Table 8, Weights <br />Unit`S�ze <br />Modell <br />030: ;I045 ; :; O00 '075 100 , <br />,'125:: i50 : i75 ,i200 225 250. 35b:• <br />Pounds <br />(kg : ; <br />UBX <br />84 <br />89 <br />102 <br />108 <br />168 <br />171 <br />300 <br />320 <br />320 <br />385 <br />400 <br />458 <br />494 <br />506 <br />(38) <br />40 <br />46 <br />49) <br />76 <br />78 <br />136 <br />145 <br />(145 <br />175} <br />181 <br />208) <br />224 <br />230 <br />UBZ <br />85 <br />90 <br />103 <br />109 <br />169 <br />172 <br />3 11 <br />321 <br />321 <br />386 <br />401 <br />459 <br />495 <br />507 <br />(39) <br />(41) <br />(47) <br />(49) <br />(77) <br />(78) <br />(137) <br />(146) <br />(146) <br />(175) <br />(182) <br />(208 <br />(225) <br />(230) <br />UDX <br />57 <br />62 <br />71 <br />76 <br />101 <br />106 <br />178 <br />193 <br />193 <br />211 <br />223 <br />277 <br />303 <br />316 <br />(26) <br />(28} <br />(32) <br />(34) <br />(46) <br />(48) <br />{81} <br />(88) <br />(88) <br />(96) <br />(101) <br />(126) <br />(137) <br />(143) <br />UDZ <br />58 <br />63 <br />7i <br />77 <br />102 <br />107 <br />179 <br />194 <br />194 <br />212 <br />224 <br />278 <br />304 <br />317 <br />(35) <br />(46) <br />(49) <br />(81) <br />(88) <br />(88) 1 <br />(96) <br />(102) <br />(126) <br />(138) <br />(144) <br />Combustion Air Requirements <br />� e <br />Do not install a unit in a confined space without providing wallopenings leadin to and, from <br />' p p gg from <br />the space. <br />• Unit heater models UBX and UDX are designed to take combustion air from the space in which <br />the unit is installed and are not designed for connection to outside combustion air intake ducts. <br />Connecting outside air ducts voids the warranty and could cause hazardous operation. <br />• For UBZ and UDZ models, refer to the combustion air requirements in the venting instructions listed in Table 1. <br />• UBX and UDX models must be supplied with the air that enters into the combustion process and is then vented <br />to the outdoors. Sufficient air must enter the equipment location to replace that which is exhausted through the <br />heater vent system. <br />• In the past, the infiltration of outside air assumed in heat loss calculations (one air change per hour) was assumed <br />to be sufficient. However, current construction methods, which use more insulation, vapor barriers, tighterfitting and <br />gasketed doors and windows, weather-stripping, and/or mechanical exhaust fans, may now require the introduction <br />of outside air through wall openings or ducts. <br />• Under all conditions, enough air must be provided to ensure there will not be a negative pressure condition within <br />the equipment room or space. <br />• Requirements for combustion air and ventilation air depend upon whether the unit is located in a confined or <br />unconfined space. A confined space is defined as a space whose volume is <50 cubic feet per 1,000 BTUh of <br />the installed appliance input rating. An unconfined space is defined as a space whose volume is >50 cubic feet <br />per 1,000 BTUh of the installed appliance input rating. <br />• For confined space installation of UBX and UDX models (including those with CV option), provide openings <br />(depending on the combustion air source) near the floor and ceiling for ventilation and air for combustion, as shown <br />in Figure 4 and as listed in Table 9. <br />NOTE: For further details on supplying combustion air to a confined space, refer to the National <br />Fuel Gas Code ANSI Z223.1 a (latest edition). <br />UBX-UBZ-UDX-UDZ-IQM (12-22) 1034344-1 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.