My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12906 19TH AVE SE 2020 Plans 2023-02-24
>
Address Records
>
19TH AVE SE
>
12906
>
Plans
>
12906 19TH AVE SE 2020 Plans 2023-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2023 8:32:55 AM
Creation date
2/23/2023 4:09:06 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12906
Permit
B2004-018
Year
2020
Notes
WITHIN THE WALLS REMODEL OF EXTG STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KEY NOTES. <br />1. NEW UNIT WIRED WITH FACTORY INSTALLED CPC CONTROL BOARD. EMS CONTRACTOR TO Architecture ® Interiors <br />COORDINATE WORK WITH OTHER TRADES AND MAKE ALL CONTROL CONNECTIONS AS <br />REQUIRED. EMS-C TO COORDINATE ALL ROOFTOP PENETRATIONS WITH EC. Planning I- Engineering <br />2. NEW THERMOSTAT/SENSOR(S) FOR UNIT, INSTALLED BY CONTROLS CONTRACTOR. <br />3. (E) CPC CONTROL BOARD TO BE REPLACED AS REQUIRED. NEW BOARD SUPPLIED BY KROGER <br />PROJECT MANAGER. RELOCATED THE BOARD FROM FAN COMPARTMENT TO THE ENCLOSURE <br />4. EXITING CPC CONTROL BOARD TO REMAIN, PROVIDE AND INSTALL WEATHER PROOF Portland, O <br />ENCLOSURE, RELOCATED THE BOARD FROM FAN COMPARTMENT TO THE ENCLOSURE 503.224.9560 <br />Vancouver, WA <br />5. LIGHTING CONTACTOR ENCLOSURE, INSTALL AND MODIFY CONTACTORS AS SHOWN ON THE 360.695.7879 <br />PLANS. SEE EM7 PLANS FOR DETAILS TERMINATION OF ALL LOW VOLTAGE WIRING <br />COORDINATE WITH ELECTRICAL CONTACTOR. Seattle, WA <br />206.749.9993 <br />6. NEW TEMPERATURE AND HUMIDITY SENSORS, INSTALLED BY CONTROLS CONTRACTOR. www.mcknze.com <br />r' r 7. NEW RETURN SMOKE <br />DUC E GENERALT TECTOOR PROVID <br />6. ED, WIRED AND TESTED BY CONTROLS CONTRACTOR <br />DESIGN DRIVEN i CLIENT FOCUSED <br />_. - <br />- -- -- -- -- - - - - --- 8 SMOKED CT DETECTOR TO REMAIN, T OPERATION CONNECTION, E <br />- --- I -. --_ GENE Client <br />_ �� -� - �- <br />EXITING U E TES !T OPE A NAND <br />GENERAL NOTE 6. <br />\I �� 9. INPUT/OUTPUT TO BX CONTROLLER. <br />I <br />i <br />10. EXISTING CONTACTOR ENCLOSURE MAKE ALL MODIFICATIONS AS SHOWN ON EM7 PLANS FOR <br />FRED MEYER <br />- 1 - SCHEDULES. <br />11. EXHAUST FAN TO BE INTERLOCKED WITH AC UNIT(S). SEE M6.1.1 FOR SCHEDULE. PROVIDE CT STORES, INC. <br />FOR FAN STATUS TO CONTROL SYSTEM AND PROGRAM TO INTERLOCK AC UNITS AS SHOWN 3800 SE 22 D ROAD, <br />- - ON M6.1.1 PORTLAND, OR 97202 <br />12. PUSH BUTTON FOR LIGHTING OVERRIDE, PULL SEPARATE WIRES FOR PUSH BUTTON TO AC , <br />�. , ; � <br />UNIT BOARD OR EMS PANEL.' �- <br />13. BUILDING CONTROLLER. MODIFY EXISTING PANEL AND ADD ALL NECESSARY 1/0 BOARDS AS <br />SHOWN ON THE PRINTS PER DETAIL EM8. <br />r-- ---- - -- - ---- - - --- ---- --=--- - - ---- ---- -- ---- ---� - - ' 14. 12"x12°'x6" JUNCTION BOX IN BETWEEN GUTTER AND BX PANEL;PROVIDE APPROPRIATELY <br />> s, 's, (,1 � SIZED CHASE NIPPLES TO BX PANEL AND GUTTER (2). EMS-C TO INSTALL NEW TERMINAL <br />6 �_' l'� �) �_.l `" �.-'i �.� �`i <br />v STRIP IN JUNCTION BOX, EMS-C TO LAND ALL LIGHTING LOW VOLTAGE WIRES WIRES AS <br />NECESSARY AND DEMO ALL UNUSED. <br />15. REMOTE BUILDING CONTROL PANEL. PROVIDE NEW ENCLOSURE TO HOUSE TWO BOARDS. <br />RELOCATE EXISTING RELAY BOARD INTO NEW PANEL WITH PROVIDED 88AO BOARD. EXTEND <br />ALL POWER AND NETWORK CONNECTIONS AS REQUIRED. <br />16. EXISTING TEMPERATURE SENSOR AND RELATIVE HUMIDITY SENSOR, REPLACE AS NEEDED Project <br />-- -- 17. EXISTING SENSOR REUSE/REPLACE AS NEEDED <br />MILL CREEK <br />l 18. HAM GLAZING EXHAUST FAN, INSTALL CT TO MONITOR STATUS OF FAN AND INTERLOCK UNIT <br />THAT IS LISTED ON M6.1.1 FOR THIS FAN. PROGRAM THE CONTROLLER TO BRING AC UNIT ON <br />-__ _ -- --- - WHEN FAN IS ON12906 Bothell Everett Hwy <br />--- - - - <br />------ - <br />i; <br />Everett, WA 98208 <br />19. INSTALL NEW COM CABLE BETWEEN UNITS TO MAINTAIN DAISY CHAIN FORMAT. <br />20. SKYLIGHT LIGHT LEVEL SENSOR. SEE DETAILS ON EM8. ROUTE TO BX PANEL. <br />f <br />= 21 EXISTING i CONTROL OL CONDUCTOR TO REMAIN, <br />i I <br />N <br />I I - <br />_ l' _ -..__ - Lam--- - -- <br />I 22. CO2 SENSOR, PULL WIRES TO NEAREST UNIT AS REQUIRED, INSTALL AND VERIFY OPERATION. <br />_ JL j 23. AMBIENT TEMPERATURE SENSORS, PULL WIRES TO EMS PANEL AS REQUIRED AND VERIFY <br />- �I I� <br />_4 -, <br />© �I OPERATION. <br />24. OUTDOOR LIGHT LEVEL SENSOR, PULL WIRES TO EMS PANEL AND VERIFY OPERATION. <br />=- <br />- 25. BUILDING PRESSURE TRANSDUCER,PROVIDE AND INSTALL TRANSDUCER THAT MEASURES <br />--- -- - ---_ li BUILDING PRESSURE IN INW, CONNECT TO BUILDING CONTROLLER INPUT POINT. USE DEVICE <br />THAT IS COMPATIBLE WITH CONTROL SYSTEM. 0-5VDC OUTPUT WITH +0.1 TO -0,1 INW SCALE. <br />26. EXISTING PROGRAMMABLE THERMOSTAT TO REMAIN. <br />27. MASTER LIGHTING OVERRIDE PUSH BUTTON, USE THE BUILT IN PUSH BUTTON WITH ZONE <br />- - SENSOR AND PULL SEPARATE WIRE FOR THE BUTTON TO EMS PANEL. <br />I'I <br />a 28. CONTROL EACH UNIT HEATER SEPARATE, PULL TEMPERATURE SENSOR WIRE AND CONTROL <br />WIRE TO EMS PANEL INPUT/OUPUT BOARD. INSTALL 24V RELAY AT UNIT HEATER AND <br />CONTROL FROM EMS PANEL. <br />29. NEW TEMPERATURE, HUMIDITY AND CO2 SENSOR, INSTALL BY CONTROLS CONTRACTOR, <br />WIRED TO CPC BOARD AT RESPECTIVE UNIT <br />WAIN <br />r �\ - - 30. PUSH BUTTON OVERRIDE PANELS, SUPPLIED & INSTALLED BY CONTROLS CONTRACTOR, WIRE <br />1i TO BUILDING CONTROL PANEL , INC. <br />I 31. 15 CONDUCTOR CABLE(18AWG CONDUCTOR) FROM EACH ELECTRICAL ROOM TO EMS PANEL 19255 SW TETON AVE. <br />TUA OFF 503.691.90027062 <br />\ I <br />FAX 501691.0313 <br />L11 <br />-- - - <br />IGENERAL NOTES. <br />1. MAINTAIN ALL SENSORS AND COMM LOOPS <br />1. COORDINATE ALL ROOF PENETRATIONS WITH EC. ALL ROOF TOP PENETRATIONS TO BE BY <br />1 ELECTRICAL CONTRACTOR. <br />g LIGHT <br />REPLACE EXIS <br />2. CONTRACTOR TO PROVIDE CONDUCTORS AND INSTALL ANY NEW HVAC SENSORS TO CPC BOARDS <br />III AS INDICATED. <br />4ISENSOR WITH OWNER PROVIDED SENSOR <br />it i <br />3. CONTRACTOR TO COORDINATE HVAC INTERLOCK MODIFICATIONS WITH MECHANICAL PLANS AND <br />..MECHANICAL CONTRACTOR. <br />REPLACE SPACE SENSOR IN PRX WITH NEW <br />I'3.4. SEE SHEET EM8 FOR ALL NEW OR REPLACED TEMPERATURE SENSORS. <br />5. CONTRACTOR TO COORDINATE WORK WITH RELATED TRADES. MACKENZIE <br />='- - FOWNER SUPPLIED SENSOR W/ 2019 ALL RIGHTS RESERVED <br />6. DUCT SMOKE DETECTORS WILL BE MONITORED BY THE CONTROLS SYSTEM VIA INPUT BOARD OR THESE DRAWINGS ARE THE PROPERTY OF <br />RTU/RCB INPUT POINT. UNIT SHALL TURN OFF WHEN DETECTOR IS TRIPPED. SEE DETAILS EM8 MACKENZIE AND ARE NOT TO 8E USED <br />III I j <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />I II 7. EMS-C TO ACQUIRE (E)CPC BOARDS FROM DEMO'D RTU'S AND RETURN TO OWNER IN ANTISTATIC <br />MATERIAL. - <br />1 3 <br />8. EMS-C TO DISCONNECT AND REMOVE ALL CONTROL CONDUCTORS ASSOCIATED WITH DEMOTED Revision <br />Schedule <br />HVAC EQUIPMENT. SEE MECHANICAL SCHEDULES FOR A LIST OF REMOVED UNITS. Revision Delta issue Date <br />�I 9. EMS-C RESPONSIBLE FOR THE DISCONNECT AND REMOVAL OF LOW VOLTAGE ITEMS INDICATED AS <br />I <br />DEMOTED OR TO BE BE REMOVED. <br />10. EMS-C RESPONSIBLE TO PROVIDE LABEL ON EACH TEMPERATURE SENSOR INDICATING THE AC UNIT <br />IT SERVES. <br />11. ALL ZONE SENSORS ARE OWNER PROVIDED AND HAVE BUILT IN PUSH BUTTON, USE BUTTON <br />WHERE INDICATED ON THE DRAWINGS. <br />li <br />12. MAINTAIN COM LOOP TO ALL AC UNITS AND E2 CONTROLLER. <br />13 SAVE ALL THERMOSTATS AND PROTECT FROM ANY DAMAGE <br />r f ] <br />�I <br />r <br />- 14. PUSH BUTTON OVERRIDE PANELS, PULL CONTROL WIRES/CABLES FROM EMS CONTROLLER PANEL. <br />SHEET TITLE: <br />CA <br />ENERGY <br />MANAGEMENT <br />I) <br />I I <br />Ll <br />I LIGHTING/HVAC <br />HVAC <br />PLANI <br />! I� <br />NOTE: <br />1. MAINTAIN COM LOOP TO ALL AC UNITS AND E2 <br />o <br />CONTROLLER. <br />2. SAVE ALL THERMOSTATS ARE SAVED FROM ANY <br />--- -- DAMAGE DRAWN BY: GF <br />3. PUSH BUTTON OVERRIDE PANED, PILL CONTROL <br />MIRES/CABLES FROM EMS CONTROLLER PANEL. CHECKED BY: WC <br />SHEET <br />EM6 <br />SCALD: N/A <br />I' LIGH I ING AND HVAC OVERALL Pi AN <br />JOB NO. 2190236.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.