SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL <br />Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) <br />VMP <br />37.13 V <br />IMP <br />10.77 A <br />VOC <br />45.3 V <br />ISC <br />11.14 A <br />TEMP. COEFF. VOC <br />-0.27%/K <br />PTC RATING <br />376.55 W <br />MODULE DIMENSION <br />74"(L) x 41.1"(W) <br />PANEL WATTAGE <br />1400 W <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL <br />ENPHASE IQ8PLUS-72-2-US (240V) <br />MAX DC SHORT CIRCUIT CURRENT <br />15 A <br />CONTINUOUS OUTPUT CURRENT <br />1.21 A <br />AMBIENT TEMPERATURE SPECS <br />RECORD LOW TEMP <br />-5°C <br />AMBIENT TEMP (HIGH TEMP 2%) <br />26°C <br />CONDUIT HEIGHT <br />7/8" <br />ROOF TOP TEMP <br />90°C <br />CONDUCTOR TEMPERATURE RATE <br />48°C <br />MODULE TEMPERATURE COEFFICIENT OF VOC <br />-0.27%/K <br />PERCENT OF VALUES <br />NUMBER OF CURRENT CARRYING <br />CONDUCTORS IN EMT <br />0.80 <br />4-6 <br />0.70 <br />7-9 <br />0.50 <br />10-20 <br />VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX <br />FOR BRANCH CIRCUIT #1 OF 8 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.30% <br />FOR BRANCH CIRCUIT #2 OF 8 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.30% <br />VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX <br />VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br />= (1.21 AMP X 8) X (0.00129 OHMS/FT) X (40 FT X 2) <br />= 9.68 AMPS X 0.00129 OHMS/FT) X 80 FT <br />= 1.00 VOLTS <br />%VRISE = 1.00 VOLTS = 240 VOLTS = 0.42% <br />THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX IS 0.42% <br />VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE NON FUSED AC DISCONNECT <br />VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br />= (1.21 AMP X 16) X (0.00051 OHMS/FT) X (5 FT X 2) <br />= 19.36 AMPS X 0.00051 OHMS/FT) X 10 FT <br />= 0.10 VOLTS <br />%VRISE = 0.10 VOLTS + 240 VOLTS = 0.04% <br />THE VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE NON FUSED AC DISCONNECT IS 0.04% <br />VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP <br />VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br />= (1.21 AMP X 16) X (0.00051 OHMS/FT) X (5 FT X 2) <br />= 19.36 AMPS X 0.00051 OHMS/FT) X 10 FT <br />= 0.10 VOLTS <br />%VRISE = 0.10 VOLTS - 240 VOLTS = 0.04% <br />THE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP IS 0.04% <br />TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS <br />0.3% + 0.42% + 0.04% + 0.04% = 0.80% <br />Lumio <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(16) Q CELLS <br />Q.PEAK DUO BILK ML-G10+ <br />(40OW) <br />(16) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 6.400 kWDC <br />AC SYSTEM SIZE: 4.800 kWAC <br />REVISIONS <br />DESCRIPTION DATE REV <br />PROJECT NAME & ADDRESS <br />Lu <br />`1 <br />J <br />= W <br />LU (_) <br />Z <br />= W <br />Q 0 <br />ry U) <br />Q W <br />= Q� <br />U <br />w <br />N <br />Q <br />U) <br />Z) <br />ri <br />0 <br />N <br />co <br />d') <br />Q <br />W <br />ry <br />W <br />W <br />ry <br />0 <br />Q <br />0 <br />Fy <br />O <br />J <br />LL <br />Lo <br />N <br />Lo <br />I DATE:12/6/2022 1 <br />SHEET NAME <br />SPECIFICATIONS <br />& NOTES <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-8 <br />