Laserfiche WebLink
DUCT HTTING 5YMBOL5 <br />TURNING <br />VANES <br />W2 -2 <br />MITER TEE <br />41 <br />0 <br />CL <br />U <br />4- <br />U_ <br />0 <br />m <br />C� <br />• r c <br />W1 OR GRILLE W1 r <br />W2 B, TURNING B`� <br />SUPPLY & W2-A H VANES SUPPLY & <br />RETURN RETURN <br />MITER ELBOW BRANCH <br />RECTANGULAR <br />HVAC 5YMBOL5 <br />------------- <br />INTERNALLY INSULATED SHEET METAL (SINGLE LINE) <br />INTERNALLY INSULATED SHEET METAL (DOUBLE LINE) <br />BARE OR INSULATED METAL DUCT (SINGLE LINE) <br />BARE OR INSULATED METAL DUCT (DOUBLE LINE) <br />o <br />FLEX DUCT (SINGLE LINE) <br />ROUND DUCT: UP OR DOWN <br />B <br />BUTTERFLY DAMPER <br />BDD <br />BACK DRAFT DAMPER <br />OBD <br />OPPOSED BLADE DAMPER <br />DAD-1 <br />OUTSIDE AIR DAMPER No.1 <br />SD <br />SMOKE DETECTOR <br />I <br />T <br />THERMOSTAT: WALL MOUNTED <br />S <br />S <br />SENSOR <br />HSW <br />HIGH SIDE WALL SUPPLY OR RETURN <br />LSW <br />LOW SIDE WALL SUPPLY OR RETURN <br />ECG <br />EGGCRATE GRILLE <br />RA <br />RETURN AIR: UP OR DOWN <br />OSA <br />OUTSIDE AIR: UP OR DOWN <br />SA <br />SUPPLY AIR: UP OR DOWN <br />110 —AIR <br />VOLUME, CFM <br />8x8 - <br />DIFFUSER NECK SIZE <br />4W —BLOW DIRECTIONS <br />RB <br />REBALANCE EXISTING DIFFUSER TO THIS CFM <br />(30) — <br />RELIEF AIR CFM THRU UNDERCUT OF DOOR <br />AND FLOW DIRECTION <br />RTU-1 <br />ROOF TOP UNIT NO. 1 <br />CONNECT TO EXISTING <br />REMOVE TEMPORARY CAP & CONNECT <br />jK <br />EXISTING TO REMAIN <br />CAP EXISTING <br />TEMPORARILY CAP EXISTING <br />N <br />NEW <br />R <br />RELOCATE EXISTING <br />---------0000-A <br />X <br />REMOVE EXISTING <br />W/ <br />WITH <br />* PER ASHRAE 62.1-2010 TABLE 6-1 AND 2018 IMC TABLE 403.3 WITH WASHINGTON AMENDMENTS. <br />OfT P PACKAGE HEAT PUMP UNITS <br />MANUFACTURER NOMINAL MOTOR COOUNG HEATING I E ELECTRIC HEAT MIN WEIGHT <br />DESK AND MODEL O ®g & 7 TONS CFM ESP FOP CAPACITY CAPACITY EER LEER COP STEPS HEATER OSA LBS <br />MBH MBH® KW CEO R <br />R T U-1 TRANE WSH150E3RN 12.5 5000 0.699 3.0 146.0 136.0 10.6 13.5 3.2 2 36 — 2455 <br />0 NOTES: <br />1. PROVIDE WITH ECONOMIZER (OUTSIDE AND RETURN <br />AIR DAMPERS) AND BAROMETRIC RELIEF <br />2. PROVIDE SEISMIC BRACING/SUPPORT FOR ALL ROOF TOP <br />PACKAGE HEAT PUMP UNITS. <br />3. VERIFY VOLTAGE AND PHASE <br />4. TOTAL CAPACITY @ 95®F OUTSIDE, 67®F WB <br />5. TOTAL CAPACITY @ 477 OUTSIDE, 43°F WB <br />6. PROVIDE WITH RETURN AIR SMOKE DETECTOR. <br />7. PROVIDE WITH TWO SPEED MOTOR <br />MECHANICAL CODE NOTES: <br />SECTIONS LISTED REFER TO THE 2018 WASHINGTON STATE ENERGY CODE <br />EQUIPMENT SIZING — <br />LOAD CALCULATIONS AND EQUIPMENT SIZING PER SECTIONS C403.1.2 AND <br />C403.3. <br />VENTILATION PER SECTION C403.2.2 AND CHAPTER 4 OF THE 2018 IMC. <br />HVAC CONTROLS — <br />THERMOSTATS TO BE 7 DAY PROGRAMMABLE WITH NIGHT SETBACK. <br />MINIMUM DEADBAND FOR THERMOSTATS 5 DEGREE F. PER SECTION <br />C403.4. <br />THERMOSTATS TO PROVIDE START/STOP CONTROLS PER SECTION <br />C403.4.2.3. <br />OSA, EXHAUST, RELIEF AND RETURN AIR DAMPERS TO MEET <br />REQUIREMENTS OF SECTIONS C403.7.8. <br />DUCT SYSTEMS — <br />ALL DUCTWORK TO BE CONSTRUCTED, SEALED AND INSULATED PER <br />SECTION C403.10.1. <br />ECONOMIZERS — <br />ALL ECONOMIZERS SHALL PROVIDE 100% OF THE DESIGN SUPPLY AIR AS <br />OUTSIDE AIR PER SECTION C403.5.3.1 <br />PROVIDE ECONOMIZERS WITH FIXED DRY BULB (757) HIGH —LIMIT SHUTOFF <br />PER SECTION C403.5.3.3 <br />SYSTEMS WITH ECONOMIZERS SHALL BE CAPABLE OF RELIEVING EXCESS <br />OUTDOOR AIR DURING ECONOMIZER OPERATION PER SECTION C403.5.3.4. <br />BUILDING DOCUMENTATION AND CLOSEOUT SUBMITTALS — <br />DOCUMENTS FOR RECORD, MANUALS, COMPLIANCE AND OPERATIONAL <br />TRAINING PER SECTION C103.6 TO BE PROVIDED. <br />3 I I I I <br />I I 6 I i <br />I i i i <br />I I B i E <br />I q I 3 E <br />T1 AC FLOOR P"LAN <br />t <br />812 SW WASHINGTON ST, SMITE 800 <br />PORTLAND OkEGON 97205 <br />PHONE 503 226.0622 <br />FAX 5031226°0626 <br />WWW,MCA-ARCHITEC C`S.COM <br />nj <br />ro <br />,47W. <br />SNONAL <br />2/2/2022 <br />22011 <br />February 2, 2022 <br />to <br />zj Lo 0 <br />co <br />Lo ol� <br />LL=>� <br />U� <br />0 <br />® [_ <br />co <br />0 r� <br />U <br />I <br />U <br />PROJECT NO: 21-127 <br />DRWN BY: �C �ChIIC'D BY: sC <br />COPYRIGHT <br />m <br />