INSTALLATION -CONTINUED <br />Piping Connections —Continued <br />Gas Supply Piping —Continued <br />Table 15. Gas Supply Line Sizes <br />Diameter of Pi a (inches) " <br />Length <br />1/2 <br />3/4 1 <br />1-114 <br />1-1/2 <br />2 <br />of Pipe, <br />(Feet) <br />Natural <br />Gas <br />Propane <br />Natural' Natural <br />Gas .' Propane Gas ; <br />Propane <br />Natural" <br />;Gas <br />' <br />Propane <br />Natural <br />Gas <br />Pne <br />ropa <br />Natural <br />Gas <br />Propane <br />Cubic Feet per Hour <br />20 <br />92 <br />56 <br />190 <br />116 <br />350 <br />214 <br />730 <br />445 <br />1100 <br />671 <br />2100 <br />1281 <br />30 <br />73 <br />45 <br />152 <br />93 <br />285 <br />174 <br />590 <br />360 <br />890 <br />543 <br />1650 <br />1007 <br />40 <br />63 <br />38 <br />130 <br />79 <br />245 <br />149 <br />500 <br />305 <br />760 <br />464 <br />1450 <br />885 <br />50 <br />56 <br />34 <br />115 <br />70 <br />215 <br />131 <br />440 <br />268 <br />670 <br />409 <br />1270 <br />775 <br />60 <br />50 <br />31 <br />105 <br />64 <br />195 <br />119 <br />400 <br />244 <br />610 <br />372 <br />1105 <br />674 <br />70 <br />46 <br />28 <br />96 <br />59 <br />180 <br />110 <br />370 <br />1 226 <br />560 <br />342 <br />1050 <br />641 <br />80 <br />43 <br />26 <br />90 <br />55 <br />170 <br />104 <br />350 <br />214 <br />530 <br />323 1 <br />990 <br />604 <br />90 <br />40 <br />24 <br />84 <br />51 <br />160 <br />98 <br />320 <br />195 <br />490 <br />299 <br />930 <br />567 <br />100 <br />38 <br />23 <br />79 <br />48 <br />150 <br />92 <br />305 <br />186 <br />460 <br />281 <br />870 <br />531 <br />125 <br />34 <br />21 <br />72 <br />44 <br />130 <br />79 <br />275 <br />168 <br />410 <br />250 <br />780 <br />476 <br />150 <br />31 <br />19 <br />64 <br />39 <br />120 <br />73 1 <br />250 <br />153 <br />380 <br />232 <br />710 <br />433 <br />175 <br />28 <br />17 <br />59 <br />36 <br />110 <br />67 <br />225 <br />137 <br />350 <br />214 <br />650 <br />397 <br />200 <br />26 <br />i6 <br />55 <br />34 <br />100 <br />61 <br />210 <br />128 <br />320 1 <br />195 1 <br />610 <br />372 <br />Supply Piping Connections <br />• Install a ground joint union and manual shutoff valve upstream of the unit control system, as shown in Figure 9. <br />• The 1/8-inch plugged tapping in the manual shutoff valve in Figure 9 provides connection for a supply line pressure <br />test gauge. <br />• The National Fuel Gas Code requires the installation of a trap with a minimum 3-inch drip leg (see Figure 9). Local <br />codes may require a drip leg longer than 3 inches (typically 6 inches). To permit burner removal, this drip leg must <br />extend beyond the edge of the heater. <br />• Leak -test all connections by brushing on a leak -detecting solution. Bleed trapped air from gas lines as needed. <br />• The gas connection is made at the pipe nipple that extends outside the cabinet, as shown in Figure 9. Gas <br />connection sizes are listed in Table 16. <br />Ground Joint Union <br />To Gas Valve.F. r- Manual shutoff <br />(inside the <br />cabinet) <br />Drip tFr rn Gas Supply <br />Leg (horizontal or vertical) <br />i <br />Pipe nipple extending <br />outside the cabinet <br />To Gas Valve <br />(inside the q-C <br />cabinet) <br />Ground <br />Joint <br />Union <br />Figure 9. Gas Connections <br />-- Manual shutoff <br />Drip <br />Leg <br />20 UBX-UBZ-UDX-UDZ-IOM (12-22) 1034344-1 <br />