SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / MODEL <br />Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) <br />VMP <br />37.13 V <br />IMP <br />10.77 A <br />VOC <br />45.3 V <br />ISC <br />11.14 A <br />TEMP. COEFF. VOC <br />-0.27%/K <br />PTC RATING <br />376.55 W <br />MODULE DIMENSION <br />74"(L) x 41.1"(W) <br />PANEL WATTAGE <br />1400 W <br />INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL <br />ENPHASE IQ8PLUS-72-2-US (240V) <br />MAX DC SHORT CIRCUIT CURRENT <br />15 A <br />CONTINUOUS OUTPUT CURRENT <br />1.21 A <br />AMBIENT TEMPERATURE SPECS <br />RECORD LOW TEMP <br />-5°C <br />AMBIENT TEMP (HIGH TEMP 2%) <br />26°C <br />CONDUIT HEIGHT <br />7/8" <br />ROOF TOP TEMP <br />90°C <br />CONDUCTOR TEMPERATURE RATE <br />48°C <br />MODULE TEMPERATURE COEFFICIENT OF VOC <br />-0.27%/K <br />PERCENT OF VALUES <br />NUMBER OF CURRENT CARRYING <br />CONDUCTORS IN EMT <br />0.80 <br />4-6 <br />0.70 <br />7-9 <br />0.50 <br />10-20 <br />VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX <br />FOR BRANCH CIRCUIT #1 OF 12 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.65% <br />FOR BRANCH CIRCUIT #2 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.46% <br />VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX <br />VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br />= (1.21 AMP X 12) X (0.00205 OHMS/FT) X (58 FT X 2) <br />= 14.52 AMPS X 0.00205 OHMS/FT) X 116 FT <br />= 3.45 VOLTS <br />%VRISE = 3.45 VOLTS = 240 VOLTS = 1.44% <br />THE VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX IS 1.44% <br />VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE FUSED AC DISCONNECT <br />VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br />= (1.21 AMP X 22) X (0.00051 OHMS/FT) X (5 FT X 2) <br />= 26.62 AMPS X 0.00051 OHMS/FT) X 10 FT <br />= 0.14 VOLTS <br />%VRISE = 0.14 VOLTS - 240 VOLTS = 0.06% <br />THE VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE FUSED AC DISCONNECT IS 0.06% <br />VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP <br />VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br />= (1.21 AMP X 22) X (0.00051 OHMS/FT) X (5 FT X 2) <br />= 26.62 AMPS X 0.00051 OHMS/FT) X 10 FT <br />= 0.14 VOLTS <br />%VRISE = 0.14 VOLTS - 240 VOLTS = 0.06% <br />THE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.06% <br />TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS <br />0.65% + 1.44% + 0.06% + 0.06% = 2.21 % <br />Lumio <br />SMARTENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(22) Q CELLS <br />Q.PEAK DUO BILK ML-G10+ <br />(40OW) <br />(22) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 8.800 kWDC <br />AC SYSTEM SIZE: 6.600 kWAC <br />REVISIONS <br />DESCRIPTION DATE REV <br />PROJECT NAME & ADDRESS <br />2i <br />O <br />w <br />~ U <br />0 Z <br />w <br />0 <br />w U) <br />= w <br />H ry <br />Q <br />Q <br />U) <br />C1 <br />0 <br />N <br />00 <br />O) <br />Q <br />LLI <br />LLI <br />LLI <br />LLI <br />Q <br />W <br />O <br />Lu <br />0 <br />I - <br />CD <br />0 <br />N <br />O <br />0 <br />0 <br />0 <br />00 <br />Ln <br />rn <br />0 <br />0 <br />Z <br />d <br />El <br />I DATE: 11 /3/2022 1 <br />SHEET NAME <br />SPECIFICATIONS <br />& NOTES <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-8 <br />