C <br />24 VOLT CONNECTION WIRING- BEACON II <br />(CONDENSING UNIT WITH ONE EVAPORATOR) <br />CONDENSING UNIT EVAPORATOR <br />TB TR <br />WRS - by Bill <br />10 Fair i <br />i ) is number of evar, <br />n and liquid #1 is condensing unit to first evaporator coil, or to tee if;M <br />ilent Sine length includes long radius copper fittings and factory p-trap( <br />Z _ by Bill maps <br />Fairoaks Drive, Oakland, Thl 38901-351-4657 <br />Refrigerant type -A <br />Line Sizes OD "ACE: upper Systarn System Equiv Suct Equiv Lici bruin Line <br />Receiver <br />ue,t Luc 2 �i 1 Lig fttt3 Tess Une I�sgth Line Lgth Connection <br />Capacity 0% <br />: Individual fcca aty [temsRecinire <br />1-3,9' x 5/.8"x 3.68 180' 100' 3/4" 1=PT <br />4O <br />CIU C D-.tors, Evelp PC rnotors <br />1-3/9, X /9' x 44,134 3.68 10Q' 1 T0' _ 3/4 , PT <br />40 <br />C/U EC rrir toes, EuIapEC rn tors <br />?rE3 <br />- s- :t Factory installed an corldensincU unit: drier, Sl�iif'glass, S:G30TIan filer, servicevai+rs, aver+izaci receiver, hail guards and 5a year factory compressor warranty <br />Suction line insulation (evap. outlet to condensing unit) to be 1" minimum. Arm aflex or equal <br />-_ <br />ea E[ect ea Elect <br />10PD Accessories Eva Volt i ELA Accessayies <br />TN 38060 ® 001 =3 1-4 7 <br />AID DEFROST EVAPORATOR WIRING <br />EVAP. HEATER } <br />Room Sensor located on the FAN RELAY ALARM EPILN <br />wire clip o the top panel rlange. o <br />NO. <br />ROOM TEMP. SENSOR <br />ROOM TEMP. <br />Y L 2 PIN MOLEX <br />DEFROSTTEMP. BEACON 11 BOARD <br />GRN DEFROST TEMP. <br />2 PIN <br />SUCTION TEMP. SENSOR <br />BI_U <br />2 SUCTION <br />ION TEMP, 24 <br />V <br />SUCTION LINE SUCTION PRESSURE <br />3 PIN MOLEX <br />UTDOOR C <br />TEMP MILTI IN MILTI OUT SER COMP C +24V <br />O INPUT <br />SUCTION LINE <br />PRESSURE TRANSDUCER <br />RED <br />YEL <br />WH <br />GRN <br />i <br />SLU <br />R-101 l NTS <br />BLU GRN <br />� l <br />18 GA (FIELD WIRING) <br />MTR ) MTR MTR MTR. MTR <br />MOTOR WIRING SHOWN IS <br />TYPICAL, 1 TO 5 FANS <br />RED 1 1 YEL 1 WH <br />240V FIELD WIRING <br />T1 <br />T2 <br />T3 240V FIELD WIRING <br />CHECK-OUT & STARTUP <br />AFTER THE INSTALLATION HAS BEEN COMPLETED, THE FOLLOWING POINTS SHOULD BE COVERED BEFORE THE SYSTEM IS PLACED IN OPERATION: <br />(A) CHECK ALL ELECTRICAL AND REFRIGERANT CONNECTIONS, RE SURE THEY ARE ALL CORRECT AND TIGHT. <br />(B) CHECK VOLTAGE TAPS ON TRANSFORMER, THE TRANSFORMER IS SHIPPED WIRED TO 240 VOLTAGE TAP/CONNECTION, IF YOUR SUPPLY <br />VOLTAGE IS 200 VOLT SYSTEMS, CHANGE TO 206 VOLTAGE TAP, <br />(C) CHECK SETTING OF TIME DELAY RELAY FOR LOW PRESSURE SWITCH IN CONDENSING UNIT, IT SHOULD RE SET AT ONE MINUTES (THE <br />SECOND MARKER). <br />(D) CHECK HIGH AND LOW PRESSURE CONTROLS, PRESSURE REGULATING VALVES, OIL PRESSURE SAFETY CONTROLS, AND ALL OTHER <br />SAFETY CONTROLS AND ADJUST THEM, IF NECESSARY, <br />(E) ON FREEZERS ONLY, CHECK THE LOW PRESSURE SWITCH SETTING.IT MUST RE SET TO 0 PSIG CUT OUT, 10 PSIG CUT IN, TO ALLOW START <br />OPERATION, ESPECIALLY IN COLD AMBIENTS. <br />(F) LIQUID LINE SHOULD ALWAYS BE INSULATED. <br />(G) WIRING DIAGRAMS, INSTRUCTION BULLETINS, ETC, ATTACHED TO THE CONDENSING UNITS SHOULD BE READ AND FILED FOR FUTURE <br />REFERENCE. <br />(H) ALL FAN MOTORS ON AIR COOLED CONDENSERS, EVAPORATORS, ETC, SHOULD BE CHECKED FOR PROPER ROTATION. FAN MOTOR MOUNTS <br />SHOULD BE CAREFULLY CHECKED FOR TIGHTNESS AND PROPER ALIGNMENT. <br />(1) OBSERVE SYSTEM PRESSURES DURING CHARGING AND INITIAL OPERATION. DO NOT ADD OIL WHILE THE SYSTEM IS SHORT OF <br />REFRIGERANT UNLESS OIL LEVEL IS DANGEROUSLY LOW. <br />(J) CONTINUE CHARGING UNTIL SYSTEM HAS SUFFICIENT REFRIGERANT FOR PROPER OPERATION, DO NOT OVERCHARGE. REMEMBER THAT <br />BUBBLES IN A SIGHT GLASS MAY BE CAUSED BY A RESTRICTION AS WELL AS A SHORTAGE OF REFRIGERANT, <br />(K) DO NOT LEAVE UNIT UNATTENDED UNTIL THE SYSTEM HAS REACHED NORMAL OPERATING CONDITIONS AND THE OIL CHARGE HAS BEEN <br />PROPERLY ADJUSTED TO MAINTAIN THE OIL LEVEL AT THE CENTER OF THE SIGHT GLASS. <br />(L) AT INITIAL START-UP, THE SYSTEM MAY CYCLE OFF AT 2 MINUTES AND DISPLAY A LOW SUPERHEAT ERROR, THEN RESTART ITSELF. THIS <br />CYCLE MAY BE REPEATED A FEW TIMES. DO NOT SHUT THE SYSTEM OFF. LET THE SYSTEM RUN, AS IT MAY TAKE A FEW CYCLES FOR THE <br />ELECTRIC EXPANSION VALVE TO ATTAIN THE CORRECT SETTING FOR THE DESIRED SUPERHEAT. <br />CAUTION, EXTREME CARE MUST BE TAKEN IN STARTING COMPRESSORS FOR THE FIRST TIME AFTER SYSTEM CHARGING, AT THIS TIME, ALL OF THE OIL AND <br />MOST OF THE REFRIGERANT MIGHT BE IN THE COMPRESSOR CREATING A CONDITION WHICH COULD CAUSE COMPRESSOR DAMAGE DUE TO SLUGGING. <br />ACTIVATING THE CRANKCASE HEATER FOR 24 HOURS PRIOR TO STARTUP IS RECOMMENDED, IF NO CRANKCASE HEATER IS PRESENT, THEN DIRECTING A 500 <br />WATT HEAT LAMP OR OTHER SAFE HEAT SOURCE ON THE LOWER SHELL OF THE COMPRESSOR FOR APPROXIMATELY THIRTY MINUTES WILL BE BENEFICIAL IN <br />ELIMINATING THIS CONDITION WHICH MIGHT NEVER REOCCUR. <br />m <br />Gx <br />mrn <br />LOAD <br />TRANSFORMER <br />T1 <br />FACTORYWIRING <br />-- FIELD WIRING <br />/r� 3 <br />t 1 ,viz_10 <br />ELECTRICAL <br />® CHECK PRIMARY SUPPLY VOLTAGE. IF 200 V, <br />CHANGE TRANSFORMER WIRING IN THE COOLER <br />TO THE 203 V TAP <br />0 YES 0 NO <br />® CHECK COMPRESSOR AMPS FOR COOLER COMPRESSORS. <br />SHOULD MATCH NAMEPLATE. <br />0 YES 0 NO <br />PIPING <br />® IS SUCTION LINE TRAPPED AT THE COOLER? <br />0 YES 0 NO <br />® IS SUCTION LINE TRAPPED AT THE BLAST CHILLER? <br />0 YES 0 NO <br />DRAIN LINES <br />® ARE DRAIN LINES SLOPED PROPERLY? <br />0 YES 0 NO <br />IS DRAIN LINE TRAPPED OUTSIDE THE COOLER? <br />0 YES 0 NO <br />® IS DRAIN LINE TRAPPED OUTSIDE THE BLAST CHILLER? <br />0 YES 0 NO <br />INSULATION <br />e ARE LIQUID LINES FULLY INSULATED? <br />0 YES 0 NO <br />® ARE SUCTION LINES FULLY INSULATED? <br />0 YES 0 NO <br />SLOPE 1" TO 10' <br />SETTINGS <br />® CHECK BEACON 11 BOARD SETTINGS FOR THE <br />FOLLOWING <br />0 YES 0 NO <br />COOLER <br />REFRIGERANT TYPE <br />BOX SETPOINT TEMP, <br />SUPERHEAT <br />NO. OF DEFROST/DAY <br />DEFROST END TEMP <br />SYSTEM CHECKS <br />o CHECK COMPRESSOR SUPERHEAT FOR THE <br />COOLER (SHOULD BE BETWEEN 20°F. & 30°F.) <br />0 YES ONO <br />® FORCE UNIT INTO A DEFROST CHECK HEATER <br />AMPS. SHOULD MATCH NAMEPLATE AMPS. <br />0 YES ONO <br />® DID BLAST CHILLER AND COOLER CYCLE OFF ON LPS AT <br />0 YES ONO <br />® CHECK LPS TIME DELAY RELAYS. SHOULD BE SET <br />AT 1 MINUTE FOR THE COOLER S & BLAST CHILLER <br />0 YES ONO <br />a IS THE SIGHT GLASS FREE OF BUBBLES? <br />0 YES 0 NO <br />® ARE THE COOLER FANS AT PROPER SPEEDS? <br />0 YES 0 NO <br />e CHECK SYSTEM FOR REFRIGERANT LEAKS. ARE THERE ANY LEAKS <br />ON THE COOLER, CONDENSING UNIT OR INTERCONNECTING <br />PIPING? <br />0 YES ONO <br />CHECK SYSTEM PIPING FOR UNUSUAL VIBRATION OR NOISE. IS <br />THERE ANY UNUSUAL VIBRATION OR NOISE ON THE COOLER, <br />CONDENSING UNIT OR INTERCONNECTING PIPING? <br />0 YES ONO <br />t;�< 11 <br />lY <br />R-101 l SCALE 1/8" - -0" <br />R-101 I NTS <br />KEYNOTES <br />1 NEW CONDENSING UNIT PLACED ON GROUND SETTING ON NEW CONCRETE <br />PAD. UNIT WEIGHT IS 332 LBS <br />2 CONDENSING UNIT: DRIER, SIGHT GLASS, SUCTION FILTER, SERVICE VALVES <br />ARE TO BE FACTORY INSTALLED <br />3 314" ARMAFLEX SUCTION LINE INSULATION FOR FULL RUN BETWEEN <br />CONDENSING UNIT AND EVAPORATORS <br />4 WALL PENETRATION FOR REFRIGERATION LINES AND ELECTRICAL CONDUIT <br />TO BE SEALED <br />5 SUPPORT CONDUITS AND REFRIGERATION PIPES @ 43" O/C WITH UNISTRUT <br />P-1000 <br />6 INSTALL NEW CONDENSATE DRAIN LINES BETWEEN NEW EVAPORATORS TO <br />NEW WALL MOUNTED FUNNEL DRAIN; MAINTAIN 6" AIR GAP <br />EVAP EVAP <br />COIL COIL <br />EACH COIL TO BE TRAPPED ONCE BEFORE ENTERING AN <br />UN -TRAPPED MAIN. TRAP FREEZER COIL OUTSIDE FREEZER <br />P-TRAPS COMPARTMENT AND TRACE LINE WITH HEAT TAPE. <br />WALL FUNNEL DRAIN WITH A MINIMUM OF 6" AIR GAP <br />0 0 0 <br />•BALL FUNNEL DRAIN. SEE FLOOR PLAN. <br />f � <br />i ' I t l it <br />1-1/4- UNIT STRUT RUN PERPENDICULAR <br />COOLERTO ROOF STRUCTURAL PANEL <br />COOLER/FREEZER <br />CEILING PANEL <br />812 SW WASHINGTON ST, SUITE 800 <br />PORTLAND OREGON 97205 <br />PHONE 503/226.0622 <br />FAX 503/226.0626 <br />WWW. MCA=ARCHITECTS.COM <br />Cn <br />U <br />®'r, <br />F, <br />x <br />M: 00 <br />U <br />> <br />s <br />U <br />P- <br />' <br />-I <br />PROJECT NO: <br />DRWN BY: CHK'D BY: <br />DATE: 02-04-22 <br />R-101 <br />OC COPY1tIGHT <br />