GENERAL NOTES: <br />LIGHTING CONTACTOR ARE SIEMENS CLIV1XX203 1. XX IS <br />NUMBER OF POLES PER CONTACTOR. THE CONTACTORS ARE <br />MECHANICALLY HELD ELECTRICALLY CONTROLLED WITH 120V <br />COIL. PROVIDED BY CONTROLS CONTRACTOR. <br />2. NEW LIGHTING CONTACTOR ENCI OSURES ARE ASSEMBLED, UL <br />IISTED by CONTROLS CONTRACTOR AND DELIVERED TO THE <br />ELECTRICAL CONTRACTOR. <br />3. ELECTRICAL CONTRACTOR TO INSTALL OR REPLACE LIGHTING <br />CONTACTOR OR ENCLOSURES PER SCHEDULE. <br />4. THE LIGHTING CONTACTOR LAYOUT ABOVE IS A SAMPLE OF <br />HOW LIGHTING CONTACTORS SHOULD BE INSTALLED IN <br />CONTACTOR ENCLOSURES. LIGHTING CONTACTORS SHOULD <br />MATCH THIS LAYOUT AT ALL TIMES. <br />5. USE 24VAC RELAYS TO CONTROL EACH LIGHTING CONTACtOR <br />INDIVIDUALLY WITH OWN FUNCTION. WIRE CONTACTOR IN <br />SUCH THAT IF RELAY IS DE—FNERGIZED CONTACTOR IS <br />CLOSED. <br />6. NORMALLY CLOSED CONTACTORS ARE USED FOR ALL <br />CONTACTORS THAT CONTROLLING STANDBY GENERATOR FED <br />CIRCUITS AS NOTED ON CONTACTOR SCHEDULE <br />7- Al I 120V AND 277 CIRCUITS ARE ROUTED TO THE LIGHTING <br />CONTACTORS BY THE ELECTRICAL CONTRACTOR. <br />8. CONTROLS CONTRACTOR TO PULL AND TERMINATE LOW <br />VOLTAGE (24V) CONTROL WIRE FROM LIGHTING CONTACTOR <br />TO THE EMS PANEL. BASED ON THE FUNCTION OF EACH <br />CONTACTOR. <br />9. EMS—C TO REMOVE ALL UN —USED CONDUCTIONS AND <br />LIGHTING CONTACTORS <br />10. EMS—C TO PROVIDE AS BUILD I IGHTING CONTACTORS <br />SCHEDULE MOUNTED ON THE INSIDE COVER OF THE PANEL <br />DOOR OR OUTSIDE THE ENCLOSURE_ <br />11. REPLACE = REPLACE EXISTING CONTACTOR WITH NEW SIZE <br />CONTACTOR AS SHOWN ON THE SCHEDULE AND DISREGARD <br />EXISTING CONTACTOR <br />12. NEW = PROVIDE AND INSTALL NEW CONTACTOR. <br />13. REMOVE = REMOVE AND DISREGARD EXISTING CONTACTOR <br />I EGEND <br />LIGHT/DASHED = EXISTING <br />DARK/D.ASHED NEW WIRING <br />DARK/SOLID = NEW ITEM � <br />CONTACTOR ENCLOSURES KEY NOTES: <br />120V CIRCUIT BY EC. <br />0 MOUNTED FUSE HOLDER WITH 16A FUSE. <br />(3: CONTINUE TO EACH REAL Y AS INDICATED ON RELAY 1. <br />0 PROVIDE LABILE INDICATING RELAY NUMBER TO MATCH <br />CONTACTOR NUMBER FOR CLARITY. <br />ROUTE INDICATED CONDUCTORS FROM RELAY TO <br />CONTACTOR AS SHOWN. TYPICAL OF ALL <br />CONTACTORS IN PANEL. ROUTE CONDUCTORS <br />IN 1"X1" DIN RAIL. <br />0 NEUTRAL BUSS. PROVIDE POSITION TO MATCH CONTACTOR QUANITY. <br />PROVIDE NEW CONTACTORS TO ELECTRICAL CONTACTOR WHERE NOTED ON <br />THE LIGHTING CONTACTOR SCHEDULE WITH REPLACE OR NEW. <br />0 NEW CONTACTOR. SEE SCHEDULE ON THIS SHEET <br />FOR POI E COUNT. EMS—C TO PROVIDE LTG FUNCTION VIA RELAY. <br />EC TO MAKE ALL REQUIRED CONNECTIONS, <br />C) GROUND FROM BACK PLATE TO CABINET AND DOOR. <br />(1 120V CONTROL CIRCUIT BY ELECTRICAL. <br />1 1 CONTACTOR CONTROI CONDUCTORS. SHOWN AS TYPICAL REFERENCE <br />FROM EACH RELAY. <br />�2 ADD NEW 24V R:FLAYS WHERE NEEDED FOR EACH NEW CONTACTOR. TEST <br />RELAY FOR PROPER FUNCTION. REPLACE WITH NEW IF RELAY DOES NOT <br />OPERATE. <br />@3 INSTALL IN LINE FUSE HOLDER. <br />14 NEUTRAL BUSS. <br />] 5 MODIFY CONTROL CONDUCTOR TO MATCH NEW LIGHTING FUNCTION <br />DESCRIBED IN THE SCHEDULE. <br />16 MATCH EACH IOW VOLTAGE FUNCTION AT THE EMS PANEI TERMINAI <br />STRIP AND OUTPUT POINT. <br />LIGHTING <br />Contactor <br />Panel <br />Circuit <br />Polo <br />1 <br />Pole <br />Circuit <br />Panel <br />4S1 <br />2 <br />1 <br />POLES <br />10 <br />7 <br />4S1 <br />6 <br />2 <br />3 <br />4S1 <br />3 <br />3 <br />9 <br />4S1 <br />14 <br />4 <br />10 <br />5 <br />11 <br />6 <br />12 <br />Description HOM 25% <br />Contactor <br />Panel <br />Circuit <br />Pole <br />3 <br />Pale <br />ICircuit <br />Panel <br />4S1 <br />13 <br />1 <br />POLES <br />7 <br />2 <br />3 <br />3 <br />9 <br />4 <br />10 <br />5 <br />11 <br />6 <br />12 <br />Description HOM 50% <br />Contactor <br />POLES <br />`; <br />Description PARKING <br />Contactor <br />Panel <br />Circuit <br />Pole <br />7 <br />Pole <br />Circuit <br />Panel <br />4S1 <br />31 <br />1 <br />POLES <br />7 <br />4S1 <br />33 <br />2 <br />3 <br />4S1 <br />40 <br />3 <br />9 <br />4S1 <br />42 <br />4 <br />10 <br />5 <br />11 <br />4S1 <br />30 <br />6 <br />12 <br />Description HOM 50% <br />g, <br />POLES <br />10 <br />----a <br />r <br />0. <br />®� <br />E-70=1 <br />Description FM SIGNS <br />- - Contactor <br />Panel <br />Circuit <br />Pole <br />11 <br />Pole <br />lCircuit <br />Panel <br />4S3 <br />3 <br />1 <br />POLES <br />7 <br />4S3 <br />13 <br />2 <br />4S3 <br />11 <br />3 <br />9 <br />4S3 <br />5 <br />4 <br />10 <br />4S3 <br />6 <br />5 <br />11 <br />6 <br />12 <br />Contactor <br />Panel <br />Circuit <br />Pole <br />2 <br />Pole <br />Circuitl <br />Panel <br />4S1 <br />4 <br />1 <br />POLES <br />6 <br />7 <br />T_ <br />2 <br />3 <br />4S1 <br />10 <br />3 <br />9 <br />4S1 <br />16 <br />4 <br />10 <br />4S1 <br />19 <br />5 <br />11 <br />4S1 <br />22 <br />6 <br />12 <br />Description HOM 50% <br />Contactor <br />Panel <br />Circuit <br />Pole <br />4 <br />Pole <br />lCircuit <br />Panel <br />4S1 <br />20 <br />1 <br />POLES <br />12 <br />7 <br />20 <br />2S2 <br />4S1 <br />26 <br />2 <br />3 <br />29 <br />2S2 <br />4S1 <br />24 <br />3 <br />9 <br />27 <br />252 <br />4S3 <br />42 <br />4 <br />10 <br />25 <br />2S2 <br />2S2 <br />13 <br />5 <br />6 <br />11 <br />12 <br />22 <br />24 <br />2S2 <br />2S2 <br />Description VESTIBULE <br />Contactor <br />Panel <br />Circuit <br />Pole <br />6 <br />Pole <br />Circuit <br />Panel <br />4S1 <br />13 <br />1 <br />POLES <br />7 <br />4S1 <br />15 <br />2 <br />8 <br />4S3 <br />26 <br />3 <br />9 <br />4S3 <br />23 <br />4 <br />10 <br />4S2 <br />36 <br />5 <br />11 <br />4S3 <br />30 <br />1 6 <br />12 <br />Description PEM <br />Contactor <br />Panel <br />Circuit <br />Pole <br />8 <br />Pole <br />Circuit <br />Panel <br />4S3 <br />36 <br />1 <br />POLES <br />2 <br />7 <br />4S3 <br />33 <br />2 <br />3 <br />3 <br />9 <br />4 <br />10 <br />5 <br />11 <br />6 <br />12 <br />Description PARKING <br />- <br />Contactor <br />Panel <br />Circuit <br />Pole <br />10 <br />Pole <br />Circuit <br />Panel <br />4S1 <br />17 <br />1 <br />POLES <br />12 <br />7 <br />41 <br />4S1 <br />4S1 <br />26 <br />2 <br />3 <br />4S1 <br />23 <br />3 <br />9 <br />4S1 <br />32 <br />4 <br />10 <br />4S1 <br />34 <br />5 <br />11 <br />4S1 <br />39 <br />6 <br />12 <br />Description FM SIGNS <br />- - Contactor <br />Panel <br />Circuit <br />Pole <br />12 <br />Pole <br />Circuit <br />Panel <br />4S3 <br />7 <br />1 <br />POLES <br />7 <br />4S3 <br />9 <br />2 <br />2 <br />4S3 <br />32 <br />3 <br />9 <br />4 <br />10 <br />5 <br />11 <br />6 <br />12 <br />Contactor <br />Panel <br />Circuit <br />Pole <br />1 <br />Pole <br />Circuit <br />Panel <br />4M1 <br />3 <br />1 <br />POLES <br />12 <br />7 <br />23 <br />2M1 <br />41V11 <br />9 <br />2 <br />3 <br />23 <br />21VI2 <br />41V11 <br />15 <br />3 <br />9 <br />30 <br />21V12 <br />4 <br />10 <br />25 <br />2M1 <br />41V11 <br />19 <br />5 <br />11 <br />1 27 <br />211 <br />4NI1 <br />21 <br />6 <br />12 <br />29 <br />2M1 <br />Contactor <br />Panel <br />Circuit <br />Pole <br />2 <br />Pole <br />Circuit <br />Panel <br />4M1 <br />1 <br />1 <br />POLES <br />10 <br />7 <br />25 <br />4M1 <br />41VI1 <br />5 <br />2 <br />8 <br />27 <br />4M1 <br />4M1 <br />7 <br />3 <br />9 <br />29 <br />4M1 <br />4M1 <br />13 <br />4 <br />10 <br />411 <br />11 <br />5 <br />1 11 <br />4M1 <br />i 17 <br />6 <br />1 12 <br />Description <br />PARKING <br />Description <br />HOM 50% <br />Contactor <br />Contactor <br />Panel <br />Circuit <br />Pole <br />3 <br />Pole <br />Circuit <br />Panel <br />Panel <br />Circuit <br />Pole <br />4 <br />Pole <br />Circuit <br />Panel <br />4M1 <br />22 <br />1 <br />7 <br />_ <br />4M1 <br />2 <br />1 <br />7 <br />6 _ <br />4M1 <br />4M1 <br />24 <br />2 <br />3 <br />-�-_ <br />4M1 <br />8 <br />2 <br />3 <br />41VI1 <br />26 <br />3 <br />9 <br />4M1 <br />1 <br />10 <br />3 <br />9 <br />4M1 <br />23 <br />4 <br />POLES <br />10 <br />2M2 <br />2 <br />4 <br />POLES <br />10 <br />4M1 <br />30 <br />5 <br />12 <br />11 <br />2M2 <br />4 <br />5 <br />11 <br />411 <br />32 <br />6 <br />12 <br />2111 <br />6 1 <br />6 <br />12 <br />Description <br />SRVC DELUBAKERY <br />Description <br />ALE 26% <br />Contactor <br />Contactor <br />Panel <br />Circuit <br />Pole <br />5 <br />Polo <br />Circuit <br />Panel <br />Panel <br />Circuitj <br />Pole <br />6 <br />Pole <br />Circuit <br />Panel <br />4MI <br />21 <br />1 <br />7 <br />4M1 <br />4 <br />1 <br />7 <br />4M1 <br />23 <br />2 <br />3 <br />2 <br />3 <br />3 <br />9 <br />3 <br />9 <br />4 <br />POLES <br />10 <br />4 <br />POLES <br />10 <br />5 <br />2 <br />11 <br />5 <br />2 <br />11 <br />6 <br />1 1 <br />12 <br />1 <br />1 <br />1 <br />6 <br />1 <br />12 <br />Description SECURITY <br />Contactor <br />Panel <br />Circuit <br />Pole <br />7 <br />Pole <br />Circuit <br />Panel <br />4M1 <br />18 <br />1 <br />VOLES <br />7 <br />_ <br />L4M1 <br />13 <br />2 <br />3 <br />E41VI1 <br />32 <br />3 <br />9 <br />E4M1 <br />34 <br />4 <br />10 <br />5 <br />11 <br />6 <br />12 <br />Repalce with SIC contactors <br />Description <br />Contactor <br />Panel Circuit Pole 9 Pole Circuit Panel <br />4M3 24 1 7 <br />2 6 <br />3 9 <br />4 POLES 10 <br />5 2 11 <br />6 12 <br />Description GONDOLA <br />Contactor <br />Panel <br />Circuit <br />Pole <br />3 <br />Pole <br />Circuit <br />Panel <br />411 <br />19 <br />1 <br />POLES <br />2 <br />7 <br />4M1 <br />31 <br />2 <br />3 <br />3 <br />9 <br />4 <br />10 <br />5 <br />11 <br />6 <br />12 <br />Description <br />Contactor <br />Panel Circuit Pole 10 Pole Circuit Panel <br />1 7 <br />2 3 <br />3 9 <br />4 POLES 10 <br />5 11 <br />6 12 <br />ALL CIRCUITS FROM PANEL L4 1 SHOULD BYPASSED TO STAY ON AT ALL TIME <br />lighting Controls Schedule <br />Schedules Contactor Control <br />ON <br />OFF ON <br />OFF Notes <br />General Merchandize 25%: <br />HOM AREA 25% AMBIENT [GMD 25%] <br />6:00 <br />23:00 <br />Override button controlled, See below_ <br />GMD SKYLIGHT AREA 25% AMBIENT [GMD SKY 25%] <br />6:00 <br />23:00 <br />Interior light level sensor OFF and override button ON control <br />General Merchandize 50%: <br />GONDOLA LIGHTING OUTLET [GMD 50%] <br />7:00 <br />23:15 <br />DECOR / INTERIOR SIGN LIGHTING [GMD 50%1 <br />7:00 <br />23:15 <br />HOM AREA 50% AMBIENT [GMD 50%1 <br />7:00 <br />23:15 <br />GMD SKYLIGHT AREA 50% AMBIENT [GMD SKY 50%] <br />7:00 <br />23:15 <br />Interior light level sensor OFF for daylight harvesting <br />Food Merchandize 25% <br />FOD AREA 25% AMBIENT [FOD 25%] <br />6:00 <br />23:00 <br />Override button controlled, See below. <br />FOD SKYLIGHT AREA 257. AMBIENT [FOD SKY 25%] <br />6:00 <br />23:00 <br />Interior light level sensor OFF and override button ON control <br />Food Merchandize 50% <br />DECOR / INTERIOR SIGN LIGHTING [GMD 50%] <br />7:00 <br />23:15 <br />FOD AREA 50% AMBIENT i FOD 50%] <br />7:00 <br />23:15 <br />FOD SKYLIGHT AREA 50% AMBIENT [FOD SKY 50%] <br />7:00 <br />23:15 <br />Interior photocell OFF for daylight harvesting <br />ALE Merchandize 25% <br />ALE AREA 25% AMBIENT [ALE 25%] <br />6:00 <br />23:00 <br />Override button controller, See below. <br />ALE Merchandize 50% <br />ALE AREA 50% AMBIENT [ALE 50%] <br />IStandby <br />7:00 <br />23:15 <br />Lighting (SL) <br />FOD AREA SL [FOR SL] <br />— <br />— <br />Not controlled <br />GMD AREA SL [GMD SL] <br />— <br />— <br />Not controlled <br />GMD/FOD SL SKY[GMD/ FOD SKY SL] <br />_ <br />- <br />Interior light level sensor OFF for daylight harvesting <br />ALE AREA SL [ALE SL] <br />7:00 <br />23:15 <br />OAS AREA SL [CARDEN] <br />7:00 <br />23:15 <br />Exterior photocell/schedule ON and override button ON control <br />PHOTO, ELECTRONICS, MUSIC (PEM) SL [PEM SL] <br />6:00 <br />23:00 <br />PRX Si_ [PRX SL] <br />8:00 <br />22:00 <br />SERVICE MEAT/BAKERY/DELI [SVC DEPT] <br />4:00 <br />23:00 <br />Override button controlled, See below. <br />PHOTO, ELECTRONICS, MUSIC (REM) [PEM] <br />6:00 <br />23:15 <br />Override button controlled, See below. <br />JEWELRY [JLY] <br />8:00 <br />22:00 <br />Override button controlled, See below. <br />COFFEE [COFFEE] <br />6:00 <br />21:00 <br />VERIFY TIME WITH RPM. <br />PHARMACY—PLAYLAND (PRX—PLAYLD] <br />8:00 <br />22:00 <br />Wall switch in PRX. RR and Consult, by EC, reference only. <br />Override button controlled, See below. <br />HVAC [HVAC] <br />7:00 <br />23.15 <br />Override button controlled, See below. <br />HEAT (Where Applicable) <br />Heat Tape for Artie Region�HEAT TAPE] <br />Temp. <br />Temp. <br />Controlled by Outdoor Temperature Sensor <br />Block Heaters for(,�,diteka ONLY) [HEAT TAPE] <br />Temp, <br />Temp. <br />Controlled by Outdoor Temperature Sensor <br />Heat Radiant for E�NpM 1<a Only) [BAD HEAT] <br />Temp. <br />Temp. <br />Controlled by Entry Indoor Temperature Sensor <br />Exterior Light Level Senor Control: Light Level ON/OFF <br />PARKING LOT [PARKING] <br />Exterior photocell control <br />EXTERIOR SIGNAGE & PYLON I SIGNS] <br />7:00 <br />8:00 16:30 <br />23:00 <br />VESTIBULE AivIBIENT [VESTIBULE] <br />7:00 <br />23:15 <br />SECURITY [SECURITY] <br />Exterior photocell control <br />OAS AMBIENT [CA.RDEN] <br />7:00 <br />23:15 <br />Override button controlled, See below. <br />Motion Sensor Control Provided and installed by others. Reference Only. <br />STOCK ROOMS — <br />REFRIGERATED CASES [REFER —CS] <br />7:00 <br />23:15 <br />Override button controlled, See below. <br />Wall Switch Control: Provided and installed by others. Reference Only - <br />OFFICES — <br />ELECTRICAL / EMS / LOT SWEEP / FSR / BSM— <br />TELEPHONE / COMw1. ROOM — <br />IUNCHROOM/LOCKERS/EMP RR — <br />ME.AT PREP COOLER — <br />PRODUCE PREP COOLER — <br />Wall Timer Switch: Provided and installed by others. Reference Only. <br />r'OOLERS / FPE�77ER`' — <br />0 <br />Planning - Engineering <br />Portland, O <br />503.224.9560 <br />Vancouver, WA <br />360.695.7879 <br />Seattle, WA <br />206.749.9993 <br />www.mcknze.corn <br />DESIGN ®RIVEN I CLIENT FOCUSED <br />Client <br />FRED MEYER <br />STORES, INC. <br />00 SE 22ND ROAD, <br />PORT ND, OR 97202 <br />� 1 <br />PON` <br />���Q,J1 wU <br />MACKENZIE <br />2019 ALL RIGHTS RESERVED <br />THESE DRAWINGS ARE THE PROPERTY OF <br />MACKENZIE AND ARE NOT TO DE USED <br />OR REPRODUCED IN ANY MANNER, <br />WITHOUT PRIOR WRITTEN PERMISSION <br />Revision Schedule <br />Revision ®elt] Issue Date <br />DRAWN BY: GF <br />Momentary Button Location <br />Description <br />Schedule <br />Notea <br />DIRECTORS OFFICE <br />MASTER "ALL ON" <br />4 <br />hrs. <br />All lights on. <br />CHECKED BY: WC <br />FOD STOCK ENTRY & MAIN <br />SALES FI OOR <br />FOD 25%/FOD SKY 25% <br />Cf OVERRIDE 2 <br />hrs. <br />See overall <br />plan <br />for exact <br />location. <br />Two per area. <br />GMD STOCK ENTRY & MAIN <br />SALES FLOOR <br />GMD 25%/GMD SKY 25% <br />LT OVERRIDE 2 <br />hrs, <br />See overall <br />plan <br />for exact <br />location. <br />Two per area. <br />ALE STOCK ENTRY 8 MAIN <br />SALES FLOOR <br />ALE 25% LT OVERRIDE <br />2 <br />hrs. <br />See overall <br />plan <br />for exact <br />location. <br />Two per area. <br />— <br />PEM STOCK ENTRY & MAIN <br />SALES FLOOR <br />PEM IT OVERRIDE <br />2 <br />hrs. <br />See overcall <br />plan <br />for exact <br />location. <br />Two per area. <br />SHEET <br />OAS ENTRY AREA IN SALES <br />FLOOR <br />GARDEN OVERRIDE <br />2 <br />_hrs. <br />See overall <br />plan <br />for exact <br />location. <br />One per area. <br />PRX AREA IN CONSULT ROOM <br />PRX OVERRIDE <br />2 <br />hrs. <br />See overall <br />plan <br />for exact <br />location. <br />One per area. <br />JEWELRY AREA SALES FLOOR <br />JI Y OVERRIDE <br />2 <br />hrs. <br />See overall <br />plan <br />for exact <br />location. <br />One per area. <br />SERVICE DEPARTMENT AREA <br />REFRIGERATED CASES <br />SVC DEFT LT OVERRIDE <br />REFER —CS LT OVERRIDE <br />2 <br />2 <br />hrs. <br />hrs. <br />See overall <br />See overall <br />plan <br />plan <br />for exact <br />for exact <br />location. <br />location. <br />One per area. <br />One per area. <br />HVAC <br />HVAC OVERRIDE <br />2 <br />hrs. <br />See overall <br />plan <br />for exact <br />location. <br />- <br />One per areaEM7ml <br />_—�� <br />1 \ LIGHTING CONTACTOR SCHEDUE ES SCALE: NONE 2 LIGHTING CONTROLS SCHEDULE � SCALE: NON` <br />JOB NO. <br />Permit Set: 02/17/2020 <br />