My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12906 19TH AVE SE 2020 Plans 2023-02-24
>
Address Records
>
19TH AVE SE
>
12906
>
Plans
>
12906 19TH AVE SE 2020 Plans 2023-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2023 8:32:55 AM
Creation date
2/23/2023 4:09:06 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12906
Permit
B2004-018
Year
2020
Notes
WITHIN THE WALLS REMODEL OF EXTG STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REFRIGERATION CONTROL EQUIPMENT <br />DESCRIPTION <br />RESPONSIBILITY <br />COMMENTS <br />REM <br />HVAC-M <br />RIC <br />KROGER <br />EC <br />HVAC-C <br />EMS-C <br />COMMUNICATION/POWER CABLING <br />NETWORK WIRING BETWEEN PROTOCOURACK CONTROLLERS AND IDF CABINETS <br />F/I <br />1* <br />`CONDUIT TO ACCESSIBLE CEILING SPACE <br />NETWORK WIRING BETWEEN ALARM LOGGER AND OF CABINETS <br />F/I <br />I* <br />`CONDUIT TO ACCESSIBLE CEILING SPACE <br />NETWORK WIRING BETWEEN PROTOCOL UNITS/RACKS VSD PANELS, AND DEFROST <br />PANELS <br />F/I <br />NETWORK WIRING TO CONDENSERS COMMUNICATION BOARDS <br />I* <br />F/I <br />*ROOF PENETRATION CONDUIT BY EC. <br />NETWORK WIRING BETWEEN HOCA OR HICA UNIT CONTROL BOARD AND CONTROLLE <br />F/I <br />WIRING TO REFRIGERATION LIQUID LINE SOLENOID VALVES <br />F/I* <br />F/I <br />'IF SUPPLIED AS 120 LINE VOLTAGE <br />WIRING TO REFRIGERATION SUCTION STOP SOLENOID VALVES <br />F/I* <br />F/I <br />'IF SUPPLIED AS 120 LINE VOLTAGE <br />WIRING TO DEFROST TERMINATIONS <br />F/I <br />WIRING TO HOT WATER RECLAIM VALVE AND CONTROLS <br />F/I* <br />F/I <br />*IF SUPPLIED AS 120 LINE VOLTAGE <br />WIRING TO COOLER/FREEZER DOOR SWITCHES <br />F/I <br />LINE VOLTAGE POWER TO VSD CONTROL PANELS, LINE REACTORS AND DRIVES <br />F/I <br />WIRING TO DEFROST PANEL LOW VOLTAGE CONTROL TERMINATIONS <br />F/I <br />WIRING TO DEFROST PANEL LINE VOLTAGE CONTROL TERMINATIONS <br />F/I <br />PER NEC <br />LINE VOLTAGE POWER TO EMS EQUIPMENT <br />F/1* <br />F/1 <br />120 LINE VOLTAGE SIDE OF TRANSFORMER <br />WIRING TO ALARM BOX(S) <br />F/I* <br />F/I <br />" 120 LINE VOLTAGE SIDE OF TRANSFORMER <br />EMS CONDUIT(S) <br />F/I <br />PROVIDE PULL STRING <br />REFRIGERATION EQUIPMENT <br />REFRIGERATION CONTROL PANEL (RX CONTROLLER - CPC OR DAN FOSS) <br />F/I* <br />F <br />I <br />*NEW PROTOCOL/RACK ONLY. <br />1/0 BOARDS/MODULES & TRANSFORMERS IN RACKS <br />F/I" <br />F <br />I <br />'NEW PROTOCOURACK ONLY. <br />CONTROL FUSES, FUSE BLOCKS (LOW VOLTAGE) <br />F/1* <br />F/I <br />*NEW PROTOCOURACK ONLY. <br />CONTROL FUSES, FUSE BLOCKS (LINE VOLTAGE) <br />F/I* <br />F/I <br />*NEW PROTOCOURACK ONLY. <br />CONTROL BREAKERS (LOW VOLTAGE) <br />F/1* <br />F/I <br />'NEW PROTOCOURACK ONLY. <br />CONTROL BREAKERS (LINE VOLTAGE) <br />F/I* <br />F/I <br />ANEW PROTOCOURACK ONLY. <br />CONDENSER BOARDS W/ENCLOSURE &TRANSFORMERS <br />F/I* <br />'NEW PROTOCOURACK ONLY. <br />VSD BYPASS PANEL, LINE REACTORS, DRIVES <br />F <br />I <br />11` <br />'LOW VOLTAGE CONTROLS <br />NEW IRI US II PANEL / MRLDS <br />F <br />1* <br />1 <br />'120 LINE VOLTAGE AND CONDUIT <br />ANTI -SWEAT CONTROLLER (CPC - PMAC 11 OR DAN FOSS - NO SWEAT) <br />F <br />I* <br />I <br />'120 LINE VOLTAGE, CONDUIT AND MOUNT PANEL <br />NEW DEFROST PANEL WITH EXISTING PROTOCOL OR EXISTING RACK <br />F <br />1* <br />*1201208 LINE VOLTAGE, CONDUIT AND MOUNT PANEL <br />NEW DEFROST PANEL WITH NEW PROTOCOL OR WITH NEW RACK <br />F <br />1* <br />'1201208 LINE VOLTAGE, CONDUIT AND MOUNT PANEL <br />EXISTING DEFROST PANEL MODIFICATIONS (PER PLANS) (LOW VOLTAGE) <br />F <br />I <br />CONTROL BOARDS/MODULES, POINTS <br />EXISTING DEFROST PANEL MODIFICATIONS (PER PLANS)(LINE VOLTAGE) <br />711 <br />'120/208 LINE VOLTAGE, BREAKERS & CONTACTORS <br />EXISTING REFERG. RACK MODIFICATION FOR NEW ELECTRICAL COMPONENTS <br />F11* <br />* BREAKERS, SWITCHES, INDICATOR LIGHTS TO MATCH <br />EXISTING RACK COMPONENTS <br />SUCTION STOP SOLENOID VALVES <br />F <br />1 <br />1* <br />I'* <br />*120/208 LINE VOLTAGE **LOW VOLTAGE <br />REFRIGERATION LIQUID LINE SOLENOID VALVES <br />F <br />I <br />I* <br />1** <br />*120/208 LINE VOLTAGE **LOW VOLTAGE <br />SPORT EPR VALVES <br />F/1* <br />I <br />F <br />I** <br />*NEW RACKSlPROTOCOL ONLY -LOW VOLTAGE <br />CPC RX-400 ANNUNCIATOR/DAN FOSS ALARM LOGGER <br />F <br />1* <br />i <br />-120 LINE VOLTAGE AND MOUNT PANEL <br />REFRIGERATION SENSORS <br />RACK / REMOTE/ PROTOCOL UNIT SENSORS AND TRANSDUCERS <br />F/I* <br />F/I <br />*NEW PROTOCOL ONLY. <br />WALK-IN COOLER / FREEZER ANALOG TEMPERATURE SENSORS <br />I <br />F <br />1* <br />EMSC TO COORDINATE WITH RIC FOR SENSOR INSTALL <br />&SEAL PENETRATIONS <br />REFRIGERATED MERCHANDISER ANALOG TEMPERATURE SENSOR <br />F/I* <br />I** <br />F <br />*NEW CASES ONLY, **RIC SEAL PENETRATIONS <br />WALK-IN DEFROST THERMOSTATS/KLIXON LOW TEMP <br />F/I <br />HOT WATER HEAT RECLAIM TEMPERATURE PROBE/ SENSOR <br />F <br />I <br />PROBE/WELL INSTALLED BY PLUMBING CONTRACTOR <br />WALK-IN DOOR SWITCHES <br />F/I <br />CONDENSING UNIT SENSORS <br />F <br />I <br />BUILDING CONTROL COMMUNICATION <br />BUILDING CONTROL EQUIPMENT <br />OWNER CABLING <br />NETWORK WIRING BETWEEN ENVIROMENT BX CONTROLLER AND IDF CABINET <br />F/I <br />NETWORK COMMUNICATION WIRING BETWEEN COMMUNICATION BOARDS <br />F/I <br />WIRING TO HVAC FIELD SENSORS <br />F/I <br />WIRING TO OVERRIDE BUTTONS <br />F/I <br />WIRING TO LIGHTTNG CONTACTOR CABINETS <br />F/1' <br />F/I <br />-120 & 277 LINE VOLTAGE AND CONDUIT <br />WIRING TO UNIT HEATERS <br />F/I <br />MAKE ALL FINAL CONNECTIONS <br />WIRING TO CONTROL TRANSFORMERS <br />F/P <br />F/I <br />'120 LINE VOLTAGE AND CONDUIT <br />WIRING TO DUCT SMOKE DETECTOR (HVAC UNIT SHUTDOWN) <br />F/1 <br />WIRING TO ENVIROMENTAL BX CONTROLLER (CPC OR DAN FOSS) <br />F/1' <br />F/I <br />*120 LINE VOLTAGE AND CONDUIT <br />WIRING TO REFRIGERATION CONTROLLER (CPC OR DAN FOSS) <br />F11* <br />F/I <br />*120 LINE VOLTAGE AND CONDUIT <br />WIRING TO ANTI/NO-SWEAT PANEL (CPC OR DAN FO55) <br />F/1* <br />F/I <br />*120 LINE VOLTAGE AND CONDUIT <br />EMS CONDUIT <br />F/I <br />PROVIDE PULL STRING <br />BUILDING CONTROL EQUIPMENT <br />ENVIROMENTAL BX CONTROLLER. PANEL (CPC OR DAN FOSS) <br />F <br />I <br />OVERRIDE BUTTONS <br />F/I <br />CPC AIIRO BOARDSIDAN FOSS AURO MODULES FOR ENVIROMENTAL BX CONTROLLER <br />F <br />I <br />CPC MULTIFLEX 168 AND 8RO BOARDS/DAN FOSS AURO MODULES FOR HVAC UNITS. <br />'F/I <br />F <br />I <br />*NEW UNITS ONLY <br />CPC MULTIFLEX 88AO/DAN FOSS AURO MODULES FOR SMALL HVAC UNITS <br />*F/1 <br />F <br />I <br />*NEW UNITS ONLY <br />CONTROL TRANSFORMERS FOR MONITORING <br />I <br />F <br />LIGHTING CONTACTOR CABINETS <br />NEW LIGHTING CONTACTOR CABINET INCLUDING CONTACTORS (PER EM7.x <br />DOCUMENTS) <br />I <br />F* <br />*CONTACTORS ASSEMBLED IN ENCOSURES PER EM7.X <br />REWORKED LIGHTING CONTACTOR CABINET (PER EM7.x DOCUMENTS) <br />_ LINE VOLTAGE 1201277 VOLTS <br />F/I <br />I <br />F <br />_CONTACTORS <br />LOW VOLTAGE (INCLUDING Terminal blocks, Relays, Fuses) <br />F11 <br />CONTROLLER PROGRAMMING <br />REFRIGERATION CONTROLLER PROGRAMMING <br />F/I <br />BUILDING CONTROLLER PROGRAMMING <br />F/I <br />HVAC SENSORS <br />SALES AREA TEMPERATURE SENSORS <br />F <br />I <br />DUCT SMOKE DETECTOR <br />F/I <br />COORDINATE TYPE WITH FIRE ALARM/WIRED BY EMS-C <br />RELATIVE HUMIDITY SENSORS <br />F <br />I <br />AIR SWITCH SENSOR OR FAN PROOFING FOR EXISTING UNITS <br />F/1 <br />FAN PROOFING COMPATIBLE WITH CPC/DAN FOSS <br />CO2 SENSORS <br />F <br />I <br />AMBIENT SENSORS OR OUTDOOR WEATHERSTATION <br />F/I <br />LIGHTING SENSORS <br />ROOF LIGHT LEVEL SENSOR <br />F <br />I <br />ON ROOF FACING NORTH. <br />SKYLIGHT LIGHT LEVEL SENSOR (NOT USED) <br />F <br />I <br />IN THE SPACE UNDER SKYLIGHT DOME <br />REFRIGERATION MOTION SENSOR (WATT STOPPER) <br />MOTION SENSOR <br />F <br />I <br />SEE DETAIL EISD1 <br />POWER PACK <br />F <br />I <br />SEE DETAIL EISDl <br />CONNECTION CABLE FOR MOTION SENSOR <br />F <br />1 <br />SEE DETAIL EISD1 <br />GENERAL CONTROL EQUIPMENT <br />WIRING EMERGENCY GENERATOR REMOTE ANNUNCIATOR <br />F <br />I <br />LOCATE AT CS DESK. FOR NEW GENERATOR <br />IEGEND <br />F - FURNISH <br />RIC - <br />REFRIGERATION INSTALLATION CONTRACTOR <br />INSTALL <br />EC - <br />ELECTRICAL CONTRACTOR <br />FURNISH AND INSTALL <br />� HVAC-M <br />- HVAC EQUIPMENT MANUFACTURER (OEM) <br />_ <br />REM - REFRIGERATION EQUIPMENT MANUFACTURER (OEM) <br />HVAC-C <br />- HVAC CONTRACTOR <br />KROGER -OWNER <br />EMS <br />-EMS CONTRACTOR <br />11 CONTRACTOR RESPONSIBILTY MATRIX DETAIL <br />3� GENERAL SYMBOLS <br />SYMBOL <br />DESCRIPTION <br />DT <br />DEFROST TERMINATION THERMOSTAT <br />TS (� )TS <br />ANAIOG TEMPERATURE SENSOR <br />S� <br />ANALOG TEMPERATURE SENSOR (HVAC) <br />RH <br />ANALOG RELATIVE HUMIDITY SENSOR <br />LLS <br />LIGHT LEVEL SENSOR <br />CA) <br />AMBIENT TEMPERATURE SENSOR / SHIELD <br />DS <br />DOOR SWITCH <br />PM <br />PHASE MONITOR <br />SD O-D <br />SMOKE DETECTOR <br />OCLEAN <br />POWER FIELD INSTAI LED BY EC <br />KEY NOTE SYMBOL <br />DA <br />LOCAL DOOR ALARM <br />TS <br />IMMERSABIE TEMPERATURE SENSOR NUMBER <br />4S <br />(4) INTERNAL RTU MIXED AIR TEMPERATURE <br />SENSORS <br />2S' <br />(2) INTERNAL RTU MIXED ,AIR TEMPERATURE <br />SENSORS <br />AIR FLOW/ SAIL PROOFING SWITCH <br />[RAI F <br />REFRIGERTION LEAK ALARM <br />EPR <br />EVAPORATOR PRESSURE REGULATOR <br />AC <br />U <br />HVAC UNIT DESIGNATION (AC, RTF, UH, EF) <br />(E) (N) (R) <br />EXISTING / NEW / RELOCATED <br />PUSHBUTTON <br />SS LS J <br />SUCTION STOP SOLENOID OR LIQUID SOLEN01� <br />RS <br />REFRIGERANT LEAK SENSOR, TUBING <br />IT <br />HORN STROBE <br />CO2 <br />CO2 SENSOR <br />o <br />STUB UP LOCATION FOR CONDUIT. <br />WHEN CASES ARE FED <br />FROM LOOP <br />PIPING, <br />SUCTION STOP SOI ENOIDS WILL <br />BE ON REFRIGERATION <br />CIRCUITS ON <br />SALES <br />FLOOR. <br />FRED MEYER <br />EMS Pnet List <br />Mill Greek 468 <br />DIRECT BUY ITEW Emerson Controls Technique Items <br />Usage <br />ITEM NUMBER <br />DESCRIPTION <br />QTY <br />EPR <br />1 <br />E2-RX400 controllers for each rack <br />2 <br />K-0008718 <br />replace existing failing network port <br />2 <br />E2-BX400 Controller for EMS panel <br />1 <br />K-0008729 <br />replacing failed network port <br />3 <br />MFLEX 168 BOARD <br />3 <br />K-0008836 <br />one for each rack <br />- <br />4 <br />Outdoor light level sensor <br />1 <br />K-0008820 <br />Outdoor light level <br />5 <br />INDOOR RELATIVE HUMIDITY SENSOR <br />1 <br />K-0008822 <br />FOR A/S <br />6 <br />Space sensor w slider <br />1 <br />1 K-0008721 <br />for PRX only <br />7 <br />Bacharach 16Ch HGAII MZ 5x,1000' <br />1 <br />K-0052368 <br />refrigerant leak detection devices <br />19255 SW Teton Ave. <br />Tualatin,0 <br />SCA�LL: NONE 2 EMS EPRO ITEMS DEED <br />SCALE; NONE <br />KEY MOTE <br />DESCRIPTION <br />V1,11RE TYPE <br />PLENUM <br /><1> <br />W.A.N. CONNECTIONBEIDEiN <br />#1533P 1124-8 CATEGORY-5 CABLE OR APPROVED EQUAL <br />// <br />\J <br />RS-485 NETWORK <br />BELDEN 1#88641 #22-2 SHEILDED CABLE OR APPROVED EQUAL <br />ANAI OG/DIGITAL TEMPERATURE SENSOR/IItiIPUT: <br />BELDEN 1/18-2 SHIEI-DED CABLE OR APPROVED EQUAL <br />11 <br />DEFROST TERMINATION SENSOR: <br />BELDEN #18-2 SHIELDED CABLE OR APPROVED EQUAL <br />�� <br />\� <br />RESTIVE HUMIDITY SENSOR: <br />BELDEN18-3 SIIIFIDED CABLE OR APPROVED EQUAL <br />4 <br />LIGHT LEVEL SE1NSOR/PRX TEMPERATURE SENSOR <br />BELDEN V18-4 SHIELDED CABLE OR APPROVED EQUAL <br />V`/ <br />OUTDOOR TEMPERATURE SENSOR /DROP LEG <br />SENSOR- <br />BELDEN �18-2 SHIELDED CABLE OR APPROVED EQUAL <br />HORN STRB REFER LEAK ALARM/LOCAL DR ALARM <br />#14 TWISTED PAIR (PLENUM RATED) <br />LIGHTING CONTROL CABINET <br />MULTI -CONDUCTOR CABLE TO COVER ALL LIGHTING CONTACTOR CONTROL <br />TO EMS 8RO BOARD. <br />1 <br />REFRIGERATION SOIENOID VALVE <br />14 TWISTED PAIR (PLENUM RATED) <br /><j <br />LIGHTING CONTROL BUSS CONTACTOR <br />#14 TWISTED PAIR (PLENUM RATED) <br />/> <br />HVAC STAGING CONTROL <br />#22-8 OR LOW VOLTAGE MULTI CONDUCTOR CABLE <br />1 3> <br />UNIT HEATER CONTROL <br />#18/2 FOR CONTROL AND#18-2 FOR TEMPERATURE SENSOR OR EQUAL. <br /><�4 <br />LINE VOLTAGE IN CONDUIT <br />PER NEC & MANUFACTURE'S GUIDUNES <br />�� <br />TRANSDUCER <br />BELDEN #887/70 "'18-3 SHIELDED CABLE OR APPROVED EQUAL <br />EXISTING CONDUCTOR TO REMIAN. TYPE AS INDICATED. <br />` <br />< E> <br />} <br />I MANUFACTURE PROVIDED AND INSTALLED CONDUCTOR <br />ELECTRICAL CONTRACTOR INSTALLED CONDUCTOR AND CONDUIT. <br />I <br />i <br />SCALE: NONE 1 4] ENER(j'Y MARAGEPIENT WHNG SCHEDULE DETAii <br />REFRIGERATION <br />RACK A <br />RT UNIT(S) <br />RX-400 <br />CONTROLLER <br />®000� n <br />®!0® ®® 0/ <br />N®EN®®®®©® NNN <br />®P7mT'TF3®BED EJQ 1;1GS <br />—HEM =a <br />Ca <br />A B <br />�E <br />(E) CPC <br />16AI BOARD <br />OE --f <br />(E) CPC <br />I16AI BOARD <br />E <br />(E) CPC <br />8RO BOARD <br />E <br />(N) CPC <br />r-1 168 BOARD <br />(N) CPC <br />SRO BOARD <br />(N) CPC <br />8RO BOARD <br />LEAK DETECTION <br />PANEL <br />(E) CPC <br />10 BOARD <br />CONDENSER A <br />TO KROGER SUPPLIED ETHERNET SWITCH IN THE T FLFPHONE/FCR ROOM OR OF CABINET <br />PER LOCAL 1/S DEPARTMENT SPECIFICATIONS NETWORK CONFIGURATION PROVIDED BY <br />LOCAL I/S DEPARTMENT. <br />(E) CPC <br />BOARD <br />(E) CPC <br />BOARD <br />REFRIGERATION <br />RACK B <br />RX-400 <br />CONTROLLER <br />A B C <br />T:- <br />(E) CPC <br />16AI BOARD <br />�E L — <br />(E) CPC <br />16AI BOARD <br />2,>- <br />(E) CPC <br />16Al BOARD <br />(E) CPC <br />SRO BOARD <br />(E) CPC <br />8R0 BOARD <br />(R) CPC <br />SRO BOARD <br />2 <br />(N) CPC <br />168 BOARD <br />REFRIGERATION <br />RACK C <br />(E) CPC <br /><� 16A1 BOARD <br />E <br />�(E) CPC <br />16AI BOARD <br />2 <br />(E) CPC <br />16AI BOARD <br />2� <br />(E) CPC <br />8RO BOARD <br />2 �j <br />(E) CPC <br />8RO BOARD <br />(R) CPC <br />SRO BOARD <br />(N) CPC <br />168 BOARD <br />BUILDING <br />CONTROLLER <br />BX-400 <br />CONTROLLER <br />0 <br />2 2 <br />(E) CPC (E) CPC <br />10 BOARD 10 BOARD <br />CONDENSER B CONDFNSER C <br />TO KROGER SUPPLIED ETHERNET SWITCH IN THE TELEPHONE/ECR ROOM OR IDF CABINET <br />PER LOCAL I/S DEPARTMENT SPECIFICATIONS NETWORK CONFIGURATION PROVIDED BY <br />LOCAL I/S DEPARTMENT. <br />GENERAL MOTES: <br />1 . CONTRACTOR 1-0 INSTALL AND TERMINATE RS485 NETWORK. RS485 <br />NETWORK SHAI I BE DAISY -CHAINED AND TERMINATED AT BOTH ENDS OF <br />THE NET1!VORK. SEE MANUFACTURE INFORMATION ON BOARD TERMINATIONS. <br />2. ALL BOARDS ARE LISTED HERE ARE MIGHT NOT BF IN THE SAME ORDER AS <br />SHOWN OR SAME NUMBER OF 1/0 BOARDS. SEE EM5 FOR SENSORS <br />TERMINATION AND COORDINATE WFFH OTHER TRADERS FOR COMPLETED <br />CONTROLLED SYSTEM. <br />3. CONTRACTOR TO VERIFY EXISTING NETWORK LOOP AND UPDATE AS BUILDS. <br />4. UNITS SHOWN ARE NOT IN ORDER OF DAISY -CHAIN RUN. THIS REFLECT THE <br />IDEA OF CABI E RUN. <br />KEY MOTES: <br />GEXISTING NETWORK PATH UNKNOWN. SEE GENERAL NOTE 2. <br />�2 COORDINATE WITH MANUFACTURER INFORMATION PROVIDED WITH EQUIPMENT FOR <br />TERMINATION. <br />/0 BEARDS RS485 NETWORK MAKE CONNECTION AS NEEDED. <br />EXTEND COMMUNICATION LOOP FROM LAST DEVICE IN REFRIGERATION LOOP. <br />J PROVIDE OUTDOOR WEATHER PROOF 12x12x6 ENCLOSURE RELOCATE THE RTU <br />�5 BOARDS FROM THE FAN COMPARTMENT TO THE ENCLOSURE OR INSTALL NEW <br />BOARDS IN NEW ENCLOSURE WHERE SHOWN NEW &MAKE ALL CONNECTIONS. <br />EXTEND ALL SENSOR WIRES TO VERIFY OPERATION, IF EXISTING RTU BOARD IS <br />NOT USABLE OR DAMAGED, CONTACT KPM FOR POSSIBLE REPLACEMENT. <br />6 FILED INSTALLED BOARD. MAKE FINAL COMMUNICATION CONNECTIONS. <br />E2 REFRIGERATION (RX) CONTROLLER <br />INSTALL 1\IEW F2 CONTROLLER IN EXISTING PANEL WITH PROVIDED MOUNTING <br />HARDWARE. FLAKE ALL FINAL CONNECTIONS TO CONTROLLER. <br />9) DISCONNECT NETWORK AND PROVIDE NEW AS INDICATED. <br />I <br />i <br />SCALE; NONE EIETWORh WIRING LOOP DETAIL <br />LEGS PAID <br />A B <br />+v <br />(E) CPC <br />16AI BOARD <br />7— (F) CPC <br />16A1 BOARD <br />(E) CPC <br />SRO BOARD <br />(E) CPC <br />8RO BOARD <br />LIGHT/DASHED <br />= EXISTING tUIRING <br />- - LIGHT/SOLID = <br />EXISTING EQUIPMENT <br />— DARK/DASHED <br />= NEW WIRING <br />----- DARK/SOLID = <br />NEW EQUIPMENT <br />so <br />A ME <br />Architecture Interiors <br />Planning Engineering <br />Portland, OR <br />503.224.9560 <br />Vancouver, WA <br />360.695.7879 <br />Seattle, WA <br />206.749.9993 <br />www.mcknze.com <br />DESIGN DRIVEN I CLIENT FOCUSED <br />Client <br />STORES,FRED MEYER <br />INC. <br />300 SE 22ND ROAD, <br />MACKENZIE <br />2019 ALL RIGHTS RESERVED <br />THESE DRAWINGS ARE THE PROPERTY OF <br />MACKENZIE AND ARE NOT TO BE USED <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />Revision Schedule <br />Revision Lie Date <br />DRAWN BY: GF <br />CHECKED BY: WC <br />SHEET <br />EM1 <br />Permit Set:, 02/17/2020L--- <br />
The URL can be used to link to this page
Your browser does not support the video tag.