Laserfiche WebLink
1❑ <br />❑2 <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD SIDES MAY <br />BE ENERGIZED IN THE OPEN POSITION <br />LABEL LOCATION: <br />POINT OF INTERCONNECTION, MAIN SERVICE <br />DISCONNECT, AC DISCONNECT, AC COMBINER, <br />INVERTER <br />PER CODE: NEC 690.13(B) <br />NACAUTION I <br />DUAL POWER SOURCE <br />SECOND SOURCE IS <br />PHOTOVOLTAIC <br />LABEL LOCATION: <br />MAIN SERVICE DISCONNECT/ AC DISCONNECT/ <br />F5] <br />0 <br />MAIN SERVICE PANEL/ REVENUE METER/ AC <br />COMBINER <br />PER CODE: NEC 705.12(C) 8 <br />LABEL LOCATION: <br />AC DISCONNECT <br />PER CODE: NEC 690.56(C)(2) <br />LABEL LOCATION: <br />INTERACTIVE SYSTEM POINT OF INTERCONNECTION <br />PER CODE: NFPA 70, NEC 690.54 <br />LABEL LOCATION: <br />CONDUIT <br />PER CODE: NEC 690.31(D)(2) <br />CAUTION: SOLAR CIRCUIT <br />3 CAUTION : SOLAR ELECTRIC LABEL LOCATION: <br />SYSTEM CONNECTED MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, <br />ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND <br />LABEL LOCATION: ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES <br />PER CODE: IFC 606.11.1.4 <br />POINT OF INTERCONNECTION & INVERTER <br />PER CODE: NEC 690.15 & 690.13(B) <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID <br />SHUTDOWN SWITCH <br />TO THE 'OFF' <br />POSITION TO SHUT SOIAR ELECTRic <br />DOWN PV SYSTEM PV PANELE <br />AND REDUCE <br />SHOCK HAZARD IN <br />THE ARRAY <br />I APPI 10r..ATI(1N- <br />MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE <br />PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE <br />AC DISCONNECT <br />PER CODE: 2020 NEC 690.56(C) <br />LABEL LOCATION: <br />INVERTER & JUNCTION BOXES (ROOF) <br />PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) <br />ADHESIVE FASTENED SIGNS <br />• THE LABEL SHALL BE SUITABLE FOR THE <br />ENVIRONMENT WHERE IT IS INSTALLED. <br />• WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL <br />FIELD APPLIED LABELS, WARNING AND MARKINGS <br />SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) <br />FIELD MARKING]. <br />• ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF <br />PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER <br />RESISTANT [IFC 605.11.1.3] <br />Lumio <br />SMART ENERGY TODAY <br />(SET) <br />1550 DIGITAL DR, LEHI, UT <br />84043, USA <br />SYSTEM INFO <br />(22) Q CELLS <br />Q.PEAK DUO BILK ML-G10+ <br />(400W ) <br />(22) ENPHASE <br />IQ8PLUS-72-2-US (240V) <br />DC SYSTEM SIZE: 8.800 kWDC <br />AC SYSTEM SIZE: 6.600 kWAC <br />REVISIONS <br />DESCRIPTION I DATE IREV <br />PROJECT NAME & ADDRESS <br />Q <br />W <br />M <br />CD <br />N <br />00 <br />>Q O <br />N <br />o <br />W IT <br />o <br />Z W po <br />W > L0 <br />W 'IT <br />W <br />W LLJ <br />.. <br />H <br />H <br />i <br />Q *k <br />o a <br />G <br />W <br />Ln <br />O <br />ti <br />Lf) <br />DATE: 11 /3/2022 <br />SHEET NAME <br />SIGNAGE <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-9 <br />