONSTRUCTION AS FOLLOWS: <br />AT EACH STAIRWAY ON ALL FLOOR LEVELERS WHERE <br />COMBUSTIBLE MATERIALS HAVE BEEN ACCUMULATED. <br />IN EVERY STORAGE AND CONSTRUCTION SHED, <br />WHERE SPECIAL HAZARDS EXIST, SUCH AS PAINT OR <br />FLAMMABLE LIQUID STORAGE AREAS. <br />1505. MEANS OF EGRESS SHALL BE MAINTAINED AT ALL TIMES. <br />1509 APPROVED WATER SUPPLY. AN APPROVED WATER SUPPLY FOR <br />FIRE PROTECTION SHALL BE MADE AVAILABLE AS SOON AS <br />COMBUSTIBLE MATERIAL ARRIVES ON SITE <br />NO CHANGE OF OCCUPANCY IS BEING PROPOSED <br />EXISTING PROJECT <br />INFORMATION <br />7 Buildings <br />6 Residential <br />1 Office/ Manager <br />Parking Stalls- <br />119 <br />Standard <br />11 <br />Accessible <br />43 <br />Compact <br />173 <br />Total <br />Floor Areas: <br />Bldg, 1 <br />18 Units, 15,942 s.f. <br />Bldg. 2 <br />18 Units, 15,942 s.f. <br />Bldg. 3 <br />18 Units, 15,942 s.f. <br />Bldg. 4 <br />18 Units, 20,538 s.f. <br />Bldg. 5 <br />18 Units, 20,538 s.f. <br />Bldg. 6 <br />9 Units, 7,269 s.f. <br />Office <br />1 Unit, 4,053 s.f. <br />10 <br />100 Units, 100,224 s.f. <br />PR <br />DEFERRED SUBMITTALS: <br />PROJECT DESCRIPTION <br />RECONSTRUCTION AND REPLACEMENT OF <br />EXISTING WOOD STAIRS (REPLACEMENT IN <br />KIND) <br />1. PREFABRICATED GUARDRAIL SYSTEM AND RAILINGS <br />DEFERRED APPROVAL ITEMS <br />SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR <br />ENGINEER OF RECORD WHO SHALL REVIEW THEM AND INDICATE THAT THE DEFERRED SUBMITTAL DOCUMENTS <br />HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN <br />OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND <br />SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE.BtftDtNGn0FRCtAL. DEFERRED SUBMITTALS SHALL BE <br />STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS THE PROJECT. <br />L eo <br />PROPERT <br />\ <br />LINI <br />PROPERTY <br />DESCRIPTION(S): <br />River's Landing Apartments <br />PROPERTY ADDRESS: 3015 9th Street, Everett, WA. 98201 <br />OWNER: <br />Williams Investments <br />OWNER ADDRESS: <br />OWNER PHONE: <br />(425) 355 0353 <br />PARCEL SIZE: <br />2.76 Acres <br />ZONING AREA: <br />MR (Multiple & Residential) <br />USE: <br />Residential Multi -Family. <br />PR <br />SPECIAL <br />INSPECTIONS: <br />PROVIDE SPECIAL <br />INSPECTION OF PILINGS AS <br />REQUIRED BY IBC <br />SECTION 1705.7 <br />Owner: G11 WILLIAMS INVESTMENTS LLC <br />Tenant: RIVER'S LANDING APTS-BLDG 7 <br />(OFFICE/MGR) <br />App. Date: 11/10/2021 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: REPAIR & REPL EXTERIOR STAIRS-BLDG 7 <br />(OFFICE/MGR) <br />Reviewed B Date: <br />Office Set lob Site Set Fire/Planning Set <br />STATEMENT OF SPECIAL INSPECTIONS <br />SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A <br />WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF <br />WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. <br />STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. <br />SPECIAL INSPECTION <br />OPERATION <br />CONT <br />PERIODIC <br />REMARKS <br />SOILS <br />PIPE PILING INSTALLATION <br />X <br />PILING REFUSAL VERIFICATION <br />X <br />NOTE: <br />ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL <br />INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE <br />ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL <br />RESULTS. ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT <br />TO THE ATTENTION OF THE DESIGN TEAM. <br />CITY OF EVERETT <br />Permit Services <br />9552 REGISTERED <br />ARCHITECT <br />0000 <br />CHA.L AARON STEVENS <br />STATE OF WASHINGTON <br />Re -siding Project, <br />River's Landing <br />Building 7 <br />FOR <br />Williams <br />nvestments <br />AT <br />3015 9th Street, Everett, <br />WA. 98201 <br />Permit Set <br />This drawing is: <br />1. Copyright 2020 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />2021-023 <br />MARK DATE DESCRIPTION <br />PR 1 12/30/2021 1 Permit Correction <br />PRINCIPAL IN CHARGE:1 MS <br />PROJECT MANAGER: DH <br />PROJECT ARCHITECT: AO <br />JOB CAPTAIN: KF <br />COVER SHEET AND <br />9TH STREET <br />SITE PLAN - RAMP LOCATION B-7 AREA <br />1" = 50'-0" <br />■ <br />RAMP LOCATION <br />SERVING BUILDING <br />#7 AREA <br />RAMP LOCATION PLAN <br />������ � C F , y- - <br />„ � � � tip• � ` .� <br />0 25' 50' 100, DRAWING NUMBER: <br />IL <br />N <br />Scale: 1" = 50' M <br />/\ r1 <br />N <br />1 <br />PR N <br />00 <br />N <br />a <br />1■. <br />■L <br />