Laserfiche WebLink
1❑ <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD SIDES MAY <br />BE ENERGIZED IN THE OPEN POSITION <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION, MAIN SERVICE <br />DISCONNECT, AC DISCONNECT, AC COMBINER, <br />INVERTER <br />PER CODE: NEC 690.13(B) <br />NACAUTION I <br />DUAL POWER SOURCE <br />SECOND SOURCE IS <br />PHOTOVOLTAIC <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT/ AC DISCONNECT/ <br />MAN SERVCE PANEL/ REVENUE METER/ AC <br />COMBINER <br />PER CODE: NEC 705.12(C) <br />3 CAUTION: SOLAR ELECTRIC <br />SYSTEM CONNECTED <br />I ARFI I (-)CATION <br />POINT OF INTERCONNECTION & INVERTER <br />PER CODE: NEC 690.15 & 690.13(B) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID <br />SHUTDOWN SWITCH <br />TO THE 'OFF' <br />POSITION TO SHUT SO4AR ELECTRic <br />DOWN PV SYSTEM PV PANELE <br />AND REDUCE <br />SHOCK HAZARD IN <br />THE ARRAY <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE <br />PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE <br />AC DISCONNECT <br />PER CODE: 2020 NEC 690.56(C) <br />F5] <br />LABEL LOCATION: <br />AC DISCONNECT <br />PER CODE: NEC 690.56(C)(2) <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OUTPUT CURRENT 19.36 AMPS <br />NOMINAL OPERATING AC VOLTAGE 240 VOLTS <br />LABEL LOCATION: <br />INTERACTIVE SYSTEM POINT OF INTERCONNECTION <br />PER CODE: NFPA 70, NEC 690.54 <br />7 WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />PLACE THIS LABEL AT P.O.C. TO SERVICE <br />DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL <br />(AND SUBPANEL IF APPLICABLE)) <br />PER CODE: NEC 705.12(B)(3)(2) <br />I ARFI 1OCATION- <br />CONDUIT <br />PER CODE: NEC 690.31(D)(2) <br />❑9 CAUTION: SOLAR CIRCUIT <br />10 <br />I ARFI 1OCATION- <br />MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, <br />ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND <br />ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES <br />PER CODE: IFC 606.11.1.4 <br />LABEL LOCATION: <br />INVERTER & JUNCTION BOXES (ROOF) <br />PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) <br />ADHESIVE FASTENED SIGNS <br />THE LABEL SHALL BE SUITABLE FOR THE <br />ENVIRONMENT WHERE IT IS INSTALLED. <br />• WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL <br />FIELD APPLIED LABELS, WARNING AND MARKINGS <br />SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) <br />FIELD MARKING]. <br />• ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF <br />PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER <br />RESISTANT [IFC 605.11.1.3] <br />Lumio <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(16) 0 CELLS <br />Q.PEAK DUO BILK ML-G10+ <br />(400W ) <br />(16) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 6.400 kWDC <br />AC SYSTEM SIZE: 4.800 kWAC <br />REVISIONS <br />DESCRIPTION I DATE REV <br />PROJECT NAME & ADDRESS <br />Q <br />07 <br />Z) <br />M <br />O <br />N <br />00 <br />O <br />w <br />J <br />LU <br />LLJ <br />U w <br />Z <br />= <br />g <br />0 W <br />- > <br />W W <br />U <br />p <br />Lu <br />Q <br />N <br />p <br />O <br />J <br />LL <br />N <br />DATE: 12/6/2022 <br />SHEET NAME <br />SIGNAGE <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-9 <br />